Post by davidbo on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Post)
Under Application->"Task Configuration" you can find your task double click on that and you will see a fane to the right. You find the watchdog enable switch it off or increase the time
Last updated: 2025-11-17

Post by davidbo on Clean old license into an image SD CODESYS Forge talk (Post)
That might not be enough using CODESYS V3.5 SP20 and CODESYS Control for Raspberry Pi MC SL version: 4.11 I deleted .cmact_license directory. I installed new license and the dialog box said it was done successfully, but in reality it was not. What more should be deleted 5:/var/opt/codesys$ ls -la total 1948 drwxr-xr-x 10 root root 4096 Nov 17 12:29 . drwxr-xr-x 5 root root 4096 Jul 30 2020 .. -rw-r--r-- 1 root root 100014 Nov 17 12:08 .Audit_0.log -rw-r--r-- 1 root root 100040 Nov 17 11:30 .Audit_1.log -rw-r--r-- 1 root root 100062 Nov 17 09:18 .Audit_2.log -rw-r--r-- 1 root root 66260 Nov 17 12:36 .Audit.log drwxr-xr-x 2 root root 4096 Mar 30 2020 backup -rw-r--r-- 1 root root 2640 Feb 22 2024 bacstac.ini drwxr-xr-x 4 root root 4096 Mar 30 2020 cert drwxr-xr-x 2 root root 4096 Nov 17 12:29 .cmact_licenses drwxr-xr-x 2 root root 4096 Mar 30 2020 _cnc -rw-r--r-- 1 root root 1000088 Nov 17 08:35 codesyscontrol_0.log -rw-r--r-- 1 root root 422521 Nov 17 12:30 codesyscontrol.log -rw-r--r-- 1 root root 355 Nov 17 12:29 .GroupDatabase.csv -rw-r--r-- 1 root root 355 Nov 17 12:19 .GroupDatabase.csv_ drwxr-xr-x 3 root root 4096 Nov 17 11:16 OPCUAServer drwxr-xr-x 6 root root 4096 Mar 30 2020 .pki drwxr-xr-x 9 root root 4096 Nov 17 11:16 PlcLogic -rwxr-xr-x 1 root root 156 Mar 30 2020 rts_set_baud.sh -rw-r--r-- 1 root root 20736 Feb 22 2024 .SoftContainer_CmEmbedded.wbb -rw-r--r-- 1 root root 12445 Nov 17 09:06 SysFileMap.cfg -rw-r--r-- 1 root root 1983 Feb 22 2024 .UFC_SoftContainer_CmEmbedded.WibuC mLif -rw-r--r-- 1 root root 646 Nov 17 09:51 .UserDatabase.csv -rw-r--r-- 1 root root 646 Nov 17 09:51 .UserDatabase.csv_ -rw-r--r-- 1 root root 17305 Nov 17 12:29 .UserMgmtRightsDB.csv drwxr-xr-x 2 root root 4096 Mar 30 2020 visu -rw-r--r-- 1 root root 32684 Feb 8 2023 WibuCtxt.ctx
Last updated: 2025-11-17

Clean old license into an image SD CODESYS Forge talk (Thread)
Clean old license into an image SD
Last updated: 2025-11-17

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
yes it is and it need to be realtime capable with a preempt_rt patched kernel.
Last updated: 2025-11-17

Post by kalmeyer on STEPPER CODESYS SOFTMOTION_DRIVE CODESYS Forge talk (Post)
Hello everyone I have been trying to solve this problem for a long time. Please help me..... I have browsed: https://forge.codesys.com/drv/sm3raspistepper/home/Home/ and it says under "IMPLIMENTATION" that I have to create a POU with the text to be able to use: MC_Power or MC_MoveVelocity How do I write it into the CODESYS program? Thanks in advance /Klaus Kalmeyer
Last updated: 2025-11-17

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
yes it is and it need to realtime capable with a preempt_rt patched kernel.
Last updated: 2025-11-17

Opc UA Data Source Client Browse Error in Codesys HMI CODESYS Forge talk (Thread)
Opc UA Data Source Client Browse Error in Codesys HMI
Last updated: 2025-11-17

Post by tjacks on Opc UA Data Source Client Browse Error in Codesys HMI CODESYS Forge talk (Post)
Codesys V3.5 SP21 Patch 3 Codesys HMI 3.5.21.30 I'm trying to connect to an OPC UA server on a Kuka robot controller using Codesys HMI's data source manager. I get through the login phase and the client browses most of the data structure on the server but errors out toward the end with a generic: Error while browsing the client, Failed with service result: BadUnexpectedError. If I complete the data source setup and try to update variables, I get the attached stack trace for the error. I've tried several different endpoint and security options. Most get me through the login but all error out while browsing. UA Expert happily connects and browses with the same configuration. I've connected this same version of Codesys to TwinCAT OPC UA servers and Siemens PLC OPC UA servers. Any ideas on what may be causing the generic BadUnexpectedError during OPC UA server browse?
Last updated: 2025-11-17

'keep last value' option in CODESYS EtherCAT CODESYS Forge talk (Thread)
'keep last value' option in CODESYS EtherCAT
Last updated: 2025-11-18

