Post by mascara on JOG continues in WCS ( SMC_GroupJog2 )
CODESYS Forge
talk
(Post)
I'm using the SMC_GroupJog2 block from the SM3_Robotics library for manual movement of an AxisGroup in WCS coordinates. The observed behavior is: When pressing X+, the X-axis starts moving correctly. If I press Y+ during the movement, the block interrupts the current movement and starts a new movement in X and Y. If I release any button, all axes stop, even if another button is still pressed. Example: Pressing X+ → X moves Pressing X+ and Y+ → X stops momentarily and starts XY movement Releasing X+ while holding Y+ → all axes stop The expected behavior would be: to allow simultaneous continuous movement on multiple axes to not interrupt movement when another axis is added or removed. Is there a correct configuration of SMC_GroupJog2 to achieve this behavior, or is there another block more suitable for continuous manual jog in AxisGroup (WCS)?
Last updated: 2026-03-11
Post by pernockham on Images not shown in webvisu
CODESYS Forge
talk
(Post)
Two issues. Ive been struggling to get the user management the way I want it. I want to protect the device from unauthorized upload/download, but I do not want login requirement on webvisu. The combination that seems to work is to use "runtime device user management" while keeping the visu user management in "legacy mode"? Initially this seemed to work, but now images are not loaded when using direct access, while they are still shown if I access the webpage via Automation server. Im guessing its connected to the authorization changes? Anyone able to help out? Thanks Also, I read that legacy mode should be avoided, is it possible to use "runtime based visu user management" while keeping direct access to the webpage without login. System is a "Control for linux SL, version 4.20.0.0" Per
Last updated: 2026-04-10
Post by reinier-geers on internal error
CODESYS Forge
talk
(Post)
Hi ive got an internal error. BUt no solution for this. How do i solve this ? ------ Build started: Application: Slave_3.Application ------- [ERROR] Internal error:System.NullReferenceException: De objectverwijzing is niet op een exemplaar van een object ingesteld. bij _3S.CoDeSys.ObjectManager.ExistingPSNode.get_ParentObjectGuid() bij _3S.CoDeSys.ObjectManager.AbstractPSNode.get_ParentNode() bij _3S.CoDeSys.ObjectManager.ProjectStructure.ConsolidateAndClearPendingChanges(LList`1 pendingChanges) bij _3S.CoDeSys.ObjectManager.ProjectStructure.RaisePendingChanges(Boolean bTriggerPendingChanges2) bij _3S.CoDeSys.ObjectManager.Project.HandleUndoMgrAfterEndCompoundAction2(EventArgs e) bij _3S.CoDeSys.ObjectManager.UndoManager.OnAfterEndCompoundAction2(EventArgs e) bij _3S.CoDeSys.ObjectManager.UndoManager.EndCompoundAction() bij _3S.CoDeSys.DeviceEditorSoftMotion.StaticSoftMotionEditor._ehBeforeCompile(Object sender, CompileEventArgs e) bij _3S.CoDeSys.Core.LanguageModel.CompileEventHandler.Invoke(Object sender, CompileEventArgs e) bij _3S.CoDeSys.Core.LanguageModel.CompileEventHandler.Invoke(Object sender, CompileEventArgs e) bij _3S.CoDeSys.LanguageModelManager.LanguageModelManagerConsolidated.OnBeforeCompile(CompileEventArgs e) bij _3S.CoDeSys.LanguageModelManager.LanguageModelManagerConsolidated.RaiseAndCheckBeforeCompile(Guid guidApplication, IMessageCategory cmc) bij ..(Boolean , Boolean , Boolean ) bij _3S.CoDeSys.Compiler35210.CompilerPhases.CompilerPhaseControllerGenerateCode.(Boolean ) bij _3S.CoDeSys.Compiler35210.CompilerPhases.CompilerPhaseControllerGenerateCode.() Build complete -- 1 errors, 0 warnings : No download possible
Last updated: 2026-04-14
Post by darwin03 on Mismatch between coordinate monitor and actual motion using SMC_GroupJog2, MC_MoveLinearAbsolute (6DOF)
CODESYS Forge
talk
(Post)
Dear Georg, Thank you for your explanation about the axis scaling. I checked the scaling of Joint6 and corrected it so that one technical unit equals one angular degree. However, I am now facing another issue. When I move all axes to zero position and then try to use SMC_GroupJog2 and MC_MoveLinearAbsolute, I receive the error SMC_CP_CONFIGS_DIFFER I already tried moving each joint manually to different positions before executing the motion command, but the error still appears. Could you please explain: What exactly causes SMC_CP_CONFIGS_DIFFER Thank you very much for your support. Best regards, darwin03
Last updated: 2026-05-04
Post by baotthitawat on Why Structured SCADA Documentation Matters in Modern Industrial Systems
CODESYS Forge
talk
(Post)
Modern SCADA development is no longer limited to monitoring dashboards and PLC communication. Today’s industrial systems often require: Cloud architecture Web & mobile SCADA API integration IIoT communication Alarm management Scalable deployment workflows One challenge in many projects is that deployment knowledge is usually scattered across multiple documents, configuration guides, and troubleshooting references. As systems become more connected, engineers need a more structured learning approach to reduce deployment time and improve maintainability. The ATSCADA Training Book is an interesting example because it organizes the ecosystem into a clearer roadmap covering: SCADA architecture Driver & OPC communication Web visualization Mobile applications Cloud & IIoT systems Troubleshooting & maintenance I think structured technical documentation will become increasingly important as industrial automation systems continue evolving toward larger and more connected environments.
