  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello, I have been trying to use the ModbusFB functions so I can put some code into libraries, but it seems to be very slow for me. I have a Modbus device with 100ms registers. I previously setup 10 channels in the 'traditional' Modbus Slave with channels and mappings - and set a cyclic trigger at 100ms - this worked fine. I then tried the ModbusFB example, and setup reading the same 10 blocks of modbus addresses, copying the example and putting all of the requests into an array and triggering the...

  • Modified a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi all, I have updated via Tools->Installer, but the Modbus Slave Device is not updated - so the Modbus Master and Modbus Slave are at v4.3.0. But when I then add a Slave to the Modbus Master Device - it will only allow 4.1.0 - which still has the 10 channel limit? Am I doing something wrong? Structure: Master Device: Slave Device: Add channel greyed out: Installer:

  • Modified a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi all, I have updated via Tools->Installer, but the Modbus Slave Device is not updated - so the Modbus Master and Modbus Slave are at v4.3.0. But when I then add a Slave to the Modbus Master Device - it will only allow 4.1.0 - which still has the 10 channel limit? Am I doing something wrong? Structure: Master Device: Slave Device: Add channel greyed out:

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi all, I have updated via Tools->Installer, but the Modbus Slave Device is not updated - so the Modbus Master and Modbus Slave are at v4.3.0. But when I then add a Slave to the Modbus Master Device - it will only allow 4.1.0 - which still has the 10 channel limit? Am I doing something wrong? Structure: Master Device: Slave Device: Add channel greyed out:

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Thanks for clarifying kislov! I have just opened up an old project, in v3.5 SP16, the modbus definitions were missing (3.15.0.0), so I "Downloaded the missing device description", now I get a build error saying: Max. number of Channels (10) exceeded ! - has the bug been introduced along with the release of SP19 but is backwards applicable as well for any downloads - older versions included?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi kislov, not sure if it would make any difference, but I tried adding a new modbus device in v3.5 SP16 - it wanted to add the latest version 4.1.0.0 - I proceeded to add channels, and it will allow me to add more than 10 channels. It seems like it is SP19 that is introducing the limit, rather than the modbus device specifically.

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi kislov, thank-you for the update, I have found a work-a-round for now as I upgraded to start using Git. I did try downgrading (using update, and showing old versions) one of the modbus devices so it is version 3.5.16.0 - but it still had the 10 channel limit. As a work-a-round for now if it helps anyone else, it seems I can create the modbus device with all the needed channels in an old project from v3.15 SP16 for example, then copy and paste it into the new project, then use the update device...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I have just updated a project from SP16 to SP19. I have added a new Modbus TCP Slave Device and started adding channels - I have added 10 and now it has greyed out the Add Channel button. Does anyone know if this is a bug, or a setting which needs changing? I opened another device which is already in the project, it has 81 channels already - but does have the button to add more greyed out?! Thank-you in advance!