Post by jkessler on IoDrvModbusTCP_Diag not defined when using MODBUS
CODESYS Forge
talk
(Post)
Hi, Same for me ! Works in Codesys 3.5.19 but not in 3.5.20. I'm currenly using with a WAGO PLC200 [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0046: Identificateur 'IoDrvModbusTCP_Diag' non défini [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0080: Le bloc fonctionnel 'IoDrvModbusTCP' doit être instancié pour permettre l’accès [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0004: 'IoDrvModbusTCP_Diag' n’est pas un composant de 'IoDrvModbusTCP' [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0046: Identificateur 'ModbusTCPSlave_Diag' non défini [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0080: Le bloc fonctionnel 'IoDrvModbusTCP' doit être instancié pour permettre l’accès [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0004: 'ModbusTCPSlave_Diag' n’est pas un composant de 'IoDrvModbusTCP' [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0046: Identificateur 'ModbusTCPSlaveUnit_Diag' non défini [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0080: Le bloc fonctionnel 'IoDrvModbusTCP' doit être instancié pour permettre l’accès [ERREUR] EmPlcProgram: Application [Device: Logique API]: C0004: 'ModbusTCPSlaveUnit_Diag' n’est pas un composant de 'IoDrvModbusTCP' Thanks in advance
Last updated: 2024-05-29
Post by greenwood on CODESYS Control Raspberry Pi mit Servotreiber T6 von StepperOnline
CODESYS Forge
talk
(Post)
Hallo, Ich scheine den Grund gefunden zu haben, das Kabel mit dem RJ45 Stecker ist für RS232 verdrahtet (am anderen Ende des Kabels ist ein 9-poliger SUB-D Stecker, nicht wie von mir im Eingangspost behauptet ein USB Stecker). In der Anleitung des Treibers ist immer nur von RS 485 die Rede. Alerdings habe ich es gestern abend noch geschafft eine funktionierende Version der setup-software herunterzuladen, und die verbindet sich offenbar über RS232. Daraufhin habe ich mir in der Anleitung des Treibers das Pinout der RJ45 Buchse nochmal angesehen, und die hat Kontakte für RS232 und für RS485. (Die liegen jeweils ganz am Rand, so ist mir das vorher nicht aufgefallen). Ich muss also als Nächstes ein richtig verdrahtetes Kabel auftreiben, und dann sehen ob das mit dem Adapter den ich habe funktioniert. An einen Abschlusswiderstand habe ich auch schon gedacht, nur weiss ich nicht wo ich den an einem RJ45 Stecker / Buchse - Paar anbringen soll... Ich bitte um Entschuldigung für die Verwirrung, ich mache das alles zum ersten Mal und es ist ganz schön viel auf einmal für mich. Nochmal vielen Dank für die Unterstützung!
Last updated: 2024-06-01
Post by nikgind on Codesys Communication Manger - Required information model version exists in the model repository but is not found
CODESYS Forge
talk
(Post)
Hi I am trying to import a custom information model that I created using UA Modeler. I have only added two new methods and two new object types. It is possible to add the information model to the Communication Manager and the two new object types are shown in the Information Model tab. After compiling i get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://yourorganisation.org/Bsp_3.1/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. The error message does not make sense to me. Should it not be “Probably the information model from 15/12/2023 is missing in the information model repository”? Anyway I have installed the information model from 15/12/2023 but not from 15/09/2021. Which makes the error message even stranger.
Last updated: 2024-06-09
Post by brubingh on Download Missing Libraries not working
CODESYS Forge
talk
(Post)
We are working on a project and the customer required 3.5.16 BF4. After working on the project for a few weeks I opened it the next morning and it could not access libraries. IecVarAccess could not be accessed. I checked if windows updated - it did not. So no explanation for why it lost access other than that I shut down the computer for the night. Note that I am using a demo license. I still haven't figured out any reason to purchase a license. So I spent the next hour reinstalling CodeSys. Note that I did NOT uninstall first. After install I waited another 5 minutes for it to open the first time. I clicked File->Open to open the project. Previously I had selected File->Recent Projects - not sure if that makes and difference. But after this process it did open the project and compile it just fine. This is miserable. If this had happened when I went on site to a customer I would have lost hours of work doing the reinstall. Is there a different and quicker fix?
