Post by eschwellinger on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
Please check the jitter in the online taskmonitoring. cylce time of the motion task and jitter in case of the error.
Last updated: 2025-12-29
WebVisu scaling regression in V3.5.22 P2: frame size jumps when switching visualizations
CODESYS Forge
talk
(Thread)
WebVisu scaling regression in V3.5.22 P2: frame size jumps when switching visualizations
Last updated: 2026-06-15
How to get the instance of a CANopen Master in the Device Tree?
CODESYS Forge
talk
(Thread)
How to get the instance of a CANopen Master in the Device Tree?
Last updated: 2026-09-02
Post by eschwellinger on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
we need the Systeminformation in the Communication tap(logged in)
Last updated: 2026-02-17
_NEW when used with classes and interfaces. Interface shows "Hidden Instance" in watch.
CODESYS Forge
talk
(Thread)
_NEW when used with classes and interfaces. Interface shows "Hidden Instance" in watch.
Last updated: 2026-03-24
CODESYS Date/Time Picker in Dialog does not update value on close (focus issue) – any workaround?
CODESYS Forge
talk
(Thread)
CODESYS Date/Time Picker in Dialog does not update value on close (focus issue) – any workaround?
Last updated: 2026-05-21
branch_copy(checkout=True) liefert ungültigen Projekt-Handle (0) in CODESYS V3.5 SP22 Patch 3
CODESYS Forge
talk
(Thread)
branch_copy(checkout=True) liefert ungültigen Projekt-Handle (0) in CODESYS V3.5 SP22 Patch 3
Last updated: 2026-09-22
Post by alimans on Hex string
CODESYS Forge
talk
(Post)
Hi kdkwhite, for Word you still can use suggested code by using a union structure and crack down your Word to two byte as bellow: TYPE CrackWordToByte : UNION InWord : WORD; OutBytes : ARRAY [0..1] OF BYTE; END_UNION END_TYPE then define your variable as this type: udInput : CrackWordToByte; now assign your Word variable input to InWord and send OutBytes[x] to the mentioned method: udInput.InWord := WordVariableInput; Input := udInput.OutBytes[x]; Regarding your question about the code: actually 48 is ascii code of "0" and while 65 is the ascii code of "A" so in above code 55 + 10 would be 65.
Last updated: 2023-09-20
Post by fabian on Sys Process Execute Command
CODESYS Forge
talk
(Post)
Hello, I have a question: Once the command is being executed, is there a way to kill it again? As the called application is running in the background, the user can't close it but it shall be closed/terminated, commanded by codesys. I have tried with "SysProcessTerminate" but I guess this is not correct as the RTE crashes when this function is called. Starting the application: IF GVL.xStrtQR THEN GVL.xStrtQR := FALSE; SysProcess.SysProcessExecuteCommand2(pszCommand:=sCmd, pszStdOut:=stdout, udiStdOutLen:= SIZEOF(stdout),pResult := ADR(GVL.pResQRTsk)); END_IF Trying to stop it again: IF GVL.xTrmQR THEN GVL.xTrmQR := FALSE; pResTerm := SysProcess.SysProcessTerminate(hProcess:=SysProcess.SysProcessGetCurrentHandle(pResult:=ADR(GVL.pResQRTsk))); END_IF Codesyscontrol Win x64, 3.5.19.10. Many thanks for any advice pointing to the correct direction.. :-) Regards, Fabian
Last updated: 2023-11-17
Post by jegerjon on Testing of Codesys program
CODESYS Forge
talk
(Post)
I have a simulation function that toggle xSimActive. I map all IO variables to "IO GVLs" when xSimActive=0. I map IO corresponding SimIO GVL to "IO GVLs" when xSimActive=1. Then I write code for the simulation program that runs when xSimActive=1. Typically increase flow corresponding to pump speed, simulate tankfilling corresponding to flow and so on. I made a FC that require a correct code to activate simulation to avoid unintended activation by service dept. When comissioned remove any possibility to activate simulation. Super when officetesting and supporting service dept. + cheap as it requires no additional equipment, and it is easier to support customer later on in the life cycle as you can test proposed changes without setting up a testlab.
