Post by talhaali on Adding a variable from text list into ST code
CODESYS Forge
talk
(Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i use want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07
Post by talhaali on Adding a variable from text list into ST code
CODESYS Forge
talk
(Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07
Post by evanclegg on Digital Clock
CODESYS Forge
talk
(Post)
To display the current time, you’ll need to retrieve it from the system clock. In CODESYS, you can use the built-in function SysTime to get the current system time. Here’s an example of how you can use it: VAR dtCurrentTime: DATE_AND_TIME; sTime: STRING(8); END_VAR dtCurrentTime := SysTime(); sTime := TIME_TO_STRING(dtCurrentTime.t); The sTime variable now contains the current time in the format “HH:MM:SSuno online".
Last updated: 2024-02-28
Post by nano on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
this is not easily. From Point of SL-Licenses Codesys didnt provide the informations how to do. We created an own CDS-Component for that Behaviour. This Informations are available for OEM, if you are an OEM you can find the Informations in the RTS-Documentation.
Last updated: 2024-06-14
Post by thedertom on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
Hi I try to get korean texts out of a textlist. For that I want to use DynamicTextGetTextW, but I am a little confused how it is supposed to work. The function returns POINTER TO STRING, but how do I get WSTRING? I succesfully used DynamicTextGetText with classical Strings. Thanks in advance!
Last updated: 2024-09-02
Post by edson-bueno on SysProcess Execute Command unable to run commands with special characters
CODESYS Forge
talk
(Post)
Hi, I found the same issue, and I fixed with this steps: 1st go to codesys .cfg file. sudo nano CODESYSControl.cfg Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll Now we need to grant codesys root rights on Linux. Step 1: Create or edit the systemd override configuration: sudo systemctl edit codesyscontrol In the editor that opens, insert: [Service] User=root Save and exit: Press Ctrl+O to save Press Ctrl+X to exit Step 2: Reload systemd and reboot To apply the override: sudo systemctl daemon-reexec sudo systemctl daemon-reload sudo reboot Step 3: Confirm CODESYS is running as root After reboot, open the terminal and run: ps aux | grep codesyscontrol You should see something like: root 1234 ... /opt/codesys/bin/codesyscontrol.bin ... If instead it shows admin or another user, the override was not applied correctly. Step 4: (Optional) Confirm from within CODESYS In your CODESYS project, insert this test code to run the Linux command whoami: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR refCommand REF= sCommand; refOutput REF= sOutput; SysProcessExecuteCommand2( pszCommand := refCommand, pszStdOut := refOutput, udiStdOutLen := SIZEOF(sOutput), pResult := ADR(resultCmd) ); Notes & Warnings This method gives full system access to the CODESYS runtime — do not expose this system to the public network without protection. Do not use sudo in commands inside CODESYS when the runtime is already running as root. @tomas111, in case you want to read the temperatur, use this command: sCommand:STRING:='/usr/bin/vcgencmd measure_temp';
Last updated: 2025-05-20
Post by timvh on STRING conversions to DWORD
CODESYS Forge
talk
(Post)
I guess that the printer expects to receive an array of byte values. So where it is described that it expects to receive: Hercules String : 1B4F513030311B7532626C61636B04 it actually expects to receive an array of bytes with the values 1B,4F,51,30,30, etc. So what you can do is create an array of bytes and assign the byte value to each item in the array: VAR abyToSend : ARRAY[0..99] OF BYTE; END_VAR abyToSend[0] := 16#1B; // ASCII Escape character, hexadecimal representation uses 16# as prefix abyToSend[1] := 16#4F; // ASCII 'O' abyToSend[2] := 16#51; // ASCII 'Q' abyToSend[3] := 16#30; // ASCII '0' // you can do the rest yourself // maybe could be created a lot smarter, but gives you an indication how to handle this. Then with the serial communication (or TCP/IP?) you can send a message with the reference to the array (abyToSend) and the number of bytes to send (15 bytes for the string you gave as example).