Last updated: 2026-05-27
Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
I think I understand my problem. They are most probably related to configuration of the network. When I use DHCP for the unit to my router it all works. However when using static IP I have not managed to reach functioning state. Trying to replicate the situation on my desk. Having a static IP on the "debian host" and a connection to my computer which then routes traffic on to internet. I have entered settings for gateway and netmask. I can ping from my "debian plc host" to internet and also do "curl google.com" so traffic seems to find its way through and back, still "Automation server" will not find the gateway. Any hints how a manual configuration should be done? Is it possibly a "firewall" issue of my "normal router"? Thanks for any help! Per
Last updated: 2026-01-27
Post by konstantin on Lenze i950 Servo and WAGO PFC200
CODESYS Forge
talk
(Post)
Hello, basically the i950 drive support CiA402 Basic and CiA402 Advanced modes. I attached pictures of both mode supported functions. It also support CSP, VL, CSV and CST modes. It seems the homing mode is in CiA402 Advanced mode but how can you not have the homing mode in both modes? It is a vital part of any servo system. If I use the SoftMotion standard demo mode, I can move the servo absolute and relative but cannot home it. But in SoftMotion Light mode, I cannot execute any motion function. Here is the official manual for i950 servo drive - i950 Documentation Best Regards Konstantin Kolev
Last updated: 2026-02-13
Post by gordonkeller360 on Escape character behavior for hex values in string -- what gives?
CODESYS Forge
talk
(Post)
I have a program which sequentially places byte representations of characters from a string into an array. FUNCTION_BLOCK MoveBytesFromString VAR_IN_OUT abRxBuf: ARRAY [0..79] OF BYTE; END_VAR VAR testString : STRING := '$0A$R$L$TTesting,123...$94$86$0A'; iCount: DINT; END_VAR ---------------------------------------------------------------------------------------- // clear the buffer MEM.MemFill(ADR(abRxBuf), 80, 0); FOR iCount := 0 TO LEN(testString) - 1 DO // account for undesired null terminator of string abRxBuf[iCount] := testString[iCount]; END_FOR Escaped characters, like $T, $N, etc. work just fine, and so do their hex representation counterparts ($09, $0A, etc). However, when I put something like $94, I get a set of nonsense values... see image attached after one spin of the program. Could someone explain to me what is happening here? I'll continue to investigate...
Last updated: 2026-03-09
Post by poliautomacao on Absolute movement controlled by an external encoder.
CODESYS Forge
talk
(Post)
Hello, I made this configuration, I'm moving the encoder value to SM_Driver_PosControl.in.wActPosition. When I make the absolute movement of my PosControl axis, my physical drive axis rotates perfectly, but I noticed that the movement is not followed by the encoder. That is, if I hold the encoder and keep it in position 0, the PosControl axis makes the absolute movement of 314 mm and stops, which is strange because the encoder is at 0. Theoretically, the PosControl axis should accelerate to try to compensate for the movement error. I haven't yet achieved perfect functionality.
Last updated: 2026-03-24
Post by jorenbeyl on library inside library
CODESYS Forge
talk
(Post)
I am currently developing a library that contains real‑time data. To handle this real‑time data, I am using additional libraries called SysTime and SysTypes Interfaces. When I compile my library on its own, no errors occur. However, when I use this library in a project and compile the project, I get an error indicating that the SysTime data type is not recognized. This happens even though the SysTime library is visible as a dependency under my library. Does anyone know how to correctly include a library within another library so that the project recognizes the sub‑library without causing compilation errors?
