Post by arwie on Working on exporting/importing projects to PlainText.
CODESYS Forge
talk
(Post)
To better track project changes in git I created a script that exports the project structure as text files. Textual POUs are stored as text, everything else as XML (with timestamps removed). The file structure is stored under path/to/your.project.txt Git merge will not work, but at least tracking changes is much easier. Script: https://github.com/arwie/controlOS_demo/blob/main/codesys/txtfy.py Example output: https://github.com/arwie/controlOS_demo/tree/main/codesys/controlOS_demo.project.txt
Last updated: 2025-07-24
Post by eschwellinger on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore
CODESYS Forge
talk
(Post)
1) https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html -> SL: Restrictions The combination of Raspberry Pi and a CODESYS Runtime is for private use, test and teaching purposes. Commercial use is not permitted. 2) you could switch between them by /etc/codesyscontrol/CODESYSControl_User.cfg [CmpRasPi] Architecture=armv7l for MC: armv7l for SC: armv6l for 64Bit: aarch64 or in the Deploytool:
Last updated: 2025-08-06
Post by phryniszak on RPI CANFD
CODESYS Forge
talk
(Post)
Hi, I have rpi with CANFD MCP2518FD. Classic can communication is working OK but when I try open in CANFD hDriver := CL2.FdDriverOpenH(usiNetId := 0, uiNominalBaudrate := 500, uiDataBaudrate := 0, xSupport29Bits := FALSE, ctMessages := 100, peError := ADR(eError) error is returned with value 10226 which is not documented (https://content.helpme-codesys.com/en/libs/CAA%20Can%20Low%20Level%20Extern/Current/CAN-Low-Level/Enums/ERROR.html#error) CAA CanL2 is 3.5.21 version. Question is: 1. Is anyone get CANFD working? 2. What is meaning of this value (10226)? Regards, Pawel
Last updated: 2025-08-09
Post by phryniszak on RPI CANFD
CODESYS Forge
talk
(Post)
Hi, I have rpi with CANFD MCP2518FD. Classic can communication is working OK but when I try open in CANFD hDriver := CL2.FdDriverOpenH(usiNetId := 0, uiNominalBaudrate := 500, uiDataBaudrate := 0, xSupport29Bits := FALSE, ctMessages := 100, peError := ADR(eError) error is returned with value 10226 which is not documented (https://content.helpme-codesys.com/en/libs/CAA%20Can%20Low%20Level%20Extern/Current/CAN-Low-Level/Enums/ERROR.html#error) CAA CanL2 is 3.5.21 version. Question is: 1. Is anyone get CANFD working? 2. What is meaning of this value (10226)? Regards, Pawel
Last updated: 2025-08-09
Post by yannickasselin on Dynamically enabling/disabling Modbus slave devices in runtime (performance issue with timeouts)
CODESYS Forge
talk
(Post)
I would definitely try using the "Reconfigure" function block from "CAA Device Diagnosis@ library. https://content.helpme-codesys.com/en/libs/CAA%20Device%20Diagnosis/3.5.17.0/CAA-Device-Diagnosis/Function-Blocks/Reconfigure/Reconfigure.html#:~:text=This%20function%20block%20reads%20and,take%20effect. Although I have not tried it with Modbus, I had great success with EtherNet/IP, Profinet and EtherCAT. You can also have a look at the other functions in this library. There are useful functions to help iterate through all the nodes under a master node.
Last updated: 2025-08-12
Post by pernockham on Persistence Manager: Config File not found?
CODESYS Forge
talk
(Post)
I still cannot enable persistent manager for my project (and successfully login to a device). Project compiles with no errors but during download/login it fails with the fairly limited message "one or more errors occurred". The only clue I get from the system that this messages is displayed during "Generating code..: relocation pou". Any tips pointing me in a direction how to solve this very much appreciated!
Last updated: 2025-08-22
Post by sigurdrb on Network log messages
CODESYS Forge
talk
(Post)
Hi, I'm having some trouble with an OPC client connecting to the PLC. It could be that the problem is on the client side of things. The PLC have UPS power, but the switch and OPC client does not. It could explain some of the log messages. Could any of you help debugging by the log messages in the attachment? And if possible point me to the right library that explains the different messages? Thanks for all the help.
