Post by caualima on AI + Programming CODESYS Forge talk (Post)
What do you think about having an AI Agent specialized in ST programming in Codesys? I see this saving hours and hours of work for those who program on a daily basis.
Last updated: 2026-01-24

Post by eschwellinger on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. CODESYS Forge talk (Post)
check with the CODESYS Installer er if you are on latest Visuversion. 4.9.1.0
Last updated: 2026-01-27

Post by altin on No source code available for this object CODESYS Forge talk (Post)
Hello, I get same error message but pointing at different library. The error appears when im trying to scroll an AlarmTable on a thouch screen (ifm CR1204). Anyone knows what causing this and how to procceed? Many thanks in advance,
Last updated: 2026-02-16

Post by husarz17 on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
I need the same issue. In my application TCP server on raspberry (codesys) should have UnitID 1. But it only works when I am requesting with UnitID 255. And my application can't work with this parameters...
Last updated: 2026-03-31

Post by nulltrace on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
Hey Husarz, thanks for your Message, now i understand your Problem, also able to reproduce that. Pls. give me a Short Time to Check some stuff on this, i'll come back to this Topic with news ASAP. Greetings
Last updated: 2026-04-03

Post by malie on Issue with library updates CODESYS Forge talk (Post)
Hello, i got the same problem, but on my site it started with version 3.5.21, with version 3.5.19.7 it worked like a charm. How get the old behavior back? Or how to reload the librarys in an open project/library manually?
Last updated: 2026-04-24

Post by reinier-geers on Network variable stops sending CODESYS Forge talk (Post)
What version. 20.5 ? ive got also problems wiyth that version. Online change, it hangs itself after one hour. Then one project can problems. Ive change display with 21.0 . At home i turned on the 20.5 display. After 1 hour i goes to stop.
Last updated: 2026-05-06

Post by julianramirez on Codesys Trend - setting Y axis minimum and maximum as variables - error CODESYS Forge talk (Post)
Hello Hannibal, I am using real vars and it works, however, if I update those vars in real time it doesnt quite change it on y axis, do you think it is because it is not an integer?
Last updated: 2026-05-21

How to reset forgotten User Management / Administrator password on CODESYS Control Win V3 (V3.5 SP22 Patch 2)? CODESYS Forge talk (Thread)
How to reset forgotten User Management / Administrator password on CODESYS Control Win V3 (V3.5 SP22 Patch 2)?
Last updated: 2026-08-25

Post by eschwellinger on How to reset forgotten User Management / Administrator password on CODESYS Control Win V3 (V3.5 SP22 Patch 2)? CODESYS Forge talk (Post)
since 3.5.20.10 version you should find it here: C:\Windows\system32\config\systemprofile\AppData\Roaming\CODESYS\xxxxxxxx (64Bit) C:\Windows\SysWOW64\config\systemprofile\AppData\Roaming\CODESYS\xxxxxxxx (32Bit) you need to have admin rights.
Last updated: 2026-08-26

Post by reinier-geers on Read own network device name CODESYS Forge talk (Post)
Hi. When i scan for devices on the network i get names of the devices. Is there a command to get device name in my programm ? i found : DED.GetDeviceNameString( DED.GetRoot() ); but then i get his name in the programm. not his name in the network.
Last updated: 2026-09-17

Post by reinier-geers on Read a webclient value CODESYS Forge talk (Post)
Hi i get a json value from an energy site. Every hour a value. to cut the answer in an array so i can read every hour it try FindWString . find Marketprice. But it turns in every array on a diverent position. Why ?
Last updated: 2026-10-08