Last updated: 2026-04-23
Post by polo on 1 Wire und i2c zeitgleich in Betrieb
CODESYS Forge
talk
(Post)
Hallo zusammen, ich habe schon einige Zeit 16 DS18B20 am 1 Wire laufen ... auch die ganze Zeit stabil ... jetzt habe ich ein PWM Signal über i2c für eine Pumpenansteuerung zusätzlich in Betrieb genommen.. nur das Signal für die Pumpe geht über i2C ... 100Hz 10ms. Es läuft auch alles soweit ... nur fallen mir jetzt die Temperaturen in Abständen aus ... Vertragen sich die beiden Systeme zeitlich evtl. nicht so gut ... 1 wire extra task mit 200ms Prio 0 i2c task 10ms ... damit die 100Hz auch übertragen werden Prio 1 (Adafruit_PWM) Main Task 20ms Prio 5 Oder jetzt besser beides über i2c abrufen ... ist aber dann evtl. für die DS18B20 zu schnell ? Oder sind die 5V vom Pi jetzt zu schwach für beide Signale? Vielen Dank euch
Last updated: 2026-04-27
Post by kurt9 on ReadWriteEEprom FB question
CODESYS Forge
talk
(Post)
I want to programmatically write the alias address to a new EtherCAT slave when I plug it into my IPC EtherCAT network. I am looking at the ReadWriteEEprom FB and see that one of the elements is "pbyData". which is the pointer to byte that is usually set to 2048 bytes. Since I am setting the alias address to the EEprom only (EEprom address 16#0012), I would assume that what I am writing is 2 bytes only. Does the pbyData have to be specified as ADR(myArray) where "myArray" is the 2 bytes of the alias address? How is the best way to set this element of the function block? Thanks in advance
Last updated: 2026-05-18
Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring
CODESYS Forge
talk
(Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26
Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring
CODESYS Forge
talk
(Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26
Post by dmb-fan on Nach "Alles Bereinigen" viele unklare Fehler, aber nur in Schrittketten
CODESYS Forge
talk
(Post)
Mit viele ausprobieren habe ich es einkreisen können: Es scheint NICHT mit einer Variablen Deklaration zusammenzuhängen. Wenn ich einen Parallel-Zweig lösche ist der Fehler für den betroffenen Baustein weg. Nur ein einzelne Step ohen Aktion reicht für den Fehler. Schritt löschen reicht nicht. Zweig löschen und Schritt neu mache: Fehler scheint weg zu sein.... Da ich das öfters und in größeren Bausteinen habe, möchte ich es vermeiden es händisch zu löschen und neu zu erstellen. (Speziell mit dem komischen Editor..) Ist das eine Compiler Fehler? Gibt es sowas wie ein "Datenbank bereinigen" / ReOrganisieren? Sonstige Tipps? PS: Ist die 64-Bit Version. PSS: Auf ersten Blick scheint es mit der 32 Bit Version zu klappen...??
Last updated: 2026-09-21
Post by thommy54 on CODESYSControl_User cfg richtig konfigurieren
CODESYS Forge
talk
(Post)
Hallo, nach Erwerb eines neueren Raspberry pi 4 (V1.5) musste ich zwangsläufig von Codesys 3.5.16 hochwechseln - ich habe auf 3.5.20.1 geupdated. Da schlugen mir plötzlich ne Menge Einschränkungen entgegen, deren Behebung einige Zeit dauerte. Eine davon ist, das ein SysFile.SysFileOpen nicht mehr funktioniert. Ich habe das Problem mit Einträgen in der /etc/CODESYSControl.cfg behoben: [SysFile] FilePath.1=/etc/, 3S.dat IecFilePath.1=/proc/, cpuinfo IecFilePath.2=/proc/, iomem PlaceholderFilePath.1=/sys/devices/w1_bus_master1, $OneWire$ PlcLogicPrefix=1 ; ; ---------------------- ; selbst eingefügt PlaceholderFilePath.2=/home/root, $my_home_root$ PlaceholderFilePath.3=/etc/init.d, $my_conf$ PlaceholderFilePath.4=/var/lib/mpd, $my_music$ PlaceholderFilePath.5=/root/Rasp_SPS_Filesystem, $my_Rasp$ Ob die Einträge sich etwas überlappen, kann mir gern jemand sagen, das ist aber nicht das Problem. Ich habe bei den vielen Versuchen, das Teil zum Laufen zu bringen, bemerkt, daß die Einträge auch ganz schnell mal verschwinden. Das ist ja auch so beschrieben, wenn die nächste Version kommt, sind meine Einträge weg. Da ich ähnliche Probleme mit dem Funktionieren von "SysProcessExecuteCommand2()" hatte, die ich ebenfalls mit Einträgen in die /etc/CODESYSControl.cfg hätte beheben können, habe ich gelesen, das man "private" Einträge lieber in die Datei /etc/CODESYSControl_User.cfg machen soll. Gesagt getan und "SysProcessExecuteCommand2()" lief: [SysProcess] Command=AllowAll Command.0=shutdown Aber auch irgendwo stand, das so ein Beteichner wie [SysFile] oder [SysProcess] nur einmal in den beiden Files /etc/CODESYSControl.cfg oder(!) /etc/CODESYSControl_User.cfg vorkommen darf. Das ist nun die eigentliche Frage! Ist das so ? Bei [SysProcess] ist das kein Problem, das gibt es in /etc/CODESYSControl.cfg nicht. Aber bei [SysFile] sieht das anders aus. Da sind 5 Zeilen schon in /etc/CODESYSControl.cfg drin. Würde ich diese in die User-Datei rüberschieben, könnte beim nächsten Update was fehlen oder, oder... Lasse ich es so wie es ist, sind meine Einträge beim Update weg - das sollte ja verhindert werden. Kann da jemand genaue Auskunft geben ?? Vielen Dank Thomas
