  • mgengler mgengler posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Thanks for info... However, I changed the directory to: C:\ProgramData\CODESYS\CODESYSControlWinV3x64\58719825\PlcLogic\Recipes It still displays the content of this folder OK, however still will not write or read files. Is this the PLCLogic area you speak of? I also tried adding this path the the CodesysControl.cfg file. But still can't get it to work. Any additional direction would be appreciated!

  • mgengler mgengler posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Recipe Manager will load windows explorer view and allow file name to be typed in or existing file selected but will not create a new file or overwrite an existing. Will not create a file in the default folder or even a defined folder like "c:\recipes\" although it does properly navigate to that folder location. I made sure the folder is not read-only. Can't figure out what is missing...

  • mgengler mgengler posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Attempting to login into RTE 3.17.20 to monitor online/online changes with credentials I setup when first logging into the runtime and have been successfully for several weeks. Suddenly I am unable to login saying "You are currently not authorized to perform this operation on the device". If I attempt to login using admin from visualization configuration I get "Invalid user authentication on the target" Can you let me know why I am suddenly unable to login and how I can fix this issue?

  • mgengler mgengler posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    During the codesys installation it gets as far as the "Install all Packages added to the setup" and freezes. I have uninstalled and attempted re-installation several times and cannot get install to continue.

  • mgengler mgengler posted a comment on discussion Runtime

    I have been running RTE for several months and all of a sudden the runtime won't start. I believe Windows may have done an update as someone enabled the internet on the computer that I cannot roll back. All of the bios settings seem to be good and the service icons appear in the tray. When I choose PLC configuration I get prompted to reload the tray with administrator rights before the configuration box will come up. When starting the PLC I get the message stating no response from the PLC and the...

  • mgengler mgengler posted a comment on discussion Engineering

    I am trying to run a Python script from Codesys Runtime triggered from a Visualization event. Does anyone have an example to do this from a Windows RTE runtime?