Post by bruno-roth on 22kW Wallbox mit Modbus CODESYS Forge talk (Post)
Hallo, das ist wohl das falsche Forum für Wallboxen :-) Aber ich empfehle dir Die GO-E-Charger die hat eine sehr offene Schnittstelle und API auch mit Modbus TCP https://github.com/goecharger/go-eCharger-API-v2/blob/main/modbus-de.md
Last updated: 2025-11-17

22kW Wallbox mit Modbus CODESYS Forge talk (Thread)
22kW Wallbox mit Modbus
Last updated: 2025-11-17

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
The machine I'm currently using (Celeron J1900) already has the Kernel RT patch. I checked the performance according to the documentation. After running CyclicTest for 4 cores, the value for each core is around 6-7. I went through the entire process according to the documentation (I envy the TaskMonitor results in the documentation). The documentation states: "CODESYS Virtual Safe Time Provider The CODESYS Virtual Safe Time Provider is a standard interface that the user can use to transfer a second and external time base to the CODESYS Virtual Safe Control. The implementation is done as a client, which must run on another system with an independent time base." How do I implement this? I've been struggling for two weeks now - I'm too old to give up.
Last updated: 2025-11-17

Post by ppanchal on Add a dynamic text on One Visualization from another CODESYS Forge talk (Post)
I've created a TitleBar Visualization in which I have "Logo" on the Left corner, "Screen Name" in the center and Time/ date on the right corner. I've also created a 'Menu" visualization that slides out from left to right. I have TitleBar and Menu Visualizations in the MainScreen (3rd Visualization). I want to have "Screen Name" automatically updated on TitleBar Visualization based on Menu item selected from the "Menu" visualization. Can anyone advise how can I achive this? TIA
Last updated: 2025-11-18

Add a dynamic text on One Visualization from another CODESYS Forge talk (Thread)
Add a dynamic text on One Visualization from another
Last updated: 2025-11-18

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hi, just use the deploytool to deploy the Timeprovider on this external device: An set the IP of you SafeControl PLC
Last updated: 2025-11-18

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hello, Basically, everything is clear to me. There's still the issue of a TimeProvider for an external device. This may be a stupid question, but I can't find this package. And of course, the question is, can the RPi machine be an external provider? Has anyone tested such a solution?
Last updated: 2025-11-18

Post by seler on Custom button with output status CODESYS Forge talk (Post)
Hi, Im struggle with making custom button. The idea is simple grey light bulb after touch (input var) it changes to yellow but shows output var status not switch status. So if light is physically on, switched by physical switch, bulb is also yellow. How to do it?
Last updated: 2025-11-18

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Thank you for the information and support - I need to think this through again.
Last updated: 2025-11-18

Codesys v 3.5 to factory IO CODESYS Forge talk (Thread)
Codesys v 3.5 to factory IO
Last updated: 2025-11-20

Post by althafu on Codesys v 3.5 to factory IO CODESYS Forge talk (Post)
I have been following the steps shown in the RealPars video to connect CODESYS with Factory I/O. The connection works correctly when I use Ladder Diagram, but when I try the same simple input–output logic in Structured Text, the simulation does not behave as expected. Has anyone experienced this issue or knows what might be causing it?
Last updated: 2025-11-20

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
As I see from your logs I think the Timeprovider is not accurate enough in your case. Things to check - at the moment you run it on the same device? (for tesing purpose ok) I would set 127.0.0.0 as IP and set it not really to Core 0 ( many other stuff is there)
Last updated: 2025-11-20

Post by tristan on Textfield display problem CODESYS Forge talk (Post)
Hello everyone, I have a little problem with textfield display. When I put a solid backgroud, no problem. But when I put it to invisible, some strange things appears with the text. Do you have this kind of issues ? Thanks a lot, Tristan
Last updated: 2025-11-20

Post by timvh on runtime dynamic modbus devices CODESYS Forge talk (Post)
Maybe the ModbusFB library is a good option for you. See: https://forge.codesys.com/prj/codesys-example/modbus/home/Home/
Last updated: 2025-11-21

Post by timvh on Using a raspberry pi and NVLs to log variables outside of Codesys CODESYS Forge talk (Post)
Yes, this will work.
Last updated: 2025-11-21

Using a raspberry pi and NVLs to log variables outside of Codesys CODESYS Forge talk (Thread)
Using a raspberry pi and NVLs to log variables outside of Codesys
Last updated: 2025-11-21

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Thank you for your response. Is there documentation for the commands? I spent a lot of time trying to figure this out. I have a potato computer at home, so I'll have to test this later.
Last updated: 2025-11-21

Deploy LicenseServer for Linux SL CODESYS Forge talk (Thread)
Deploy LicenseServer for Linux SL
Last updated: 2025-11-21

Post by kenth1973 on MC_Phasing state explenation CODESYS Forge talk (Post)
My MC_Phasing FB was stuck in iPhasingState=1 and error output HIGH on one axis. I could manually overwrite the state to 0 in the instance data. During normal run I see the state change from 0 to 10 to 100 back to 0 (maybe more states that I couldnt catch with the naked eye) But - what are the states numbers and their different explenations? This is not explained in the FB guide on codesys. (the pictures show state = 0 after I reset)
Last updated: 2025-11-22

NO SIGNAL ON POWER_ON FOR STEPPER MOTOR CODESYS Forge talk (Thread)
NO SIGNAL ON POWER_ON FOR STEPPER MOTOR
Last updated: 2025-11-24

SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP CODESYS Forge talk (Thread)
SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP
Last updated: 2025-11-24

Post by msirotkin on EtherCAT status errors CODESYS Forge talk (Post)
Hello, I'm trying to understand the reason for the many errors on the EtherCAT master status page. If we set the cycletime to 1ms we see a lot of rxerrors and lostframes, but the send and recive times are quite good (see attachement). And the status of the EtherCAT bus is good (no other errors, all is green, slave has no errors) But when we set 2ms cycletime the lostframe errors are gone, but periodically increses rxerror counter (see attachement). The questions is, what do these errors actually mean and what we can do to get gid of them? Linux RT, imx8, Codesys runtime for ARM 3.5.21.10, Ethercat 4.10 Thanks
Last updated: 2025-11-25

Post by mr-ege on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
Hi all! I'm trying to learn PLC Programing. Today I was making a simple PLC program, as you can see. When I compile the program without the visualization, there are no errors. However, when I add the visualization and then compile it, I get this error. I don’t know how to solve the problem. I have tried the following solutions: rebooting the PC and updating the software. Error Code: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr Compile complete -- 1 errors, 0 warnings Build complete -- 1 errors, 0 warnings : No download possible Version: CODESYS V3.5 SP21 Patch 3
Last updated: 2025-11-25

Post by eschwellinger on EtherCAT status errors CODESYS Forge talk (Post)
Setting IRQ priorities using shell commands irq-list and irq-set-prio for the network adapter which is used for Ethercat. This is here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization_linux.html
Last updated: 2025-11-25

Post by dinesh-vamtec on RETAIN PERSISTENT only stored at gracefully shutdown? CODESYS Forge talk (Post)
I have an idea to save the persistent variable. Currently in testing processs. If testing completed I share the solution to you.
Last updated: 2025-11-26