  • dmb-fan dmb-fan posted a comment on discussion Deutsch 🇩🇪

    Hi ! Ich habe ein GROSSES V2.3 Programm nach V3.5 SP22 konventiert. Ich bekomme es inzwischen fehlerfrei übersetzt, auch nach "Bereinigen". Wenn ich aber "Alles bereinigen" mache, bekomme ich 102 Fehler. ALLE sind in Schrittketten Bausteinen, ich sehe und verstehe aber nicht das Problem. Es sind immer diese 3 Fehler: [FEHLER] XyProgName: SK_XYZ [IPC: SPS-Logik: Application]: C0009: Unerwartetes Token ':' gefunden [FEHLER] XyProgName: SK_XYZ [IPC: SPS-Logik: Application]: C0189: ';' anstatt 'IecSfc'...

  • dmb-fan dmb-fan posted a comment on discussion Engineering 🇬🇧

    Installing SP17 on an old Win10 PC is working. Are there companys out there who can handle installing software on windows ? Siemens: No Dell: No CoDeSys: No

  • dmb-fan dmb-fan posted a comment on discussion Engineering 🇬🇧

    Oldest possible Sandbox is not working (Converter blacklistet) Install of SP17 sucessfull. But Same error. And now?

  • dmb-fan dmb-fan posted a comment on discussion Engineering 🇬🇧

    I try Sandbox. Now I get messages like "Converter is on the blacklist for this version". Online help says nothing about a too high version for the converter. How I can find out the allowed version? Or is this only for sandboxes? what a jungle !

  • dmb-fan dmb-fan posted a comment on discussion Engineering 🇬🇧

    EDIT: All 32 Bit Version

  • dmb-fan dmb-fan posted a comment on discussion Engineering 🇬🇧

    I had runnig this already. Then I updated to SP22 patch3. After that I got always this error: ===== Project importieren: XXXXnameYYYYYY ===== *[FATALER FEHLER] Fehler beim Import des Projekts: Ausnahmefehler des Servers. * [FATAL ERROR] Error importing the project: Server exception. (Exception to HRESULT: 0x80010105 (RPC_E_SERVERFAULT)) I delete the version and installed again. Same. I uninstalled all CoDeSys on the PC and installed the old SP22 patch2 new. Same error by opening old projects. Immediatly,...

  • dmb-fan dmb-fan posted a comment on discussion Engineering 🇬🇧

    Sounds good. Thx

  • dmb-fan dmb-fan posted a comment on discussion Engineering 🇬🇧

    Hi! I'm currently trying to make my way through this jungle... Hilscher CIFX 50E PCIe cards: DP Master + CANopen Master If I want to run these under Control RTE, do I need a master license from Hilscher for each card? Or do they run entirely with CoDeSys drivers and parameterization tools? I can’t find any clear information on this from either manufacturer. Thanks

1