Last updated: 2024-06-28
Post by thommy54 on Raspi-Cam: CameraStream.project nicht zum Laufen zu bringen
CODESYS Forge
talk
(Post)
Hallo, Ich bringe das CameraStream.project nicht zum Laufen. Ich sehe die Ursache darin, das das Beispielprogramm sehr sparsam mit Programm-Kommentaren umgeht (von der Hilfe gar nicht zu reden). Ich habe beide Varianten bei der zu ändernden Zielvariable getestet: //copy video.htm to the webserver; //the location of the webserver depends on the used Apache version as mentioned in online help hDirHtmlTest:=SysDirOpen( szDir:='/var/www', pDirInfo:= ADR(dirInfo), diMaxDirEntry:=iMaxDirEntry, szDirEntry:=szDirEntry, pResult:=ADR(iDirHtmlError)); IF (iDirHtmlError = 0) THEN SysDirClose(hDir:=hDirHtmlTest); SysFileCopy('/var/www/video.htm', '$$PlcLogic$$/Application/video.htm', ADR(dwCopySize)); ELSE .... als auch hDirHtmlTest:=SysDirOpen( szDir:='/var/www/html', pDirInfo:= ADR(dirInfo), diMaxDirEntry:=iMaxDirEntry, szDirEntry:=szDirEntry, pResult:=ADR(iDirHtmlError)); IF (iDirHtmlError = 0) THEN SysDirClose(hDir:=hDirHtmlTest); SysFileCopy('/var/www/html/video.htm', '$$PlcLogic$$/Application/video.htm', ADR(dwCopySize)); ELSE .... Die Url-Streams habe ich gelassen wie sie vorgegeben waren: urlStream := CONCAT('http://', CONCAT(sIPAddress, '/video.htm')); urlPicture := CONCAT('http://', CONCAT(sIPAddress, '/cam_pic.php')); In der Webvisu im Browser komme ich maximal dahin wie im Screeshot Video_Visu_1 zu sehen. Also scheint der Link zu video.htm zu klappen. Das der zu cam_pic.php nicht klappt, wundert mich nicht, denn es existiert nicht und wird auch nicht evtl. am rechten Ort angelegt. Ich bin mir vollkommen im Unklaren: muss da was auf dem Raspberry Pi im Hintergrund laufen , z.B. raspivid . Welcher Programmteil bedient die Cam ? Ich erkenne auch nicht, wo ein einzelnes picture entstehen soll. Wäre dankbar, wenn ich hier etwas Hilfe bekommen könnte. Evtl. gibt es Probleme mit der von mir verwendeten Codesys-Version 3.5.20.1 ? Ich benutze einen Raspberry 4 Rev.1.2. Grüße Thomas
Last updated: 2024-07-04
Post by vstrom on Codesys v3.5.22.10 - Internal error:System.AggregateException...Value cannot be null...Parameter name: expLValue
CODESYS Forge
talk
(Post)
Hi to all, I receive an error when I try to compile a project that in v.3.5.21.50 have no problem. The error seems to comes out when I add the Visualization part into the project. The complete error is: [ERROR] Internal error:System.AggregateException: One or more errors occurred. ---> System.Exception: Internal error in Code ---> System.ArgumentNullException: Value cannot be null. Parameter name: expLValue at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentExpression(IExprementPosition pos, IExpression expLValue, IExpression expRValue, Operator kindof) at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentStatement(IExprementPosition pos, IExpression expLeft, IExpression expRight) at ..(IExpression , IExpression ) at ..(_IAssignmentExpression , ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.AssignmentStatementReplacer.ReplaceExpressionStatement(_IExpressionStatement expressionStatement, _ICompiledPOU cpou) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IForStatement forloop) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at ..(_ICompiledPOU ) at ..(_ICompiledPOU ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) at ..(_ICompiledPOU ) at ..(_ICompiledPOU& ) at ..() --- End of inner exception stack trace --- --- End of inner exception stack trace --- at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhase5_Codegenerator.(IList1 ) at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhase5_Codegenerator.(IScope5 , IList1 ) at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhase5_Codegenerator.(ICodegenerator ) at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhaseControllerGenerateCode.() at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhaseControllerGenerateCode.() ---> (Inner Exception #0) System.Exception: Internal error in Code ---> System.ArgumentNullException: Value cannot be null. Parameter name: expLValue at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentExpression(IExprementPosition pos, IExpression expLValue, IExpression expRValue, Operator kindof) at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentStatement(IExprementPosition pos, IExpression expLeft, IExpression expRight) at ..(IExpression , IExpression ) at ..(_IAssignmentExpression , ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.AssignmentStatementReplacer.ReplaceExpressionStatement(_IExpressionStatement expressionStatement, _ICompiledPOU cpou) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IForStatement forloop) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at ..(_ICompiledPOU ) at ..(_ICompiledPOU ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) at ..(_ICompiledPOU ) at ..(_ICompiledPOU& ) at ..() --- End of inner exception stack trace ---<---
