Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing i´m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that i´m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now i´m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10
Post by mgabryel on Problems with CAN 2.0 comunication on Wago PLC (Codesys 3.5)
CODESYS Forge
talk
(Post)
Hello, I am trying to program CAN Bus comunication on WAGO PLC (more precisely on WAGO Touch Monitor model TP600). I am using for this purpose library "WagoAppCanLayer2" from Wago company. My IDE for programming this device is CODESYS V3.5 SP19 Patch 2 + (64-bit). My program is written in Structured text using function blocks from previously mentioned library. Here is code of this program: 1) Variables declarations: PROGRAM PLC_PRG VAR oOpenInterface : WagoAppCanLayer2.FbCanL2Open :=( udiBaudrate := 125000 ); xInterfaceIsOpen : BOOL; sInterfaceInfo : STRING; oReceive : WagoAppCanLayer2.FbCanRx29BitFrame :=( xBufferMode := FALSE, wCanId := 16#181 ); xRecv : BOOL; sReceiveInfo : STRING; oSend : WagoAppCanLayer2.FbCanTx29BitFrame :=( dwCanId := 16#100, //was 16#201 xRtrFrame := FALSE ); xSend : BOOL; sSendInfo : STRING; oCanDiag : WagoAppCanLayer2.FbCanErrorInfo; xRst : BOOL; aSendData : ARRAY [1..8] OF BYTE; bSendLen : BYTE; TON_0 : TON; TON_1 : TON; END_VAR 2) Program body: oOpenInterface( xEnable := NOT xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE ); sInterfaceInfo := oOpenInterface.oStatus.GetDescription(); xInterfaceIsOpen S= oOpenInterface.xValid AND NOT oOpenInterface.xError; oReceive( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xRxTrigger := xRecv ); sReceiveInfo := oReceive.oStatus.GetDescription(); IF NOT xRecv THEN IF oReceive.bRxNBytes > 0 THEN oReceive.aRxBuffer[1]; oReceive.aRxBuffer[2]; oReceive.aRxBuffer[3]; oReceive.aRxBuffer[4]; oReceive.aRxBuffer[5]; oReceive.aRxBuffer[6]; oReceive.aRxBuffer[7]; oReceive.aRxBuffer[8]; END_IF xRecv := TRUE; END_IF aSendData[1] := 224; aSendData[2] := 13; aSendData[3] := 14; aSendData[4] := 15; aSendData[5] := 222; aSendData[6] := 13; aSendData[7] := 14; aSendData[8] := 15; bSendLen := 8; TON_0(IN:= NOT TON_1.Q, PT:= T#2S , Q=>xSend, ET=> ); TON_1(IN:= TON_0.Q, PT:= T#2S , Q=>, ET=> ); oSend( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, aTxBuffer := aSendData, bTxNBytes := bSendLen, xTxTrigger := xSend ); sSendInfo := oSend.oStatus.GetDescription(); oCanDiag( xEnable := TRUE, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xTriggerResetCounter := xRst, xValid=> , xError=> , oStatus=> , wBusState=> , wBusDiag=> , uiRxOverflowsL2=> , uiTxOverflowsL2=> , uiRxOverflows=> , uiMsgTimeouts=> , uiBusOffs=> , uiBusWarnings=> ); Program first opens comunication on CAN 2 device and then periodically try send one CAN data frame. After starting program CAN 2 interface is properly open. The xSend variable is toggling with period 2s. When program sends data an "Tx overflow" error appears. When I am watching CAN_H line on DSub 9 socket i am not able to see proper CAN frames - see screenshot attached to this message. Could somebody help me determine what is wrong with this program. Best regards
Last updated: 2024-08-02
Post by critcho on WebVisu Numpad dialog - Dialogtitle not accepting string variable
CODESYS Forge
talk
(Post)
I have a WebVisu page which is re-used for multiple types of gas; it displays the alarm thresholds etc. for one gas at a time. I have an array of structures holding the set-points for each of the gasses. I'm trying to change the dialog title for the value input pop-up (VisuDialogs.Numpad). The Dialogtitle is set to Gas_Alarms.HighAlarmActivationLevelDialog, which is a string(50): When the gas type is changed (page first loaded, or prev/next buttons), METHOD Gas_Alarms.Update_Display_Variables is called, to update the strings used for the dialog titles so it shows GasName High Alarm Activation Level (EngineeringUnits), e.g. CO2 High Alarm Activation Level (PPM): HighAlarmActivationLevelDialog := Insert(' High Alarm Activation Level ()', EngineeringUnits, 30); HighAlarmActivationLevelDialog := Insert(HighAlarmActivationLevelDialog, GasName, 0); (That's not where the problem is, I'm just explaining why I'm using a variable dialogue title.) The variables used are definitely strings, but i'm always getting the error: "The type of the dialog title must be either STRING or WSTRING". I've tried moving HighAlarmActivationLevelDialog etc. to the GVL and also changing them to WSTRING, I even tried adding them to the structure array, but I always get the same error. Clearing the dialog title for that element removes the error - so I'm confident it's not a phantom error caused by something else. But I should be able to add these titles, can't just nuke them all to make it work. The MinVal and MaxVal for the Numpad are called from the array, e.g. GVL.Gas_Alarm_Configs[0].ScaledValueMIN, they are not getting an error. I am using array indexes 1 - 5 for the gasses, when I load the form or change gas, I copy the selected index to index 0 of the array, and values from Gas_Alarm_Configs[0].[ALL] are displayed on the page. When they hit save, I copy Gas_Alarm_Configs[0].[ALL] to Gas_Alarm_Configs[CurrentGasIndex].[ALL]. (ALL just means every element, I can't figure out how to display an asterix in this question... :) ) I've searched online for variable title dialog, but not found anything to help. Thanks for your help!
