symbol config - IecVarAccRegisterInstance - error
CODESYS Forge
talk
(Thread)
symbol config - IecVarAccRegisterInstance - error
Last updated: 2025-12-14
Post by eschwellinger on symbol config - IecVarAccRegisterInstance - error
CODESYS Forge
talk
(Post)
which plc in which version do you use?
Last updated: 2025-12-14
Post by timvh on Version management
CODESYS Forge
talk
(Post)
This depends on what you want to achieve with installing the latest version and how you manage your projects and repositories. Maybe you also want to update your device (right click on it to update) or maybe your device is depending on certain versions of libraries (go to the library manager in your project and download the missing libraries). An option is also to first create a projectarchive of the current project you have before you install a new version of CODESYS. Then you can open this projectarchive in the new CODESYS version. Especially if you install the latest version of CODESYS in a Sandbox.
Last updated: 2025-12-15
Post by rettore84 on Trafo 6DOF
CODESYS Forge
talk
(Post)
I didn't have a single reference. I used several sources through online reaserach.
Last updated: 2025-12-15
How can adding a colored leather vest upgrade a simple outfit?
CODESYS Forge
talk
(Thread)
How can adding a colored leather vest upgrade a simple outfit?
Last updated: 2025-12-15
Trafo 6DOF
CODESYS Forge
talk
(Thread)
Trafo 6DOF
Last updated: 2025-12-15
Post by gseidel on SMC_ERROR SMC_CGR_INVALID_POSPERIOD
CODESYS Forge
talk
(Post)
Hi blitz, that usually means that the modulo period, when converted to increments, is larger than 2^31. (The bus bandwidth is usually 2^32.) What is your "technical unit", do you program in angular degrees? And what is the modulo period? If you want you can post the drive configuration (screen shot of the "General" and "Scaling/Mapping" page). Best regards, Georg
Last updated: 2025-12-16
SMC_ERROR SMC_CGR_INVALID_POSPERIOD
CODESYS Forge
talk
(Thread)
SMC_ERROR SMC_CGR_INVALID_POSPERIOD
Last updated: 2025-12-16
Post by pernockham on Trend legend naming and access/config to/of trend/legend-variables
CODESYS Forge
talk
(Post)
Trying the web-version of trend-data. This seems to be a impressive tool, but I lack/cant find a number of what I would think are important parts. There does not seem to be a way to get away from the dot.notated variable naming in the legend.. A developer might want the dot-notation but an end-customer will surely not. For instance I want to display 12 temperatures, instead of t1, t2 etc.. they will be named. gvl_io.unit[1].trend.temps.t1_a gvl_io.unit[1].trend.temps.t1_b gvl_io.unit[1].trend.temps.t1_c gvl_io.unit[1].trend.temps.t2_a .. gvl_io.unit[1].trend.temps.t4_b.. gvl_io.unit[1].trend.temps.t4_c.. Quite a lot of unnecessary text/data taking space from the actual trend => Is there a way to access/interface the legend-data programmatically so I can change the presentation/naming?
Last updated: 2025-12-16
Post by willebro on "Distributed clocks are not synchronized, Rea time problem on hardware" ?
CODESYS Forge
talk
(Post)
https://forge.codesys.com/forge/talk/Engineering/thread/632c29cb93/#8d94 The above comment is the best, but if you just want to see it work you can try disabling the distributed clock. It's not the right thing to do but it should resolve that error.
Last updated: 2025-12-16
Post by gseidel on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi kenth1973, no, we do not have this kind of information on internal variables. iPhasingState has been removed and is no longer present in current versions of SoftMotion. Best regards, Georg
Last updated: 2025-12-17
Post by gseidel on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi kenth1973, it is not a matter of who created the function block. It is just that we don't have, and don't provide, documentation about internal implementation details... Hope you can understand that, Georg
Last updated: 2025-12-17
Post by gseidel on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Hi bertus, I cannot see any problem in the code you posted. Just some ideas: What is the value of D_ANGLE_TOL? - Do you need the assignment bAbort := NOT bDecoder? Does it help to leave it out? Any errors (e.g. SMC_SmoothPath.Error/ErrorID) or PLC log messages? What if you comment out SMC_SmoothMerge and SMC_LimtiDynamics, is corner smoothing still not working? Is bDecode written from a different task (e.g. visu)? Then I would recommend to assign to a local variable (bDecodeLocal := bDecode) and use that for all FBs. Otherwise, FBs might see different values of bDecode in a single cycle, which will cause problems. Regards, Georg
Last updated: 2025-12-17
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi George - ok thanks - but who created this FB in the first place? Could you lead me to the creator company? Is CODESYS not the old S3 that created this FB? :-)
Last updated: 2025-12-17
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi Georg OK got it, thank you. I respect your (CODESYS) policies on that issue. Will try to update according to your recommondation if the customer experience same error in the future. Though - from within my coding heart it does bother me deeply, that I cannot get further understanging/knowledge on the iPhasingState, but I guees I will have to swollow that bitter pill and get on with it! hehe ;-)
Last updated: 2025-12-17
MC_Phasing state explenation
CODESYS Forge
talk
(Thread)
MC_Phasing state explenation
Last updated: 2025-12-17
Post by unusual-data on C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
you can try to disable "Visualization Manager - Settings - Support client animations and overlay of native elements " selection" It worked for me, thank you.
