Post by corriibme on JSON Utilities and SetArray
CODESYS Forge
talk
(Post)
Hello @florian, Could you please help with how to set an array value? I've been trying to use the with the setKeyWithArray method which creates the key with an empty array value. But I have been unable to set items in this array? objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindexx); //iValue: array[0..n] of int; Best regards
Last updated: 2024-05-11
Post by miodusy on CODESYS Control Standard S and Beaglebone
CODESYS Forge
talk
(Post)
Hi, CODESYS Control Standard S + CODESYS Visualization L, CODESYS Control for Beaglebone 4.11.0.0, CODESYS V3.5 SP20 + (64-bit) I have problem that license manager say that this device is not supported when i try active whole license. When I select only runtime and communication it is go next step, but then I no have license on in Visualistion section, all of rest of software metric licese is ok(IO, Istances of com et, code size etc.). Thanks!
Last updated: 2024-05-11
How to define CONDITIONAL PRAGMA that effects all ST-POU in project.
CODESYS Forge
talk
(Thread)
How to define CONDITIONAL PRAGMA that effects all ST-POU in project.
Last updated: 2024-05-12
Post by k2saki on How to define CONDITIONAL PRAGMA that effects all ST-POU in project.
CODESYS Forge
talk
(Post)
I'd like to use same code/project in different devices. (RPi, PLC) I change some lines in some POU before compiling. (array size, file path, etc ) My question is How to define pragma that effects all ST-POU in project. Is it possible ? I've read this. https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_pragma_conditional/
Last updated: 2024-05-12
Post by corriibme on Setting array values with JSON Utilities SL
CODESYS Forge
talk
(Post)
I have been trying to set an array value to a JSON structure of this form: {"key": [1,2,3,4]} While I have been able to create the key and set its value to an empty array, I've not had any luck in putting any value in that array. objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindex); iValue2: ARRAY[0..3] OF INT:= [1,2,3,4]; The two lines of code above produce {"key6": []} . The second line essentially has no effect.
Last updated: 2024-05-12
Post by dalfaro21 on Softmotion not working with simulation mode
CODESYS Forge
talk
(Post)
I have a KEB combivis studio software running codesys and I want to make some moves but softmotion is not working on my laptop I hope you can help me!
Last updated: 2024-05-12
Post by totorovic on Softmotion not working with simulation mode
CODESYS Forge
talk
(Post)
Good morning, I think that the mode Simulation does not support the Softmotion functionnality because it runs the CODESYS process with normal priority wich is not a good thing for real-time behavior. If you want to test your PLC project, please use a Codesys Control Softmotion (and your computer must have the Ethercat driver installed) or much easier, download your code into the C6 Smart. BR
Last updated: 2024-05-13
Softmotion not working with simulation mode
CODESYS Forge
talk
(Thread)
Softmotion not working with simulation mode
Last updated: 2024-05-13
Post by wildcard on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13
Post by rajesh008 on i can't declear the address in GVL - codesys SP19 Patch5
CODESYS Forge
talk
(Post)
The “_AB AT %IW0:word; ” if i called the value then im getting this error. like below "the declartion of the variable with an address assignment cannot be used in a PRG or GVL with the attribute 'subsequent'" This is happening when the GVL is selected in Redundancy Configuration. if i un-select the address declaration is working fine
Last updated: 2024-05-13
i can't declear the address in GVL - codesys SP19 Patch5
CODESYS Forge
talk
(Thread)
i can't declear the address in GVL - codesys SP19 Patch5
Last updated: 2024-05-13
Post by kuegerls on CSV Utility SL
CODESYS Forge
talk
(Post)
Hello, I want to read a CSV file using the CSV Utility SL library, but I encounter an 'invalid_handle' error during initialization. What could be the cause? For my test program see the screenshot. I have purchased a license, and it is also installed on my PLC. Thank you in advance. Best regards, Stefan.
Last updated: 2024-05-13
Post by walkercope on Ethercat bus on Beckhoff CX with Codesys for Linux
CODESYS Forge
talk
(Post)
Has anyone figured out a way to use the ethercat bus on a beckhoff CX using codesys running on linux? Using ethercat on the native NICs works fine but I get a "packet could not be sent" error when trying to scan the ethercat bus device. Errors and hardware in attached image.
Last updated: 2024-05-13
Post by eschwellinger on Ethercat bus on Beckhoff CX with Codesys for Linux
CODESYS Forge
talk
(Post)
yes I think you need to build the kernel drivers for the CCAT driver for the backplane ETC networkcard https://github.com/Beckhoff/CCAT/
Last updated: 2024-05-13
Ethercat bus on Beckhoff CX with Codesys for Linux
CODESYS Forge
talk
(Thread)
Ethercat bus on Beckhoff CX with Codesys for Linux
Last updated: 2024-05-13
Persistence Manager Backup
CODESYS Forge
talk
(Thread)
Persistence Manager Backup
Last updated: 2024-05-14
Post by wiresplus on How to display the application name on a visualization (V3.5.16)
CODESYS Forge
talk
(Post)
Hello! I would like to display the project name on the HMI The project name contains the version number That way, a tech knows which version is loaded on the PLC. Is the a standard way to display this, or do I have to hard-code into the HMI (not ideal)?
Last updated: 2024-05-13
Post by yannick on Alarm Configuration Notification Action
CODESYS Forge
talk
(Post)
Hello, I'm trying to configure an alarm variable that changes to True when an error is activated. Unfortunately, the variable is not changing to True. I'm using Codesys V3.5 SP19 Patch7 + Raspi Pi 5. Thanks.
Last updated: 2024-05-13
Post by matthew on New Ladder Diagram conversion does not work due to missing features
CODESYS Forge
talk
(Post)
Hi @eschwellinger Just wondering if there is any update when the Expression or part of it has no effect will be fixed? Also have the ability to open an FB when online and offline. It would also be great to be able to view the ST code block when online.
Last updated: 2024-05-14
Post by matthew on Persistence Manager Backup
CODESYS Forge
talk
(Post)
Hi @eschwellinger yes I have been using xDoubleStorage It happened again and I checked and the files were still there with there contents, restarting codesys or rebooting would not even reload them. Doing a download and then starting the PLC loaded them and began working again. Some sort of mismatch error or something?
Last updated: 2024-05-14
Post by totorovic on How to display the application name on a visualization (V3.5.16)
CODESYS Forge
talk
(Post)
You could use the function AppGetApplicationInfo from CmpApp library. https://content.helpme-codesys.com/en/libs/CmpApp/Current/AppGetApplicationInfo.html
Last updated: 2024-05-14
Post by eurowolf on SoftMotionLight Lizenz nach Programmupdate weg
CODESYS Forge
talk
(Post)
Hallo, auf einer Sabo MKS855.20 habe ich die SoftMotionLight-Lizenz installiert. Zur Programmierung nutze ich V3.5 SP16.0. Die im Projekt verwendete SML 4.7.0.0, SML_Drive_CAN_GenericDSP42 3.5.7.0, CANopen_Manager_Softmotion 3.5.16.0. In der Regel habe ich keine Probleme mit der SoftMotionLight, nur bei dieser Anlage ist es mir jetzt zum Zweiten mal passiert, das ich ein Programmupdate einspiele und die SML in den Demo-Modus wechselt. Die Lizenz ist doch auf der SPS gespeichert, warum wird dann behauptet, dass die SML im Demo-Modus arbeitet. Da ich z. Zt. beim Kunden vor Ort bin und dieser sich im Ausland befindet, benötige ich kurzfristig eine Lösung. Auf E-Mails bekomme ich leider keine Rückmeldung.
Last updated: 2024-05-14