Last updated: 2023-12-07
Post by jegerjon on Testing of Codesys program
CODESYS Forge
talk
(Post)
I have a simulation function that toggle xSimActive. I map all IO variables to "IO GVLs" when xSimActive=0. I map IO corresponding SimIO GVL to "IO GVLs" when xSimActive=1. Then I write code for the simulation program that runs when xSimActive=1. Typically increase flow corresponding to pump speed, simulate tankfilling corresponding to flow and so on. I made a FC that require a correct code to activate simulation to avoid unintended activation by service dept. When comissioned remove any possibility to activate simulation. Super when officetesting and supporting service dept. + cheap as it requires no additional equipment, and it is easier to support customer later on in the life cycle as you can test proposed changes without setting up a testlab.
Last updated: 2023-12-07
Post by opineiro on Stack overflow with really simple function
CODESYS Forge
talk
(Post)
Hi, I have an issue with a function which sends a message through API Rest. I'm using a function from httpCLient library. I have tested this function inside a program and it works fine. But when I want to use it inside a function (so I can call it simultaneously from 2 different points on the main program) it gives a stack overflow error. In detail it says: "C0297 Stack Overflow on Main Task. Stack sizes... Call hierarchy:" I have simplified as much as I can the function, but I'm hitting a wall with this. Anybody has an idea of what's wrong? Thanks!
Last updated: 2024-09-16
Post by timvh on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
If you have a Windows system (RTE), then why not run the CODESYS HMI as separate controller. This could easily be moved to another PC if required. In the HMI you could also still use the Symbolic Var access as part of the Data Source Manager, although maybe OPC is the preferred way to make it more future proof. Or what about the Remote Target Visu. Then you can reduce the load of the main controller, while still only having to create one application including Visualization. This is now also supported for Linux systems. See: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_target_visu_for_linux.html https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_execute_remote_target_visu.html
Last updated: 2024-09-28
Post by pernockham on Linking to IO during runtime with hot swap?
CODESYS Forge
talk
(Post)
I have a project where a single PLC shall control multiple nodes (up to 10 units?) with IO connected through profinet. Ideally each node should be identical however with time I see situations were different setups/configurations will be used. Codesys PLC (GVLs) |Profinet | |--PNIO-node-1--| | | AIO, | | DIO, | | CNT etc. | |--PNIO-node-2--| | | AIO, | | DIO, | | CNT etc. Ideally I think of a configuration through yaml/xml-files (the assignment/linking of the profinet nodes towards GVL-variables in the PLC as well as scaling, channel configration etc.). Would be grateful if someone could suggest library/-ies that can handle the following: - Verify what IO is connected to a device/node. - Hot-swap/assign link for IO towards GVLs, either automatically or through a HMI.
Last updated: 2024-10-11
Post by trusty-squire on AXIS Rollover
CODESYS Forge
talk
(Post)
If you mean you want to shift the Origin or Zero position of your axis, you can try MC_SetPosition and set the position to 0 (if you want to take the current active position and make it the new 0. Adjust this number accordingly if/as needed). This means the servo drive keeps it's current origin position, and Codesys applies an offset to the servo drive position in the logic. You can also use the homing function of your servo drive using MC_Home and have your drive configured to set the current position as origin when it receives a homing command.
Last updated: 2025-03-11
Post by imdatatas on Programmatically change Tappet on a cam
CODESYS Forge
talk
(Post)
Yes, There is. As explained "Manual creation of CAM structure" on below section. Likewise tappet structure also can be create manual and value of the switching point can be change during IEC program running. https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_basic_cam_programmatic_creation.html Just create a cam table and define some tapped points as sample for your project. Then on project compile, the created cam tapped data is converted internally into a global variable list. By clicking "Display generated code" in the "cam editor", you can display the automatically created global variables for both cam & tappets. Regards, Imdat
Last updated: 2025-04-02
Post by viksym on How to get the motor scaling value from code
CODESYS Forge
talk
(Post)
Is there a way to see what value is set as the "Work travel distance per motor rotation" that is set in the Scaling menu of the axis ? I am working on my own homing function block for sensorless (hardstop) homing and I want to make it be universal between different axes with different motor's scaling for distance per rev so I need to know this value from the axis itself. I know I could do it by just creating an input variable for the function block but I'm leaving that option as a last resort.
