Personal Data

Username:
never-settle
Joined:
2022-02-02 19:20:30

Projects

  • No projects to display.

User Activity

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi BY, yes, CANopen makes sense, as device 1 cannot handle J1939. I think the common thing with the setup of CANopen will be the use of an EDS file. I've done this several times without problems. CSV I have no experience. So I think the problem comes down to converting the two DBC files into EDS files, which I have yet to figure out. Thanks and kind regards, Stefan

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Dear BY, thanks a lot! So if I convert the .dbc file into a .csv file, I will be able to set up the node automatically by solely reading the .csv file into Codesys, into a CANopen Manager? Best regards, Stefan

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Dear BY, thanks a lot! The .dbc file causing the problem can be downloaded from https://app.box.com/s/vf9259qlaadhzxqiqrt5cco8xpsn84hk/folder/134048861771 Thanks and kind regards, Stefan

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Dear BY, thanks a lot! I tried, but didn't get very far. One device I am trying to set up runs on CAN 2.0B /ISO 11898-1: Baudrate:500Kbps. Another I also tried runs on 2.0A or 2.0B (extended identifier), but neither works. I set up SP17, created an empty project and added a J1939 manager. Then I pressed "Import DBC file", selected the DBC file and clicked "OPEN". Then a small window "DBC content selection" pops up. There I can choose if I want to import a particular module or not, and whether it...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Dear BY, thanks a lot for your quick response! So when I use SP17 to load the .dbc file in, the CAN adapters etc. should actually be SP10 or older, such that I can then copy and use them within my original project running on SP10? Is that what you mean? So there is no point in reading the .dbc files into a CAN adapter of version SP17, as it won't then run on any older version, right? Thanks and kind regards, Stefan

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Dear BY, what you propose seems to be precisely what I need. I work with SP10 and am troubled with setting up some nodes, for which I only have .dbc files. If I understand you correctly I could: Download SP17 Read the .dbc file into a project in SP17 Copy the generated setup to my SP10 project Correct? Does the fact that I copy code from a never version into an older environment not create any issues? Thanks a lot! Kind regards, Stefan

View All