Last updated: 2025-05-29
Post by clarenced on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks
CODESYS Forge
talk
(Post)
Using codesys v3.5 SP21 Patch 1. We are using Visualization to display alarms. Other then the automatically created AlarmManagerTask, there is no code written to call AlarmStorage_Prg. Any ideas why we would be seeing this error in the log? The runtime actually shutdown. Not sure if that was caused by this error or not. 2025-08-03T02:45:35.444Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T03:48:15.294Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T04:38:11.557Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! * 2025-08-03T04:38:11.576Z, 0x0000010f, 8, 1, 0, #### Exception: SysSemEnter - Semaphore deadlock detected - owner thread died [tid:726740] - system may be in an inconsistent state. 2025-08-03T04:38:11.576Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-08-03T04:38:11.576Z, 0x00000001, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-08-03T04:40:12.308Z, 0x00000001, 1, 0, 35, CODESYS Control shutdown... 2025-08-03T04:40:13.436Z, 0x00000071, 1, 0, 13, Webserver stopped 2025-08-03T04:40:13.437Z, 0x00000114, 2, 1, 0, !!!! Warning: task_signalhandler_exit [MainTask] lost cycles: 14809 2025-08-03T04:40:13.497Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IecVarAccess</cmp>, <id>0x00001007</id> <ver>3.5.3.64</ver> 2025-08-03T04:40:13.506Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>AlarmMgr</cmp>, <id>0x00001012</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.513Z, 0x00000071, 2, 0, 14, !!!! Warning: Unbalanced calls to WebServerRequestRunning/WebServerReleaseRunning 2025-08-03T04:40:13.513Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IECVisualization</cmp>, <id>0x0000100c</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:50:17.708Z, 0x00000001, 1, 0, 36, CODESYS Control shutdown done
Last updated: 2025-08-04
Post by dandyk on Dynamic Images
CODESYS Forge
talk
(Post)
Hello, I have very similar problem, but it seems that your solution does not work for me. I am using TwinCAT XAE Shell v3.1.4024.55 and TwinCAT Runtime. Sorry for writing here on codesys forge, but since I found the only relevant topic here and since TwinCAT is almost the same with CODESYS in many applications, I chose to write here. I simply need to dynamically update image in visualization based on camera trigger (I am doing a machine vision application). Camera triggers an image, my program processes it (applies thresholding, draws contours etc...) and saves the processed image in the runtime location (the same one you were mentioning). This was done successfully. I need to make it work at runtime, while the program is executing and I need to refresh the image in the visualization each time camera triggers a new image and program processes it. When I create image element in the visualization and define the bitmap ID variable as STRING which contains the image ID defined in the image pool, then it displays the image in the image pool, but does not work at runtime, while the program is executing. I also used the Bitmap Version. I declared it in Global variable list as integer with initial value of 0 and wrote the variable in the bitmap version in the image element in visualization. Each time new image is saved to the runtime location, I wrote a program to increment Bitmap Version by 1. It increments and the image does not update in the visualization, unfortunately. I think that bitmap version is working correctly and deletes the cached image as it is supposed to, but the Image Pool does not update the image ID with the new image... the path to the image is always the same... only the actual image changes with the same file name. Image Pool is not dynamic and cannot refresh the image in the path to the actual one at runtime. How can I refresh the image ID in the image pool at runtime? Bitmap version only deletes cached image and reloads the image from the image ID, but the image ID has the same image, because image pool won't update at runtime. Do you know any solution to this problem?
Last updated: 2024-04-06
Post by sturmghost on Initialization of visualization variables and cyclic code execution
CODESYS Forge
talk
(Post)
I'm looking for a smart and short way to implement initialization of visualization variables depending on the visualization input. For an easy example consider a rectangle which rests at XPos := 0 when the input state is false and at XPos := 50 when the input state is true. My visualization variables look like this: VAR_IN_OUT State : BOOL; END_VAR VAR XPos : INT; END_VAR I put this rectangle via a visualization frame element into another visualization and link a frame reference variable with the state to it. If the variable is true, the rectangle should rest at XPos := 50 and false at XPos := 0 at visualization init but how should I assign the 50 or 0 to the internal visualization variable XPos? I would need some init-methode for the visualization but I dont want a global init-method for such tasks. I want to do it inside of the visualization element but I can't see any solution for this? It would be good to be able to define ST-code within the visualization element which runs cyclic at each VISU_TASK task-cycle then I could just check the input state and change the XPos accordingly. Does someone have a solution?
