Post by eschwellinger on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
..the missing part is which Softmotion version is installed. Check it in the CODESYS Installer and update it to latest version.
Last updated: 2025-11-10

Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
Is there perhaps a place where I can see examples of programming with different instructions? This would be a great help. Maybe there are some places where ready-made programs are posted that can be downloaded and tested? /Klaus
Last updated: 2025-11-10

Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
I AM VERY GRATEFUL FOR YOUR HELP. I HAVE INSTALLED: CODESYS SOFTMOTION VER. 4.19.0.0 AS SEEN IN THE ATTACHED FILE. BUT IT DOESN'T CHANGE THE FACT THAT I GET 6 ERRORS WHEN I HAVE INSTALLED SM_Drive_RaspiStepper_Direct DO YOU HAVE ANY SUGGESTIONS ON WHAT I CAN DO NOW? /KLAUS
Last updated: 2025-11-10

Post by nano on conformation about the CODESYS Extends SL and CODESYS SDK CODESYS Forge talk (Post)
as an oem i can tell you, extension sl isn't the sdk. its more an hard restricted part of it with much missing parts. why u may ask this?
Last updated: 2025-11-11

conformation about the CODESYS Extends SL and CODESYS SDK CODESYS Forge talk (Thread)
conformation about the CODESYS Extends SL and CODESYS SDK
Last updated: 2025-11-11

Post by nano on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask() CODESYS Forge talk (Post)
have u turned on the Ip-Setter in codesyscontrol.cfg? [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1
Last updated: 2025-11-11

Post by eschwellinger on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
.. try to use this projectarchive for the Stepper. In case you search for SoftMotion Examples: "c:\Program Files\CODESYS 3.5.21.X\CODESYS\CODESYS SoftMotion\Examples\Tutorial\"
Last updated: 2025-11-11

Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Thread)
Stepper motor control with (SM_Drive_RaspStepper_direct)
Last updated: 2025-11-11

Post by davidbo on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask() CODESYS Forge talk (Post)
I have now and it works. I had the idea that it had something to do with codesyscontrol.cfg, but where can I find a description of all the things you can set in codesyscontrol.cfg and its syntax?
Last updated: 2025-11-12

Post by albertovalente on How extract JSONElement containing Array data CODESYS Forge talk (Post)
Hi Creator: hazarath, Have you fix the problem? because I have the same issue Thanks a lot
Last updated: 2025-11-12

How extract JSONElement containing Array data CODESYS Forge talk (Thread)
How extract JSONElement containing Array data
Last updated: 2025-11-12

Post by albertovalente on How extract JSONElement containing Array data CODESYS Forge talk (Post)
Hi Creator: hazarath, Have you fix the problem? because I have the same issue Thanks a lot
Last updated: 2025-11-12

Post by daanyouknow on Using a raspberry pi and NVLs to log variables outside of Codesys CODESYS Forge talk (Post)
Hi, My PLC/controller doesn't support OPC UA, so my current plan to create a ringbuffer/circular logger is to connect a raspberry pi to it, use the Network Variable List receiver and sender and raspberry pi codesys runtime to get the variables to the raspberry pi, after which I will use the pi which DOES support OPC UA to get the variables to a python program which logs the desired variables for a certain amount of time for me, would this work? I don't want to spend 50+ euros + licencing fees for a solution that might not work.
Last updated: 2025-11-14

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hello, I'm asking for help with installing the license server for Linux SL 4.18.0.0. When I try to install it, I get a message that the WIBUCodeMeter package is missing. I checked the package manager tab to see if the package is installed, and it is - Codemeter 8.40.7120.501. I've checked the CodeMeter Runtime on the target machine, and everything seems to be working fine. One thing caught my eye: the Device Architecture tab says "None" Please help me solve this problem.
Last updated: 2025-11-14

Post by adam on Get/Set I/O Address Mapping of DeviceObjects in python Script CODESYS Forge talk (Post)
I want to cancel the automatic address allocation for all IO mappings. If I directly set the automatic_iec_address in class ScriptIoMapping to False, the address becomes None. So I reset manual_iec_address with itselfs value. It only work with the Input IOMapping . For output, it reports an error: "Invalid address: The channel type 'Output' requires address type '%Q'." I checked the description file ,both accessRight are total same. Does anyone know what causes this?
Last updated: 2025-11-14

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
So here's how: I manually installed the following packages: codemeter-lite_8.30.6885.501_amd64.deb codesyslicenseserver_licenseserver_4.18.0.0_all.deb codesyswbmbase_wbmbase_4.18.0.0_all.deb codesyswbmlicensing_wbmlicensing_4.18.0.0_all.deb Of course, the license server appeared immediately. Trying to install it again using Install in the Deploy tab, the same error appears. Of course, the information that such a server is already installed is also there. Configuring PLC, S_PLC, EDGE, and SAFE_TIMER_PROVIDER went smoothly, and basically everything works. I wrote a simple program for S_PLC. I'm loading the programs into PLC and S_PLC. When loading the program into S_PLC, a message appears stating that there is no connection to the S_PLC controller. Timeout error. Restart the controller, attempt to load, and see the above. After changing the cycle time for S_PLC to 50ms, the problem no longer occurs. My question, besides the difficulty of installation for a new user, is what causes the cycle time for S_PLC to be so long, and how can I fix it?
Last updated: 2025-11-14

Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16

Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16

*EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Thread)
EXCEPTION [ProsessorLoadWatchdog] codesys 3.5.11.40
Last updated: 2025-11-16

Post by adam on Get/Set I/O Address Mapping of DeviceObjects in python Script CODESYS Forge talk (Post)
Found out.Its script engine bug . Update to script engine version 4.2.0.0. and problem solved
Last updated: 2025-11-17

Get/Set I/O Address Mapping of DeviceObjects in python Script CODESYS Forge talk (Thread)
Get/Set I/O Address Mapping of DeviceObjects in python Script
Last updated: 2025-11-17

*EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Thread)
EXCEPTION [ProsessorLoadWatchdog] codesys 3.5.11.40
Last updated: 2025-11-17

Post by davidbo on RETAIN PERSISTENT only stored at gracefully shutdown? CODESYS Forge talk (Post)
I have {attribute 'checksumnoinit_override' := '2629838988'} {attribute 'init_related_code' := '5c6efcf8-e0f4-4166-a9fa-17eadd8908df'} VAR_GLOBAL RETAIN PERSISTENT {attribute 'order_in_persistent_editor' := '0'} segmentValue: ARRAY[0..49] OF REAL; {attribute 'order_in_persistent_editor' := '1'} segmentTime: ARRAY[0..49] OF REAL; // Generated instance path of persistent variable PRG.test: INT; // Generated instance path of persistent variable PRG.nw_storage: SysSocket_Implementation.SysSocket_Interfaces.SOCK_ADAPTER_INFORMATION2; END_VAR When I have changed PRG.nw_storage it will not be stored at a power off, but if I do a: sudo systemctl restart codesycontrol and then a power off it will be stored. Is there a way to store persistent variables without a restart of codesyscontrol? Can anyone explain how and when CODESYS store persistent variables?
Last updated: 2025-11-17

Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Post)
Hi All, We downgraded Codesys LAD/FB in the IDE to version 4.5 and it works. Codesys Version 4.6 lad/fb not working. Was the way we fixed this. Kind Regards Shaun
Last updated: 2025-11-17

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
After carefully studying the documentation, I have a question: is a second hardware-independent time source required for the correct operation of the VirtualSafety system?
Last updated: 2025-11-17