Last updated: 2025-02-02
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01
Post by nmcc on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
Hey thank you for the reply dkugler. I am sorry if this seems like a stupid question. I have the use current visuvariable checkbox enabled. I can see the string names of all my visualizations. I am trying to use ladder logic to be the anser to the button press using "VisuElems.CurrentVisu := 'MainScreen';. This returns an error. Any idea what I am doing wrong or could you point me in the right direction for fixing this. Thanks,
Last updated: 2024-02-13
Post by nmcc on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
Hey thank you for the reply dkugler. I am sorry if this seems like a stupid question. I have the use current visuvariable checkbox enabled. I can see the string names of all my visualizations. I am trying to use ladder logic to be the anser to the button press using "VisuElems.CurrentVisu := 'MainScreen';. This returns an error. Any idea what I am doing wrong or could you point me in the right direction for fixing this. Thanks,
Last updated: 2024-02-13
Post by i-campbell on Publish a JSON payload via MQTT Publish (using IIot Libraries)
CODESYS Forge
talk
(Post)
your are sending as a WSTRING which is UTF16, but your receiver is interpriting as UTF8. Change the receiver to use UTF16, or better change your sender to convert to UTF8. You publish the entire storage space (SIZEOF) Instead of the number of bytes of actual text (StrLenA) try using utf8JsonData : STRING(2000); JSON.Stu.ConvertUTF16toUTF8( ADR(wsJsonData), ADR(utf8JsonData), SIZEOF(utf8JsonData) ); and change your publish to mqttPublish( mqttClient:=mqttClient, pbPayload:=ADR(utf8JsonData), udiPayloadSize:=To_UDINT(JSON.Stu.StrLenA(ADR(utr8JsonData))), wsTopicName:=topic, mQTTPublishProperties:=mqttPublishProperties );
Last updated: 2024-04-10
Post by yannickasselin on How to sort JSON object in codesys
CODESYS Forge
talk
(Post)
Just adding: sSubscriberdata := ''; Right before your memcopy should fix the extra characters. It is because your are copying 36 characters into a string which can contain more than 36 characters and there is garbage left in the extra characters. Regarding the parsing of json, I usually build a structure that mirrors the json data and use the available methods in the IIoT library to parse the data and fill the structure.
Last updated: 2024-05-08
Post by corriibme on Setting array values with JSON Utilities SL
CODESYS Forge
talk
(Post)
It turns out that you can build JSON structures without ever calling the JSONBuilder function block directly. Instead, create a pointer to JSON.JSONData and invoke the necessary methods on its dereference. The parent object has a parent index of -1 (and an index of 0). EVERY other item (including keys, values, empty arrays and sub-objects) created by the setX methods needs the index to increase by 1. Then use the JSONByteArrayWriter FB to generate your JSON string
Last updated: 2024-05-23
Post by tba123 on Script engine, git checkout, Project Environment
CODESYS Forge
talk
(Post)
Hi, I clone a git repository with VersionUpdateFlags.SilentMode, works fine But now I want to checkout a specific commit (with branch_copy command). When using the branch_copy command there is no VersionUpdateFlags and I get this annoying "Project Environment" prompt, blocking further execution of my script without user input. I already tried something like system.prompt_answers[???] = PromptResult.Cancel but I don´t know the string I need here.. The goal is to have a script that clones a repository and compiles every tag + create compiled libraries.
Last updated: 2024-06-10
Post by nano on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
i know, this is the reason for us either. PLC-Handler is to big, and only available with additional Contracts/Costs. OPC-UA is to slow for us. As described, there is a solution available, but im not allowed to post them here. i would prefer you send a message at codesys store by "have a question" or similar called. Not sure. Or, if an Codesys-Official Member allows to share that informations, i can give you the right hints.
Last updated: 2024-06-15
Post by smartcoco on Opaque NodeId in the OPC UA server
CODESYS Forge
talk
(Post)
This seems to be because when creating 'OPC UA' with 'Communication Manager', the 'IdentifierType' of 'NodeId' cannot be configured as' String 'type. This issue is not an isolated case. For this issue, CODESYS seems to have not provided guidance to users on how to proceed. We can provide feedback on this issue in the 'My Question' section of the 'CODESYS Store' to make CODESYS take it seriously.
Last updated: 2025-01-10
Post by timo on Visualisierung: Tastatur vergrößern?
