  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello everyone, I have a problem while I start Codesys runtime on Raspberry Pi board. the Runtime shutdown with "ooops... this runtime was built for RASPBERRYPI (-1, 0x00000BB8, 0xFFFFFFFB)" I looked for the same issue with mine but I couldn't find it. Could you help me to solve this issue? System Info Raspberry PI 4 model B Rev 1.4 Raspberry PI SL 4.2.0.0 Raspberry Pi OS (Bullseye)

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, all. I wonder whether it is possible to use retain Vars on SL product(except embedded board), if I install extra NVRAM(PCI card type).

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Simple recipe manager example using RecipeManCommands(F/B)

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello, everyone I would like to ask you about Redundancy Sync problem. I am using two Raspberry pi SL and I set redundancy configuration and it wrote in 'CODESYSControl_User.cfg'. Also, I checked that a boot application was created and it synced without any problems. However, when I turn off the power of both RPis and turn them on at the same time. The redundancy state remained [Standalone - Standalone] as shown in the attached file. How could I make them sync automatically? when I turn them on at...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello, everyone When I try to install device description(.xml) to CODESYS IDE, the below mesg shows up. "Unable to import device description file The type {GUID} Could not be found" I've been through couple of missing plug-in problems on SP 17 or higher. It seems that this issue also caused by same problems Could you help me to solve this?

  • Posted a comment on discussion Automation Server πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi everyone, I tried to write values on Automation Server. However, It seemed that Server wrote a value periodically even though I would like to write it only once. Is there any way to write a value only once not periodically? thanks in advance.

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Problem solved. I found "VisuTrendStorageAccess" Lib

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello all, I would love to change the trend time data to DT format or human readable format. I tried to convert it to DT or LDT but It didn't work. Can I get some help about this?