Last updated: 2025-06-12
Post by pauloricardoss on Codesys Control Raspberry PI 4.10.0 - missing 'Update Raspberry PI' option
CODESYS Forge
talk
(Post)
I am having the same problem. 'Update Raspberry PI' disappeared from the 'Tools' menu. Using RaspberryPI 3B+, Codesys V3.5 Sp21 + RaspberryPI Package 4.16. I installed the package as Administrator, executed Codesys as Administrator I also tried to connect using the deploy (even with ssh and everything enabled on the RaspberryPi I received password denied). I used in the past the same equipment with Codesys V3.5 Sp18 and RaspberryPI Package 4.08, it was really easy. (I also did a brand new RaspbianOs installation to make sure that nothing affect the connection). Anyone, knows how to fix it? Thanks,
Last updated: 2025-06-13
Post by jeroen on Ramp function
CODESYS Forge
talk
(Post)
Hi, Found a nice ramp function in the OSCAT lib (FT_RMP), but is there a nice way to 'set' the output to the current input as form of a reset. The reason for this, is that I want to set up a ramp for a pressure control input that should have x Bar/sec linear rise input. The only option (or code it by hand) I found is this OSCAT FB. Any other options? Just need to increase a value by x Bar/sec from let's say 250Bar (as start) to end 1500Bar. The Oscat ramp will always start at 0 when enable is off (FT_RMP.Rmp := FALSE)
Last updated: 2024-01-09
Post by mwandy on Codesys Project Protection
CODESYS Forge
talk
(Post)
I'm having trouble finding clear answers on this. I'm looking for a way to make a Codesys project password protected so that if the project is distributed it can be used to log into a controller to view and debug logic. At this same time I want to prevent the project from being saved as well as edits being downloaded to the controller. Basically I want to make a whole project view-only. What is the beat way to achieve this? I have had minor success with access rights, which solves the problem with trying to login if the project doesn't match what is in the controller. However with this solution, edits can still be made and saved, possibly corrupting the core project, preventing future logins. Any suggestions?
Last updated: 2024-03-29
Post by danwoodlock on Rpi zero w lost license after 4.11 update
CODESYS Forge
talk
(Post)
Hello all, Encountered an issue with my zero which seems to have happened after the 4.11 update. It now runs in demo mode (2hr) and I am trying to see what the appropriate steps are prior to contacting codesys directly. Background: I recently did a fresh install of w11 on my pc, so it seems "c:\ProgramData\CODESYS\Licenses\" only has information related to my pi5, which I licensed just this past Friday. I have all my license documentation about my rpi zero as far as the emails received, but when I try to claim using the ticket number it says its already been used, or something to that effect, which it was. Currently trying to perform device license reader, which is taking some time.
Last updated: 2024-04-14
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
Hello, CODESYS Control is running on my RevPi, and my system communicates over a CANbus with a master using the ConnectCan module (Slave - CANopen Device). The communication works perfectly fine so far. However, as soon as I call a Python script with "SysProcessExecuteCommand2" that creates a CSV file and executes without errors, the master does not adopt any changes to the Transmission Process Data Objects (TPDOs). I don't quite understand what one has to do with the other, and perhaps someone can help me with this. Here is my script call: SysProcess.SysProcessExecuteCommand2(pszCommand:='python /home/pi/test.py', pszStdOut:=sCMDOutput, udiStdOutLen:= SIZEOF(sCMDOutput), pResult := ADR(eResult)); Thank you in advance! Best regards, Stefan
Last updated: 2024-06-20
Post by msegon on OPC UA Client failed to connect
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I'm trying to read data from Tridium Niagara 4.15 OPC UA Server, but I get the error BadCertificateInvalid. As far as I understand, you need to add a CA certificate somewhere to establish a secure connection, but I don't know where. 2025-10-27T09:06:43.247Z, 0x0000008d, 4, 0, 0, * ERROR: OpcUa_Channel_BeginConnect: Cannot create secure channel without certificates! 2025-10-27T09:06:43.247Z, 0x00001090, 4, 0, 0, * ERROR: Datasource: Error Failed (268468242) in state Connecting I tried communicating without encryption, but it doesn't find the point. Has anyone managed to establish encrypted OPC UA communication?
Last updated: 2025-10-28
Post by dvmaris on Control for Linux ARM64-User Management issue
CODESYS Forge
talk
(Post)
I'm trying to work with Codesys Control for Linux ARM64 SL 4.18.0.0 on a Toradex Verdin NXP iMX8MP. I have the runtime installed and operational as well as Codemeter lite 8.40.7141.503 (arm64). I'm running 3.5.20.60 and when "Scan Network" I see the Verdin popup. When I try to connect to it, the "mandatory use of the user management" popup shows...which makes sense. I click YES and enter user information and click OK. It immediately displays a "No device is responding to the scan request" popup. The IDE can see the Verdin in the scan...so this popup does not make sense to me. I thought maybe it was a read only issue but I've made all partitions and paths RW. Has anyone experienced this? Can anyone tell me where it is trying to write user data?
Last updated: 2026-02-11