Personal Data

Username:
konstantin
Joined:
2022-07-14 18:53:13
Location:
Bulgaria / EEST
Gender:
Male

Projects

  • No projects to display.

User Activity

  • Modified a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, In our workshop we have a PFC200 and a module 750-653/003-000 laying around my table. Our workshop project is still in the e!cockpit environment and we started trying to migrate it to CODESYS 3.5. We have a few energymeters that are read via MODBUS RTU to our current PFC200 but using 750-652 module. My last try with the 750-653 module was not successful with the e!cockpit therefore I decided to try it with COESYS. Now I use FbMbMasterSerial function block but there is no response from the energymeters...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, Hi, In our workshop we have a PFC200 and a module 750-653/003-000 laying around my table. Our workshop project is still in the e!cockpit environment and we started trying to migrate it to CODESYS 3.5. We have a few energymeters that are read via MODBUS RTU to our current PFC200 but using 750-652 module. My last try with the 750-653 module was not successful with the e!cockpit therefore I decided to try it with COESYS. Now I use FbMbMasterSerial function block but there is no response from the...

  • Modified a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I use a WAGO PFC200 controller with MODBUS RTU on the integrated port. There are 8 damper valves for ventilation and 6 energymeters that are connected to the fieldbus. Since I have to do a lot of mapping of the raw I created some function blocks but I cannot figure out how to do a specific addressing for an identifier. There is Modbus objects - one of them in my case is "Energymeter_1" and the datatype is "typEnergymeter_1_rtu". Therefore when I want to access a variable from "Energymeres_1"...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I use a WAGO PFC200 controller with MODBUS RTU on the integrated port. There are 8 damper valves for ventilation and 6 energymeters that are connected to the fieldbus. Since I have to do a lot of mapping of the raw I created some function blocks but I cannot figure out how to do a specific addressing for an identifier. There is Modbus objects - one of them in my case is "Energymeter_1" and the datatype is "typEnergymeter_1_rtu". Therefore when I want to access a variable from "Energymeres_1"...

  • Modified a comment on discussion Motion πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, Our company bought an AX-308 Motion Controller, I have been researching about its function but I am struggling with mapping limit and home switches via communication. The motion controller is an EtherCAT based and all the servo drivers (ASDA-B3) are EtherCAT as well. We have 4 servo drivers that must be equipped with two limit and two home switches. The goal is to wire all the sensors to the motion controller inputs and to send them via EtherCAT to the servo driver. We avoid soldering the signal...

  • Modified a comment on discussion Motion πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, Our company bought an AX-308 Motion Controller, I have been researching about its function but I am struggling with mapping limit and home switches via communication. The motion controller is an EtherCAT based and all the servo drivers (ASDA-B3) are EtherCAT as well. We have 4 servo drivers that must be equipped with two limit and two home switches. The goal is to wire all the sensors to the motion controller inputs and to send them via EtherCAT to the servo driver. We avoid soldering the signal...

  • Posted a comment on discussion Motion πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, Our company bought an AX-308 Motion Controller, I have been researching about its function but I am struggling with mapping limit and home switches via communication. The motion controller is an EtherCAT based and all the servo drivers (ASDA-B3) are EtherCAT as well. We have 4 servo drivers that must be equipped with two limit and two home switches. The goal is to wire all the sensors to the motion controller inputs and to send them via EtherCAT to the servo driver. We avoid soldering the signal...

View All