Last updated: 2023-10-01
Post by berto on Opening PDF in Web Browser in Target Visu HMI
CODESYS Forge
talk
(Post)
Hi everybody, I've been facing problems with the PDF visualization in Web Browser. I am trying to open a pdf file called 'sample.pdf' which I manually saved inside PlcLogic/visu folder. I am setting the web browser URL as: 'http://127.0.0.1:8080/sample.pdf' but I get 'refused connection'. I got a similar error trying to open https sites and I discovered that I can only open http websites. Opening 'http://de.wikipedia.org' everything works fine. I also tried to check using code whether the sample.pdf is present in the directory. Unfortunately, when I try to read directories of 'PlcLogic' I get file FILE_OPERATION_DENIED (I am using File.DirList). I would like to be able to open PDF files in web browser. Possibly to move new PDF files in the folder as my customer wants to display different pdf manuals on the hmi. Here you find some screenshots and my .project. I am using Codesys 3.5.19.70. Best regards, Berto
Last updated: 2024-07-11
Post by dogulas on OPC UA C# client connecting to OPC UA CODESYS server
CODESYS Forge
talk
(Post)
Ok, I have a simple test environment. From C#, using OPC UA, I can read DINTs, write DINTs, read Structs, but when I try to write a struct I get BadNotWritable. I am using Communication Manager, OPC UA Server, and IEC Symbol Publishing. I have a struct defined with one single DINT in it. The instance of the struct is in GVL. The struct is marked read/write in IEC Symbol Publishing. Any ideas? Pointers are welcome. public static async Task WriteStructA(byte[] structAData) { if (_session == null) throw new Exception("session is null"); // create a RequestHeader RequestHeader requestHeader = new RequestHeader { Timestamp = DateTime.UtcNow, TimeoutHint = 30000 // timeout in milliseconds }; // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA", 5), structAData ); // create a WriteValue object to hold the value to be written WriteValue writeValue = new WriteValue { NodeId = _structANodeId, AttributeId = Attributes.Value, Value = new DataValue(extensionObject) }; // put the WriteValue object into a WriteValueCollection object WriteValueCollection writeValueCollection = new WriteValueCollection() { writeValue }; // perform the write operation asynchronously WriteResponse writeResponse = await _session.WriteAsync( requestHeader, writeValueCollection, CancellationToken.None ); // check the result of the write operation if (writeResponse.Results[0] != StatusCodes.Good) throw new Exception("Write failed: " + writeResponse.Results[0]); }
Last updated: 2024-12-17
Post by timvh on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
You can get the state by just using the name of your node (same name as in device tree): VAR etcState: IoDrvEthercatDriverLib.ETC_SLAVE_STATE; END_VAR etcState := EJ1100.wState; Alternatively, you can iterate through the device tree to get the status of all (Ethercat) nodes. See here an example (no guarantee it works, just give as suggestion): PROGRAM P_IO_State VAR CONSTANT uiMAX_NR_OF_TERMINALS : UINT := 100; END_VAR VAR // general device diagnosis // can only be used when the Device - PLC Settings - Advanced settings - enable diagnosis for devices is enabled // this will add the DED library coupler: DED.INode; terminal: DED.INode; aDeviceState: ARRAY[0..uiMAX_NR_OF_TERMINALS - 1] OF DED.DEVICE_STATE; uiTerminalCount : UINT; uiIndex : UINT; // for each terminal check if it implements device diagnostics xQueryResult: BOOL; itfDevice : DED.IDevice2; xDiagAvailable: BOOL; eError: DED.ERROR; xEverythingOK: BOOL; END_VAR uiTerminalCount := 0; // start at the top of the device tree with the first EtherCAT coupler coupler := EtherCAT_Master.FirstChildNode; WHILE coupler <> 0 DO // for each coupler that is found start at the first terminal terminal := coupler.FirstChildNode; WHILE terminal <> 0 AND uiTerminalCount < uiMAX_NR_OF_TERMINALS - 1 DO // for each terminal that is found get the status through the device diagnosis interface xQueryResult := __QUERYINTERFACE(terminal, itfDevice); IF xQueryResult THEN aDeviceState[uiTerminalCount] := itfDevice.GetDeviceState(xDiagnosisInfoAvailable => xDiagAvailable, eError => eError); uiTerminalCount := uiTerminalCount + 1; END_IF terminal := terminal.NextSiblingNode; END_WHILE coupler := coupler.NextSiblingNode; END_WHILE uiIndex := 0; xEverythingOK := TRUE; WHILE uiIndex < uiTerminalCount DO IF aDeviceState[uiIndex] <> DED.DEVICE_STATE.RUNNING THEN xEverythingOK := FALSE; EXIT; END_IF uiIndex := uiIndex + 1; END_WHILE
Last updated: 2025-02-06
Post by pistola on C0357: "GetNextClient" is obsolete, use VisuUtils instead
CODESYS Forge
talk
(Post)
