Post by manuknecht on FileDialog - OnDialogClosed not called anymore CODESYS Forge talk (Post)
I had similar issues with the OnDialogClosed not being called. I realized that this behaviour is resolved, when the according visualization object on which the input configuration is set is moved to the foreground. Somehow, the object has to be one of the lowest elements in the Element List (i.e. in the foreground) for it to work.
Last updated: 2025-04-25

Post by atone on Change IO-Link Device Interface connected to a Profinet-Slave at Runtime CODESYS Forge talk (Post)
OK, I figured out that I can simply define all the sensors as 16 bytes IN/OUT, even if they are not all used. EDIT: The negative effect is that each bit is taken into account as an I/O for the license, even if not used.
Last updated: 2025-04-28

Post by andrej on Creating, using an external Function. CODESYS Forge talk (Post)
One step closer Hello finally the SoftPlc starts to load the dll on start up, however it is not successfull. I create a new minimal example Lib_XMATH.dll. Could please give me a hint, why the dll is not succesully loaded yet. Inputs would be highly appreciated. Many thanks.
Last updated: 2025-04-30

Post by ellocco on Kann mich nicht am Gerät anmelden CODESYS Forge talk (Post)
Nachdem ich einige Zeit unbehelligt arbeiten konnte, bin ich wieder ausgesperrt, Deinstallieren und Neuinstallation der Nachfolgeversion (SP21) hat nichts gebracht und der Trick, der unter SP18 funktioniert ist mittlerweile verbaut (wie bereits geschrieben). Gibt es evtl. in der Registry einen Ort, an dem ich etwas löschen muss / modifizieren kann?
Last updated: 2025-05-09

Post by pafarrell on EtherCAT quick start for advanced programmers CODESYS Forge talk (Post)
It would be great if there was a thread that had some quick-start links for basic how-to. But one that advanced programmers can jump into. I found this video playlist by SoftMotion-Black, which was very, very helpful: https://www.youtube.com/playlist?list=PLkc8m2OD0r9xJyfTiCBb1vuU_d2yBhjZ_ This person has some other great vids like creating your own custom library, which is awesome for OEMS.
Last updated: 2025-05-14

Post by bjohnson on Failed to instantiate the frame window error CODESYS Forge talk (Post)
IT updated a group policy that caused this issue. We resolved by going to Local Group Policy Editor > Local Computer Policy > Computer Configuration > Windows Settings> Security Settings > Local Policies > Security Options. Set "System Cryptography: Use FIPS compliant algorithms for encryption, hashing, and signing" to DISABLED
Last updated: 2025-05-23

Post by naduley on Multiple Branches CODESYS Forge talk (Post)
I am trying to create multiple branches in my project and I keep getting gaps in the ladder logic "wiring". I'm not sure if this is a graphical error or something else but every thing I've tried to do to correct it does not work. Has anyone else run into this or know how to correct it?
Last updated: 2025-06-04

Post by zoppp on Visu Frame-configuration___text will not work CODESYS Forge talk (Post)
Yup, I've been having the exact same issue. A workaround that was working until Visu 4.8.0.0 was using TextList as the type in the frame configuration and then wrapping the text in quotes when configuring it. Im not sure if it will work with variables and I know it does not work if the type is text.
Last updated: 2025-06-17

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
This is a homing routine which is controlled by setting mode of operation and started by setting a bit in the control word. If MC_Home is not usable for this homing method then I need to implement the same functionality. But how?
Last updated: 2025-06-25

Post by davidbo on How do I stop/start logging in my code using AC_Datalog with composer CODESYS Forge talk (Post)
I have on my Pi successfully deployed an application to which with composer AC_Datalog is added. It starts logging automatically. I want a Visualization with a start/stop button controlling the logging. That must be easy. How do I do that?
Last updated: 2025-07-07

Post by paulpotat on Where can I find a list of all available runtime configuration parameters ? CODESYS Forge talk (Post)
Hello, I was wondering if there is a list somewhere of all the parameters that can be used inside the "/etc/codesyscontrol/CODESYSControl_User.cfg" configuration file ? I searched the documentation but didn't find anything. If it doesn't exist, that would be nice to have a little bit more documentation about this file :) Thank you for your help, BR
Last updated: 2025-07-10

Post by installwhat on Opc remote alarms on Linux box CODESYS Forge talk (Post)
It seems that the hmi sl license only works with windows. If i'm happy using web visu, rather than target visu, is possible to use remote opc-ua remote alarms without the hmi sl? Maybe it can be included in a different license that works on Linux? thanks
Last updated: 2025-07-16

Post by wbj0t on one variable signed to modbus tcp server device and modbus serial device CODESYS Forge talk (Post)
Hi. Raspberry pi 4 runtime. Runtime version 4.16, IDE version 3.5.21. Is it possible write new value for variable via modbus tcp or serial devices when both enabled? As I see - not. What can I do? It is terrible restriction.
Last updated: 2025-07-17

Post by timvh on Reading multiple lines from csv file CODESYS Forge talk (Post)
Not sure, but maybe before you enter step 5, set i, lineindex and charIndex to 0. And the buffer variable should have a size bigger than 1 line. Additionally I think you should set bufferstart to 0 before you enter step 5. And in the OSCAT function you always point to the buffer address, but shouldn't this be (buffer + bufferstart)?
Last updated: 2025-07-23

Post by jampid on SFC comments in program CODESYS Forge talk (Post)
Bonjour, Dans les propriétés des étapes et des transitions, tu peux définir les commantaires.Ensuite, il faut activer les commentaires dans OUTILS/OPTIONS/SFC et cocher les cases Commentaires pour les étapes et les transiti deons. Il en est de même pour les MACRO, les SAUTS et les ACTIONS CEI
Last updated: 2025-07-24