Last updated: 2026-04-22
Post by wold on CodeMeter Network Server: Keep runtime dongle local-only and export only a second CmStick
CODESYS Forge
talk
(Post)
Hello, I am running a CODESYS Control Runtime on a Raspberry Pi. Two CmSticks are connected to the same system: CmStick A - Runtime license - MultiCore license - KNX license CmStick B - Engineering / Developer licenses My goal is: The runtime on the Raspberry Pi shall use CmStick A locally. Licenses from CmStick A shall NOT be provided by the CodeMeter Network Server. Only licenses from CmStick B shall be available to remote network clients. During troubleshooting I observed that the CodeMeter Network Server collects licenses from both CmSticks. The KNX license appears to be local-only, but the runtime and multicore licenses of the same dongle are still visible through the server. I would like to know if a supported configuration exists for the following scenario: One CmStick remains strictly local to the runtime. A second CmStick on the same machine is exported through the CodeMeter Network Server. Questions: Is it possible to exclude a specific CmStick from being exported by the CodeMeter Network Server? Can this be configured via License Access Permissions (ACL), WebAdmin, or another mechanism? Can export rules be applied per CmStick, per Firm Code, or per Product Code? If supported, could you provide a configuration example or a reference to the relevant documentation? The reason for asking is that after removing a separately installed CodeMeter server component and returning to a local-only setup, the runtime licensing behaviour became stable again. Therefore I am looking for the officially supported way to keep the runtime dongle local while still providing engineering licenses from a second dongle over the network. Thank you.
Last updated: 2026-08-02
Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
Here is the output Codesyscontrol.log ;**************************************************************** ;<loggername>/tmp/codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>1000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;**************************************************************** 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <logoptions> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <bEnable>1</bEnable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <type>normal</type> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <timestamp>rtc</timestamp> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <Filter>0x0000000f</Filter> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxEntries>1000</MaxEntries> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFiles>1</MaxFiles> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFileSize>1000000</MaxFileSize> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, </logoptions> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, CODESYS Control for PFC200 SL 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 6, <version>3.5.16.40</version> <builddate>Mar 2 2021</builddate> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 5, Copyright (c) 3S - Smart Software Solutions GmbH 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKbus</cmp>, <id>0x0000008a</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPfcx00</cmp>, <id>0x00000088</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.16.0</ver> 2023-09-12T21:12:16Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>192.168.1.17</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 4</interface> at router <instance>0</instance> registered 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 2, Running as network server 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 1, Running as network client 2023-09-12T21:12:16Z, 0x0000000a, 1, 0, 0, <NumOfChannels>4</NumOfChannels> channels available, each of the size <BufferSize>100000</BufferSize> Bytes 2023-09-12T21:12:16Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2023-09-12T21:12:16Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2023-09-12T21:12:16Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>192.168.1.17</ipaddress> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>2</instance> registered 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Hostname: PFC200, Port: 4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, URL: opc.tcp://PFC200:4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CODESYS_DefaultProvider with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CmpOPCUAProviderIecVarAccess with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:17Z, 0x00000126, 1, 0, 0, Valid license found for OPC UA IecVarAccess provider. 