Search talk: unknown

 

Unknown type error CODESYS Forge talk (Thread)
Unknown type error
Last updated: 2021-05-11

Unknown type CODESYS Forge talk (Thread)
Unknown type
Last updated: 2020-04-02

Unknown type:“CAA.HANDLE" CODESYS Forge talk (Thread)
Unknown type:“CAA.HANDLE"
Last updated: 2013-04-19

Unknown Sintax error CODESYS Forge talk (Thread)
Unknown Sintax error
Last updated: 2021-12-23

DNS unknown RealStationName CODESYS Forge talk (Thread)
DNS unknown RealStationName
Last updated: 2017-03-06

Unknown type CODESYS Forge talk (Thread)
Unknown type
Last updated: 2020-04-09

C0077: Unknown type: 'NULL' CODESYS Forge talk (Thread)
C0077: Unknown type: 'NULL'
Last updated: 2024-11-05

Canopen connection. Unknown node id. CODESYS Forge talk (Thread)
Canopen connection. Unknown node id.
Last updated: 2023-09-25

Ssytem overload für Task "Unknown" CODESYS Forge talk (Thread)
Ssytem overload für Task "Unknown"
Last updated: 2008-02-14

Ethernet IP New Device unknown settings CODESYS Forge talk (Thread)
Ethernet IP New Device unknown settings
Last updated: 2018-10-15

Declare and dereference pointer of unknown type CODESYS Forge talk (Thread)
Declare and dereference pointer of unknown type
Last updated: 2016-10-12

runtime error #20, task=unknown. Shed any light? CODESYS Forge talk (Thread)
runtime error #20, task=unknown. Shed any light?
Last updated: 2023-06-30

Cannot convert type 'Unknown type: 'ADR(tabOrderIdArray)" to type 'POINTER TO ARRAY [0..0]OF INT' CODESYS Forge talk (Thread)
Cannot convert type 'Unknown type: 'ADR(tabOrderIdArray)" to type 'POINTER TO ARRAY [0..0]OF INT'
Last updated: 2021-04-26

Function block with an array of unknown size as a VAR_IN_OUT CODESYS Forge talk (Thread)
Function block with an array of unknown size as a VAR_IN_OUT
Last updated: 2017-03-07

Post by dkugler on Text List Fallback Value CODESYS Forge talk (Post)
why you adding this ' ' ? you don't need them in the text field :-) delete them, write only Unknown and everything will be as expected
Last updated: 2024-04-18

Post by wbj0t on tool 'update raspberry pi' unavailable CODESYS Forge talk (Post)
Hi all. Codesys 3.5.19, patch 3. After installing raspberry 4.10 package I can see raspberry device, but can't see update raspberry pi tool. In custimsation->tools I found: Unknown command (8ec1a...) [plugin unavailable] Unknown command (7216f...) [plugin unavailable] Codesys installed in default directory. I reinstalled Codesys, thats not help.
Last updated: 2024-09-26

Post by phoward131 on Text List Fallback Value CODESYS Forge talk (Post)
I am relatively new to Codesys and I'm trying to develop an HMI that displays what mode a particular device is in based on an integer value. I am currently using dynamic texts with a text list which works fine but I am looking for a way to display a particular string (ie 'Unknown') when the index doesn't match any of of the indices in the text list. I can enter 'Unknown' in the text property of the text field element which works as expected but it displays the single quotes on the visualization. How can I escape these quotes to simply display the word Unknown? Thanks!
Last updated: 2024-03-22

Post by docker on Canopen connection. Unknown node id. CODESYS Forge talk (Post)
hi, i am currently trying to adapt an i/o device for a project. the node id is unknown and there is no eds file available. no data is being emitted from the device as a giveaway, the baudrate is known but useless without the node id. is there an sdo request available to determine the id? i cannot get the device to leave pre op status even with a global nmt request. please help. no hair left.
Last updated: 2023-09-25

Post by ellcap on Did a library update and now can't open project CODESYS Forge talk (Post)
EDIT: Title was a mistake. Should say now I can't compile / download project. Codesys V3.5SP19 Patch 2. Updated the libraries/packages using the Codesys Installer. I'm hit with this error ------ Build started: Application: ------- Typify code... [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0086: No definition found for interface 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0077: Unknown type: 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): Initialize [IecVarAccess]: C0032: Cannot convert type 'IECVARACCESS(iecvaraccess, 4.4.0.0 (system))' to type 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0231: Expression of type 'BOOL' expected in this place [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0077: Unknown type: 'ITFID_IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0046: Identifier 'ITFID_IIecVarAccess17' not defined Compile complete -- 6 errors, 101 warnings Build complete -- 6 errors, 101 warnings : No download possible
Last updated: 2023-09-25

Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023 CODESYS Forge talk (Post)
Hi everybody We are currently working on a project with an RS232 serial COM interface and using the CAA SerialCOM library. We have it working fine reading and writing data, although we have found an issue we cannot resolve and any suggestions would be helpful. We have noticed that after a while the RS232 stops working. We have tracked this down to the HANDLE hCom keeps increasing and when this reaches 1023 the COM returns an unknown error "5003". Is there a way to reset this hCom reference? Thanks Richard
Last updated: 2024-03-22

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02

Post by installwhat on C0077 on one machine but not another CODESYS Forge talk (Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11

Post by pazderai on CanOpen write issue CODESYS Forge talk (Post)
Thank you for an answer. Unfortunatelly, it doesn't work. The slave needs command byte as follows 0x22. It means expedited transfer where s-bit is not set, therefore data length is not specified. If I use segmented mode by CiA405.SDO_WRITE_DATA it produce command byte as follows 0x21 which is unfortunately supported by the slave and it returns with error 0x05040001 - SDO Abort Code -Client/server command specifier not valid or unknown. I can use CAN API low level to overcome this problem where it is possible to set 0x22 as a command byte, but than I can use user interface to set the communication probably, because I thing that machine expert uses library CiA405.SDO_WRITE for setting the slave. Or am I wrong?
Last updated: 2024-07-16

Post by fefefede on Get the numer of day CODESYS Forge talk (Post)
Hello i tro to create a program to turn on or off the air condition in relationship temperature and numer of day. I can't get the number of day. I try this after installing SysTime library but this not work and have this error on debug ------ Build started: Application: Device.Sim.Device.Application ------- Typify code... Generate code... [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'SysTimeCore(TRUE)'' to type 'TIME' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'SysTimeCore' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'DayOfWeek(CurrentTime)'' to type 'INT' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'DayOfWeek' [INFORMATION] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0181: Related position Build complete -- 4 errors, 0 warnings : No download possible PROGRAM PLC_PRG VAR Temperatura: UDINT; AriaCondizionata: BOOL := FALSE; CurrentDayOfWeek: INT; //Variabile Giorno CurrentTime: TIME; GiornoDellaSettimana: INT; DayOfWeek: INT; END_VAR CurrentTime := SysTimeCore(TRUE); // Ottieni l'ora corrente CurrentDayOfWeek := DayOfWeek(CurrentTime); CASE GiornoDellaSettimana OF 1: // Azioni per Lunedì 2: // Martedì se più 10° accend altrimenti spegni IF Temperatura >= 10 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 3: // Mercoledì se più di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 4: // Giovedì se più di 40° accendi altrimenti spegni IF Temperatura >=40 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 5: // Venerdì se più di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 6: // Sabato se più di 25° accendi altrimenti spegni IF Temperatura >=25 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 7: // Domenica sempre spenta AriaCondizionata := FALSE; END_CASE
Last updated: 2023-09-14

Post by marek71 on Ambiguous use of name - CO136 CODESYS Forge talk (Post)
My PLC is WAGO PFC200 Firmware Revision 26. target After updating WAGO_Devices_and_Libraries with newer Firmware 27, CODESYS wants to update all libraries to new versions. I will only add that I did not update the Firmware in the PLC. After compiling the program, I received the following errors: ------ Build started: Application: Device.Application ------- Typify code... [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_RESULT' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0032: Cannot convert type 'Unknown type: 'RTS_INVALID_HANDLE'' to type 'POINTER TO BYTE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0136: Ambiguous use of name 'RTS_INVALID_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0046: Identifier 'RTS_INVALID_HANDLE' not defined [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_tx_empty: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_get_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_line_available: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): COMSW_SET_MODE: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_set_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' Compile complete -- 10 errors, 0 warnings Build complete -- 10 errors, 0 warnings : No download possible The problem was caused by the WagoSysPlainMem(WAGO) library in the original version 1.5.3.0 after updating to 1.5.3.1. After returning to version 1.5.3.0, the problems disappeared. Probably the version number of this library is responsible for supporting the appropriate Firmware Revision. Can anyone confirm or deny my suspicions?
Last updated: 2024-07-06

Showing 25 results of 25