I'm having some troubles with this same issue and I'm wondering if someone can help me out. On a settings visual I allow the operator to enter some values however if they activate the page change button it will change the change with the Numpad dialog open. Since I'm using Visuelems.CURRENTVISU to change the pages I came across this code noted below for determining if the Numpad dialog was active. This code worked great however now in 3.5.19 it's now obsolete. I've tried following the directions in the attached program above however I can't see to get it to work in my program. Can anyone provide some help to determine if a dialog is open? FUNCTION Check_Dialog_Open : Bool VAR_INPUT sDialogName : STRING; // Input variable for the name of the dialog END_VAR VAR pstClientData : POINTER TO VisuElems.VisuStructClientData; // Pointer to the client data structure itfDialogManager : VisuElems.IDialogManager; // Interface for the dialog manager itfMyDialog : VisuElems.IVisualisationDialog; // Interface for the specific visualisation dialog END_VAR // Begin the iteration over the client manager VisuElems.g_ClientManager.BeginIteration(); // Loop through each client until no more clients are found WHILE (pstClientData := VisuElems.VisuElemBase.g_ClientManager.GetNextClient()) <> 0 DO // Get the dialog manager interface itfDialogManager := VisuElems.g_VisuManager.GetDialogManager(); // Get the specific dialog interface using the dialog name itfMyDialog := itfDialogManager.GetDialog(sDialogName); // Check if the dialog is open for the current client Check_Dialog_Open := VisuDialogs.VisuDlgUtil_IsDialogOpen(itfMyDialog, pstClientData, itfDialogManager); // If the dialog is open, exit the loop IF Check_Dialog_Open THEN EXIT; END_IF END_WHILE
Last updated: 2025-03-27
Post by alexgooi on Modbus writing on value change
CODESYS Forge
talk
(Post)
Hi Duvan, You could make this in 1 single object (FB), Indeed don't use a function for this beacuse you need some memory to keep the old value. For i := 0 TO 200 BY 1 DO //Check if the value has been changed IF Old_Value[i] <> Value[i] THEN //Set the trigger to TRUE Trigger[i] := TRUE; Old_Value[i] := Value[i]; END_IF END_FOR If you define the Value array as an In_Out and the Trigger as an In_Out you arn't claiming any aditional memory to your system. You ofcourse then need to add some code arround it that does something with the trigger and writes it back to FALSE again. If you want more flexability you also could use pointers instead of using the IN_OUT FOR i := 0 TO 200 BY 1 DO address := address_Input + i * SIZEOF(*Put type here); IF Address^ <> Old_Value[i] THEN Trigger[i] := TRUE; Old_Value[i] := Address^; END_IF END_FOR
Last updated: 2024-04-02
Post by cmj-icsys on Custom configure tab in device editor
CODESYS Forge
talk
(Post)
Hi everyone, I’m developing a custom CODESYS I/O driver for my company’s device, and I’ve been studying the example projects in CODESYS V3.5 SP20 Patch 5. In the IOMappingExample.project, I noticed that EtherCAT devices provide additional configuration tabs in the Device Editor, such as General, Process Data, etc. However, for custom I/O driver examples (based on IoDrv), the Device Editor only shows the default tabs like <devicename> I/O Mapping or <devicename> Parameters.</devicename></devicename> I’d like to create custom tabs or configuration pages in the Device Editor (e.g., “General Settings”, “Communication”, etc.) to allow users to configure parameters in a more structured way. Could anyone explain: How to define and register custom tabs or UI pages in the Device Editor? What tools or SDKs are needed to create UI elements such as combo boxes or check boxes? How to bind those UI controls to device parameters defined in the XML (device description)? Any example, SDK reference, or documentation link would be really helpful. Thanks in advance!
Last updated: 2025-10-20
Post by meke001 on Visualisierungswerkzeuge
CODESYS Forge
talk
(Post)
Hallo zusammen, ich habe ein hartnäckiges Problem mit der CODESYS-Visualisierung und hoffe auf eure Expertise. In meinem Projekt wird die Toolbox ("Werkzeuge") für die Visualisierung komplett leer angezeigt, es lassen sich also keine Basis-Elemente wie Rechtecke oder Kreise in die Zeichenfläche ziehen. Mein System: CODESYS V3.5 SP22 Patch 2 (64-bit) Device / Compiler-Version: 3.5.22.20 Das Kuriose:Das eigentliche Projekt läuft absolut einwandfrei. Mein Programmcode lässt sich ohne Probleme übersetzen, die SPS-Logik funktioniert fehlerfrei und auch die Simulation läuft einwandfrei durch. Nur das "Gesicht" des Projekts fehlt. Zwischendurch tauchte in den Meldungen der Fehler auf: Die Bibliothek '#System_VisuElems' konnte nicht aufgelöst werden. Was ich bereits zur Fehlerbehebung versucht habe: Installer-Check: Im CODESYS Installer geprüft, ob das Add-on "CODESYS Visualization" installiert ist (ist vorhanden und aktiv). Profil erzwungen: Im Visualisierungsmanager das Visualisierungsprofil manuell auf die aktuellste Version gesetzt. Gerät aktualisiert: Das Device im Projektbaum per Rechtsklick sauber auf die Version 3.5.22.20 hochgezogen. Clean Build: Mehrfach "Alles bereinigen" ausgeführt und neu übersetzt. Neues Projekt: Selbst wenn ich ein komplett neues Standardprojekt anlege, fehlen die Werkzeuge in der Visualisierung weiterhin. Hat jemand von euch eine Idee, woran das noch liegen könnte? Gibt es unter Windows eventuell einen versteckten Cache-Ordner für die Visualisierungs-Bibliotheken, den man manuell leeren muss? Für jeden Tipp wäre ich sehr dankbar! Viele Grüße
Last updated: 2026-06-15
