Post by blitz on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
So in my case the solution was that I had both smooth path and round path in the code. Both blocks had their own buffer and seemed completely separate but still triggering Execute on both caused the mentioned problems. When I blocked Execute the problems disappeared.
Last updated: 2026-01-11
Post by peder on Parker Compax3 controlled by Schneider LMC 201
CODESYS Forge
talk
(Post)
Hi Bruno Thank you for your answer. So this is not possible. Do you know some thing else that could replace the PAC320?
Last updated: 2026-01-13
Post by reinier-geers on Data to server
CODESYS Forge
talk
(Post)
HI, i want to copy data to a server of a costumor. Whats the easy way ? contoller is V20p5 but also 2 are V9.2
Last updated: 2025-11-11
Post by clockben on Python script to add libraries to project
CODESYS Forge
talk
(Post)
Hello, I have the same issue — some libraries aren’t resolved. When I load the libraries manually and delete them, reloading with the script works fine afterward. Have you found a solution since then? Many thanks in advance
Last updated: 2025-11-11
Post by grepoo on DataSource CodesysApp V3
CODESYS Forge
talk
(Post)
Hi, trying to create a datasource in appV3 but it returns error code 259 (not nearer specified) everytime, no matter the device i am using. Any idea of what it might signify ?
Last updated: 2025-11-19
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
I did some work around by adding IN switch on top of OUT bulb picture(SwitchImage) and setting IN switch button to invisible but this is not quite elegant. How to combine it to one visu element?
Last updated: 2025-11-20
Post by ggaida on runtime dynamic modbus devices
CODESYS Forge
talk
(Post)
Kurtk, I am working through a very similar scenario. I am curious if you have had any success since your post in implementing dynamic modbus configurations? Thx!
Last updated: 2025-11-20
Post by ggaida on runtime dynamic modbus devices
CODESYS Forge
talk
(Post)
Kurtk, I am working through a very similar scenario. I am curious if you have had any success since your post in implementing dynamic modbus configurations? Thx!
Last updated: 2025-11-20
Post by bertram on Installation IOT Libraries kann nicht installiert werden
CODESYS Forge
talk
(Post)
Habe mittlerweile festgestellt das es nicht am package liegt, auch andere sinddavon betroffen. Ich denke das Problem wird durch windows verursacht, aber was kann dazu führen ??
Last updated: 2025-11-25
Post by mr-ege on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
I have tried these steps, but it still does not work. What should I do? I'm stuck on this error. I cannot design the HMI, I need help.
Last updated: 2025-11-27
Post by eld-t on Change Git local repository folder name
CODESYS Forge
talk
(Post)
Hi, how do you change the Git local repository folder name? It is called "project" by default, so we would like to rename it to something more descriptive especially for the remote repo's sake. Thanks!
Last updated: 2025-12-10
Post by amira on Visu 4.9.1 auto-logon/login
CODESYS Forge
talk
(Post)
Hello Julian, could you please check in Chrome Password Manager Settings if the option "Offer to save passwords" is set? With this option selected, a pop-up message will then show up asking whether or not to save the password. Choose OK. Hope this helps.
Last updated: 2026-01-14
Post by reinier-geers on Error ambigiusname
CODESYS Forge
talk
(Post)
In visu i have a Led. I only changed the output. Then i get Ambigius use of name Tpara. But it doesnt show where. See screen shot
Last updated: 2026-01-20
Post by hprog on SP19 Runtime Zugriff auf lokales Dateisystem
CODESYS Forge
talk
(Post)
ich hab da noch eine Frage zu diesem Thema, wenn in [SysFile] PlaceholderFilePath.1=/tmp, $TMP$ z.B /home/pi angegeben wird gilt das dann auch für die darunterliegenden Unterverzeichnisse z.B. /home/pi/MSG oder müssen diese immer separat angegeben werden? und was bedeutet das , $TMP$
Last updated: 2026-01-22
The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
CODESYS Forge
talk
(Thread)
The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
Last updated: 2026-01-27
Post by fleaplc on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Did you check the communication with a sniffer ? (ex. Wireshark) to check if the holding get to zero by a wrong writing (client initialization?) o something else?
Last updated: 2026-01-27
Post by chaoschaos on Visualisation generates "Unresolved reference"
CODESYS Forge
talk
(Post)
For the DynamicText error i have finally found a solution. You have to delete some libraries from your project. For me it was the WagoSysIcon library which wanted to reference dynamictexts even though i didn't have any in my project.
Last updated: 2026-02-02
Post by gatto on Two licenses have to be installed forgot to enable one license
CODESYS Forge
talk
(Post)
Hi. What type of PLC do you have? What activation method do you use? What license ticket did you purchase and want to activate? Can you describe the process you followed step by step?
Last updated: 2026-02-02
Post by arpat on Error, visualisation property handling, VISU_USEPROPERTYINFO
CODESYS Forge
talk
(Post)
For me going to Project -> Project Settings -> Visualisation -> check "Visible" and then check both "Activate property handling ..." and "Activate implicit checks ..." solved the problem.