Post by mondinmr on COL.IMap2 and HashTableFactory cause frequent Access Violation CODESYS Forge talk (Post)
Good morning, I’ve been using the Collection library for a long time, mostly with Stack, LinkedList, and List. From your examples I was able to manage the different factories, even for custom elements. Now I need a hashtable, but with this object I’m running into a lot of random access violations. If I append something inside FB_Init after constructing the hashtable, it crashes, even though the list was already created. If I only create the hashtable in FB_Init and append afterwards, it usually works. I don’t understand the meaning of the dispose call in this code: pSlave := ADR(slave); uSlave := TO_ULINT(pSlave); iKey := fKey.Create(uSlave); IF hash.CountKeys() = 0 THEN Service.logger.appendLog('Filling hashtable', 'HashManager', AdvLogType.AdvDebugMsg); ok := FALSE; ELSE eError := hash.ContainsKey(iKey, xResult => ok); END_IF IF NOT ok THEN pI := __NEW(UINT); iVal := fKey.Create(TO_ULINT(pI)); Service.logger.appendLog(CONCAT('New slave', TO_STRING(uSlave)), 'HashManager', AdvLogType.AdvDebugMsg); hash.AddKeyValuePair(iKey, iVal); appendNewSlave := pI; ELSE eError := hash.GetElementByKey(iKey, itfValue => iElem); xResult := __QUERYINTERFACE(iKey, itfIInstance); IF xResult THEN itfIInstance.Dispose(); END_IF IF eError <> COL.COLLECTION_ERROR.NO_ERROR THEN Service.logger.appendLog(CONCAT('ERROR ', TO_STRING(eError)), 'HashManager', AdvLogType.AdvCriticalMsg); appendNewSlave := nullptr; RETURN; END_IF __QUERYINTERFACE(iElem, iVal); {warning disable C0033} pI := TO___UXINT(iVal.UlintValue); {warning restore C0033} appendNewSlave := pI; END_IF Without the dispose call, every second cold reset crashes immediately when I try to access iVal, even if eError doesn’t report any error. With the dispose call, the cold reset issue disappears, but I get other problems: a) If I start the runtime using systemctl start codesyscontrol, it crashes at IF hash.CountKeys() = 0 THEN b) If I delete the files in PlcLogic and download again, it works and survives multiple cold resets. But as soon as I run systemctl restart codesyscontrol, everything gets corrupted again and it starts crashing at that point. FUNCTION_BLOCK SlaveMapCounter VAR hash : COL.IMap2; eError : COL.COLLECTION_ERROR; END_VAR In its FB_Init I create it: METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR hF : COL.HashTableFactory; END_VAR hash := hF.Create(256); In another FB I instantiate it statically: FUNCTION_BLOCK ABSTRACT AbstractServoEthercatController EXTENDS AbstractServoController VAR_STAT hashSlaves : SlaveMapCounter; END_VAR VAR field : REFERENCE TO ADVAbstractFieldUnitEthercatCia402; initCnt : REFERENCE TO UINT; END_VAR The append method is the one shown above, and I call it after the runtime has started. The accesses are performed by a single task, and in any case I’m working on an isolated single core. I’ve tried everything, moving the create, the instances, and all the rest several times, but nothing seems to work. I’d like to point out that these FBs are part of our own library, which is used in many applications.
Last updated: 2025-09-11

Post by dhumphries on install codesys runtime on linux CODESYS Forge talk (Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools → Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04

Post by appling on License status of Linux 64Bit runtime via CLI CODESYS Forge talk (Post)
Hi, I have a Linux 64Bit system with a Codesys application running on it. It stops after 2hours and a few minutes, which makes me think something is wrong with the installed license. (in my last timing it stopped after 2h4min, on the codesys website it is stated that runtimes without a license stop after 2h) I installed the license via a USB license dongle that I activated on my workstation with the Codesys IDE a while ago. Now the system is shipped at not accessible physically, only remotely via SSH. So is there a way to check the status of the License of the Codesys runtime when it is running on the system? Running the codesyscontrol script with "status" just tells me that it is running, but does not provide any license information. Best regards
Last updated: 2023-12-04

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
Hi there, I'm running the Codesys runtime on Windows 64 and I need to know if it is on "Running" or "Stopped" state just after a system crash. The following commands works perfectly well to (re)start it... net stop “CODESYS Control Win V3 - x64" net start “CODESYS Control Win V3 - x64" ...however I'm unable to determine when it is required to be call; I mean, by checking the System Tray icon, it is possible to know if it is on "Stopped" state, but I wanted to run a .BAT command to retrieve it. How can we do that?
Last updated: 2024-07-02

Post by shrikantp007 on help to get codesys understand CODESYS Forge talk (Post)
Hello , I need some help on how to start with , 1) how to get test license to test codesys , 2) how to take a configuration backup or running process back and post file on fourm so people can understand and deploy same file and get idea what is missing or configure wrong 3) where i can get pdf for codesys admin or programmer 4) what is hardware recommand ,i am running on windows guest on kvm server .is it ok ? 5) i am trying to get ardunio porject working ,using ardunio board as a modbus slave but its not working some how https://forge.codesys.com/forge/talk/Engineering/thread/bf832569b8/ Thanks in advance . shrikant pune -india
Last updated: 2024-07-22