Post by francesco86 on Script python for write in a file Project information
CODESYS Forge
talk
(Post)
Dear all, My python script can read a Codesys project and save in file the different POU, but the problem is that I don't able to read the project info from the obj list. Following of this message there is my python script. Can you help my? Best regards Francesco # encoding:utf-8 # We enable the new python 3 print syntax from __future__ import print_function import os import shutil import time import sys from datetime import datetime print("--- Saving files in the project: ---") print("sys.argv: ", len(sys.argv), " elements:") for arg in sys.argv: print(" - ", arg) if (len(sys.argv)>1): folderExportName = sys.argv[1] print(" folderExportName: ", folderExportName) exportPath = sys.argv[2]+ sys.argv[3]+ "\\"+ sys.argv[1] print(" File path: ", exportPath) # git has_repo=False #save_folder=r'E:\Tmp\ControlPlugins\ControlPlugins\Export' save_folder = exportPath if not os.path.exists(save_folder): os.makedirs(save_folder) else: a=os.listdir(save_folder) for f in a: if not f.startswith("."): sub_path= os.path.join(save_folder,f) if os.path.isdir(sub_path): shutil.rmtree(sub_path) else: os.remove(sub_path) elif f==".git": has_repo=True info={} type_dist={ '792f2eb6-721e-4e64-ba20-bc98351056db':'pm', #property method '2db5746d-d284-4425-9f7f-2663a34b0ebc':'dut', #dut 'adb5cb65-8e1d-4a00-b70a-375ea27582f3':'lib', #lib manager 'f89f7675-27f1-46b3-8abb-b7da8e774ffd':'m', #method no ret '8ac092e5-3128-4e26-9e7e-11016c6684f2':'act', #action '6f9dac99-8de1-4efc-8465-68ac443b7d08':'pou', #pou '6654496c-404d-479a-aad2-8551054e5f1e':'itf', #interface '738bea1e-99bb-4f04-90bb-a7a567e74e3a':'', #folder 'ffbfa93a-b94d-45fc-a329-229860183b1d':'gvl', #global var '5a3b8626-d3e9-4f37-98b5-66420063d91e':'prop', #property '2bef0454-1bd3-412a-ac2c-af0f31dbc40f':'tl', #textlist '63784cbb-9ba0-45e6-9d69-babf3f040511':'gtl', #global textlist '225bfe47-7336-4dbc-9419-4105a7c831fa':'dev', #device 'ae1de277-a207-4a28-9efb-456c06bd52f3':'tc', #task configuration 'f8a58466-d7f6-439f-bbb8-d4600e41d099':'m', #method with ret '261bd6e6-249c-4232-bb6f-84c2fbeef430':'gvl', #gvl_Persistent '98a2708a-9b18-4f31-82ed-a1465b24fa2d':'task', #task '085afe48-c5d8-4ea5-ab0d-b35701fa6009':'progInfo'#project information }; def save(text,path,name,tp): if not tp: tp='' else: tp='.'+tp+'.txt' with open(os.path.join(path,name+tp),'w') as f: f.write(text.encode('utf-8')) def print_tree(treeobj, depth, path): global info #record current Path curpath=path isfolder=False t='' #text tp='' #type # get object name name = treeobj.get_name(False) id = treeobj.type.ToString() if id in type_dist: tp = type_dist[treeobj.type.ToString()] #Print all type of objects #print("--Name: ", tp) else: info[id]=name if treeobj.is_device: deviceid = treeobj.get_device_identification() t = 'type='+str(deviceid.type) +'\nid=' +str(deviceid.id) + '\nver='+ str(deviceid.version) if tp == "progInfo": print("-- There is prog info, ", tp) print("-- It has textual declaration: , ", treeobj.has_textual_declaration) print("-- It has textual implementation: , ", treeobj.has_textual_implementation) print("-- It is folder: , ", treeobj.is_folder) print("-- It is children: , ", treeobj.get_children(False)) print("-- It is children len: , ", len(treeobj.get_children(False))) print("-- It is progInfo type: , ", type(treeobj.ScriptProject)) #for child in treeobj.get_children(False): # print_tree(child, depth+1,curpath) try: if treeobj.is_folder : #system.ui.prompt('folder:'+u, PromptChoice.YesNo, PromptResult.Yes) isfolder=true pass except: pass if treeobj.has_textual_declaration : t=t+'(*#-#-#-#-#-#-#-#-#-#---Declaration---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_declaration t=t+a.text if treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---Implementation---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_implementation t=t+a.text if treeobj.has_textual_declaration and not treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---NOT Implementation visible---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' if treeobj.is_task : exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.task')) if treeobj.is_libman: exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.lib')) if treeobj.is_textlist: treeobj.export(os.path.join(curpath,name+'.tl')) children = treeobj.get_children(False) if children or isfolder: if tp: curpath=os.path.join(curpath,name+'.'+tp) else: curpath=os.path.join(curpath,name) if not os.path.exists(curpath): os.makedirs(curpath) if t: save(t,curpath,name,tp) for child in treeobj.get_children(False): print_tree(child, depth+1,curpath) for obj in projects.primary.get_children(): print_tree(obj,0,save_folder) with open(os.path.join(save_folder,'ExportInfo.txt'),'w') as f: now = datetime.now() infTimeExecution = now.strftime("%Y-%m-%d %H:%M:%S") f.write("Export date and time: "+infTimeExecution + "\r\n" + str(info)) print("--- Script finished. ---") #system.ui.info('save ok') projects.primary.close()
Last updated: 2024-04-30
Post by francesco86 on Script python for write in a file Project information
