Post by tobiassantos on History of Alarms CODESYS Forge talk (Post)
I am running tests using the Windows runtime environment. The alarm history is not being logged and displays the error: "Some kind of disk I/O error occurred. Check disk space" in the alarm table. Furthermore, it is not possible to export the alarms. I have already tried to find a configuration field in Alarm storage and Alarm configuration to fix this problem, but I haven't found any related fields.
Last updated: 2026-01-05

CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Thread)
CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
Last updated: 2026-01-06

Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06

CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Thread)
CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
Last updated: 2026-01-06

Post by aniket-b on Scara3 kinematic robot error CODESYS Forge talk (Post)
@eschwellinger any suggestions here?
Last updated: 2026-01-06

Post by gseidel on Axis directions in CNC editor not using right-hand rule? CODESYS Forge talk (Post)
Hi bertus, the coordinate systems used in SoftMotion CNC are all right-handed. The CNC editor uses isometric projection. This can be confusing, as in your example. The y-axis seems to point into the screen, away from the viewer. However, this is just an optical effect. If you turn on the (experimental) perspective projection (must be added to the CNC tool bar using tools->customize), you can see that the coordinate system is in fact right-handed. Best regards, Georg
Last updated: 2026-01-07

Post by gseidel on Scara3 kinematic robot error CODESYS Forge talk (Post)
Last updated: 2026-01-07

Post by gseidel on Scara3 kinematic robot error CODESYS Forge talk (Post)
Hi aniket-b, the maximum cycle time of the EtherCAT_Task is very high, ca. 35 ms. Could you please check if this is just the first cycle after starting the application or if it happens during motion? (You can reset the times in the task configuration by right-clicking in the "monitoring" tab.) Another thing to try: put the SoftMotion_Planning task on a different core. Best regards, Georg
Last updated: 2026-01-07

Post by mawaloc on KeyPad Function in Visualization to fill a table CODESYS Forge talk (Post)
Hello Everybody, Hope you're all doing good for this new year. Since a time, I'm looking on how to use the KeyPad in vizualization to fill a textlist or something similar. my application is : In one window, I would need to be able to writte a string linked to an Numeric Values. => I can't use a std text list inside my software, as per this would be custom by customer. then from another windows I would need a "text box" to be able to select any of this String. I hope it's clear enought. thankyou for the help
Last updated: 2026-01-07

Post by timvh on KeyPad Function in Visualization to fill a table CODESYS Forge talk (Post)
Create an array of STRING and 1 INT variable, e.g.: asMyString : ARRAY[0..9] OF STRING; iIndex : INT; Then place a "Table" object in the visualization: - link this to the string array variable. - Check the option "Use Template" - Then in the Input Configuration - add the "Write Variable" command Somewhere else add a "Combobox, array" - link this to the same array. - And link the index to the INT variable. In the Combobox, you can then select one of the strings from the array. The index variable will indicate which selection has been made.
Last updated: 2026-01-08

Post by bertus on Axis directions in CNC editor not using right-hand rule? CODESYS Forge talk (Post)
Ok that explains things, thanks.
Last updated: 2026-01-08

Axis directions in CNC editor not using right-hand rule? CODESYS Forge talk (Thread)
Axis directions in CNC editor not using right-hand rule?
Last updated: 2026-01-08

Post by blitz on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
This code works well: PROGRAM PLC_PRG VAR execute : BOOL; abort : BOOL; doMDI : BOOL; manualDataInput : STRING(1024) := 'N5 G01 X0.00 Y200.00 N6 G01 X200.00 Y200.00 N7 G01 X200.00 Y0.00 N8 G01 X0.00 Y0.00'; stringStreamArray: ARRAY[0..NUMBER_OF_CHAINS-1] OF SMC_StringStream2 ; i : UDINT; readNCFromStream : SMC_ReadNCFromStream; sentencesFromStringSteam : SMC_GSentenceQueue ; interpreter : SMC_NCInterpreter; interpreterGeoInfoBuffer: ARRAY[1..GEO_INFO_BUFFERS_SIZE] OF SMC_GeoInfo; roundPath : SMC_RoundPath; roundPathGeoInfoBuffer: ARRAY[1..GEO_INFO_BUFFERS_SIZE] OF SMC_GeoInfo; END_VAR VAR CONSTANT MDI_FILE_NAME : STRING := 'MDI.nc'; NUMBER_OF_CHAINS : UDINT := 15; GEO_INFO_BUFFERS_SIZE : DINT := 500; END_VAR readNCFromStream.bExecute := interpreter.bExecute := roundPath.bExecute := execute; readNCFromStream.bAbort := interpreter.bAbort := roundPath.bAbort := abort; IF doMDI THEN stringStreamArray[0].Init(MDI_FILE_NAME); stringStreamArray[0].AppendData(manualDataInput); stringStreamArray[0].SetEndOfData(); i := 0 ; WHILE i < NUMBER_OF_CHAINS DO readNCFromStream.aStream[i] := stringStreamArray[i]; i := i + 1 ; END_WHILE readNCFromStream.bExecute := TRUE; IF readNCFromStream.bBusy THEN ; END_IF END_IF readNCFromStream( fDefaultVel := 10, fDefaultAccel := 10, fDefaultDecel := 10, fDefaultVelFF := 10, fDefaultAccelFF := 10, fDefaultDecelFF := 10, sentences := sentencesFromStringSteam ); interpreter( sentences:= sentencesFromStringSteam, nSizeOutQueue:= SIZEOF(interpreterGeoInfoBuffer), pbyBufferOutQueue:= ADR(interpreterGeoInfoBuffer)); roundPath( poqDataIn := interpreter.poqDataOut, dRadius := , dAngleTol := , nSizeOutQueue := SIZEOF(roundPathGeoInfoBuffer), pbyBufferOutQueue := ADR(roundPathGeoInfoBuffer));
Last updated: 2026-01-09