Last updated: 2024-06-13
Post by xgongx on What is the insights of IoDrvEtherCAT.DCInSyncWindow?
CODESYS Forge
talk
(Post)
It is well known that you need to increase the value of IoDrvEtherCAT.DCInSyncWindow to solve the "Fieldbus lost synchronicity" issue. In the official document, IoDrvEtherCAT.DCInSyncWindow is explained as the toleration of a certain jitter. But the official document doesn't explain what kind of the jitter is. Is it the jitter of DC sync deviation, master timer or something else? It is very important to know the insights of IoDrvEtherCAT.DCInSyncWindow. For example, if it is the toleration of DC sync deviation, and the official recommending value is 200us for CODESYS SoftMotion. It means maximum of DC sync deviation is 200us. It is unacceptable for some high precision motion control tasks, for example high speed gear task, etc. Increasing the value of IoDrvEtherCAT.DCInSyncWindow will increase the deviation of motor rotation sync if it is the toleration of DC sync deviation. So, would anyone tell me what the insights of IoDrvEtherCAT.DCInSyncWindow is? Thanks.
Last updated: 2024-07-09
Post by timvh on How to implement an interface (IElement)?
CODESYS Forge
talk
(Post)
See: https://forge.codesys.com/prj/codesys-example/element-collect/home/Home/ This contains an application "OnlineChangeSafeLinkedListExample". What you should do is create a new interface which has your "Priority" property. Then your FB should extend the base element function block and implement your own interface: E.g. FUNCTION_BLOCK MyElement EXTENDS COL.LinkedListElementBase IMPLEMENTS I_MyInterface Then the __QUERYINTERFACE does the magic to check if your "element" also implements your interface. Something like this: // Compares this element with itfElement. // Returns 0 if the elements are equal, < 0 if the element is less than itfElement, // > 0 if the element is greater than itfElement. // This method will be called from sorted collections (e.g. |COL.SortedList|) to sort the elements. // IMPORTANT: The underlying value to be compared with MUST NOT be changed during the lifecycle of the object. METHOD ElementCompareTo : INT VAR_INPUT (* The element to compare*) itfElement : COL.IElement; END_VAR VAR itfIntElement : I_MyInterface; xResult : BOOL; END_VAR // We use integer iInt1 for sorting. xResult := __QUERYINTERFACE(itfElement, itfIntElement); IF xResult THEN IF iInt1 < itfIntElement.Priority THEN ElementCompareTo := -1; ELSIF iInt1 > itfIntElement.Priority THEN ElementCompareTo := 1; ELSE ElementCompareTo := 0; END_IF ELSE ElementCompareTo := -1; END_IF
Last updated: 2024-07-22
Post by denkihitsuji on Content update through Data URI on Web Brower on Visualization Toolbox
CODESYS Forge
talk
(Post)
Objective: I want to dynamically update the content with strings and JPEG images received from a TCP/IP socket. For this purpose, I am exploring the possibility of utilizing the Web Browser feature of the Visualization toolbox. Example: In a standard web browser, entering data:text/plain;charset=utf-8;base64,SGVsbG8gc3RyYW5nZXI= in the URL window will display "Hello stranger" on the webpage. Issue: When attempting to use this method in the Web Browser of the Visualization toolbox, the content does not display as expected. Instead, it shows the error:'Navigation to the webpage was canceled.'. Request: I seek guidance on how to resolve this issue so that the Web Browser in the Visualization toolbox correctly interprets and displays the data URI content. Alternative Solution Welcomed: Or, if it is possible to directly use Codesys Structured Text (ST) variables within an HTML page, this approach would also meet my requirements. Thank you for your attention.
