User Activity

  • Posted a comment on discussion Deutsch 🇩🇪 on CODESYS Forge

    also 40ms sind sehr sportlich, ich würde >80-120ms empfehlen. Ein Client wird nach meiner Erfahrung nachrausgeworfen, wenn 30s keine Verbindung möglich ist, ist auch im Log an der Zeitangabe >30s ersichtlich. Da scheint sich die Netzwerkverbindung komplett zu verschlucken oder aufzuhängen! Kannst Du in der Zeit auf den Pi über seine LAN Schnittstelle zugreifen? Wie schnell sind denn die verschiedenen Tasks im Codesys eingestellt? Evtl. <1ms? Was läuft sonst noch auf dem Pi, was den zeitweise ausbremsen...

  • Posted a comment on discussion Visualization 🇬🇧 on CODESYS Forge

    I was at the wrong direction! I'm working at the column and they are in the textlist! I searched for my first header and can't find it in the list. After changing it, clean the project etc. it appears there :-) So everything is fine. You are right, a overlay isn't a good idea and will only work, if the table is short enough to be shown completly without a scroll bar!

  • Modified a comment on discussion Visualization 🇬🇧 on CODESYS Forge
  • Modified a comment on discussion Visualization 🇬🇧 on CODESYS Forge

    I'm struggling with nearly the same problem. Is there a way to get the column header into the GlobalTextList?

  • Posted a comment on discussion Visualization 🇬🇧 on CODESYS Forge

    I'm struggling with the same problem. My workaround is to place a label as overlay in each row. There isn't a way to get the words of the header in the GlobalTextList??

  • Posted a comment on discussion Forge 🇬🇧 on CODESYS Forge

    You have tried to get help at support-controls@berghof.com ?

  • Posted a comment on discussion Engineering 🇬🇧 on CODESYS Forge

    pushing up this thread. Somebody can help me?

  • Posted a comment on discussion Engineering 🇬🇧 on CODESYS Forge

    I've the need to change the slave address by IEC code and write it to the EEPROM of the slave. I found the FB ReadWriteEEprom in the EtherCATStackLibrary. Is it possible to do edit the slave addresses with this FB? The story behind: We have AutoConfig deactivated at the MAster to be able to hotplug optional slaves. So we will first boot the PLC with a small application to address the slaves. At this point all slaves come up with address 0 and we want to show a table in the visu to set and change...