Post by dasch on eCockpit - unable to start simulation CODESYS Forge talk (Post)
This is a known bug in e!Cockpit. See Release notes of V 1.11: 1 e!Cockpit Release Version 1.11 (2022-07) ATTENTION: If a library that uses asynchronous tasks (e.g. WagoAppConfigTool, WagoAppCloud or function modules such as Dali-Master) is dragged into the project, the simulation cannot be started. It is already sufficient to add the library to the project (an FB does not even have to be instantiated). I guess you are using one of these libraries/modules in your project. We e.G. often use PWM modules, these are also affected.
Last updated: 2023-09-05

Post by macros8 on Alarm Management - latched variable represented as Text list CODESYS Forge talk (Post)
Hi all, in Alarm management you can latch some variable to show value within the alarm msg. It´s very useful sometime. But I´m wondering whether there is any possibility to represent that value as Text list. It´s quite common in other HMI tools and this is very useful in case of using some ErrorID for detail specification of error. Unfortunately I could not find any way how to do it but I believe that exists :) Thanks a lot. M.
Last updated: 2023-09-06

Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing i´m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that i´m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now i´m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10

Post by janderson on Ethercat scan for devices not picking up EL7041 as a softmotion axis CODESYS Forge talk (Post)
it appears that the different revisions have different PDOs. I am currently trying to use the rev25. I have tried to use the rev24 (the device repository entry not from 'scan for devices') and i keep getting 'invalid output mapping' or 'invalid input mapping' in the ethercat log. I cant even get the bus to run from the device description that comes from 'scan for devices'...
Last updated: 2023-09-18

Post by janderson on Ethercat scan for devices not picking up EL7041 as a softmotion axis CODESYS Forge talk (Post)
it appears that the different revisions have different PDOs. I am currently trying to use the rev25. I have tried to use the rev24 (the device repository entry not from 'scan for devices') and i keep getting 'invalid output mapping' or 'invalid input mapping' in the ethercat log. I cant even get the bus to run from the device description that comes from 'scan for devices'...
Last updated: 2023-09-18

Post by manuknecht on Detect "Cancel" Press in FileOpenSave Dialog CODESYS Forge talk (Post)
When using the FileOpenSave dialog and using the Visu_FbFileListProvider FB as an In/Output I could not manage to detect the difference of pressing the "Load" button on the dialog vs. pressing the "Cancel" button. In both cases, the selected file is updated if the dialog is closed when checking using the Visu_FbFileListProvider.GetSelectedFileName() command. How can I prevent reading or writing of a file when the "Cancel" button was pressed?
Last updated: 2023-09-19

Post by timvh on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Post)
I'm not really sure what you are trying to do, but maybe you are referring to using the CmpCharDevice library? When you "open" the connection to a device, you can pass flags. What helped me is to set the non-blocking flag. I'm not sure if this is what you are referring to, but maybe it helps: dFlags: DINT := CmpCharDevice.ACCESS_MODE.O_RDONLY + DINT#4000; // see details for flags: http://linux.die.net/man/2/open, + DINT#4000 is for non-blocking hDevice := CmpCharDevice.CDOpen(szFilename, dFlags, Result);
Last updated: 2023-09-20

Post by nico01 on Integer with comma in visualization CODESYS Forge talk (Post)
Hello everyone, I created a visualization with a lot of REAL, with one or two digits after the decimal point. This causes me problems in terms of rounding and memory... is it possible to display an integer with a comma, like with PROFACE or SIEMENS? It's just an "abuse" of display, the comma is just on the visualization. This limits the memory (16 versus 64 bytes) and rounding is easier to manage... See print screen on proface software THANKS
Last updated: 2023-09-20

Post by aott33 on Webvisu NO load CODESYS Forge talk (Post)
Thanks, I will check the PLC Log when the PLC is connected again. I will update my findings here. Since I don't have access to the Linux Panel PC at the moment, I tested inside my development VM with the same Linux OS. I have no issues or delays connecting to the WebVisu using my Linux VM. Two main differences: 1. My host Computer has a faster processor compared to the panel PC. 2. There are no devices connected in my dev environment. I will continue testing when I have connection to the panel PC.
Last updated: 2023-09-23