Last updated: 2026-02-03
Post by jslarbaletier on Unable to compare projects containing alarm manager 4.5.0.0
CODESYS Forge
talk
(Post)
Hi! I had the same issue and finally found a solution. Alarm Configuration was located in a “Visualisations” folder. I moved Alarm Configuration directly under “Application”, and the issue was resolved.
Last updated: 2026-02-05
Seeking a Code-Based Solution for EtherCAT Slave Dropout or Master Errors in Production (Beyond Software Hot Reset)
CODESYS Forge
talk
(Thread)
Seeking a Code-Based Solution for EtherCAT Slave Dropout or Master Errors in Production (Beyond Software Hot Reset)
Last updated: 1 day ago
Post by patrik on Wish: CODESYSControl.cfg - again
CODESYS Forge
talk
(Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21
Post by steven-schalm on Github Actions CI/CD tasks - development topic
CODESYS Forge
talk
(Post)
hello kevinrn, I've been looking for a solution to the CI/CD issue for a long time. Briefly about me... I am 32 and software architect for Codesys V3 and fullstack dev for web (VueJS, NestJS) in a small company in Erfurt (Germany). https://www.rex-at.de/. Through my web part, we already have CI/CD running well via GitLab (YAML-based configuration file (.gitlab-ci.yml), which defines which pipelines and jobs are executed when certain events occur) with everything you know. Stages for npm packages - prepare (GitVersion, npm install or whatever) - build (vite, tsc or whatever) - testing (vitest, jest or whatever) - deploy (npm packages) And similar for monorepo's or backend services (in NestJS) as DockerImages. For Codesys we have been building an OOP framework for years (~50 libraries now), which is currently managed via SVN and a specially written Svn-Watcher (in Python) gets commits and runs and builds everything together and deploys it to an FTP server and network drive. Why do we still have SVN? Because we are unfortunately still tied to the safety integration of Codesys and can therefore only go to SP15 at most with our controller/Eckelmann. But soon there will be an update and there will be no more obstacles to using Git. Hence my questions: 1. the basic idea is to run a local Windows Runner on some machine? 2. install Codesys on the machine where the runner is running? 3. powershell & python scripts are then used to execute builds (compile, build, sign libraries) & deploys? 4. can the Github action also be used in GitLab? ChatGPT has already told me that it's not the same, but it doesn't hurt to ask. Do you have any ideas on this? Greetings :D
Last updated: 2024-08-20
Post by fmon on Modbus : dis- / re-connect cable: modbus does not re-start
CODESYS Forge
talk
(Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED" It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus reconnection. What is different at the first connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-14
Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port
CODESYS Forge
talk
(Post)
I have an IPC with 2 ethernet ports and 1 Wi-Fi. I'm using ModbusTCP with the ethernet port named "enp2s0" connected to my remote I/O. This works fine when testing with Python and also works with CODESYS, but CODESYS is only able to scan for the Linux SoftPLC when I turn off the "enp2s0" interface. In other words, I can't get online with the IDE if I want my ModbusTCP comms to run with CODESYS. I'm using a Linux SoftPLC that has the following entry in CODESYSControl.cfg, hoping that this will allow me to connect with "enp1s0" or "wlp3s0", and leave "enp2s0" for field comms, but this seems to only make the source IP of the ModbusTCP comms to be bound to "enp2s0". That last point is the case only if I don't restart the service, but if I do restart the service after changing the config file, the source IP for the ModbusTCP comms then becomes the one for "enp1s0", which is very confusing to me: [SysSocket] Adapter.0.Name="enp2s0" Adapter.0.EnableSetIpAndMask=1 On the device list, I only have "enp2s0" given as the ethernet device that has the ModbusTCP master & slave beneath it, shown in Screenshot 1. On the IPC, I can ping the ModbusTCP client (remote I/O) from "enp2s0", and I've attached a Wireshark capture of running ModbusTCP from the CODESYS runtime as Screenshot 2, 3 & 4 (again, I can't get online when this is running, I have to turn off "enp2s0" to connect even when it's idle and I don't have an active TCP session with my Python tests). Like I explained above, the source IP is "enp1s0", even though the ethernet device on the project is "enp2s0". I was lucky to catch the red message that showed the source IP that makes sense to me (the one for "enp2s0"), but for some reason that connection was reset and I never saw that packet again. I've also tried this with Auto-reconnect both enabled & disabled, for the ModbusTCP Master device. I also have to turn off "enp1s0" and then turn it on, just so that I can have the ModbusTCP comms running from "enp2s0" (which is not intuitive in any way to me, I'd love some help understanding that phenomenon as well) in the weird manner that I've described above. I would be very appreciative if someone can help me figure out this pickle. I'd love to just connect to CODESYS through my Wi-Fi interface and leave my ethernet ports for field comms.
Last updated: 2024-08-01
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.