Post by mubeta on Reset problem with CMZ SD/SVM drive CODESYS Forge talk (Post)
In a recent project with SoftMotion 4.15.0.0, where I integrated two SD drives from CMZ (from catalogue EDS and not imported), on CANopen bus, I found that the SoftMotion MC_Reset function does not reset the drive faults. Even if the drive is in fault, either on the device or on the drive at the CoDeSys level, the function does not reset, instead reporting the error code: no error to reset. Finally, I had to connect the reset bit of the ControlWord directly to a tag in my program. Something I never had to do on other drives: Lexium, etc. all reset simply with MC_Reset.
Last updated: 2024-07-24

Post by peterkcontrols on TargetVisu started in windowed or not full screen CODESYS Forge talk (Post)
Hello, I am using Codesys on an industrial pc with a single monitor. I would also like to have a separate vision software running on the PC and would like to display it half screen. When I run the soft PLC the my visualization screen appears full screen, I would like to be able to set the size of the visualization screen so I can display other software on the monitor. Is it possible to set the width/height of the targetVisu? Anyone try something similar? I would like to avoid having to put it on a Virtual Machine. Thank you
Last updated: 2025-02-26

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Hi, I want to use two OneWireMaster on a Raspberry Pi5. I'm running Codesys Control for Raspberry Pi 64SL V 4.15.0.0. Under Linux I've configured two GPIOs for 1w bus usage on GPIO4 and GPIO27. Under Linux both masters seem to work fine and I can readout both sensors connected to both GPIOs. The two masters are 'w1_bus_master1' and 'w1_bus_master2'. In Codesys I've configured to OneWireMasters with the corresponding file paths. But in Codesys the 2nd onewiremaster "w1_bus_master2" doesn't work. Status is showing "OnewireMaster : Not running" What am I doing wrong? Does Codesys on Raspberry support multiple OneWireMasters? Any help is appreciated.
Last updated: 2025-06-10

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Hi, I want to use two OneWireMaster on a Raspberry Pi5. I'm running Codesys Control for Raspberry Pi 64SL V 4.15.0.0. Under Linux I've configured two GPIOs for 1w bus usage on GPIO4 and GPIO27. Under Linux both masters seem to work fine and I can readout both sensors connected to both GPIOs. The two masters are 'w1_bus_master1' and 'w1_bus_master2'. In Codesys I've configured to OneWireMasters with the corresponding file paths. But in Codesys the 2nd onewiremaster "w1_bus_master2" doesn't work. Status is showing "OnewireMaster : Not running" What am I doing wrong? Does Codesys on Raspberry support multiple OneWireMasters? Any help is appreciated.
Last updated: 2025-06-10

Post by monteta on Automation without UI CODESYS Forge talk (Post)
Hello all, there is my problem. i have a project on a PC A who work properly, I aim to take this project and place it on a Pc B with a blank Codesys installed. All seemd to work, the project is created on the PC B, i create my with with online.create_online_application(project.project.active_application) recover my onlineDevice and try onlinedevice.connect() so that i can use create_live_user_management() but then a problem occure on my connect() saying gateway not configured properly. I have setted my set_credentials_for_initial_user(). when i use the Ui, there is absolutely no problem. an other question, is it possible to use the Start and Stop PLC of codesys Control Systray directly in my python script? So that if it detect that it's stopped, then he automatically start it?
Last updated: 2025-09-25

Post by valenting on Runtime not working on raspberry pi Bullseye CODESYS Forge talk (Post)
Hello I have a problem with Codesys on Raspberry pi with Bullseye The device is not recognized as a Raspberry pi, as I get this error : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) I'm running Codesys on a compute module 4S with Raspbian GNU/Linux 11 (bullseye), my kernel version is Linux 5.10.90-v7l+ Codesys version is the latest, released last week (4.11.0.0, CODESYS Control V3.5.19.61 for ARM-32Bit - build Feb 22 2024) I know it works on the same device if I use Raspbian 10 (Buster) with Linux 5.4.81-v7l+ kernel, but for some other reasons I have to use Bullseye. What can I do ?