Last updated: 2024-07-30
Post by sturmghost on Mimic behavior of the visualization button element with a custom button
CODESYS Forge
talk
(Post)
Im wondering how Codesys is doing the mouse event capturing with their visualization button element? If you add such a button without configuring any input configuration event (like OnMouseDown) or button state variable and then click on the button, the button changes to the visual pressed state and back if you release the button (so they must react to an OnMouseDown event). But how? If I try to mimic this behavior with my custom button visualization element (like a basic rectangle) I need to use an input configuration event to change the color of the button (to make it look like the button was pressed on OnMouseDown event). When I try to add this button via a Frame-Element to my main visualization page I'm unable to use an input configuration event on the Frame-Element because the input configuration event on the button element won't be evaluated anymore (it seems like you can't stack input fields, e.g. invisible input elements, onto each other). Hence the button is not shown pressed anymore. How they do it?
Last updated: 2024-08-04
Post by c3po on Von SNMP auf IIoT wechseln
CODESYS Forge
talk
(Post)
Hallo, 1. ich bin komplett NEU was Codesys angeht 2. ich muss direkt ein Retrofit machen von V2 auf V3 3. Neue Steuerung: WAGO 750-8211 PFC200. 4. das Projekt in V2 hat über SNMP daten im Netzwerk zur Verfügung gestellt, oder diese gelesen 5. das Projekt in V3 kann SNMP nur noch eingeschränkt nutzen, deswegen wurde mir vom WAGO Support nahegelegt die IIoT Lib zu verwenden. Frage: Wie mach ich das? Konkret: Ich habe die WagoAppSNMP Bibliothek installiert, damit kann ich schon mal Set und Get nutzen (hoffentlich, hab es ja noch nicht getestet, sondern nur programmiert). Ist das ein schlauer Weg, das über diese Lib zu machen? Denn: was macht der SNMP_SET_PLCDATA_WRITEAREA ? Den kann ich über die Wago Lib nicht nutzen und weiß auch nicht, was dieser Baustein konkret tut (Bild im Anhang). Es scheint mir, hier werden Daten auf ein Word im Netzwerk geschrieben? Aber geht das nicht auch einfacher? Es ist ja keine Adresse hinterlegt, wo das hin gehen soll oder? Also, ich verstehe den Baustein nicht so ganz und konnte bisher auch keine Erklärung dazu finden. Vielen Dank schon mal für eure Unterstützung, K.
Last updated: 2024-08-19
Post by bruceae on Ethernet/IP Scan
CODESYS Forge
talk
(Post)
Hello, I have a robot configured as a Generic Ethernet Module under Ethernet/IP Scanner. I can not see the change of state of the outputs coming from the robot on the codesys side in real-time. (The robot has it's own internal program that would changes the values of remote outputs 0-3 off and on). Also when I send data down to the inputs of the robot it doesn't transfer over as expected. As an example I'll send to the robot's input bit 0 a value of 1. It doesn't see that value change. However, when I write that input bit 0 back to a value of 0, the robot changes state and shows a value of 1. And if I change the state of a different bit, the other bits update properly, except for the bit that I changed. Any advice would be greatly appreciated, and if anything else is needed let me know.