Last updated: 2025-09-11
Post by monw on Unable to Re-Import Native XML Exported Using CODESYS Script API
CODESYS Forge
talk
(Post)
When exporting a Logical Device or Logical Exchange GVL using the native XML export functionality of the CODESYS Script API, I encounter the following error upon re-import: "Error in IEnumeratorOfTWrapper. Current. Could not cast: System.String in System.Char" I am using CODESYS V3.5 SP21 Patch 2. Is there a known solution or workaround for this issue? Notably, importing the same XML file through the CODESYS Engineering IDE's menu import works without error.
Last updated: 2025-09-12
Post by nha451 on EIP Scanner not receiving data from adapter
CODESYS Forge
talk
(Post)
Hello, I have an EtherNet IP adapter (GoPxL) running with a virtual PLC. I have successfully connected the adapter with green icons next to it. On WireShark I can see the data coming from GoPxL but on CODESYS it shows up as all 0. My firewall is turned off and I have enabled the device to always update variables. I tested my set up with Profinet and I can receive the data. Please let me know if you have any suggestions!
Last updated: 2025-09-12
Post by reinier-geers on CAnopen stack
CODESYS Forge
talk
(Post)
Ive got a project with 6 devices . Version 3.5.9.2 Now i change one to a other device 3.5.20.40 So i update the project to V3.5.20.4 Now i have a lot off faults in the canopendevices . Somehowe the first has no problem and seems that the canopenstackts stays in V3.5.9.2 the others in V4.2.0.0 But i cant put it back to 3.5.9.2 WHY ? And how can now witch one i can update and witch one not ?
Last updated: 2025-09-22
Post by reinier-geers on CAnopen stack
CODESYS Forge
talk
(Post)
Ive got a project with 6 devices . Version 3.5.9.2 Now i change one to a other device 3.5.20.40 So i update the project to V3.5.20.4 Now i have a lot off faults in the canopendevices . Somehowe the first has no problem and seems that the canopenstackts stays in V3.5.9.2 the others in V4.2.0.0 But i cant put it back to 3.5.9.2 WHY ? And how can now witch one i can update and witch one not ?
Last updated: 2025-09-22
Post by esther on subdevicesCollapsed attribute in deviceDescriptor
CODESYS Forge
talk
(Post)
I was trying to use subdevicesCollapsed attribute in device descriptor in order to not expand the subdevices when a new device with subdevices is inserted in the device tree. I use this as follows:<fixed subdevicescollapsed="true">. But it seems it doesn`t work. I am ussing Codesys v3.5 SP16 Patch4. Is anything wrong with this? Or am I mistaken with the use of this attirbute?</fixed>
Last updated: 2025-10-01
Post by gseidel on MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl [ERROR]
CODESYS Forge
talk
(Post)
Hi imdatatas, sorry to hear this issue caused so much overhead for you. Frankly, I'd expect a project created with an older version to compile without errors after opening > it with the latest Codesys version and updating all libraries. Yes, that is a reasonable expectation. I tried a few times but could not reproduce the problem. In case you run into the problem again, we can investigate the issue if you send a project archive. Best regards, Georg
Last updated: 2025-10-02
Post by timvh on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
CODESYS Forge
talk
(Post)
If you are a vendor of controllers and want to have your own CODESYS Runtime on your device, then you need to contact the CODESYS Sales team and ask for the runtime Toolkit. For resellers of CODESYS devices, this can be interesting. If it is only for a few devices, then why not just take the standard runtime?
Last updated: 2025-10-07
Post by mdetrana on VPLC Section 'Gray-ed Out'
CODESYS Forge
talk
(Post)
When evaluating Codesys functionality, I found that the VPLC tab under Deploy Control SL > Operation > VPLCs is 'gray-ed out', see attached image. I'm trying to evaluate how my infrastructure will interact with Codesys on a Raspberry Pi 4, so I'm trying to demo running it. I was going through the Codesys tutorial here, and it never shows the tab as grey, so I do not know how to proceed. Let me know if I can get any additional information that can help.
