Projects

  • No projects to display.

User Activity

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    I've been using various versions of these IFM AL modules, to varying levels of success. A few notes. Before SP17P2 the Profinet overhead was rather greedy and caused all sorts of problems in the soft controllers we used. I highly recommend using the 4.2.0.0 or 4.2.1.0 version if you're planning on using the Profinet master stack. Profinet_CommunicationTask can be slowed down - it's acyclic less important stuff. Profinet_IOTask running on recommended interval 1ms pre-4.2.0 ate all my resources. After...

  • Modified a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Before you build your project again, in Device window open the PLC Settings tab. Select Enabled 1 or Enabled 2 under Always update variables. You now should be able to see your I/O when going online.

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Before you build your project again, in Device window open the PLC Settings tab. Select Enabled 1 or Enabled 2 under Always update variables. You now should be able to see your I/O when going online.

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    That seems to have worked, thanks!

  • Modified a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I'm running a (v 3.5.17.0) compiler on Phoenix-Contact PLCNext 2152/2404267 (Codesys control for PLCNext v4.1.0.0, using 2021.0 LTS firmware) as an ETHERCAT master. The system also uses an extension module for the additional network interface (AXC F XT ETH 1TX/2403115, Intel I210 based). If i use eth0 or the primary network interface as the Ethercat master, everything is running fine, my existing Ethercat devices are found and accessible. If i switch the master to use enp1s0 - the network interface...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I'm running a (v 3.5.17.0) compiler on Phoenix-Contact PLCNext 2152/2404267 (Codesys control for PLCNext v4.1.0.0, using 2021.0 LTS firmware) as an ETHERCAT master. The system also uses an extension module for the additional network interface (AXC F XT ETH 1TX/2403115, Intel I210 based). If i use eth0 or the primary network interface as the Ethercat master, everything is running fine, my existing Ethercat devices are found and accessible. If i switch the master to use enp1s0 - the network interface...