Last updated: 2024-09-10
Post by bjarne-pagaard on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
Hi, I would like to divide a project into multiple applications - as a minimum: one handling visualization and Alarm Manager, one handling I/O and plant control logic. But how to exchange variables between the applications? What have you done to get such a solution? In versions 3.5.19 and earlier, you can have Child applications, where the children can access a GVL in the Parent application. Children apps is no longer possible in 3.5.20 - but you can have 'sibling' apps - Several apps directly under PLC Logic, that is. But how do they best communicate? The Communication Manager / Data Sources Manager is sort of possible via OPC UA, but it seems like overkill and with some limitations - for example no ARRAY OF STRUCT possible this way. If you have separate devices in your project, you can exchange data via 'CODESYS ApplicationV3', but not other applications in the same device (see attachment Datasources.png). You can do it via 'Select the project type'->'Other Project' and select the same project file, but this leads to crashing the Development system when working with the variables afterwards. It would be great to hear your thoughts / experiences on this topic - Bjarne
Last updated: 2024-09-27
Post by z870623 on About CPU Loading
CODESYS Forge
talk
(Post)
I am running a runtime environment on an ARM A35 dual-core processor (1.5GHz) and have encountered some issues. The CPU load (both CPU0 and CPU1) occasionally spikes above 50% before returning to normal, and this happens around 2-3 times per minute. At the same time, I’ve noticed that the Max Cycle Time in the Codesys monitoring screen shows much worse performance compared to the A53 (1.2GHz), with nearly double the cycle time. The optimizations I have made so far are as follows: Set the CPU to performance mode. Isolated CPUs: CPU0 is dedicated to running Linux services and the runtime itself, while CPU1 runs the EtherCAT task and the MainTask. Despite CPU1 only running these two tasks, the utilization still increases above 50%, which I find unreasonable. Additionally, I performed tests using cyclictest both without and with the runtime running. The performance is shown in the following image: From the results, I believe the CPU performance should be fine, but I am unsure why the monitoring results are not as expected. The testing outcomes should ideally be as close as possible to the cyclictest results. Does anyone have related solutions to this issue?
Last updated: 2024-10-14
Post by mainak on Opaque NodeId in the OPC UA server
CODESYS Forge
talk
(Post)
Hello all, I am using the OPC UA server with my custom information model. I have used the communication manager to add my information model under my application and created instances from OPC UA types. I see that the created instances in the OPC UA server has some opaque nodeid (attached screenshot) and I want to change that. Therefore I have the following questions: 1. Is there a way to configure the NodeIds of instances in the OPC UA server? I tried to edit it using the UaExpert client but got error "BadNotWriteable". is it possible to configure it somewhere so that the nodeids can be changed using an external client? 2. Is there a way to define the rule for creating instance nodeids within the codesys IDE? 3. Is it possible to create the instances before e.g. using a modelling tool like UaModeler and import them as part of the information model and use them later? Using the communication manager, I can only create instances from types. I couldn't find a way to map my existing instances to plc tags from my application. It would be nice if someone could help me with these issues. Thanks in advance. :)
Last updated: 2024-10-19
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Hi, Communication with the ADS1115 is actually simple. 1. write config 2. write address pointer 3. read conversation register The ADS1115 works like a multiplexer. This means that you do this individually for each channel that you want to read. e.g: Channel 1: write config > write address pointer > read conversation register Channel 2: write config > write address pointer > read conversation register Channel 3: write config > write address pointer > read conversation register Channel 4: write config > write address pointer > read conversation register then you start again from the beginning You can also omit individual channels or read only one. It doesn't matter. I have written the driver so that I can also use it on the TCA9548. The driver is from Stefan Dreyer. In your case, the driver works and communication with the ADS1115 is running. As you can see, the cfgWrong:=FALSE If you could not write or read data, cfgWrong:=TRUE; This means that either something is wrong with your ADS1115 or you have connected something incorrectly. Question: what voltage do you want to measure?
Last updated: 2024-11-08
Post by hyys12 on Help understanding analog in-/outputs
CODESYS Forge
talk
(Post)
Hello. I am currently working on a WAGO PLC, where I am trying to wrap my head around how the analog inputs and outputs work in codesys. I have looked far and wide on the internet, for a general introduction to the whole concept, but I have not had any luck with finding anything that helped me understand it better. The whole goal is for me to be able to read an analog input from a temperature sensor, as well as using an analog output, to control a frequency inverter. I know these have nothing to do with each other, but that is all I have on hand right now. I am trying to program this using Ladder Diagram. The only thing is, that every video/guide I have seen/read using LD, just adds a whole lot of function blocks, to do all kinds of stuff they don't explain. My general question is, how would one go ahead and read the analog input, as well as transmit an analog output? Is there some kind of specific function block I would have to use for this, or some great video I can watch, to understand the inner workings. Is it somehow possible to see the values the PLC recieved/sends? Regards.
