Post by pernockham on How to recognize licenses SMALL, MEDIUM, LARGE by CmpCodemeter
CODESYS Forge
talk
(Post)
Solved finally, in short by: listening to eventId = EVT_CmpMgr_LicenseState, make a callback, extract the event-parameter which contains the RUNTIME_LICENSE_STATE. This gives me the license state as LICENSED / LICENSED_LOS / DEMOMODE etc. What Im not certain of at this point is this the aggregation of all three licenses or just the RUNTIME? Ie, what if my CONTROL-license is ok but my Visu-license is to low, will that set LICENSE_LOST, or would I need other listeners to find out if my VISU will shut down?
Last updated: 2026-10-07
Post by pernockham on How to recognize licenses SMALL, MEDIUM, LARGE by CmpCodemeter
CODESYS Forge
talk
(Post)
Third update. I figured that even knowing the level of the license, it will not tell me if its level is enough for the current application. There must be some other way to find this out? I see a component CM write in the Log if starting without license-dongle. "License lost - time left.. " Can I access this CM to check status from inside the application? This function is essential, why is it so hard to find info about implementation?
Last updated: 2026-10-06
Post by dmb-fan on From target start Win OnScreenKeyboard
CODESYS Forge
talk
(Post)
Hi ! I am get crazy.... I try to start osk.exe from Visu or PLC. From Visu I can't load it, always error (It change from programm execute always to load receipe ..!?!?) From PLC always freeze of PLC, - I allowed the win service of the PLC the data exchange between desktop and service - I allowed in ..user.cfg [SysProcess] Command=AllowAll Shutdown with SysProcessExecuteCommand works, but 'osk.exe' or the complete path always crashed the system. And like always: No documentation. Just guessing. Or know somebody more and have a link for me? THANKS !
Last updated: 2026-10-27
Post by davidbo on Clean old license into an image SD
CODESYS Forge
talk
(Post)
That might not be enough using CODESYS V3.5 SP20 and CODESYS Control for Raspberry Pi MC SL version: 4.11 I deleted .cmact_license directory. I installed new license and the dialog box said it was done successfully, but in reality it was not. What more should be deleted 5:/var/opt/codesys$ ls -la total 1948 drwxr-xr-x 10 root root 4096 Nov 17 12:29 . drwxr-xr-x 5 root root 4096 Jul 30 2020 .. -rw-r--r-- 1 root root 100014 Nov 17 12:08 .Audit_0.log -rw-r--r-- 1 root root 100040 Nov 17 11:30 .Audit_1.log -rw-r--r-- 1 root root 100062 Nov 17 09:18 .Audit_2.log -rw-r--r-- 1 root root 66260 Nov 17 12:36 .Audit.log drwxr-xr-x 2 root root 4096 Mar 30 2020 backup -rw-r--r-- 1 root root 2640 Feb 22 2024 bacstac.ini drwxr-xr-x 4 root root 4096 Mar 30 2020 cert drwxr-xr-x 2 root root 4096 Nov 17 12:29 .cmact_licenses drwxr-xr-x 2 root root 4096 Mar 30 2020 _cnc -rw-r--r-- 1 root root 1000088 Nov 17 08:35 codesyscontrol_0.log -rw-r--r-- 1 root root 422521 Nov 17 12:30 codesyscontrol.log -rw-r--r-- 1 root root 355 Nov 17 12:29 .GroupDatabase.csv -rw-r--r-- 1 root root 355 Nov 17 12:19 .GroupDatabase.csv_ drwxr-xr-x 3 root root 4096 Nov 17 11:16 OPCUAServer drwxr-xr-x 6 root root 4096 Mar 30 2020 .pki drwxr-xr-x 9 root root 4096 Nov 17 11:16 PlcLogic -rwxr-xr-x 1 root root 156 Mar 30 2020 rts_set_baud.sh -rw-r--r-- 1 root root 20736 Feb 22 2024 .SoftContainer_CmEmbedded.wbb -rw-r--r-- 1 root root 12445 Nov 17 09:06 SysFileMap.cfg -rw-r--r-- 1 root root 1983 Feb 22 2024 .UFC_SoftContainer_CmEmbedded.WibuC mLif -rw-r--r-- 1 root root 646 Nov 17 09:51 .UserDatabase.csv -rw-r--r-- 1 root root 646 Nov 17 09:51 .UserDatabase.csv_ -rw-r--r-- 1 root root 17305 Nov 17 12:29 .UserMgmtRightsDB.csv drwxr-xr-x 2 root root 4096 Mar 30 2020 visu -rw-r--r-- 1 root root 32684 Feb 8 2023 WibuCtxt.ctx
Last updated: 2025-11-17
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
Just to clarify. Output for lamp will have two inputs: from plc IN (wall switch) and from visu button. Until now I had separate object for visu button and separate for visu lamp. Now I want it to be one object, bulb icone which will change color on lamp status and yet by touching it will change visu button state. Tried "Switch Image" object but there is no way to assign switch var.
