Search talk: var_global

 

override init value for VAR_GLOBAL CONSTANT in library from project. CODESYS Forge talk (Thread)
override init value for VAR_GLOBAL CONSTANT in library from project.
Last updated: 2020-04-13

VAR_GLOBAL CONSTANT mit falschen Werten im Simulationsmodus! CODESYS Forge talk (Thread)
VAR_GLOBAL CONSTANT mit falschen Werten im Simulationsmodus!
Last updated: 2006-10-10

Post by damian177 on Persistence variables PFC200 CODESYS Forge talk (Post)
Hi, I using persistence variables like below: VAR_GLOBAL PERSISTENT RETAIN id_worker1: ARRAY [0..3] OF INT := [231,234,176,222]; id_worker2: ARRAY [0..3] OF INT := [211,129,125,221]; Initial values can cause some problems?
Last updated: 2023-12-08

Post by simotion on Inheritance of axis CODESYS Forge talk (Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07

Post by r-niedermayer on C0564 Warning Message CODESYS Forge talk (Post)
Please see or Online Help on how to initialize variable before using them: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_global_init_slot.html Regarding the Attribute global_init_slot: You can use this pragma to influence the order in which signatures are processed during global initialization. It can only be applied to signatures. By default, the initialization sequence for variables from global variable lists is undefined! However, if, for example, variables from one list depend on variables from another list, it is necessary to initialize one before the other. (Aee OLH and Syntax) The placeholder <slot> must be replaced by an integer value that defines the position in the initialization sequence.</slot> The default value is 50000. A lower value causes an earlier initialization! If several signatures have the same value for the 'global_init_slot' attribute, the order of their initialization remains undefined! Cautious application should therefore be considered! Example: The project contains f.e. two global variable lists GVL_1 and GVL_2. The global variable "A" is part of the global variable list GVL_1: {attribute 'global_init_slot' := '300'} VAR_GLOBAL A : INT:=1000; END_VAR The initialization values of the variables "B" and "C" of GVL_2 are dependent on the variable "A". {attribute 'global_init_slot' := '350'} VAR_GLOBAL B : INT:=A+1; C : INT:=A-1; END_VAR So if you set the 'global_init_slot' attribute of the global variable list GVL_1 to 300, i.e. to the lowest initialization value in the example, then it is ensured that the expression "A+1" is well-defined at the time of initialization of "B".
Last updated: 2024-01-30

Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win CODESYS Forge talk (Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04