  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Sorry to bother but what do you mean by target ?

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Hey, I am facing the same problem. Basically UA Expert and other programs work fine with the login credentials. But codesys can not use them properly. I can see the server login to it manually but when I download the program and run the datasource never runs... Currently I am facing the same Error ID: 7012 and cant get it running properly.

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hey, I am facing the same problem. Basically UA Expert and other programs work fine with the login credentials. But codesys can not use them properly. I can see the server login to it manually but when I download the program and run the datasource never runs...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hello? I have a problem with datasource... I am trying to connect to a OPCUA server. I create a datasource, but I can not login into it. I need to use login credentials to login... Everything works fine in UAExpert, but in codesys I cant seem to get in properly using the login credentials... I have tried to configure the datasource initializer but seem to keep failing... Do I need to call it somewhere ? Will the find endpoints work with this configured to store my password ? !

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    No, not really

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Hello, its still not quite clear to me how to deal with the PLCLogic directory in linux. I have the directory right here: I need to correctly access the files in this folder through CODESYSControl.cfg. Here is my CODESYSControl.cfg where on the first lines there are a few lines: [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 That means that if I am going to use relative paths its going to go to from the PLCLogic directory right ? For example here: Whitch paths should I use. I cant seem to successfully...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hello, its still not quite clear to me how to deal with the PLCLogic directory in linux. I have the directory righ here: And here is my CODESYSControl.cfg where on the first lines there are a few lines: [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 That means that if I am going to use relative paths its going to go to from the PLCLogic directory right ? For example here: Whitch paths should I use. I cant seem to successfully run any of these aproaches ...

  • vformanek vformanek modified a comment on discussion Runtime 🇬🇧

    I have tried downgrading and it seems fine now. I am now on version 4.3.0.0 for the library. Mainly the PN controller caused the issue for me. Funny weird is that even the PN controller versions 4.3.1.0 and 4.3.0.0 cause the error. Version 4.2.0.0 works fine.

  • vformanek vformanek modified a comment on discussion Runtime 🇬🇧

    I have tried downgrading and it seems fine now. I am now on version 4.3.0.0 for the library. Mainly the PN controller caused the issue for me. Funny weird is that even the PN controller versions 4.3.1 and 4.3.0 cause the error. Version 4.2.0 works fine.

  • vformanek vformanek posted a comment on discussion Runtime 🇬🇧

    I have tried downgrading and it seems fine now. Funny weird is that even versions 4.3.1 and 4.3.0 cause the same error. Version 4.2.0 works fine.

  • vformanek vformanek modified a comment on discussion Runtime 🇬🇧

    Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.

  • vformanek vformanek posted a comment on discussion Runtime 🇬🇧

    Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... [-img src=call stack.png width=100%: missing =-] I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.

  • vformanek vformanek posted a comment on discussion Deutsch 🇩🇪

    Ich habe derzeit ein Problem mit meiner CIFX PB-Karte, die ich mit CODESYS Control for Linux SL zum Laufen bringen möchte. Ich habe bereits versucht, im Engineering Forum zu fragen... Ich bin mir nicht sicher, was ich noch tun kann, um die Karte zum Laufen zu bringen. Ich habe die Firmware-Dateien auf den Linux-Rechner heruntergeladen, auf dem sich die Karte befindet, und wenn ich das SYCON.net-Programm benutze, ist die Karte betriebsbereit und läuft. Ich kann sogar Geräte auf dem Bus finden. Aber...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Could there be a problem with CODESYS version ? I am using 3.5.18 Patch 5.

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Anybody got any suggestions? I have successfully made the card running and operational in the program SYCON.net but no luck in CODESYS... I would really like to make the card finally running.

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    I have been attempting to diagnose the issue, and at present, I am encountering a problem with the card drivers not being loaded correctly by the CODESYS runtime. The log file shows the following message: Moreover, I am still unable to recognize the firmware on the card, and the Profibus DP is not functioning, which is illustrated in the 'problem.png' image. In my efforts to resolve this matter, I have referred to the following manual: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_runtime_configuration_cifx.html...

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Firstly, thanks for the help so far! Following your advice, I've managed to get the device downloading without any issues. However, it's still not fully up and running - I'm seeing "Device is configured, but not fully operational. No data is exchanged." The attached image might give you a better idea of the current state: Also, the CIFX card is throwing this error: "internal CIFX error, e.g during firmware configuration or bus startup." It seems the bus startup might be the sticking point here. Have...

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Firstly, thanks for the help so far! Following your advice, I've managed to get the device downloading without any issues. However, it's still not fully up and running - I'm seeing "Device is configured, but not fully operational. No data is exchanged." The attached image might give you a better idea of the current state: Also, the CIFX card is throwing this error: "internal CIFX error, e.g during firmware configuration or bus startup." It seems the bus startup might be the sticking point here. Have...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Firstly, thanks for the help so far! Following your advice, I've managed to get the device downloading without any issues. However, it's still not fully up and running - I'm seeing "Device is configured, but not fully operational. No data is exchanged." The attached image might give you a better idea of the current state: Also, the CIFX card is throwing this error: "internal CIFX error, e.g during firmware configuration or bus startup." It seems the bus startup might be the sticking point here. Have...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hello, fellow members! I'm currently dealing with an issue involving my CIFX PB card that I'm trying to get to work with CODESYS Control for Linux SL. I'm at a bit of a loss when it comes to configuring the CIFX card so that it's visible. Does anyone have any experience or know of any tutorials that detail the steps for CODESYS startup? I've managed to successfully install the Hilscher FW on my Linux machine, but now I'm stuck trying to get the card to work with CODESYS properly. In my search for...