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 7, Retains matched to bootproject of application [<app>Application</app>] 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 6, Bootproject of application [<app>Application</app>] loaded 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to <address>(0011)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 16, 8, Network interface for mainnet=<mainnet>ether 5</mainnet> not found 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to <address>(0000)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>2</instance> address to <address>(2ddc:c0a8:0111)</address> 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 10, Application [<app>Application</app>] started 2023-09-12T21:12:17Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2023-09-12T21:13:37Z, 0x00000001, 1, 0, 0, runtime licensed 2023-09-12T21:17:17Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Channel timeout (<curtime>16012264</curtime>, <lasttime>15982259</lasttime>) 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Closing connection to <address>0329:032e</address> 2023-09-23T14:46:00Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-23T14:48:57Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange]
Last updated: 2023-09-27
Post by jonasz on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
Hi, I'll link to the topic not wanting to start a new one. In the application I am building, I wanted to use the diagnostics described in the CAA Device Diagnosis library. In principle, everything is ok, except for the elements related to ModbusTCP. Despite the fact that ModbusTCP is taken into account in the documentation, it is not recognised via the interfaces. FUNCTION_BLOCK NET_HW_DIAG VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR (* Referencja do struktury z danymi dla HMI ASTRAADA.*) Visu: REFERENCE TO VISU; (* Wskaźnik na mastera EtherCAT.*) pEtherCATMaster : POINTER TO IoDrvEtherCAT; (* Wskaźnik na slave EtherCAT.*) pEtherCATSlave : POINTER TO EtcSlave; (* Interfejs dla węzła w drzewie urządzeń.*) _itfNode: DED.INode; (* Ogólny interfejs magistrali. Zapewnia podstawowe informacje o magistrali polowej.*) _itfBus: DED.IBus; (* Interfejs urządzenia. Zapewnia rozszerzone informacje o urządzeniu (magistralowym).*) _itfDevice2: DED.IDevice2; (* Ogólny interfejs magistrali. Zapewnia podstawowe informacje o magistrali polowej.*) _itfStack: DED.IStack; (* Numer węzła w drzewie urządzeń.*) uiNodes: UINT; (* Operator jest rozszerzeniem normy IEC 61131-3. W czasie wykonywania operator wykonuje konwersję typu odwołania do interfejsu na inny typ. Operator zwraca wynik BOOL. Wartość TRUE oznacza, że CODESYS pomyślnie wykonał konwersję. *) xQueryResultBus: BOOL; xQueryResultDevice2: BOOL; xQueryResultStack: BOOL; (* Struktura danych dotyczących węzłów w drzewie urządzeń.*) NetHwDiag: NW_HW_STAT; ModbusTcpClientDeviceInfo: IoDrvModbusTCP.DED.DEVICE_INFO; ModbusTcpClientDeviceState: IoDrvModbusTCP.DED.DEVICE_STATE; ModbusTcpDeviceInfo: IoDrvModbusTCP.DED.DEVICE_INFO; ModbusTcpDeviceState: IoDrvModbusTCP.DED.DEVICE_STATE; END_VAR (* Pobranie wskaźników dla pierwszego mastera i pierwszego slave w sieci EtherCAT.*) pEtherCATMaster := g_pFirstMaster; pEtherCATSlave := pEtherCATMaster^.FirstSlave; (* Diagnostyka sieci EtherCAT.*) pEtherCATMaster := g_pFirstMaster; pEtherCATSlave := pEtherCATMaster^.FirstSlave; NetHwDiag.xConfigFinished := pEtherCATMaster^.xConfigFinished; NetHwDiag.xDistributedClockInSync := pEtherCATMaster^.xDistributedClockInSync; NetHwDiag.xError := pEtherCATMaster^.xError; NetHwDiag.xSyncInWindow := pEtherCATMaster^.xSyncInWindow; NetHwDiag.sLastMessage := pEtherCATMaster^.LastMessage; NetHwDiag.LastError := pEtherCATMaster^.LastError; (* Diagnostyka drzewa urządzeń.*) uiNodes := 0; _itfNode := DED.GetRoot(); REPEAT NetHwDiag.asDeviceName[uiNodes] := DED.GetDeviceNameString(itfNode := _itfNode); xQueryResultBus := __QUERYINTERFACE(_itfNode,_itfBus); IF xQueryResultBus THEN _itfBus.GetBusInfo(buiInfo := NetHwDiag.aBusInfo[uiNodes]); NetHwDiag.aBusState[uiNodes] := _itfBus.GetBusState(); END_IF xQueryResultDevice2 := __QUERYINTERFACE(_itfNode,_itfDevice2); IF xQueryResultDevice2 THEN _itfDevice2.GetDeviceInfo(deiInfo := NetHwDiag.aDeviceInfo[uiNodes]); NetHwDiag.aDeviceState[uiNodes] := _itfDevice2.GetDeviceState(); IF pEtherCATSlave <>0 THEN pEtherCATSlave^(); IF pEtherCATSlave^.SlaveAddr = NetHwDiag.aDeviceInfo[uiNodes].idSystem THEN NetHwDiag.aAlStatus[uiNodes] := pEtherCATSlave^.ALStatus; pEtherCATSlave := pEtherCATSlave^.NextInstance; END_IF END_IF ELSE xQueryResultStack := __QUERYINTERFACE(_itfNode,_itfStack); IF xQueryResultStack THEN _itfStack.GetDeviceInfo(deiInfo := NetHwDiag.aDeviceInfo[uiNodes]); NetHwDiag.aDeviceState[uiNodes] := _itfStack.GetDeviceState(); END_IF END_IF uiNodes := uiNodes + 1; _itfNode := DED.GetNextNode(_itfNode); UNTIL _itfNode = 0 END_REPEAT (* Diagnostyka Modbus.*) Modbus_TCP_Client.GetDeviceInfo(deiInfo := ModbusTcpClientDeviceInfo); ModbusTcpClientDeviceState := Modbus_TCP_Client.GetDeviceState(); PAC_3200T.GetDeviceInfo(deiInfo := ModbusTcpDeviceInfo); ModbusTcpDeviceState := PAC_3200T.GetDeviceState(); Of course, you can take the easy way out and refer directly to the devices, but I wanted a reusable component. Any constructive help is very welcome Best regards Jonasz