Last updated: 2024-12-11
Post by edvard-munch on How I can get "Done flag" for "Modbus Slave Channel"?
CODESYS Forge
talk
(Post)
This is from 10 years ago, I know. But I have been using (SLAVE_DEVICE.iChannelIndex = CHANNEL_NUMBER) AND (SLAVE_DEVICE.xDone) I suppose that it shows xDone for the channel that shows up in the iChannelIndex at the same cycle? It seems to be working properly for two devices that I have been using it before But now I have another device and using two write channels, for one register each. One channel works properly and returns DONE flag When another channel is triggered, I see that it shows up in iChannelIndex, but flag DONE not received, but no Error for the channel. Also, when i check the register in the device it's evident that data has been transferred. Is this could happen sometimes with CODESYS, so DONE flag not received? Or this is a problem with a given device? With this certain register
Last updated: 2024-12-19
Post by imdatatas on Read "Homed" status from EtherCAT drive
CODESYS Forge
talk
(Post)
Hello, I have experienced such situations with some servo drive devices in the past. The home completion information is reported to the upper controller by the slave drive with the states of the relevant bits in the StatusWord (for example; 6041h Bit10, Bit12 in Home mode). If the states of these bits are correct in terms of number and state but the motor does not actually perform the action; You can contact the slave drive manufacturer. There may be a problem with the device firmware. Another area you can play around with is looking at the settings in the "Advanced configuration" for Softmotion axis on the page the link to below, and trying it out and using the one that works for you. https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_cmd_add_softmotion_cia402_axis.html A method I recommended worked for a user as in below message. https://forge.codesys.com/forge/talk/Engineering/thread/40bc82454d/ I hope your problem will be solved as soon as possible and by sharing the result here, you will help others to know and overcome it. Good luck. Best regards, Imdat
Last updated: 2 days ago
Post by mubeta on Strange problem with the ‘MC_SetPosition’ function
CODESYS Forge
talk
(Post)
CoDeSys 3.5.19.7 Target Berghof MX6 In a simple SoftMotion programme with two stepperless modular axes from CMZ, one is simply controlled in speed, but a spot must perform a positioning. I use the function MC_SetPosition() both to reference the axis at power-up and also to correct the actual position to a fixed machine reference detected with proximity. The function has only one instance and I actually use a booelan variable to control the ‘Execute’ input. Well, I cannot correctly change the axis position on the fly if it is running at high speed. The servomotor works in a speed range between 0°/s and 720°/s, (gearbox output with a 1:6 ratio). As long as the servomotor is operating at speeds below about 400 °/s, the function is able to correct the position correctly even when forcing values far apart, but at high speeds, from 400 °/s upwards, the correction no longer takes place. For example, trying to correct the position of 280° into 300° with absolute mode, the axis that is moving at speed actually shifts the position by a few degrees, not the expected 20. I don't understand why with the servo drive running slowly the position shift occurs correctly, while increasing in speed it no longer works.