Last updated: 2025-11-19
Post by kalmeyer on NO SIGNAL ON POWER_ON FOR STEPPER MOTOR
CODESYS Forge
talk
(Post)
I WOULD BE GRATEFUL FOR HELP....✔✔✔ I HAVE SPENT A LOT OF TIME ON THIS "SMALL" PROBLEM😢 I HAVE MADE A MC_POWER FOR STEPPERMOTOR. BUT I DO NOT GET A "HIGH" ON THE STATUS OUTPUT EVEN THOUGH PENABLE, PREG AND PDRIVESTART ARE ACTIVATED ( SEE ATTACHED WRONG_1) HAD I MADE SOME ERROR IN PLC_PRG_1..???? (WRONG_2) 1000 THANKS FOR HELP WITH THIS PROBLEM. 👀👀 /KLAUS FROM DENMARK
Last updated: 2025-11-23
Post by msirotkin on EtherCAT status errors
CODESYS Forge
talk
(Post)
Didn't help. I'm just trying to understand why the errors occur. Are they from the poor driver or from the Linux network stack. That's why I wanted to know how the rxerros and lostframes are counted. Because in other places (like ethtool info) there are no any issues. And the Ethercat device works fine. And it also strange that on the second ethernet port with a different HW and driver Ethercat works better, but still time to time gets such errors.
Last updated: 2025-11-26
Post by tobiassantos on History of Alarms
CODESYS Forge
talk
(Post)
I am running tests using the Windows runtime environment. The alarm history is not being logged and displays the error: "Some kind of disk I/O error occurred. Check disk space" in the alarm table. Furthermore, it is not possible to export the alarms. I have already tried to find a configuration field in Alarm storage and Alarm configuration to fix this problem, but I haven't found any related fields.
Last updated: 2026-01-05
Post by tobiassantos on History of Alarms
CODESYS Forge
talk
(Post)
I am running tests using the Windows runtime environment. The alarm history is not being logged and displays the error: "Some kind of disk I/O error occurred. Check disk space" in the alarm table. Furthermore, it is not possible to export the alarms. I have already tried to find a configuration field in Alarm storage and Alarm configuration to fix this problem, but I haven't found any related fields.
Last updated: 2026-01-05
Post by gseidel on Axis directions in CNC editor not using right-hand rule?
CODESYS Forge
talk
(Post)
Hi bertus, the coordinate systems used in SoftMotion CNC are all right-handed. The CNC editor uses isometric projection. This can be confusing, as in your example. The y-axis seems to point into the screen, away from the viewer. However, this is just an optical effect. If you turn on the (experimental) perspective projection (must be added to the CNC tool bar using tools->customize), you can see that the coordinate system is in fact right-handed. Best regards, Georg
Last updated: 2026-01-07
Post by gseidel on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
Hi aniket-b, the maximum cycle time of the EtherCAT_Task is very high, ca. 35 ms. Could you please check if this is just the first cycle after starting the application or if it happens during motion? (You can reset the times in the task configuration by right-clicking in the "monitoring" tab.) Another thing to try: put the SoftMotion_Planning task on a different core. Best regards, Georg
Last updated: 2026-01-07
Post by timvh on KeyPad Function in Visualization to fill a table
CODESYS Forge
talk
(Post)
Create an array of STRING and 1 INT variable, e.g.: asMyString : ARRAY[0..9] OF STRING; iIndex : INT; Then place a "Table" object in the visualization: - link this to the string array variable. - Check the option "Use Template" - Then in the Input Configuration - add the "Write Variable" command Somewhere else add a "Combobox, array" - link this to the same array. - And link the index to the INT variable. In the Combobox, you can then select one of the strings from the array. The index variable will indicate which selection has been made.