Post by docker on Canopen connection. Unknown node id. CODESYS Forge talk (Post)
hi, i am currently trying to adapt an i/o device for a project. the node id is unknown and there is no eds file available. no data is being emitted from the device as a giveaway, the baudrate is known but useless without the node id. is there an sdo request available to determine the id? i cannot get the device to leave pre op status even with a global nmt request. please help. no hair left.
Last updated: 2023-09-25

Post by timvh on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs CODESYS Forge talk (Post)
What maybe helps is the Visu Dialog ST demo project: https://store.codesys.com/en/visu-dialog-st.html This has an application IECOpenDialog where dialogs are opened using the VU.FbOpenDialogExtended function blocks. The fbOpenConfigurationDialog call has a reference (interface) to the "close listener" FB of which it's method is automatically called when the dialog is closed. This way you can create specific function blocks for each dialog when it is closed and do what you want with the data that might have been changed.
Last updated: 2023-09-28

Post by tehthoams on Library Search not working CODESYS Forge talk (Post)
Hello All! Having a strange issue. When adding a library, I'm unable to search. Each time a window pops up 'creating the search index' and then has 0 results. I have the same behavior when using the library repository and pressing the 'Find' button. I wonder if there is a way to reset or fix this issue? It is making it very difficult to search and find proper libraries to add to my project. Much appreciated.
Last updated: 2023-10-17

Post by davidbo on RPI How to login for a copy of the SD image CODESYS Forge talk (Post)
I had one RPI device where I could login. I copied the SD-flash over to another SC-flash. This new SD-flash was inserted in the new device. I can boot the new device but I cannot login why? How can I install an application on this new device? Control 4.4.0.0 cat os-release PRETTY_NAME="Raspbian GNU/Linux 11 (bullseye)" NAME="Raspbian GNU/Linux" VERSION_ID="11" VERSION="11 (bullseye)" VERSION_CODENAME=bullseye ID=raspbian ID_LIKE=debian HOME_URL="http://www.raspbian.org/" SUPPORT_URL="http://www.raspbian.org/RaspbianForums" BUG_REPORT_URL="http://www.raspbian.org/RaspbianBugs"
Last updated: 2023-10-18

Post by hgpiepel on CSV Datei in einem freigegebenen Netzlaufwerk speichern CODESYS Forge talk (Post)
Hallo zusammen, ich erstelle eine CSV-Datei, die im Moment mit file.Write lokal in einem Verzeichnis (/home/pi/Logdaten/logData.csv) gespeichert wird. Jetzt möchte ich die gesammelten Daten aber gerne im Netzwerk speichern. Der Versuch, die Datei unter //Server/Public/logData.csv zu speichern, hat sich so geäußert, dass ein Ordner (Server) im Stammverzeichnis auf dem Pi mit Unterordner erstellt wurde und dort die Datei abgelegt wurde. Gibt es hier eine einfache Möglichkeit, die Datei vom Pi herunter zu bekommen? Leider habe ich im Netz nicht wirklich was hierzu gefunden. Grüße Hermann
Last updated: 2023-10-30

Post by nathant on Can't open online view of FB instance from code editor, only from Device/POU windows CODESYS Forge talk (Post)
Hello, The title pretty much says it all. When trying to open a FB from the CFC/Ladder/SFC editors while online, the FB does not open in an online view of that specific instance. Instead, it opens an offline view with '???' shown for the value of any variable. This makes debugging extremely cumbersome, as I have to find each FB in the POU window and select the specific instance I am trying to view. Anyone know the cause/solution for this? Thanks.
Last updated: 2023-11-08

Post by timvh on SafetyApp - "Invalid ERR Ack input" CODESYS Forge talk (Post)
I had a similar error "Invalid ERR Ack input". What you need to do is link an variable from the "non-safe" PLC to the Group IOs of the POU in the Safety app. * Add a POU to the SafetyApp (probably already done, otherwise you don't get this error) * Right click on this POU - select properties * Go to the Group IOs tab * Link a variable to the Err.Ackn. input I don't know about the Size of zero, I didn't get this error. Were you able to fix this?
Last updated: 2023-11-16