Last updated: 12 hours ago
Post by svenkaro on Codesyscontrol.service stoppt nach 30s
CODESYS Forge
talk
(Post)
Hallo nano, anbei das Logfile ;********* ;<loggername>codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc high resolution</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>100000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</filter></filter></logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;********* 2024-06-20T06:07:12.085Z, 0x0000013d, 16, 0, 0, OpenCpusetCpusEffective: using core(s) "0-3" from /sys/fs/cgroup/cpuset.cpus.effective 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet.so: 0x92ae530 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet2.so: 0x92af008 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpPLCHandler.so: 0x92afb08 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClient.so: 0x92affe8 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpXMLParser.so: 0x92b04c0 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClientCommDrvTcp.so: 0x92b09a0 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <logoptions> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <benable>1</benable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <type>normal</type> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <timestamp>rtc high resolution</timestamp> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <filter>0x0000000f</filter> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxentries>100000</maxentries> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfiles>1</maxfiles> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfilesize>1000000</maxfilesize> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, </logoptions> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgrUnixBackend</cmp>, <id>0x000000a4</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxInterrupt</cmp>, <id>0x000000a2</id> <ver>3.5.17.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxRTDiag</cmp>, <id>0x000000a7</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinux</cmp>, <id>0x00000128</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinuxBackend</cmp>, <id>0x000000a5</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRasPi</cmp>, <id>0x00000089</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRunStopSwitch</cmp>, <id>0x000000a6</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketUnix</cmp>, <id>0x000000a3</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet</cmp>, <id>0x00000400</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet2</cmp>, <id>0x00000401</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpPLCHandler</cmp>, <id>0x0000002a</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClient</cmp>, <id>0x00000021</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClientCommDrvTcp</cmp>, <id>0x00000022</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, MultiCore support: [activated], all cores are used 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, Number of available cores: 4 2024-06-20T06:07:12.134Z, 0x00000401, 2, 0, 0, !!!! Warning: component CmpBACnet loaded already 2024-06-20T06:07:12.184Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>10.94.25.39</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2024-06-20T06:07:12.184Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 2</interface> at router <instance>0</instance> registered 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 2, Running as network server 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 1, Running as network client 2024-06-20T06:07:12.186Z, 0x0000000a, 1, 0, 0, <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, CmpBACnet 1024 BACstack information 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, version = 15.0.1.1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_USED_ALIGNMENT = 4 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, CmpBACnet2 1025 BACstack information 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, version = 25.1.5.1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_MCU_USED_ALIGNMENT = 4 2024-06-20T06:07:12.261Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2024-06-20T06:07:12.262Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2024-06-20T06:07:12.266Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>10.94.25.39</ipaddress> 2024-06-20T06:07:12.266Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>1</instance> registered 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ********** 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Hostname: raspberrypi, Port: 4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, URL: opc.tcp://raspberrypi:4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Multithreading activated. 3 workers used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ************ 2024-06-20T06:07:12.286Z, 0x00000124, 1, 0, 0, Provider 'CODESYS_DefaultProvider' (version 0x305131e) registered at the OPC UA server. 2024-06-20T06:07:12.287Z, 0x000000a6, 1, 0, 0, Not able to read file of Run/Stop switch. Functionality of component disabled 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, CODESYS Control for Raspberry Pi MC SL 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 6, <version>3.5.19.61</version> <builddate>Feb 22 2024</builddate> 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 5, Copyright CODESYS Development GmbH 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.308Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'AlarmManager' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to (0027) 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to (2ddc:0a5e:1927) 2024-06-20T06:07:12.332Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2024-06-20T06:07:12.333Z, 0x00000001, 2, 0, 0, !!!! Warning: no runtime license - running in demo mode(~2 hours) Wäre der Zeitraum nicht nur 30s könnte ich das beenden auf Grund der letzten Zeile nachvollziehen. Hoffe Du hast eine Idee, vielen Dank.
Last updated: 2024-06-20
Post by dandyk on Dynamic Images
CODESYS Forge
talk
(Post)
Hello, I have very similar problem, but it seems that your solution does not work for me. I am using TwinCAT XAE Shell v3.1.4024.55 and TwinCAT Runtime. Sorry for writing here on codesys forge, but since I found the only relevant topic here and since TwinCAT is almost the same with CODESYS in many applications, I chose to write here. I simply need to dynamically update image in visualization based on camera trigger (I am doing a machine vision application). Camera triggers an image, my program processes it (applies thresholding, draws contours etc...) and saves the processed image in the runtime location (the same one you were mentioning). This was done successfully. I need to make it work at runtime, while the program is executing and I need to refresh the image in the visualization each time camera triggers a new image and program processes it. When I create image element in the visualization and define the bitmap ID variable as STRING which contains the image ID defined in the image pool, then it displays the image in the image pool, but does not work at runtime, while the program is executing. I also used the Bitmap Version. I declared it in Global variable list as integer with initial value of 0 and wrote the variable in the bitmap version in the image element in visualization. Each time new image is saved to the runtime location, I wrote a program to increment Bitmap Version by 1. It increments and the image does not update in the visualization, unfortunately. I think that bitmap version is working correctly and deletes the cached image as it is supposed to, but the Image Pool does not update the image ID with the new image... the path to the image is always the same... only the actual image changes with the same file name. Image Pool is not dynamic and cannot refresh the image in the path to the actual one at runtime. How can I refresh the image ID in the image pool at runtime? Bitmap version only deletes cached image and reloads the image from the image ID, but the image ID has the same image, because image pool won't update at runtime. Do you know any solution to this problem?
