Hmm, can't seem to find anything named "plclogger" ? edit: Looked through older posts and saw that you ment the log files in the root device. See attached image.
Hmm, can't seem to find anything named "plclogger" ?
If you mean logs on the profinet device, see the attached image.
Hey! Got it to work now. Kind of. I already had that in my config file, but it still didn't work. However, It works if i start up everything in TIA aswell as running the runtime then typing: sudo ifdown eth0 sudo ifup eth0 to reset the network adapter, then all goes green in both codesys aswell as TIA. I would still say this is some kind of weird glitch as this most likely isn't supposed to be happening..
Managed to fix it by adding a PN_Controller besides the profinet device and then exporting a new GSDML to TIA. When the TIA project has been loaded and is up and running then the bus is active. However, now I've got a new problem where the I/O's don't show up in TIA.. Anyone with a familiar issue?
Hey! Trying to have my raspberry pi as a profinet device linked to my S7 1200 PLC. Currently I'm facing an issue where the bus is not running. Version: CODESYS V3.5 SP16 Patch 4 + Raspberry pi runtime 4.0.1.0 I've also followed this guide: https://help.codesys.com/webapp/_pnio_runtime_configuration_device;product=core_ProfinetIO_Configuration_Editor;version=3.5.16.0 I also attached the log files from the Profinet Device. The device shows up in TIA but its not reachable, obviously cause the bus isn't...
Haha you remembered correctly! Thanks alot, that really helped π
Haha you remember correctly! Thanks alot, that really helped π
Hello, what steps did you take to generate the GSD file? Thanks, Anton