Last updated: 2025-07-15
Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon
CODESYS Forge
talk
(Post)
I had this code working in a previous version of CoDeSys to read variables from a GVL that were added to the Symbol configuration. The problem now is that when I get the _IBaseTreeNode_Parent, it returns a valid interface, but none of the methods or properties work. If you monitor the _IBaseTreeNode in the watch window, it does show the correct child count. However, it fails at step 30, where the child count incorrectly returns zero. In the image, you can see that the watch window displays the correct value that the property should return. Attached is the full project code. FUNCTION_BLOCK Symbols_TO_STR VAR_INPUT i_sPath : STRING(255); i_diIndexChild : DINT; i_diIndexComponent : DINT; END_VAR VAR_OUTPUT q_diChildCount : DINT; q_diComponentCount : DINT; q_sName : STRING(255); q_sValue : STRING(255); q_sType : STRING(80); q_sErrorResult : STRING(80); END_VAR VAR uiStepCopy : UINT; uiStep : UINT; uiStepProcessCopy : UINT; uiStepProcess : UINT; _IBase : IecVarAccessLibrary.IBase; _pIIecVarAccess5 : POINTER TO IecVarAccessLibrary.IIecVarAccess5; _IIecVarAccess5 : IecVarAccessLibrary.IIecVarAccess5; _RTS_IEC_RESULT : IecVarAccessLibrary.RTS_IEC_RESULT; _udiResult : UDINT; _VariableInformationStruct : IecVarAccessLibrary.VariableInformationStruct; _IBaseTreeNode_Parent : IecVarAccessLibrary.IBaseTreeNode; _IBaseTreeNode_Child : IecVarAccessLibrary.IBaseTreeNode; _ITypeDesc_Child : IecVarAccessLibrary.ITypeDesc; _TypeDescAsUnion_Child : IecVarAccessLibrary.TypeDescAsUnion; _arIBaseTreeNode_Child : ARRAY[0..20] OF IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Child : IecVarAccessLibrary.IBaseLibrary.TypeClass; _psSymbolName_Child : POINTER TO STRING; _sSymbolName_Child : STRING(255); _IBaseTreeNode_Component : REFERENCE TO IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Component : IecVarAccessLibrary.IBaseLibrary.TypeClass; _ByteAddress_Component : __XWORD; _ByteOffset_Component : __XWORD; _sArrayIndexName_Component : STRING(20); _diArrayIndexCalc_Component : DINT; _diArrayIndexValue_Component: DINT; _psSymbolName_Component : POINTER TO STRING; _sSymbolName_Component : STRING(255); END_VAR uiStepCopy:=uiStep; uiStepProcessCopy:=uiStepProcess; CASE uiStep OF 10: // GET IBASE FROM CURRENT APP _IBase:= IecVarAccessLibrary.IecVarAccGetFirstInterface2(0); IF _IBase<>0 THEN uiStep:=20; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IecVarAccGetFirstInterface2'); uiStep:=9000; END_IF 20: //QueryInterface IIecVarAccess5 from IBASE _pIIecVarAccess5 := _IBase.QueryInterface(IecVarAccessLibrary.ITFID_IIecVarAccess5, ADR(_RTS_IEC_RESULT)); IF _pIIecVarAccess5<>0 AND _RTS_IEC_RESULT=0 THEN _IIecVarAccess5 := _pIIecVarAccess5^; uiStep:=30; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': QueryInterface_IIecVarAccess5'); uiStep:=9000; END_IF 30: // Get IBaseTreeNode_Parent _IBaseTreeNode_Parent := _IIecVarAccess5.VarAccGetNode3(ADR(i_sPath), ADR(_VariableInformationStruct), ADR(_RTS_IEC_RESULT)); IF _IBaseTreeNode_Parent<>0 AND _RTS_IEC_RESULT=0 THEN q_diChildCount:=_IBaseTreeNode_Parent.ChildCount; uiStep:=40; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF 40: // Get IBaseTreeNod_Child IF(q_diChildCount-1>=i_diIndexChild AND i_diIndexChild >=0) THEN _IBaseTreeNode_Child := _IBaseTreeNode_Parent.GetChild(i_diIndexChild); IF _IBaseTreeNode_Child<>0 THEN uiStep:=50; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': i_diIndexChild OutBounds'); uiStep:=9000; END_IF
Last updated: 2025-08-20
Post by denizerm on Deploy Control SL cant find Podman
CODESYS Forge
talk
(Post)