Last updated: 2024-04-06
Post by ppix on Establishing TLS Connection with MQTT Broker using MQTT Client SL Package
CODESYS Forge
talk
(Post)
I’m currently working on establishing a TLS connection with an MQTT broker using the MQTT Client SL package in CODESYS. While I’ve successfully established communication with the broker without TLS, I'm encountering issues when trying to enable TLS. In the 'MQTT Explorer' application, I can easily upload the server certificate (.crt), client certificate (.crt), and client key (.key). However, in CODESYS, I can’t find a way to upload my client key (.key file). Here's a summary of my current setup: Certificates: I have uploaded both the client and server certificates to the certificate store under the 'Trusted Certificates' folder in the security screen. TLS Context Initialization: Despite setting the _sCommonName as the name of my client certificate, a new self-signed certificate is created and placed within the device’s certificates. I then need to manually move this certificate to the trusted certificates folder. This results in three certificates in my trusted certs folder: client cert, server cert, and the newly created cert. _ciDefaultCertInfo : MQTT.NBS.CERT_INFO := (psInfo := ADR(_sCommonName), udiSize := TO_UDINT(LEN(_sCommonName))); // CN of the certificate (common name) _sCipherList : MQTT.NBS.CIPHER_LIST := STRUCT(psList := ADR('HIGH'), udiSize := 4); // Cipher string see https://www.openssl.org/docs/man1.1.1/man1/ciphers.html _tlsContext : MQTT.NBS.TLSContext := ( sUseCaseName := _sCommonName, // A certificate is stored in the certificate store with the use case name. You can choose any name. Here we use the common name. ePurpose := MQTT.NBS.PURPOSE.CLIENT_SIDE, // For client certificates set this to NBS.PURPOSE.CLIENT_SIDE sTLSVersion := '1.3', // The TLS version sCipherList := _sCipherList, // Set the cipher list sHostname := sHostname, // The hostname of the broker udiVerificationMode := 2, // 2 => Active Peer verification ciCertInfo := _ciDefaultCertInfo, // Set the cert info itfCertVerifer := 0); // 0 => No Verifier mqttClient : MQTT.MQTTClient := (xUseTLS:=TRUE, itfTLSContext := _tlsContext, itfAsyncProperty := _asyncProperty); Additional Details: In the client FB, I’ve set uiPort:= 8883, xUseTLS:= TRUE, and configured itfTLSContext as mentioned above. The certificates are encrypted with SHA256RSA. sHostname is the IP address of my broker. I’ve attached a copy of the client FB, which shows straight lines where variables are assigned and boxes where they are not. I am currently trying this on the only 2 compatible versions of COSDESYS with my controller (V3.5.15.20 and V3.5.18.40) My Question: How do I correctly set up this mTLS connection? What might I be missing? Any guidance or suggestions would be greatly appreciated, especially considering I’ve already successfully established a non-TLS connection with the same broker. Thank you in advance for your help!