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    I feel like im getting somewhere, if we could get this whole variable into an array or something, then we could see the name of the devices as variables, even if we could get to that specific device by the name then we could extract the INode 16#xxxx value and compare it with all the nodes from IoConfig_Globals.DeviceNodes. Now we just need to figure out if we can put this whole variable into something more info in the image bellow.

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    I am facing a quite simmilar problem so I will try to look into it. Could you provide your latest functionality about knowing what type of node it was?

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    interesting topic, have you found a way to do it yet ?

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    nevermind, I did something wrong in the conversion, my bad. Thanks!

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    I have tried this approach, but it seems to be inconsistent. Here is the code i have come with: TYPE uDINTBytes : UNION rValue: UDINT; abValue: ARRAY [0..3] OF BYTE; END_UNION END_TYPE But here is the output whitch is wrong.

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    could you provide a screenshot solution of the block call ? i seem to get exceptions about access violation when running the program

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    I have a UDINT value whitch represents PNIO_Status and i would like to convert it to 4 bytes so i can decode it by this website: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_diagnosis_pnio_state.html How can i convert the UDINT value to 4 BYTES so it would corespond to the page I have provided earlier ?

  • vformanek vformanek posted a comment on discussion Deutsch 🇩🇪

    Hallo, ich stehe vor einem Problem, bei dem ich einige Diagnosen vom Bus und dem Gerät erhalten möchte, ob beide laufen. Ich möchte die Tags im Bild in eine Variable erhalten, die ich in einem Programm verwenden könnte. Höchstwahrscheinlich irgendwie konvertieren die ADAPTERSTATE und andere Typen wie diese (ETHERNETSTATE, SCANNERSTATE) zu etwas nützlich.

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hello I am facing a problem where I want to get some diagnostic from the bus and the device whether is both running. I want to get the tags in the image to a variable whitch i would be able to use in a program. Most likely somehow convert the ADAPTERSTATE and other types like this (ETHERNETSTATE, SCANNERSTATE) to anything usefull.

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hello, I am currently doing a project with profinet IO-link master device and I cant plug in IODD device file. When I try to run with Ethercat IO-link master device the IODD device shows up and I am able to plug it in. What is wrong here? Does PROFINET support the IODD files ? Is it a problem specifically in the IO-link master that it does not support the IODD compatibility ?

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Okay guys I think it is working.. Still needs to be tested but when I reinstalled CODESYS here are the steps I have done: 1. Install CODESYS 3.5.18.20 2. Restart PC 3. Dont open CODESYS !!! Open CODESYS Installer 4. Install Libraries with CODESYS Installer (It did not throw the error when CODESYS was not open) 5. Restart PC 6. Start CODESYS Please try this aproach and keep me posted !

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Repairing did not work either. I allways need to uninstall and try again. Only thing that worked for me was installing the packages solo by their separate instalators. Codesys installer cant install it properly and allways throws these errors and then the CODESYS installation is corrupted again... @pilgrim - maybe you could try to install the package by its separate installer, you can download the package on codesys store @eschwellinger - Im going to try the event viewer

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Repairing did not work either. I allways need to uninstall and try again. Only thing that worked for me was installing the packages solo by their separate instalators. Codesys installer cant install it properly and allways throws these errors and then the CODESYS installation is corrupted again...

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Hello, I am currently facing an error while trying to download and update libraries through Package Manager. I am using CODESYS V3.5.18.20. When I select and start the installation of the libraries it throws me an error attached to this issue bellow. However when I abort the installation and start again it does not throw the error again. But the whole instalation of CODESYS is corrupted. How do I fix this problem please ?

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Hello, I am currently facing an error while trying to download and update libraries through Package Manager. I am using CODESYS V3.5.18.20. When I select and start the installation of the libraries it throws me an error attached to this issue bellow. However when I abort the installation and start again it does not throw the error again. But the whole instalation of CODESYS is corrupted. How do I fix this problem please ?

  • vformanek vformanek modified a comment on discussion Engineering 🇬🇧

    Hello, I am currently facing an error while trying to download and update libraries through Package Manager. I am using CODESYS V3.5.18.20. When I select and start the installation of the libraries it throws me an error attached to this issue bellow. However when I abort the installation and start again it does not throw the error again. But the whole instalation of CODESYS is corrupted. How do I fix this problem please ?

  • vformanek vformanek posted a comment on discussion Engineering 🇬🇧

    Hello, I am currently facing an error while trying to download and update libraries through Package Manager. I am using CODESYS V3.5.18.20. When I select and start the installation of the libraries it throws me an error attached to this issue bellow. However when I abort the installation and start again it does not throw the error again. But the whole instalation of CODESYS is corrupted. How do I fix this problem please ?