Last updated: 2025-10-09
Post by zatalian on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05
CODESYS Forge
talk
(Post)
There seem to be problems with the latest version of raspberry pi os 64bit (I used the lite version). The codesys control runtime crashes after a few seconds. The same runtime works on the raspberry pi image from 2023-10-10 When starting the runtime from the commandline, i get the following error: ooops... this runtime was build for RASPBERRYPI. Hardware version or firmware version not supported! (and yes, I'm running this on a raspberry pi :-)
Last updated: 2023-12-11
Post by eschwellinger on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
we need some logfiles from the edge gateway /etc/Gateway.cfg [CmpLog] CmpEdgeGateway.Filter=0xFFFFFFFF Logger.0.Name=/tmp/codesysedge.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=100000 Logger.0.MaxFileSize=5000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC and does the scan via Automation Server show the plc?
Last updated: 2024-01-09
Post by felipemsgarcia on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
Hello, I couldn't figure what/where the issue was, so I deleted everything from automation server and reinstalled the edge gateway and did the process again. It worked for about a month and then it stopped working again. It presents the same symptom, edge gateway is online but I can't connect to the PLC. Any idea of what could be the issue? Thank you!
Last updated: 2024-01-09
Post by rodberna on Library for arrays
CODESYS Forge
talk
(Post)
Hi, I'm creating a program where I need to handle arrays, like: - Declare lenght variable arrays - [array(1..var) of "sometype"]. This is not possible in pure codesys, right? - Know array lenght, min, max, avg values in runtime - append/delete itens in an array - and so on Is there a library know for this in codesys. Is it possible to build our own libraries using some high level language like python or java script?
Last updated: 2024-01-10
Post by timvh on Minimum system requirements for codesys control standard S
CODESYS Forge
talk
(Post)
It depends on your application which CPU speed and RAM size you need. If you think the Control Standard S license is sufficient then my guess is that your selected PC has no problem running your application. There are no more "hardware" based single licenses available anymore, only application based licenses. So this "Raspberry Pi" restriction for home automation is not applicable anymore. For more information see: https://store.codesys.com/en/howto_applicationbasedlicenses
Last updated: 2024-01-14
Post by sturmghost on Find visualization elements that require a lot of computing time
CODESYS Forge
talk
(Post)
I found out that the Codesys simulation mode is not good to measure performance. As soon as I upload the code onto the hardware PLC I can see that my visu-task needs around 60 ms to complete. I'm wondering if there is a possibility to find out which visualization/visualization element takes a lot of computing time? Then I would look for ways to decrease the long computing time.
Last updated: 2024-01-22
Post by haydermsalih on OSCAT Network LIBRARY: FTP_CLIENT
CODESYS Forge
talk
(Post)
Hello I am using FTP_CLIENT to donwnload/Upload a text or CSV file from FTP server. UpLoading from PLC to FTP server is working without any problem but when I try to download from FTP server I get an error. The FTP_CLIENT Block allows me to add URL but I do not where I can specify the direcory to save the downloaded file... is there anyone has an experience with downloading from FTP server using FTP_CLIENT block. Thanks in advance Hayder
Last updated: 2024-01-24
Post by jaspergain on Access to the path *** is denied
CODESYS Forge
talk
(Post)
Hello, Recently I upgraded to 3.5.19.50 and have been having errors/issues when doing a download/online change. The message as seen in the attachment pops up. The file in the path is different every time. However when I login again afterwards all works fine. This issue does not happen on older versions. Any clue what the issue could be? I did an reinstall/repair but the issue reappeared again... Thanks in advance!
Last updated: 2024-01-25
Post by wiresplus on INT_TO_WORD function not working
CODESYS Forge
talk
(Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26
Post by josephbourgeois on Tracking out product
CODESYS Forge
talk
(Post)
Hi everyone! I synchronize the operation of the tripod and the conveyor. I have a problem with the product tracking algorithm on the conveyor (PCS_1). Sometimes I need to stop tracking a product on command without completing the operation. I do this using MC_GroupStop. But when I need to start moving in WCS again (using fb movelinearabsolute), I get a tripod kinematics error - SMC_CP_INVALID_ORIENTATION (Invalid orientation (non-orthonormal matrix or non-unit quaternion, internal error)). MC_ResetGroup does not help. What could be the problem? Has anyone encountered this?