Post by domebruce on TCP communication and TCP Streams
CODESYS Forge
talk
(Post)
Hello, I'm doing some tests with TCP communication using Reader, Writer and TCP_Process components from NBS 4.0. I'm having a really hard time finding documentation and examples on these components. I found a very simple and incomplete example here: https://forge.codesys.com/prj/codesys-example/nbs/home/Home/. The documentation is also insufficient: it only provides the names of the FBs, Methods and their parameters, but no descriptions about how to use them. Do you have any suggestions on where to find more support? More generally, why is the free online CoDeSys documentation so poor? What do you think? Thanks Domenico Canavero
Last updated: 2026-06-16
Post by eschwellinger on Connection to device closed
CODESYS Forge
talk
(Post)
is there a way to check the plclog on Opus A3 by using cmd line under Linux? This log is what you need to check for the disconnection problem
Last updated: 2023-08-24
Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
Thank you for the return. The path targets to a CFast card. User has R/W access to it. We will try to change it.
Last updated: 2023-08-31
Post by felipemsgarcia on EtherCAT - Force Control Word
CODESYS Forge
talk
(Post)
What worked for me: Use SMC_SetControllerMode and set the nControllerMode to SMC_nocontrol. With that, you can control the drive via Modes of Operation(16#6060) and Controlword(16#6040) directly. Hope that helps, Cheers!
Last updated: 2023-08-31
Post by eschwellinger on Ethercat scan for devices not picking up EL7041 as a softmotion axis
CODESYS Forge
talk
(Post)
Add existing version (with SM drive) - without scan - disable under expert settings in the slave the revision check.
Last updated: 2023-09-03
Post by aguado on Setting up the "Visual Studio Code" debugging environment (using .NET debugging) for use with the ScriptEngine API in Python.
CODESYS Forge
talk
(Post)
Hi, did you ever get this to run? Best Till
Last updated: 2023-09-12
Post by transmin01 on PCAN serial "No CAN driver found"
CODESYS Forge
talk
(Post)
Second question is, how do I determine the correct network ID for my Canbus config in Codesys? I have 2 CANbus ports on the target PC. Regards Trevor
Last updated: 2023-09-14
Post by sedoerr on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
You need to create a function around this function to check the dialogs you use in your program. That's the way i have done it.
Last updated: 2023-09-26
Post by gurke258 on EL2911
CODESYS Forge
talk
(Post)
Hello, sorry to open this again. I can't find the right ESI for EL1918 as Safety PLC.. I only have the one without safety PLC. I look on Beckhoff website but i didnt found it. Can anyone help me? EDIT: I found it :)
Last updated: 2023-10-12
Post by armall on USB <-> CAN, CANfox, Component CmpCANFoxDrv NOT loaded
CODESYS Forge
talk
(Post)
@eschwellinger, I don't understand what you mean by 'CANfox must also go' (English translation). Do you mean that the support for the CANfox must go? Have you any guidance as to get this working?
Last updated: 2023-10-16
Post by vincentd on Datasource OPC UA Client error ID:7012
CODESYS Forge
talk
(Post)
I had some help from Codesys to debug this problem. It seems there was a problem within the target (a bug?). I only used for a proof of concept. Possibly it will work with a new version of the target
Last updated: 2023-11-21
Post by nathant on Easiest RevPi PLC to configure HMI visualization with?
CODESYS Forge
talk
(Post)
I'm worried that the Core SE (which I was originally going to go with) will not be straight foward in terms of setting up the HMI visualization. This is for an offline application, if that matters.
Last updated: 2023-11-28
Post by nathant on Easiest RevPi PLC to configure HMI visualization with?
CODESYS Forge
talk
(Post)
I'm worried that the Core SE (which I was originally going to go with) will not be straightfoward in terms of setting up the HMI visualization. This is for an offline application, if that matters.
Last updated: 2023-11-28
Post by mucleus on What is the solution for "Application stopped on recovery switch request"?
CODESYS Forge
talk
(Post)
Component ID 10 is my own log message by LogAdd Function. I want to know in what cases the application stops.
Last updated: 2024-07-09
Post by installwhat on What is the solution for "Application stopped on recovery switch request"?
CODESYS Forge
talk
(Post)
Well still similar questions remain. I don't know of "CmpRecoverySwitch" and the only thing google has to offer is your xml file. I think you'd need to provide a lot more info before anyone makes much effort here.
Last updated: 2024-07-09
Post by installwhat on No connection to target: An existing connection was forcibly closed by the remote host
CODESYS Forge
talk
(Post)
Worked for me too. Now I have to find out why I didn't need to do this on very similar systems and what the security issue is
Last updated: 2024-08-11
Post by ralfki on User management
CODESYS Forge
talk
(Post)
Hello CodeSYS community, Is there a CodeSys function with which you can activate user management or is this only possible with the CodeSYS development environment? Thanks for the support
Last updated: 2024-09-02
Post by lyngaansns on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
Hello I am looking for the same thing, so i don't have an answer, but in your case you could possibly use the --noUI flag when running codesys, if you don't care about showing what's happening.
Last updated: 2024-09-06
Post by runtimevictor on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Thank you very much for answering, I look forward to the example. As soon as the example or documentation is available, please let me know... thank you.
Last updated: 2024-09-10
Post by thn-power on Codesys Communication Manger - Required information model version exists in the model repository but is not found
CODESYS Forge
talk
(Post)
Hi Did you found a solution for this? I also have the same problem
Last updated: 2024-09-18
Post by hanpekel on Reading request counter value from modbus server in application
CODESYS Forge
talk
(Post)
Any way I can read the value of the 'request counter' (see screenshot) in my application. Amount of client connections is easily found using ModbusTCP_Slave_Device.uiClientConnections; But for request counter it does not seem to be that simple.
Last updated: 2024-10-16
Post by eschwellinger on Problem with edge gateway config mode
CODESYS Forge
talk
(Post)
if this does not work, you could install the 3.5.20.0 Gateway from the CODESYS Store. https://store.codesys.com/de/codesys-edge-gateway-for-windows.html then it is possible to enable it by righclick inthr task tray
Last updated: 2024-10-21
Post by lsislsis on Alarm Table rows font size not change
CODESYS Forge
talk
(Post)
When we try to change the font size of alarm table headers change as excpected but timestamps and messages not change and keep one small size from the begining. Is there any solution for that? Regards
Last updated: 2024-10-23
Post by markushunter on loading delay with the option "check client animations and overlay of native elements"
CODESYS Forge
talk
(Post)
Hey etiennenneu, I have the same problem with our prototype cell application. Do you have found a workaround for it? Best regards, Markus
Last updated: 2024-11-04
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
This is the operating system and has nothing to do with the runtime. Unless you use 64bit commands. You can see for yourself that you have errors with 64bit compilers
Last updated: 2024-11-09