Post by wchin on Passing EtheNetIP adapter device into a Function Block to access it's IO CODESYS Forge talk (Post)
We are creating helper function blocks for our VFD(EtherNetIP). How should I set it up so that I can pass the device into and out of the Function Block so that ideally I can access the IO of the device by devicename.channelname. So something like for example we have a VFD with a start bit that is in the ControlWord channel and a SetVelocity that is a channel. And we want to create a Function Block called StartVFD. So I declare something like: FUNCTION_BLOCK StartVFD VAR_IN_OUT device: ioDrvEthernetIP.RemoteAdapter; END_VAR VAR_INPUT velocity : REAL; So in the code it would look something like device.SetVelocity := velocity; device.ControlWord.6 := True; We have a pretty basic eds file for our VFD and can update it if necessary. Thanks in advance.
Last updated: 2025-10-28

Post by wchin on Passing EtheNetIP adapter device into a Function Block to access it's IO CODESYS Forge talk (Post)
We are creating helper function blocks for our VFD(EtherNetIP). How should I set it up so that I can pass the device into and out of the Function Block so that ideally I can access the IO of the device by devicename.channelname. So something like for example we have a VFD with a start bit that is in the ControlWord channel and a SetVelocity that is a channel. And we want to create a Function Block called StartVFD. So I declare something like: FUNCTION_BLOCK StartVFD VAR_IN_OUT device: ioDrvEthernetIP.RemoteAdapter; END_VAR VAR_INPUT velocity : REAL; So in the code it would look something like device.SetVelocity := velocity; device.ControlWord.6 := True; We have a pretty basic eds file for our VFD and can update it if necessary. Thanks in advance.
Last updated: 2025-10-28

Post by wchin on Passing EtheNetIP adapter device into a Function Block to access it's IO CODESYS Forge talk (Post)
We are creating helper function blocks for our VFD(EtherNetIP). How should I set it up so that I can pass the device into and out of the Function Block so that ideally I can access the IO of the device by devicename.channelname. So something like for example we have a VFD with a start bit that is in the ControlWord channel and a SetVelocity that is a channel. And we want to create a Function Block called StartVFD. So I declare something like: FUNCTION_BLOCK StartVFD VAR_IN_OUT device: ioDrvEthernetIP.RemoteAdapter; END_VAR VAR_INPUT velocity : REAL; So in the code it would look something like device.SetVelocity := velocity; device.ControlWord.6 := True; We have a pretty basic eds file for our VFD and can update it if necessary. Thanks in advance.
Last updated: 2025-10-28

Post by miltos on licensing question CODESYS Forge talk (Post)
Greetings to all, I'm working on a webvisu project on control win V3 x64 runtime, and have purchased 3 licenses for my application. -Codesys Control Standard M -Codesys Visualization L -Codesys Communication M I have them installed on a Codesys usb dongle When I try to download the program, a login error window appears with the message "No valid license found for the webvisualization". The control win v3 communicates with 3 plc, and have enabled communication over codesys V3 communication by adding one datasource for every plc in the datamanager. If I remove the data manager from the project, the rest of the visualisation can be downloaded normally. Do I need to purchase another License and which one? Please find attached the software metrics and the error screen.
Last updated: 2025-10-31

Post by davidbo on How to stop dhcpcd and use SysSockSetIpAddressAndNetMask to set address? CODESYS Forge talk (Post)
The reason for why CODESYS halts was a CODESYS watchdog exception. 'sudo ip' takes a long time.
Last updated: 2025-11-04

Post by eschwellinger on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
..the missing part is which Softmotion version is installed. Check it in the CODESYS Installer and update it to latest version.
Last updated: 2025-11-10

Post by adam on Get/Set I/O Address Mapping of DeviceObjects in python Script CODESYS Forge talk (Post)
Found out.Its script engine bug . Update to script engine version 4.2.0.0. and problem solved
Last updated: 2025-11-17

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Thank you for the information and support - I need to think this through again.
Last updated: 2025-11-18

Post by timvh on Using a raspberry pi and NVLs to log variables outside of Codesys CODESYS Forge talk (Post)
Yes, this will work.
Last updated: 2025-11-21

Post by msirotkin on EtherCAT status errors CODESYS Forge talk (Post)
Hello, I'm trying to understand the reason for the many errors on the EtherCAT master status page. If we set the cycletime to 1ms we see a lot of rxerrors and lostframes, but the send and recive times are quite good (see attachement). And the status of the EtherCAT bus is good (no other errors, all is green, slave has no errors) But when we set 2ms cycletime the lostframe errors are gone, but periodically increses rxerror counter (see attachement). The questions is, what do these errors actually mean and what we can do to get gid of them? Linux RT, imx8, Codesys runtime for ARM 3.5.21.10, Ethercat 4.10 Thanks
Last updated: 2025-11-25

Post by imdatatas on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
Unfortunately, the "C0138: No matching 'FB_Init" method found" error is a nightmare for CODESYS V3.5 SP21. I'm not sure if anything has been done about this or if anything will be fixed. I've encountered the same issue many times, and it was only resolved by completely uninstalling SP21, deleting all related files and folders from my computer, and then installing SP19. So, I've given up on using SP21 and switched back to SP19patch7. Here are some previous posts regarding the "C0138: No matching 'FB_Init" on SP21 of Codesys. https://forge.codesys.com/forge/talk/Visualization/thread/0763d6ca8e/ https://forge.codesys.com/forge/talk/Motion/thread/9074005bf4/
Last updated: 2025-11-28