Post by davemansell on control loop library IIR filter CODESYS Forge talk (Post)
Hi there i am experimenting with the IIR filter from the control loop library but have been unable to get it to function no matter what inputs I set I get errorID of wrong_configuration (3). Does someone have a working example that they can share. Best regards Dave
Last updated: 2025-07-29

Post by timvh on IECStringUtils.FormatDateTime CODESYS Forge talk (Post)
There has been a fix in SP21. I tried it in this version with the option "Use unicodestring" enabled in the Visualization Manager and it worked if the variables used for the function are declared as WSTRING variables wsFormat : WSTRING := "%t[HH:mm:ss dd.MM.yyyy]"; wsTime : WSTRING; IECStringUtils.FormatDateTime(cbpResult := ADR(wsTime), uiResultCapacity := SIZEOF(wsTime), cbpFormat := ADR(wsFormat));
Last updated: 2025-07-29

Post by aufwindsh on Visualization Scaling the Keypad CODESYS Forge talk (Post)
Hello everyone, is there an option to change the Scaling of the Keypad? I have an 15inch HMI with a resolution of 1920x1080p and the Keypad for the Login of the usermanagement is still to smals to have a great user Experiance. I really appriciate any feedback. Thanks.
Last updated: 2025-08-02

Post by williamjmak1 on Current Visu name without Current Visu Variable CODESYS Forge talk (Post)
Hello everyone, I was just wondering if anybody knows if there's a way to pull the string name of the current visualization without using the current visu variable. I'm working on a project where we don't want web clients to change the current visualization on the HMI of the machine. Thanks!!
Last updated: 2025-08-07

Post by akrawczyk on Dynamically enabling/disabling Modbus slave devices in runtime (performance issue with timeouts) CODESYS Forge talk (Post)
Hi everyone, I'm working on a CODESYS-based project running on a Weintek cMT2078X HMI with a built-in CODESYS runtime. The system communicates with multiple Modbus RTU slave devices, arranged in a cascade. The number of connected units can vary between 2 and 8, depending on the installation. Each slave has 17 Modbus channels, which are polled cyclically every 5 seconds. The issue is that when fewer devices are physically connected (e.g. only 3 out of 8), the Modbus master still attempts to communicate with all configured slaves. This leads to massive delays due to timeouts (currently 200ms per channel). For one disconnected device, that’s: 17 × 200ms = 3.4 seconds of delay per polling cycle, and this quickly multiplies with each additional missing slave. This behavior significantly degrades the system's performance and responsiveness. We attempted a workaround where we tried to trigger polling based on a variable in the PLC program, but this caused instability and even led to hardware hangs/freezes on the cMT2078X – likely due to clashes in how the Modbus polling engine and program logic interact at runtime. My main questions are: Is there a way in CODESYS to dynamically enable/disable Modbus slave devices at runtime, using a BOOL or INT variable (e.g. indicating number of active slaves)? Can devices or channels be conditionally polled or temporarily disabled without removing them from the device tree? Are there any best practices or examples for handling variable numbers of Modbus slaves in scalable systems like this? Would splitting communication across tasks or interfaces help reduce the impact of timeouts? Any advice, documentation references, or architectural suggestions would be extremely helpful. I'm looking for a robust way to dynamically scale slave polling without degrading system stability or performance. Thanks in advance!
Last updated: 2025-08-11

Post by timvh on Current Visu name without Current Visu Variable CODESYS Forge talk (Post)
To change the current visualization for (all) webclients: Add the library “Visu Utils” and use the following example code: VAR xChangeVisu: BOOL; fbChangeVisu : VU.FbChangeVisu; END_VAR // Change to Visu2 when setting xChangeVisu to TRUE fbChangeVisu( xExecute:= xChangeVisu, xDone=> , xBusy=> , xError=> , itfClientFilter:= VU.Globals.OnlyWebVisu, //itfFilter, eError=> , sVisuName:= 'Visu2'); IF fbChangeVisu.xDone OR fbChangeVisu.xError THEN xChangeVisu := FALSE; END_IF
Last updated: 2025-08-13

Post by mqi2r on Newly created texlists wont appear in the selection dropdown CODESYS Forge talk (Post)
For anyone with this issue, you may need to: Open the text list properties (right-click the text list once you create it). Select the Text List tab. Change the Download by option to Visualization. I was fighting this for so long. Once you do that, you should find your text list appears in the drop down when editing a visualisation.
Last updated: 2025-08-19

Post by dkugler on Mail_Service_SL Lib CODESYS Forge talk (Post)
ich meine mich zu erinnern, dass ich schon FB's hatte, die Fehlermeldungen mit löschen des Enable/Execute Bits abgelöscht haben. Dann würde bei dir sobald das Error Bit gesetzt wird, nichts mehr drin stehen. Vielleicht wäre es ein Versuch wert, den String vor dem zurücksetzen des Execute in eine Variable zu speichern, ob dann was drin steht und danach erst ablöschen?
Last updated: 2025-08-20

Post by davemansell on explicit cast ENUM to UINT and vice versa CODESYS Forge talk (Post)
This is from sometime ago but below might help someone else; this could be done via POINTERS. Make sure you protect for NULL pointers etc if you take this approach. // DECLARATION myEnumValue : enumMyEnum; u8 : USINT; pmyEnumValue : POINTER TO enumMyEnum; pu8 : POINTER TO USINT; // CODE pu8 := ADR(u8); pmyEnumValue := pu8; myEnumValue := pmyEnumValue^; // dereference the pointer
Last updated: 2025-08-21