Last updated: 2026-01-08
Post by gseidel on Mismatch between coordinate monitor and actual motion using SMC_GroupJog2, MC_MoveLinearAbsolute (6DOF)
CODESYS Forge
talk
(Post)
Dear darwin03, my first guess is that the axis scaling of the last axis (joint 6) is not correct. It should be confiugured so that one technical unit equals one angular degree. From the video, it rather looks like 1 technical unit is a full revolution of the joint. (This holds for all rotary axes used with SoftMotion Robotics: they must be scaled so that one technical unit equals one angular degree.) Best regards, Georg
Last updated: 2026-04-07
Post by dgross on Alarm Manager History Message Missing
CODESYS Forge
talk
(Post)
Hi All, I'm using a webvisu on a control Win V3 SoftPLC. My issue is with the Alarm Managers Alarm history. It does create entry's and does also show the latch data. But it only shows the message of the active alarms. In the history the message is empty (also in the .csv Export file). The archiving in the alarm group is checked and the Alarm storage is activated. I'm using the Version V3.5 SP22 Patch 1. Do you have any idea where that comes from?
Last updated: 2026-04-20
Post by mohi on Connect to Azure IoT Hub
CODESYS Forge
talk
(Post)
Hello, I try to connect a Controller to Azure IoT Hub using a Root Certificate put on the controller in /etc/ssl/certs und SAS Token for IoT Hub instead of X.509 certificates. The TLS Handshake is successful when I test in terminal using openssl. It seems that the Controller doesn't start this process. I use the Azure IoT Hub library and the Net Base Services. Is there something left or something you can recommend? Best regards Mo
Last updated: 2026-04-24
Post by mohi on Connect to Azure IoT Hub
CODESYS Forge
talk
(Post)
Hello, I try to connect a Controller to Azure IoT Hub using a Root Certificate put on the controller in /etc/ssl/certs und SAS Token for IoT Hub instead of X.509 certificates. The TLS Handshake is successful when I test in terminal using openssl. It seems that the Controller doesn't start this process. I use the Azure IoT Hub library and the Net Base Services. Is there something left or something you can recommend? Best regards Mo
Last updated: 2026-04-24
Post by ph0010421 on ModbusTCP_FunctionCode06
CODESYS Forge
talk
(Post)
Hi You can add a channel to the standard Modbus TCP library with FC06. From the device tree, add Ethernet device, ModbusTCP master then finally a ModbusTCP slave (your power meter). You can add read/write channels (for any FC) in here. As you add these devices, the necessary libraries will be inserted for you. Alternatively, I have a ModbusTCP client/server library if your RT doesn't have Modbus (I think they all do these days?)
Last updated: 2026-05-18
Post by dakmueller on Zielsystem Problem nach Bibliotheken hinzufügen
CODESYS Forge
talk
(Post)
Hallo, ich habe ein altes Projekt geöffnet um auf einer Anlage eine Änderung einzufügen. Beim öffnen haben etliche Bibliotheken gefehlt. Diese habe ich dann installiert und übersetzt. Online kam ich nicht, weil kein Zielsystem angegeben war. Beim Übersetzten gab es keine Meldungen. Als ich das Zielsystem XV-1xx-V2.3.9 SP3 ausgewählt habe und das übersetzt kamen viele Fehlermeldungen. Viele Variablen nicht deklariert. Die Steuerung/HMI ist eine EATON XV-102-E8-57TVRC-10. Hilfe
Last updated: 2026-06-22
Post by dakmueller on Zielsystem Problem nach Bibliotheken hinzufügen
CODESYS Forge
talk
(Post)