CODESYS Forge
talk
(Post)
Dear all, My python script can read a Codesys project and save in file the different POU, but the problem is that I don't able to read the project info from the obj list. Following of this message there is my python script. Can you help my? Best regards Francesco # encoding:utf-8 # We enable the new python 3 print syntax from __future__ import print_function import os import shutil import time import sys from datetime import datetime print("--- Saving files in the project: ---") print("sys.argv: ", len(sys.argv), " elements:") for arg in sys.argv: print(" - ", arg) if (len(sys.argv)>1): folderExportName = sys.argv[1] print(" folderExportName: ", folderExportName) exportPath = sys.argv[2]+ sys.argv[3]+ "\\"+ sys.argv[1] print(" File path: ", exportPath) # git has_repo=False #save_folder=r'E:\Tmp\ControlPlugins\ControlPlugins\Export' save_folder = exportPath if not os.path.exists(save_folder): os.makedirs(save_folder) else: a=os.listdir(save_folder) for f in a: if not f.startswith("."): sub_path= os.path.join(save_folder,f) if os.path.isdir(sub_path): shutil.rmtree(sub_path) else: os.remove(sub_path) elif f==".git": has_repo=True info={} type_dist={ '792f2eb6-721e-4e64-ba20-bc98351056db':'pm', #property method '2db5746d-d284-4425-9f7f-2663a34b0ebc':'dut', #dut 'adb5cb65-8e1d-4a00-b70a-375ea27582f3':'lib', #lib manager 'f89f7675-27f1-46b3-8abb-b7da8e774ffd':'m', #method no ret '8ac092e5-3128-4e26-9e7e-11016c6684f2':'act', #action '6f9dac99-8de1-4efc-8465-68ac443b7d08':'pou', #pou '6654496c-404d-479a-aad2-8551054e5f1e':'itf', #interface '738bea1e-99bb-4f04-90bb-a7a567e74e3a':'', #folder 'ffbfa93a-b94d-45fc-a329-229860183b1d':'gvl', #global var '5a3b8626-d3e9-4f37-98b5-66420063d91e':'prop', #property '2bef0454-1bd3-412a-ac2c-af0f31dbc40f':'tl', #textlist '63784cbb-9ba0-45e6-9d69-babf3f040511':'gtl', #global textlist '225bfe47-7336-4dbc-9419-4105a7c831fa':'dev', #device 'ae1de277-a207-4a28-9efb-456c06bd52f3':'tc', #task configuration 'f8a58466-d7f6-439f-bbb8-d4600e41d099':'m', #method with ret '261bd6e6-249c-4232-bb6f-84c2fbeef430':'gvl', #gvl_Persistent '98a2708a-9b18-4f31-82ed-a1465b24fa2d':'task', #task '085afe48-c5d8-4ea5-ab0d-b35701fa6009':'progInfo'#project information }; def save(text,path,name,tp): if not tp: tp='' else: tp='.'+tp+'.txt' with open(os.path.join(path,name+tp),'w') as f: f.write(text.encode('utf-8')) def print_tree(treeobj, depth, path): global info #record current Path curpath=path isfolder=False t='' #text tp='' #type # get object name name = treeobj.get_name(False) id = treeobj.type.ToString() if id in type_dist: tp = type_dist[treeobj.type.ToString()] #Print all type of objects #print("--Name: ", tp) else: info[id]=name if treeobj.is_device: deviceid = treeobj.get_device_identification() t = 'type='+str(deviceid.type) +'\nid=' +str(deviceid.id) + '\nver='+ str(deviceid.version) if tp == "progInfo": print("-- There is prog info, ", tp) print("-- It has textual declaration: , ", treeobj.has_textual_declaration) print("-- It has textual implementation: , ", treeobj.has_textual_implementation) print("-- It is folder: , ", treeobj.is_folder) print("-- It is children: , ", treeobj.get_children(False)) print("-- It is children len: , ", len(treeobj.get_children(False))) print("-- It is progInfo type: , ", type(treeobj.ScriptProject)) #for child in treeobj.get_children(False): # print_tree(child, depth+1,curpath) try: if treeobj.is_folder : #system.ui.prompt('folder:'+u, PromptChoice.YesNo, PromptResult.Yes) isfolder=true pass except: pass if treeobj.has_textual_declaration : t=t+'(*#-#-#-#-#-#-#-#-#-#---Declaration---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_declaration t=t+a.text if treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---Implementation---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' a=treeobj.textual_implementation t=t+a.text if treeobj.has_textual_declaration and not treeobj.has_textual_implementation: t=t+'(*#-#-#-#-#-#-#-#-#-#---NOT Implementation visible---#-#-#-#-#-#-#-#-#-#-#-#-#*)\r\n' if treeobj.is_task : exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.task')) if treeobj.is_libman: exports=[treeobj] projects.primary.export_native(exports,os.path.join(curpath,name+'.lib')) if treeobj.is_textlist: treeobj.export(os.path.join(curpath,name+'.tl')) children = treeobj.get_children(False) if children or isfolder: if tp: curpath=os.path.join(curpath,name+'.'+tp) else: curpath=os.path.join(curpath,name) if not os.path.exists(curpath): os.makedirs(curpath) if t: save(t,curpath,name,tp) for child in treeobj.get_children(False): print_tree(child, depth+1,curpath) for obj in projects.primary.get_children(): print_tree(obj,0,save_folder) with open(os.path.join(save_folder,'ExportInfo.txt'),'w') as f: now = datetime.now() infTimeExecution = now.strftime("%Y-%m-%d %H:%M:%S") f.write("Export date and time: "+infTimeExecution + "\r\n" + str(info)) print("--- Script finished. ---") #system.ui.info('save ok') projects.primary.close()
Last updated: 2024-04-30
Post by thejesh on WebVisu: switch-frame destroys and rebuilds referenced visualization - is retention configurable?