Last updated: 2025-12-18
Post by pernockham on Trend legend naming and access/config to/of trend/legend-variables
CODESYS Forge
talk
(Post)
There seems to have been included an updated in the last release 4.9.0.0 or am I wrong (I think I tried out these settings previously without giving the result I wanted contrary to what I see today)? Now an empty check box for "display variable name" is effective, and will present the Variable with the "Description" instead. Perfect! Seems to be some minor formatting still that needs adjustment. See attached screenshot. The apostrophe "'" between "description" I suppose should not be there? Also I guess the same apostrophe (although not visibly shown) gives an extra space between the variable-description and the ":"?? Thanks!
Last updated: 2025-12-19
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
The option to update "Control for Linux SL" is not shown in the "deploy control SL tool", I can see and update the gateway but not the control (3.5.21 SP4). Has the way to update control SL changed? In the process of fault finding I removed the control SL entirely from my target, then I had to revert to version 3.5.21.0 SP 1 to re-install "Control SL 4.17.0.0". So I thought it was just a matter of using SP1 to update also to 4.18.0.0, but after installing the files for 4.18.0.0 in the SP1-version, the behavior was identical to SP4, ie no Control for Linux SL shown in the deploy tool.. See screenshots.
Last updated: 2025-12-19
Post by aniket-b on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
I am using Scara3 kinematic with EtherCAT PLC. The robot stops at the same place randomly after few cycles. Check attached image. I am getting SMC_ERROR.SMC_DI_FIELDBUS_LOST_SYNCRONICITY in all 3 axes.
Last updated: 2025-12-19
Drive communication errors
CODESYS Forge
talk
(Thread)
Drive communication errors
Last updated: 2025-12-22
Post by mait-tim on Drive communication errors
CODESYS Forge
talk
(Post)
With a machine I'm working with i get a communication error when I'm updating some softstop limits. As soon as I update the code the drives do not want to operate. Using the MC_readStatus I'm receiving errors as soon as i want to start a movement. Using MC_ReadAxisError i see that i receive error 131, no response. With a SMC3_ETC_ReadParameter_CoE i do not recieve any driver errors. Does anyone know how i can figure out what the error is and how to solve it. When i go back to the old software no errors occur. Im working with a legacy machine running a Beijer PLC with some Mitsubishi drives. running on Codesys 3.5 SP10. the runtime version is probably 3.5.3. The drives are all Ethercat Drives (CoE). All using the SM3_drive_ETC libary and the SM3_basic library.
Last updated: 2025-12-22
Post by gseidel on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Hi bertus, thanks for the additional information. Setting bAbort on a restart is not needed. Calling all FBs starting from the decoder up to checkvelocities with bExecute = FALSE and then giving a new rising edge on bExecute is what should be done. Do you also restart the Interpolator? (I don't think that has anything to do with the issue, but still...) Best regards, Georg
Last updated: 2025-12-23
Post by gseidel on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
Hi aniket-b, this error has nothing to do with the scara3 kinematics, or robotics, or SoftMotion. It means that the EtherCAT bus is not synchronized. The usual cause is that the realtime of the PLC is not sufficient. See https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_basic_common_errors.html for details and ways to solve the problem. You can also check the PLC log for additional information about the error. Best regards, Georg
Last updated: 2025-12-23
Post by aniket-b on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
Thanks Georg for responding. I have followed the suggestion mentioned in the real time problem. However, it does not solve the problem. The weird part is, the robot stops at the same position randomly and it does not stop when I increase the speed of the motion.
Last updated: 2025-12-23