  • Modified a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Can anyone shed some light on this issue im having. at random, sometimes days, sometimes weeks or months. i get this error and have to reset the plc. Im using a Weintek HMI with ethernet/ip remote io and vsd. i have tried increasing my task times and watchdogs. and when i view my PLCload in the shell its normally around 3-4%, highest ive ever seen is 7%. Nothing i do seems to help the issue. Could the HMI's Codesys CPU be getting to hot do to high ambient temp?

  • Modified a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Can anyone shed some light on this issue im having. at random, sometimes days, sometimes weeks or months. i get this error and have to reset the plc. Im using a Weintek HMI with ethernet/ip remote io and vsd. i have tried increasing my task times and watchdogs. and when i view my PLCload in the shell its normally around 3-4%, highest ive ever seen is 7%. Nothing i do seems to help the issue. Could the HMI's Codesys CPU be getting to hot do to high ambient temp?

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Can anyone shed some light on this issue im having. at random, sometimes days, sometimes weeks or months. i get this error and have to reset the plc. Im using a Weintek HMI with ethernet/ip remote io and vsd. i have tried increasing my task times and watchdogs. and when i view my PLCload in the shell its normally around 3-4%, highest ive ever seen is 7%. Nothing i do seems to help the issue. Could the HMI's Codesys CPU be getting to hot do to high ambient temp?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    So you don't see the device when scanning for devices? Im not familiar with that device. how dose it connect? serial/ethernet?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    So did you get it working?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    i had a similar problem trying to send files to C: on local computer. Ended up using Oscat ftp to transfer file with filezilla. i read there is an "write protection", possibly to do with windows, issue with sp19 and up. there are some config files in the codesys dir you can change, which may help. after i was able to transfer to local PC\downloads but not c: so went the ftp route. works well. https://forge.codesys.com/forge/talk/Runtime/thread/5cac1390b4/

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    VAR CONSTANT size : INT := 10; END_VAR My_Array : ARRAY[1..SIZE , 1..5] OF REAL;

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    IN THE MAPPING COLUMN, TRY CLICKING THE ICON TO "MAP TO EXISTING VAR"