Post by ryusoup on 'keep last value' option in CODESYS EtherCAT CODESYS Forge talk (Post)
Hello, I’m using CODESYS EtherCAT Master on a Raspberry Pi controller with several remote I/O modules. I’m facing an issue where the input values from the remote I/Os drop to 0 when a connection error occurs. Is there a way to configure a “keep last value” behavior (i.e., hold the last valid input) instead of defaulting to 0 on communication loss? Best regards,
Last updated: 2025-11-18

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
for the package you net to install 32bit support(to have the native timprovider availble to deploy) sudo apt-get install libc6:i386 Then native Safeplc and native Safetimeprovider should be available to install. Raspi yes - but there is no official package available till now and you need have a rt_preemt patched kernel on the Pi, then it works like charm
Last updated: 2025-11-18

Fuzzy Logic PID Controller CODESYS Forge talk (Thread)
Fuzzy Logic PID Controller
Last updated: 2024-04-24

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Good morning, I'm digging into this topic because I'm curious about resolving my problem in a test environment. In my previous message, I asked about the CODESYS Safe Timeprovider SL package (4.18.0.0), which I saw in the illustration. I noticed that it runs as a service. I am asking about this because from the perspective of an "ordinary" user, this service provides easier access to the settings of the time provider's operating parameters. The basic time provider configuration is outlined at https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_virtual_safe_time_provider.html. Why my questions? They stem from my specific case, which is experiencing timeout issues. I know that my environment is currently only a test environment. I'm assuming a real-world scenario in which I won't be able to achieve a better result with my configuration, and I will ultimately need to increase the time provider's cycle time. By running the time provider service, I can easily influence the time provider's operation and thus eliminate the problem. I know, I know, safety systems are not life-enhancing extras.
Last updated: 2025-11-19

Post by seler on Custom button with output status CODESYS Forge talk (Post)
Just to clarify. Output for lamp will have two inputs: from plc IN (wall switch) and from visu button. Until now I had separate object for visu button and separate for visu lamp. Now I want it to be one object, bulb icone which will change color on lamp status and yet by touching it will change visu button state. Tried "Switch Image" object but there is no way to assign switch var.
Last updated: 2025-11-19

DataSource CodesysApp V3 CODESYS Forge talk (Thread)
DataSource CodesysApp V3
Last updated: 2025-11-19

Post by grepoo on DataSource CodesysApp V3 CODESYS Forge talk (Post)
Hi, trying to create a datasource in appV3 but it returns error code 259 (not nearer specified) everytime, no matter the device i am using. Any idea of what it might signify ?
Last updated: 2025-11-19

Post by gatto on warning C0195 CODESYS Forge talk (Post)
I answer myself: xyz : ARRAY [1..10] OF BYTE := [10(BYTE#100)] ; // no warning :-)
Last updated: 2025-11-20

warning C0195 CODESYS Forge talk (Thread)
warning C0195
Last updated: 2025-11-20

Post by gatto on warning C0195 CODESYS Forge talk (Post)
Good morning dear codesys users. I'm using 3.5.20.40 and I get this warning C0195 when I assign an initial value to xyz. However, if I do it on a single byte (abc), it doesn't display any warning. Why? VAR_GLOBAL abc : BYTE := 100 ; xyz : ARRAY [1..10] OF BYTE := [10(100)] ; END_VAR
Last updated: 2025-11-20

Post by seler on Custom button with output status CODESYS Forge talk (Post)
I did some work around by adding IN switch on top of OUT bulb picture(SwitchImage) and setting IN switch button to invisible but this is not quite elegant. How to combine it to one visu element?
Last updated: 2025-11-20

Custom button with output status CODESYS Forge talk (Thread)
Custom button with output status
Last updated: 2025-11-20

Post by ggaida on runtime dynamic modbus devices CODESYS Forge talk (Post)
Kurtk, I am working through a very similar scenario. I am curious if you have had any success since your post in implementing dynamic modbus configurations? Thx!
Last updated: 2025-11-20

Post by ggaida on runtime dynamic modbus devices CODESYS Forge talk (Post)
Kurtk, I am working through a very similar scenario. I am curious if you have had any success since your post in implementing dynamic modbus configurations? Thx!
Last updated: 2025-11-20

Post by antonz on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Post)
That's what I found as well Shaun. I have seen it at least in versions 3.5.21.1 and 3.5.21.3. There seems to be an issue with the FBD/LD package v4.6.0.0. The workaround proposed by Tim works but needs to be done manually on every code change/addition. For now we manually downgrade the FBD/LD package from v4.6.0.0 down to v4.5.0.0 after installation of CoDeSys. Same as you did. I hope this gets fixed on a next patch.
Last updated: 2025-11-21

Post by timvh on Textfield display problem CODESYS Forge talk (Post)
Did you test this with the latest version of the CODESYS Visualization add-on? Something that you might want to test is if it works better when you disable the "Support client animation and overlay of native elements". Double-click on the VisualizationManager in your project to find this setting.
Last updated: 2025-11-21