  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    I tried to change the name of the tap device to 'tap0,' but nothing changed. I don't think this is the problem.

  • Modified a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge
  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi eschwellinger, I changed the name to tap2 due to network issues with Debian (I don't know why it changes the tap0 IP every time the program restarts). Anyway, I think the tap name doesn't affect the connection.

  • Modified a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge
  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi eschwellinger, I changed the name to tap2 due to network issues with Debian (I don't know why it changes the tap0 IP every time the program restarts). Anyway, I think the tap name doesn't affect the connection.

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi eschwellinger, I changed the name to tap2 due to network issues with Debian (I don't know why it changes the tap0 IP every time the program restarts). Anyway, I think the tap name doesn't affect the connection.

  • Modified a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello, I've been trying to use EoE for communication between a Windows PC and an M753 drive from Control Technique. Despite following some online guides (https://content.helpme-codesys.com/en/libs/EtherCATStack/4.3.0.0/Ethernet_over_EtherCAT/fld-Ethernet_over_EtherCAT.html) I haven’t had any success. Both are connected to a Debian device where RTE is running: The PC is connected via the Ethernet port. The drive is connected via the EtherCAT port. I'm unable to ping the drive from my Windows PC. Here...

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello, I've been trying to use EoE for communication between a Windows PC and an M753 drive from Drive Control Technique. Despite following some online guides, I haven’t had any success. Both are connected to a Debian device where RTE is running: The PC is connected via the Ethernet port. The drive is connected via the EtherCAT port. I'm unable to ping the drive from my Windows PC. Here is my configuration: On Debian: (See attachments 1, 2, 3) enp1s0 = Ethernet port enp2s0 = EtherCAT port tap2 =...