"Distributed clocks are not synchronized, Rea time problem on hardware" ? CODESYS Forge talk (Thread)
"Distributed clocks are not synchronized, Rea time problem on hardware" ?
Last updated: 2026-01-09

The New Addictive 8x8 Grid Puzzle Game CODESYS Forge talk (Thread)
The New Addictive 8x8 Grid Puzzle Game
Last updated: 2026-01-09

Post by julianramirez on Visu 4.9.1 auto-logon/login CODESYS Forge talk (Post)
Hello everyone, I have been trying to test the auto-login feature that is advertised on the Release Notes since Visu 4.8: *Version: 4.8.0.0 Besides some bug fixes and improvements this version contains the following new functionality: Alarmmanagement: Possibility to raise alarms programmatically Use real time clock of IEC context Automatic login for WebVisu using Chrome "Sign in automatically"* I am using a personalized login Visualization, the User Management works, however, when ticking the checkbox that keeps the credentials stored, after I reload the page I still see that the user and password details are not filled in. I tried with the default Login Visu (Blue one), and still see the same behavior - VisuUserManagement.VUM_LoginVisualization - I've tried with Chrome and Edge. Thanks for your help
Last updated: 2026-01-12

Parker Compax3 controlled by Schneider LMC 201 CODESYS Forge talk (Thread)
Parker Compax3 controlled by Schneider LMC 201
Last updated: 2026-01-13

Post by bruno-roth on Parker Compax3 controlled by Schneider LMC 201 CODESYS Forge talk (Post)
Hello, you could use any CODESYS PLC which has an EtherCAT master and the possibility to run the CODESYS Softmotion.
Last updated: 2026-01-13

Post by aniket-b on Scara3 kinematic robot error CODESYS Forge talk (Post)
After I changed softmotion_planning task to different core, I no longer getting this error. Thanks a lot @gseidel
Last updated: 2026-01-14

Strengthening Professional Identity in Nursing CODESYS Forge talk (Thread)
Strengthening Professional Identity in Nursing
Last updated: 2026-03-03

Continuous Improvement Through Reflective Habits CODESYS Forge talk (Thread)
Continuous Improvement Through Reflective Habits
Last updated: 2026-03-03

Post by remlab on WebClient result empty CODESYS Forge talk (Post)
Hello, I try to read into a IPX800v4 (this is a PLC for domotic application) with a WebClient fonction I use as url http://192.168.0.250:50543/api/xdevices.json?key=XXX&Get=C XXX is replace by the correct key for sure The status code is 200, it should works correctly But the result is '{' that's my problem When I try the same url with a web browser the result is correct like { "product": "IPX800_V4", "status": "Success", "C1": 16, "C2": 2, "C3": 0, "C4": 0, "C5": 0, "C6": 0, "C7": 0, "C8": 0, "C9": 0, "C10": 0, "C11": 0, "C12": 0, "C13": 0, "C14": 0, "C15": 0, "C16": 0 } When i replace the url by a web site like google for exemple it works Can you help me please ?
Last updated: 2026-03-04

Post by remlab on WebClient result empty CODESYS Forge talk (Post)
If I try http://192.168.0.250:50543/api/xdevices.json?key=XXX&SetC1=1 it write correctly Why can I write but I can't read the Json ?
Last updated: 2026-03-04

Post by osande on Archive CODESYS Forge talk (Post)
Problem with Visualization Manager and archiving. Project without VM has no problem. With VM in the project there is an error message and no archive has been created
Last updated: 2026-03-10

Post by osande on Archive CODESYS Forge talk (Post)
V3.5 SP 21 Patch 5
Last updated: 2026-03-10