Hallo, ich habe ein altes Projekt geöffnet um auf einer Anlage eine Änderung einzufügen. Beim öffnen haben etliche Bibliotheken gefehlt. Diese habe ich dann installiert und übersetzt. Online kam ich nicht, weil kein Zielsystem angegeben war. Beim Übersetzten gab es keine Meldungen. Als ich das Zielsystem XV-1xx-V2.3.9 SP3 ausgewählt habe und das übersetzt kamen viele Fehlermeldungen. Viele Variablen nicht deklariert. Die Steuerung/HMI ist eine EATON XV-102-E8-57TVRC-10. Hilfe
Last updated: 2026-06-22
Post by dakmueller on Zielsystem Problem nach Bibliotheken hinzufügen
CODESYS Forge
talk
(Post)
Hallo, ich habe ein altes Projekt geöffnet um auf einer Anlage eine Änderung einzufügen. Beim öffnen haben etliche Bibliotheken gefehlt. Diese habe ich dann installiert und übersetzt. Online kam ich nicht, weil kein Zielsystem angegeben war. Beim Übersetzten gab es keine Meldungen. Als ich das Zielsystem XV-1xx-V2.3.9 SP3 ausgewählt habe und das übersetzt kamen viele Fehlermeldungen. Viele Variablen nicht deklariert. Die Steuerung/HMI ist eine EATON XV-102-E8-57TVRC-10. Hilfe
Last updated: 2026-06-22
Post by dakmueller on Zielsystem Problem nach Bibliotheken hinzufügen
CODESYS Forge
talk
(Post)
Hallo, ich habe ein altes Projekt geöffnet um auf einer Anlage eine Änderung einzufügen. Beim öffnen haben etliche Bibliotheken gefehlt. Diese habe ich dann installiert und übersetzt. Online kam ich nicht, weil kein Zielsystem angegeben war. Beim Übersetzten gab es keine Meldungen. Als ich das Zielsystem XV-1xx-V2.3.9 SP3 ausgewählt habe und das übersetzt kamen viele Fehlermeldungen. Viele Variablen nicht deklariert. Die Steuerung/HMI ist eine EATON XV-102-E8-57TVRC-10. Hilfe
Last updated: 2026-06-22
Post by ct-f on KOP & FUP in Sp21P6 nicht vorhanden
CODESYS Forge
talk
(Post)
Hallo Zusammen, ich muss ein Projekt von Sp16P4 auf SP21 portieren, einige FBs wurden damals in FUP und KOP erstellt. Zu meiner großen Verwunderung gab es beim kopieren/einfügen eine Fehlermeldung. Jetzt wollte ich in KOP einen leeren FB erstellen, aber es gibt bei mir im Auswahlmenü weder KOP noch FUP. Gibt es eine Erweiterung, welche ich installieren muss? Konnte dazu nichts finden. Beste Grüße Falk
Last updated: 2026-07-23
Post by wollvieh on SP19 Runtime Zugriff auf lokales Dateisystem
CODESYS Forge
talk
(Post)
Hallo, hier in diesem Beispiel ist $Download$ ein Platzhalter für den kompletten Pfad /home/pi/Downloads/ auf dem Zielsystem, wo die SoftPlc läuft. In der SoftPlc gibt man dann als Dateipfad und Dateiname wie folgt an : '$$Download$$/Datei.txt' Die Datei Datei.txt wird dann auf dem Zielsystem unter /home/pi/Downloads/ angelegt. Pfade darunter werden auch angelegt, z.Bsp.: '$$Download$$/Ordner1/Datei.txt' Beispiel des Platzhalters: [SysFile] PlaceholderFilePath.2=/home/pi/Downloads/, $Download$
Last updated: 2026-01-22
Post by gseidel on CAM Motion Recover after STO
CODESYS Forge
talk
(Post)
Dear Mr. Kolev, can you please explain a little more: what happens at an STO? I assume the slave axes will be stopped and retain their current position? How, then, do you call MC_CamIn after the STO? Do you restart it with a new rising edge, but on the same master position as before the STO? Which StartMode are you using, is the cam slave absolute or relative, master absolute or relative? Are the slave axes modulo or finite axes? Best regards, Georg Seidel
Last updated: 2026-02-13
Post by nehaltrivedi96 on Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Post)
Hello, I am currently scaling 4-20mA signals and the scaled output (temperature) has to be sent via modbus protocol to a tool like doctor modbus or modbus poll. I have defined my inputs as real as and the output is also real, but to send this output via modbus it has to be of word. So how will i convert real into word and then send the generated output via modbus?
Last updated: 2026-02-18