Post by madskaizer on Task Priority Documentation?
CODESYS Forge
talk
(Post)
Hi All I was watching the Wago PFC300 webinar ( https://www.wago.com/global/lp-thank-you-onlineseminar-pfc-300 ), and the presenters comment about priority 1 being way above the Ethernet task priority, so that a priority 1 PLC program can actually loose SCADA connection, made me try to round up some hard evidence on Codesys Priorities. I find there is very little information on "correct" task priority configuration. There is a lot of different hardware manufacturers, using Codesys Runtime, that has different descriptions in their manuals on how to set up priority. https://doku.amk-motion.com/en/Subsystems/PDK_202975_A-Serie_en/Content/Projekt/AMKAMAC/PDK_202975_A4-A5_Produktbeschreibung/Funktionalitaet/PLC-Programming/PLC%20Tasks.htm?TocPath=PLC-Programming%7C_____7 https://product-help.schneider-electric.com/Machine%20Expert/V1.1/en/SoMProg/index.htm?#t=SoMProg%2FTask_Editor%2FTask_Editor-7.htm&rhsearch=priority&rhhlterm=priority&rhsyns=%20&SUBSTRSRCH=1 https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_f_task_configuration.html So my questions :) 1) If there is only 1 PLC_PRG task, does priority matter? 2) What is the priority of Ethernet / communication, if nothing is entered? 3) What is the priority of Codesys OPC UA server? 4) Some users here on forge mentions that Wago PLC programs should run as priority 11, but where does this recommendation origin from? 5) What are you recommendations for a relatively slow process, like building automation? It uses OPC UA for communication to SCADA, maybe some MODBUS-RTU and MODBUS-TCP, usually around 100 I/O, been running with everything in a single task at priority 1, 50-100ms cycle time. Some controllers have separate MODBUS tasks, but doesn't seem like a big difference. How would you recommend splitting up communication, IO fieldbus and programs into differently prioritized tasks? I know its a complex matter and all about my application, but I really miss there was just some kind of guidance in the documentations and with all new standard Codesys programs having priority 1 as default, makes it seem less important, than it really is.
Last updated: 2025-08-11
Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4
CODESYS Forge
talk
(Post)
Hi, I wanted to use the Adafruit Hat for the Raspberry and get acquainted with Softmotion using servos for RC models. This did work great with Codesys 3.5.19 Patch 1, but with Patch 4 and 5 i get errors. I suspect changes in the SoftMotion library have broken dependencies in the legacy drivers, might that be true? Thanks for any hint, spiessli Here the error log: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-19
Post by davidbo on Clean old license into an image SD
CODESYS Forge
talk
(Post)
That might not be enough using CODESYS V3.5 SP20 and CODESYS Control for Raspberry Pi MC SL version: 4.11 I deleted .cmact_license directory. I installed new license and the dialog box said it was done successfully, but in reality it was not. What more should be deleted 5:/var/opt/codesys$ ls -la total 1948 drwxr-xr-x 10 root root 4096 Nov 17 12:29 . drwxr-xr-x 5 root root 4096 Jul 30 2020 .. -rw-r--r-- 1 root root 100014 Nov 17 12:08 .Audit_0.log -rw-r--r-- 1 root root 100040 Nov 17 11:30 .Audit_1.log -rw-r--r-- 1 root root 100062 Nov 17 09:18 .Audit_2.log -rw-r--r-- 1 root root 66260 Nov 17 12:36 .Audit.log drwxr-xr-x 2 root root 4096 Mar 30 2020 backup -rw-r--r-- 1 root root 2640 Feb 22 2024 bacstac.ini drwxr-xr-x 4 root root 4096 Mar 30 2020 cert drwxr-xr-x 2 root root 4096 Nov 17 12:29 .cmact_licenses drwxr-xr-x 2 root root 4096 Mar 30 2020 _cnc -rw-r--r-- 1 root root 1000088 Nov 17 08:35 codesyscontrol_0.log -rw-r--r-- 1 root root 422521 Nov 17 12:30 codesyscontrol.log -rw-r--r-- 1 root root 355 Nov 17 12:29 .GroupDatabase.csv -rw-r--r-- 1 root root 355 Nov 17 12:19 .GroupDatabase.csv_ drwxr-xr-x 3 root root 4096 Nov 17 11:16 OPCUAServer drwxr-xr-x 6 root root 4096 Mar 30 2020 .pki drwxr-xr-x 9 root root 4096 Nov 17 11:16 PlcLogic -rwxr-xr-x 1 root root 156 Mar 30 2020 rts_set_baud.sh -rw-r--r-- 1 root root 20736 Feb 22 2024 .SoftContainer_CmEmbedded.wbb -rw-r--r-- 1 root root 12445 Nov 17 09:06 SysFileMap.cfg -rw-r--r-- 1 root root 1983 Feb 22 2024 .UFC_SoftContainer_CmEmbedded.WibuC mLif -rw-r--r-- 1 root root 646 Nov 17 09:51 .UserDatabase.csv -rw-r--r-- 1 root root 646 Nov 17 09:51 .UserDatabase.csv_ -rw-r--r-- 1 root root 17305 Nov 17 12:29 .UserMgmtRightsDB.csv drwxr-xr-x 2 root root 4096 Mar 30 2020 visu -rw-r--r-- 1 root root 32684 Feb 8 2023 WibuCtxt.ctx
Last updated: 2025-11-17
Post by alexgooi on Modbus TCP interface get stuck
CODESYS Forge
talk
(Post)
Dear Forum, I'm currently experimenting with Modbus interfaces in combination with a virtual controller. I have the following setup (Modbus_Setup.png): I have an IPC with Debian installed on it (Debian 13). On this Debian machine I have installed a docker server and on this docker server a Codesys runtime container is deployed (Codesys_image.png). The Modbus scanner makes connection with and IO coupler and this works well. But when I physically disconnect the ethernet connection between the IPC and the IO coupler the Modbus interface gets stuck in a state where it gets stuck in the busy state (Modbus_Stuck.png). When I plug the cable back in, the IO coupler isn't communicating until the xBusy variable is manually set to False, after this action is performed the communication goes back to normal. I have tried to set the container network to host and bridge (Network.png), but both version gives the same result (stuck scanner). I would expect that the Modbus interface is generating a timeout after 1 sec, because this is how it is setup (Modbus_settings.png), but this is not what happens. I have thought to write a piece of code that writes xBusy to false when it is stuck but because it is an output I'm not able to write to it. I have tried this with another PC (different CPU/motherboard) but this gives the same outcome. I tried updating to the latest version of Virtual control (4.20) but this gives the same result. I also tried to do the same thing with an ethernet IP scanner, and this gives an error after the timeout is expired (so this works well). I have tried to connect to the IO coupler using the Modbus_FB lib (Modbus_FB.png) the FB's are giving the correct errors and behaving as expected. At last I have tried to use a Scanner on a Codesys controller (no IPC) and here the scanner behaves as expected (an alarm is triggered after the timeout has been expired). The version of the Codesys components are listed in the picture Versions.png Is there anyone that can give me a push in the right direction? Kind regards Alex
Last updated: 2026-04-14
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.