Post by tali on Configuration of disabled/deactivated visu elements CODESYS Forge talk (Post)
would be great to have such fucntionality. Sometimes it is not clear for user which elemetns are blocked and which are not - the greyed out eleemtns are not so different for low resolution / low quality screeens. What I have in my mind as well is to have a possibility to detect the visu Element clicked on and get its Access Rights. If it is blocked/deactivated, the dialog can be rised with INFO 'please login first with proper rights'. It is possible now to have a Mose event Handler ( Examples -> EventHandler) and rise the dialog out of ST (Exapmpals -> ST Dialogs). I am struggling still with getting the separate Visu Element under the mouse and its structure info
Last updated: 2025-12-05

Post by alexmserra on CAN and CANopen on Raspberry PI - steps or tutorial? CODESYS Forge talk (Post)
Good afternoon, how does the CANbus configuration look in Codesys, for example, network 0?
Last updated: 2025-12-09

Post by eschwellinger on Scara3 kinematic robot error CODESYS Forge talk (Post)
Please check the jitter in the online taskmonitoring. cylce time of the motion task and jitter in case of the error.
Last updated: 2025-12-29

Post by blitz on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
@bertus try to test using only SMC_SmoothMerge and SMC_SmoothPath separately. Block setting bExecute on both of this FBs.
Last updated: 2026-01-11

Post by karsonsv on CODESYS HMI and 2 monitors CODESYS Forge talk (Post)
Thank you. The question has been resolved. C:\Users*User\AppData\Roaming\CODESYS\CODESYSHMIWinV3*code project Need chanje targetvisuextern.cfg
Last updated: 2026-01-13

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
yes it is and it need to be realtime capable with a preempt_rt patched kernel.
Last updated: 2025-11-17

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
yes it is and it need to realtime capable with a preempt_rt patched kernel.
Last updated: 2025-11-17

Post by ducng on SMC_ERROR.SMC_AXIS_NOT_READY_FOR_MOTION when using Drive Virtual CODESYS Forge talk (Post)
I'm using drive virtual and cannot run the motion command. Please help.
Last updated: 2025-11-26

Post by ranadheer on Assistance for MQTT configure with external broker (Mosquitto) CODESYS Forge talk (Post)
Hi everyone Am trying to make establish MQTT connection , where am using IIOT example for this as a demo mode. where i had given IP-address of of local Linux application as a 172.31.239.67 and port number as 1883 in the PLC_PRG itself, and preparing the publish message by manually as " this is from published message", and this should receive at the subscriber side. Aim: To make communicate external publisher to the CODESYS by using MQTT protocol. By any chance having reference documents about this implementation please share here. and suggest the process to make it possible. I had uploaded reference project file after updating address in th PLG_PRG, kindly assist to configure with the broker
Last updated: 2025-12-03

Post by eschwellinger on Soft Container License issue with ARM64 Linux CODESYS Forge talk (Post)
van you execute cmu -x to see if dongle and softcontainer are available.
Last updated: 2025-12-08

Post by julianramirez on Visu 4.9.1 auto-logon/login CODESYS Forge talk (Post)
Hello everyone, I have been trying to test the auto-login feature that is advertised on the Release Notes since Visu 4.8: *Version: 4.8.0.0 Besides some bug fixes and improvements this version contains the following new functionality: Alarmmanagement: Possibility to raise alarms programmatically Use real time clock of IEC context Automatic login for WebVisu using Chrome "Sign in automatically"* I am using a personalized login Visualization, the User Management works, however, when ticking the checkbox that keeps the credentials stored, after I reload the page I still see that the user and password details are not filled in. I tried with the default Login Visu (Blue one), and still see the same behavior - VisuUserManagement.VUM_LoginVisualization - I've tried with Chrome and Edge. Thanks for your help
Last updated: 2026-01-12

Post by mascara on JOG continues in WCS ( SMC_GroupJog2 ) CODESYS Forge talk (Post)
I'm using the SMC_GroupJog2 block from the SM3_Robotics library for manual movement of an AxisGroup in WCS coordinates. The observed behavior is: When pressing X+, the X-axis starts moving correctly. If I press Y+ during the movement, the block interrupts the current movement and starts a new movement in X and Y. If I release any button, all axes stop, even if another button is still pressed. Example: Pressing X+ β†’ X moves Pressing X+ and Y+ β†’ X stops momentarily and starts XY movement Releasing X+ while holding Y+ β†’ all axes stop The expected behavior would be: to allow simultaneous continuous movement on multiple axes to not interrupt movement when another axis is added or removed. Is there a correct configuration of SMC_GroupJog2 to achieve this behavior, or is there another block more suitable for continuous manual jog in AxisGroup (WCS)?
Last updated: 2026-03-11

Post by vietnam-coder on Ethernet/IP EDS file CODESYS Forge talk (Post)
excuse me , can you help me to raise up to 255 input and output please ,
Last updated: 2026-03-24

Post by baott569 on Limitation on OPC UA Variable 100+ variables on raspberry pi CODESYS Forge talk (Post)
Sorry, not trying to spam, My internet lagged and I thought the comment wasn’t submitted
Last updated: 2026-01-22