Last updated: 2024-06-19
Post by thommy54 on Lizenz wiederherstellen SP20
CODESYS Forge
talk
(Post)
Hallo Edwin, ich bräuchte mal eine schnelle Hilfe. ich testete einen zweiten Raspberry Pi 4 mit meinem Lizenzdongle eines laufenden Raspberry. Der 2. Raspberry ist als Redundanzlösung bei einem Crash gedacht. DIe Schwierigkeiten begannen, als ich mit dem Raspberry 4 V1.5 nicht mehr mit SP16 weiterarbeiten konnte. Ich updatede auf SP20.1. und die Schwerstarbeit begann. Das Image wurde rübergeschoben und alles auf dem zweiten Rechner soweit zum Laufen gebracht. Der Dongle wurde ebenfalls am 2. Rechner eingesteckt. Ob er überhaupt wirkte, kann ich nicht sagen, da für diesen Testfall Codesys so oft rauf und runter gefahren wurde, das die 2h-Grenze kaum erreicht wurde. Problem: Beim Zurückstecken des Dongles in den ursprücnglichen Rechner ist alles an Lizenzen weg. Der Lizenzmanager hat keinen Container mehr und der Befehl "lsusb" bringt nichts zurück. ich war der Meinung, das der Dongle genau für diesen Zweck gedacht war - die Lizenz von einem Rechner zum anderen mitzunehmen. Liege ich da falsch ? Wie komme ich nun wieder zu einem funktionfähigen Dongle ?? Weitere Versuche unternahm ich mit dem Wiederherstellen des Dongels. Dabei steckte ich ihn in meinen PC (Workstation) und siehe da, es werden noch 3 von ehemals (2020) 6 Lizenzzeilen angezeigt: (siehe Bild Problem_Lizenzen_Raspberry.jpg) Dann versuchte ich das Wiederherstellen über eine Lizenzaktualisierungsdatei vom Lizenzserver. Da kommt aber eine Datei mit anderem Dateityp (..WibuCmRaC) als im Lizenzmanager gesucht (WibuCmRaU). Die Datei ist dem Lizenzmanager auch nicht genehm (Bild Problem_Lizenzen_Raspberry_2.jpg). Nun steht Codesys auf besagtem Raspberry alle 2h still. Das soll die Lizenz doch verhindern. Angeblich soll seit SP13 auch kein eigenes Backup mehr nötig sein. Bis zum Erhalt des nicht brauchbaren Linzenzfiles hat da sja geklappt. Ich kann auch im Lizenzmanager keinen Punkt "Lizenz wiederherstellen" finden. Hat sich da mit SP20 etwas geändert? Wenn ich mir eine neue Lizenz hole - wie bringe ich sie auf den Dongle (der ja jetzt nicht "nagelneu" ist). Ich fürchte, das geht auch bloß schief. Im Voraus vielen Dank Thomas
Last updated: 2024-07-02
Post by jickisticki on Witch library?
CODESYS Forge
talk
(Post)
Crafting my Fellowship Personal Statement was like weaving the threads of my aspirations into a tapestry of words. Each sentence became a brushstroke, painting a vivid portrait of my journey and ambitions. Beyond being just a document, it became a mirror reflecting the depth of my experiences. Like a conductor guiding an orchestra, my personal statement was composed to resonate with my unique voice. In the realm of specialized opportunities, this statement serves as a compass, guiding me toward the next chapter of my professional growth. With each word, I felt the guidance of mentors shaping my story into an eloquent narrative.
Last updated: 2023-08-17
Post by janderson on OPC UA Server limitations, large array crashes runtime
CODESYS Forge
talk
(Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23
Post by rossanoparis on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
Hello at all I'd like to know how to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server. In the past, I tried to ask in "Forge" about this topic, but I could find neither help nor document informations about it. Reading the file "codesyscontrol.log" I see these logs OPC UA Server Started: Hostname: NTLRPICTRL01, Port: 4840 URL: opc.tcp://NTLRPICTRL01:4840 Loopbackadapter activated. **All available networkadapters are used.** Multithreading activated. 3 workers used. My controller, which is a Linux PC, has got two network cards eth0 and eth1 I whant to use the card with name "eth0" as a server for OPCUA and keep the "eth1" free for other stuffs. Is it possible ? Best regards Rossano
Last updated: 2023-08-25