Post by drno on AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030 CODESYS Forge talk (Post)
Hallo zusammen, auf einer Industriesteuerung (Target-Version 3.5.5.0) läuft unter anderem eine Alarmverwaltung mit Alarmspeicherung. Offensichtlich kann kein Schreibzugriff auf das .sqlite File durchgeführt werden, daher ist die Alarmhistorie nicht mehr verfügbar. Versuche mit unterschiedlichen Unterverzeichnissen führten nicht zum Erfolg. Die Datei "application.alarmstorage.sqlite" wird zwar angelegt, aber es erfolgen keine Einträge. Hat jemand eine Idee dazu? Die Steuerung ist ca. 8 Jahre in Betrieb, die Alarmhistorie hat früher mal funktioniert. Danke, LG
Last updated: 2023-11-21

Post by joanm on Tab control element, hide/show tabs programatically? CODESYS Forge talk (Post)
Hi all, Is it possible to hide or show tabs from the PLC code? I have created a few tabs in my visualizations to configure the program behavior, I'd like to be able to hide some of them if the related option in the main tab has been disabled. Is that possible? if so, how should I do it? Thank you all in advance.
Last updated: 2023-11-25

Post by siggi95 on Übersetzungsfehler J1939 changeAdress (4.1.0.0) CODESYS Forge talk (Post)
Hallo zusammen, für den Aufruf VAR deviceDiag: J1939.IJ1939LocalECU; END_VAR deviceDiag.ChangeAddress(5); gibt es mit der Version 4.1.0.0 der Lib IoDrvJ1939 Übersetzungsfehler - C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'deviceDiag.ChangeAddress' erwartet - C0004: 'ChangeAddress' ist keine Komponente von 'IJ1939LocalECU__Union' Mit der bisher verwendeten Lib-version 3.5.17.0 nicht und auch das Setzen der device adress hat funktioniert. Lt. Release notes ("J1939: ChangeAddress method does not work properly.") wurde hier verbessert. Leider habe ich keine Beschbreibung dazu gefunden. Wie muss der Aufruf angepasst werden? Vieeln Dank und beste Grüße Siggi
Last updated: 2023-11-29

Post by alink on Visu - changing auto-logout time CODESYS Forge talk (Post)
Hello is there a chance to set with a visu input the auto-logout time? At the moment, it is a fix value set in visu-manager. But for individual configurating of passwort policies I create a visu-dialog to set policies and there for an option to set auto-logout-time. But till now, I haven't found a solution. Maybe someone has an idea? Thanks
Last updated: 2023-11-30

Post by macros8 on Translation - How to get text as reference in Frames translated? CODESYS Forge talk (Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01

Post by macros8 on Alarm Management - Import and Export of AlarmGroup CODESYS Forge talk (Post)
Hi, I struggle with exporting my Alarm Messages and following importing back to my project. Because filling in one by one is very time consuming I want to use export function and edit .csv file in Excel. As soon as I modify the file the import back to project does not work at all and function returns errors. Would you pls give me a hint how to properly use this functionality? Thanks a lot for help. Regards, M.
Last updated: 2023-12-02

Post by simotion on Inheritance of axis CODESYS Forge talk (Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07

Post by voffi on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
There are some ways. One is to use SHR and SHL and it depends on your byte order in the data array. For Motorola byte order: PROGRAM PLC_PRG VAR u : UINT; byte_array_in : ARRAY [1..8] OF BYTE := [16#11, 16#12, 16#13, 16#14, 16#15, 16#16, 16#17]; byte_array_out : ARRAY [1..8] OF BYTE; END_VAR u := SHL(TO_UINT(byte_array_in[2]), 8) + TO_UINT(byte_array_in[1]); byte_array_out[1] := TO_BYTE(u); byte_array_out[2] := TO_BYTE(SHR(u, 8)); If it's Intel byte order just change 1 and 2 in the array indexes.
Last updated: 2023-12-07

Post by nz-dave on Bool turning on in case stament in wrong state? CODESYS Forge talk (Post)
I have a case statement running a process. during one of the steps it has started calling a bool var that is 2 steps further on in the case? i have even tried //commenting it out but it still turns on at the same point in the case. i have also run a trace but cant see anything that would trigger it. Any Ideas? Cheers
Last updated: 2023-12-15