CODESYS Forge
talk
(Post)
Hi, HTML5 Conrtrol elements on CODESYS V3.5 SP22 Patch 2, WebVisu only (no TargetVisu). The client is Chromium 147 in kiosk mode on a Raspberry Pi CM5 panel; the runtime is CODESYS Control Win V3 x64/CODESYS Control RTE V3 x64 on a separate IPC. I have measured that changing a Frame element's switch-frame variable destroys the currently referenced visualization and fully rebuilds it on return, including all embedded HTML5 controls. We would like to know whether this lifecycle is configurable. Measurement 1: Curently, our production page contains a good number of custom HTML5 controls and will only increase , each of which the WebVisu client instantiates as a separate about:srcdoc iframe. I counted live targets via the Chromium remote debugging endpoint (curl http://localhost:9222/json/list) before and after switching. Production displayed (index 0) 108 iframes Switched to a light page (index 1) 46 iframes Switched back to Production 108 iframes 62 controls are destroyed on leaving the page and re-instantiated on return. Observed latency was approximately 2.5 -5s away from the heavy page and approximately 4.0 -5 s back to it. This was measured with the panel otherwise idle: 2.8% system CPU, 97.1% idle, 2 h 56 min uptime, no remote-desktop session running, hardware acceleration confirmed active in chrome://gpu. I had previously measured the same behaviour under a much higher CPU load and have since resolved that load separately (VISU_TASK cycle period), so I am confident the rebuild is the frame lifecycle itself and not CPU starvation. Measurement 2 — frame offset instead of switch index I then displayed the same overlay page by a different mechanism. Instead of using a switch-frame index, I placed the page in a fixed Frame parked off-screen below the visible canvas, and drive its Y offset from an INT in Structured Text to move it into view. With this approach the overlay appears immediately, the production page underneath is never torn down and keeps updating, and no visualization is destroyed or rebuilt in either direction. The iframe count does not change at any point. This is the same visualization, containing the same HTML5 controls, as in Measurement 1 — the only difference is how it is brought on screen. So the rebuild appears to be a property of the switch-frame mechanism specifically, not of the page or its control count. Questions: Is the destroy-and-rebuild behavior on switch-frame the intended and documented lifecycle for WebVisu? Is there any setting, property or client option that causes a referenced visualization to remain instantiated when it is not the active index — the equivalent of keeping it mounted but not displayed? Does the runtime or client offer any form of caching or pre-instantiation for referenced visualizations, so that a return switch does not pay the full construction cost? Is the cost specific to HTML5 controls, or would the same rebuild occur with an equivalent number of native visualization elements? We ask because it would inform whether reducing our HTML5 control count is a viable solution. Is there a recommended pattern for showing a full-screen page over a live production screen without tearing the production screen down? My current workaround is to keep every page permanently instantiated and move it on and off screen by driving a frame offset variable, which avoids the rebuild entirely but means every page stays live and consumes client resources for the life of the session. This works, but I would prefer to use the supported mechanism if one exists. Any help on this is greatly appreciated. Thank you!
Last updated: 2026-08-07
Post by tk096 on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work). In general: - Motion function blocks have to be called until they report 'Done', 'Error', 'CommandAborted' or a subsequent motion FB with BufferMode=Aborting is started in the current cycle. - Setting the Execute input to FALSE will not abort any ongoing motion of the motion function block. For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. I think the error SMC_FB_WASNT_CALLED_DURING_MOTION is only a follow-up (and misleading) error that results from the axis not being in operational state anymore (bus problems). Is there an error 'regulator or start not set' in the device log before the error 'motion generating FB wasn't called for at least one cycle'? Which error does the respective function block (Halt.ErrorId) report?