Hello, CODESYS seems to have problems finding the container engine. In the "Deploy Control SL" window, after connecting via ssh, it simply says: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.4.199) [WARNING] Error detecting container architecture running podman info yields normal results. My podman info output is as follows: home/Admin$ podman info host: arch: amd64 buildahVersion: 1.35.3 cgroupControllers: - cpu - memory - pids cgroupManager: systemd cgroupVersion: v2 conmon: package: Unknown path: /usr/bin/conmon version: 'conmon version 2.1.10, commit: affab49967eb62f75d2a47398344ab053326289f' cpuUtilization: idlePercent: 99.36 systemPercent: 0.3 userPercent: 0.34 cpus: 4 databaseBackend: sqlite distribution: codename: scarthgap distribution: redagv version: 1.0.0 eventLogger: journald freeLocks: 2040 hostname: secure-automation-os idMappings: gidmap: - container_id: 0 host_id: 1000 size: 1 - container_id: 1 host_id: 100000 size: 65536 uidmap: - container_id: 0 host_id: 1100 size: 1 - container_id: 1 host_id: 100000 size: 65536 kernel: 6.6.65-intel-pk-standard linkmode: dynamic logDriver: journald memFree: 6115598336 memTotal: 8086278144 networkBackend: cni networkBackendInfo: backend: cni dns: {} ociRuntime: name: crun package: Unknown path: /usr/bin/crun version: |- crun version 1.14.3.0.0.0.8-89d44-dirty commit: 89d44467e3b410b73f2065756a12789be45b855b rundir: /run/user/1100/crun spec: 1.0.0 +SYSTEMD +SELINUX +APPARMOR +CAP +SECCOMP +EBPF +YAJL os: linux pasta: executable: /usr/bin/pasta package: Unknown version: "" remoteSocket: exists: true path: /run/podman-shared/podman.sock security: apparmorEnabled: false capabilities: CAP_CHOWN,CAP_DAC_OVERRIDE,CAP_FOWNER,CAP_FSETID,CAP_KILL,CAP_NET_BIND_SERVICE,CAP_SETFCAP,CAP_SETGID,CAP_SETPCAP,CAP_SETUID,CAP_SYS_CHROOT rootless: true seccompEnabled: true seccompProfilePath: "" selinuxEnabled: false serviceIsRemote: true slirp4netns: executable: /usr/bin/slirp4netns package: Unknown version: |- slirp4netns version 1.2.0-beta.0+dev commit: unknown libslirp: 4.7.0 SLIRP_CONFIG_VERSION_MAX: 4 libseccomp: 2.5.5 swapFree: 0 swapTotal: 0 uptime: 1h 36m 10.00s (Approximately 0.04 days) variant: "" plugins: authorization: null log: - k8s-file - none - passthrough - journald network: - bridge - macvlan - ipvlan volume: - local registries: localhost:5000: Blocked: false Insecure: true Location: localhost:5000 MirrorByDigestOnly: false Mirrors: null Prefix: localhost:5000 PullFromMirror: "" search: - localhost store: configFile: /home/serviceuser/.config/containers/storage.conf containerStore: number: 2 paused: 0 running: 2 stopped: 0 graphDriverName: overlay graphOptions: {} graphRoot: /data/containerfiles graphRootAllocated: 119952025600 graphRootUsed: 13801246720 graphStatus: Backing Filesystem: extfs Native Overlay Diff: "true" Supports d_type: "true" Supports shifting: "false" Supports volatile: "true" Using metacopy: "false" imageCopyTmpDir: /var/tmp imageStore: number: 4 runRoot: /run/user/1100/containers transientStore: false volumePath: /data/containerfiles/volumes version: APIVersion: 5.0.2-dev Built: 1711987427 BuiltTime: Mon Apr 1 16:03:47 2024 GitCommit: bb81e85a430fa95d23a15b77c717fd68bf06ebf2 GoVersion: go1.22.12 Os: linux
Last updated: 2025-10-22
Post by hyplcmotion on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
CODESYS Forge
talk
(Post)
Hello, I’m encountering the same issue. I only receive these errors when downloading to the PLC—there are no errors during the build—after upgrading to CODESYS 3.5.21.10. Is there any known fix or recommended solution? Visualization seems running ok, no PLC log error. Visualization: Error: The element of type 'VisuFbLabel' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemImage' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemImage' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemButton' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemButton' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds.
Last updated: 2026-01-26
Post by ryusoup on JSONByteArrayWriter problem?
CODESYS Forge
talk
(Post)
Hello, I am trying to implement a FB to make JSON formatted WSTRING type message using JSON Utilities 1.9.0.0 included in the IIoT library. In my case, I want to set some objects or arrays and set values to them later. But when I wrote as the sample below, // init builder builder(pJsonData:=pJsonData, diRootObj=>diRootObj); // set the 1st key to root diKey1 := builder.SetKeyWithArray(wsKey:="key1", diParentIndex:=diRootObj, eError=>eError); // set a value to the 1st key wsValue:="value01"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set the 2nd key to root diKey2 := builder.SetKeyWithArray(wsKey:="key2", diParentIndex:=diRootObj, eError=>eError); // set a value to the 2nd key wsValue:="value02"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // set a value to the 1st key again wsValue:="value03"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set a value to the 2nd key again wsValue:="value04"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // write build result writer(xExecute:=TRUE, pwData:=ADR(wsResult), udiSize:=SIZEOF(wsResult), xAsyncMode:=FALSE, jsonData:=pJsonData^); the result was: { "key1": ["value01"], "key2": ["value02", "value03", "value04"] } while my expection was: { "key1": ["value01", "value03"], "key2": ["value02", "value04"] } Inspecting pJsonData^, JSONData itself seems to be ok, so I believe the issue is something caused by the writer FB. Does anyone know how to fix it? Thanks,