Last updated: 2024-07-22
Post by edson-bueno on SysProcess Execute Command unable to run commands with special characters
CODESYS Forge
talk
(Post)
Hi, I found the same issue, and I fixed with this steps: 1st go to codesys .cfg file. sudo nano CODESYSControl.cfg Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll Now we need to grant codesys root rights on Linux. Step 1: Create or edit the systemd override configuration: sudo systemctl edit codesyscontrol In the editor that opens, insert: [Service] User=root Save and exit: Press Ctrl+O to save Press Ctrl+X to exit Step 2: Reload systemd and reboot To apply the override: sudo systemctl daemon-reexec sudo systemctl daemon-reload sudo reboot Step 3: Confirm CODESYS is running as root After reboot, open the terminal and run: ps aux | grep codesyscontrol You should see something like: root 1234 ... /opt/codesys/bin/codesyscontrol.bin ... If instead it shows admin or another user, the override was not applied correctly. Step 4: (Optional) Confirm from within CODESYS In your CODESYS project, insert this test code to run the Linux command whoami: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR refCommand REF= sCommand; refOutput REF= sOutput; SysProcessExecuteCommand2( pszCommand := refCommand, pszStdOut := refOutput, udiStdOutLen := SIZEOF(sOutput), pResult := ADR(resultCmd) ); Notes & Warnings This method gives full system access to the CODESYS runtime — do not expose this system to the public network without protection. Do not use sudo in commands inside CODESYS when the runtime is already running as root. @tomas111, in case you want to read the temperatur, use this command: sCommand:STRING:='/usr/bin/vcgencmd measure_temp';
Last updated: 2025-05-20
Post by dnordenberg on BOOL variable in OPC UA and modbus simultaneously
CODESYS Forge
talk
(Post)
How can I have an BOOL variable that is read/write in both modbus TCP server and from OPC UA at the same time? Variables with %MX.n %QX.n addressing which is used for BOOL/coils in modbus server is not allowed in OPC UA symbol list on Schneider M251 controllers. I have already asked on Schneiders forum but there are not a lot of codesys experts over there :( So OPC symbols can't have a address and the modbus TCP server needs a address. So how should I do it then? It seems like an impossible combination. Since I want read/write access from both ways I can't just simply make a second variable and assign it the value of another since it would be a one way assignment. I also tried using VAR_CONFIG which then makes the address syntax %Q or %M in my main variable list and that fools OPC UA Symbol Configuration to allow it and then I add the complete %MX.n address of it in the VAR_CONFIG list. This semi works, I can toggle the BOOL from modbus but the OPC UA symbol seems to be read only. It displays symbol status but nothing happens when I toogle it. I think I need another way to have the variables and symbols pointing to the same bits in memory... My plan B is to write a BOOL array compare FB that saves a history bit from previous cycle and if that does not match current status at next cycle for either the OPC symbol or the modbus variable then it copies the new status over to the other. Maybe ugly but it's like my last alternative. Kind regards David
Last updated: 2025-07-14
Post by westcountryewe on ac_persistence not working when creating a Boot Application but works with a Direct Download to the PLC
CODESYS Forge
talk
(Post)
I am using V3.5 SP18 Patch 5. I have noticed that when I Create a Boot Application from CODESYS, and upload this to my PLC via a USB stick the AC_Persistence does not work and none of my values that are in my PersistenceChannel are retained. However, if I connect direct to my PLC and I perform a direct download of my CODESYS program, my values that are in my PersistenceChannel are retained and work as they should. This makes me wonder if there are files that are missing when a Boot Application is created. I have tried taking a backup of my configuration files after performing a direct download, which gives me the plclog.zip folder, and appears to have the ac_persistence folder present within the file structure, however when I replace the plclogic.zip with the same folder that was created when I created a Boot Application, it still does not work but I wonder whether this is because the ac_persistence folder isn't stored in the correct location for reading. The .app and .crc files are embedded within the plclogic.zip folder, which obviously when uploading need to be standalone files in the root directory of the USB, so the intention there is clearly to extract the .app and .crc files and put them into the correct location within the USB. I wonder if it could be the same for the ac_persistence folder? I have tried moving it to different locations but none have worked. Has anybody else discovered a fix for this? I know the short-term solution is to do a direct download to the PLC but there are some logistical reasons why this isn't neccesarily the best solution for us.
Last updated: 2024-02-27
Post by wildcard on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13
Post by t-probst on Strong Private Key Protection for Encryption Certificates
CODESYS Forge
talk
(Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22
Post by fabian on v3.5 SP19 - Modbus TCP Devices - Channel Limit?
CODESYS Forge
talk
(Post)
Hi all, Is there an update on this topic? Same problem here, I can not add more than 10 Modbus-Slave channels. Is there a workaround? Many thanks! Fabian Codesys 3.5.19 SP2, Modbus 4.3.0.0, Name: Modbus TCP Slave Hersteller: 3S - Smart Software Solutions GmbH Kategorien: Modbus TCP Slave Typ: 89 ID: 0000 0005 Version: 4.1.0.0 Bestellnummer: - Beschreibung: Ein Geraet, das als Slave fĂĽr einen Modbus TCP Master konfiguriert ist. Version Konfiguration 3.5.11.0
Last updated: 2023-08-28
Post by martinlithlith on Relay board / relays for raspberry pi 3 b+
CODESYS Forge
talk
(Post)
hi! im planning a project on a raspberry with Codesys. For this I'll need a number of relays to control heating and fans, all a max of 24v and about 2a. How would i know if the board / relays i buy will be working with Codesys? Does every hat work or does it need a library/driver? is there a list of drivers/libraries created? as this is a hobby project all tips on a relay board or single boards that works with codesys and not to expensive are very welcome.
Last updated: 2023-09-03
Post by dasch on eCockpit - unable to start simulation
CODESYS Forge
talk
(Post)
This is a known bug in e!Cockpit. See Release notes of V 1.11: 1 e!Cockpit Release Version 1.11 (2022-07) ATTENTION: If a library that uses asynchronous tasks (e.g. WagoAppConfigTool, WagoAppCloud or function modules such as Dali-Master) is dragged into the project, the simulation cannot be started. It is already sufficient to add the library to the project (an FB does not even have to be instantiated). I guess you are using one of these libraries/modules in your project. We e.G. often use PWM modules, these are also affected.