CODESYS Forge
talk
(Post)
Hallo, Ich nutze den Stil White Style 3.5.16 mit ein paar farblichen Änderungen über den Stileditor. Was ich gerne machen würde, wäre die Tastaturen zu vergrößern, die sich auf dem Touchpanel öffnen wenn ein INT oder STRING eingegeben werden muss. Gibt es dafür "fertige" Variablen im Editor des Stils oder in Codesys selbst, mit dem die Größe hochskaliert werden kann? Oder muss ich jede Taste einzeln anpacken? Danke im Voraus :)
Last updated: 2025-02-21
Post by pernockham on Inheritence of struct,
CODESYS Forge
talk
(Post)
Interesting, thanks! Didnt know about ANY before, and will sure find a use-case for it. Im not sure it will help me here though, it seems to me that an ANY will not accept a string assignment? I actually think that the "ALIAS" should work, that was a hard found error. I had a fair bit of scratching my head looking for misdirected pointers before I understood what was (not) happening. I will use the work-around of individual structs instead.
Last updated: 2025-03-08
Post by imdatatas on TO_STRING operator not working for IMPLICIT ENUM
CODESYS Forge
talk
(Post)
Hi Everyone, It is a very useful feature to be able to obtain the enum value as a string with the TO_STRING operator by defining {attribute 'to_string'}. However, unfortunately the same function does not work for IMPLICIT ENUMs. I hope that {attribute 'to_string'} behavior can also work for Implicit Enumeration data types in one of the upcoming Codesys versions. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_to_string.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_datatype_implicit_enumeration.html Best regards, Imdat
Last updated: 2025-03-27
Post by marks on Siemens G120X via Ethernet/IP
CODESYS Forge
talk
(Post)
The goal is to control a Siemens G120X VFD via Ethernet/IP. The .eds is installed into the device repository. The VFD is added and is using the connection and assemblies from the eds. It appears to reach the VFD but fails to establish a connection. The status message is: Diag String: 'Adapter configured. Open all connections.' The PLC is a raspberry pi 4, running codesys target version 4.13.0.0. The development environment is CODESYS V3.5 SP21 + (64-bit). Anyone have experience with this combination? Alternately, where should I look next? Thank you, Mark
Last updated: 2025-05-06
Post by andrej on Write to File on soft PLC winV3x64
CODESYS Forge
talk
(Post)
Hello all, I would like to store some data in text file. I use the soft PLC Win V3x64, on Windows 10. I use the SysFile Library 3.5.17.0. If I store the file directly in the in the directory of the PLC i.e. in '/CODESYSControlWinV3x64/E1FA7ABE/PlcLogic/LogAU.txt' the file is correctly filled with the data. However, If I use an absolute path to a different directory no data is stored in the respective file. Despite the fact that the respective file exists and the Filehandler is correctly opened (see in picture _fdSysFHandle <> -1). // sFileName : STRING := 'LogAU.txt'; // STORES FILE IN ../CODESYSControlWinV3x64/../PlcLogic/LogAU.txt' sFileName : STRING := 'C/Temp/LogAU.txt'// DOES NOT WORK --------------------- // FILE DESCRIPTOR _fdSysFHandle := SysFile.SysFileOpen( szFile:= sFileName,am:= SysFile.AM_APPEND,pResult := ADR(_Result)); Does some have an idea where the problem is, resp. how I can get store a file in an arbitrary directory. Thanks a lot and kind regards Andreas
Last updated: 2023-10-24
Post by dtamm on How to read string from CharBufferPtr?
CODESYS Forge
talk
(Post)
I am trying to implement a mechanism to send alarm SMS. For this, I have created an Alarm Class with a Notification Action which calls a POU. This POU implements IAlarmNotifiable making it selectable in the Alarm Class configuration. IAlarmNotifiable has an Execute method which is called by the alarm class. Now, I want to extract the alarm message of the triggered alarm. The Execute method comes with a VAR_INPUT itfAlarm: AlarmManager.IAlarm which supplies a method called GetMessage. The help text says: Returns the message text, that has been configured for the alarm. The result is a pointer to the buffer, where the message text is stored The type of the result is CharBufferPtr, and at some place I read that it can be interpreted as a pointer to string. But I cannot manage to extract the alarm message, all I get are numbers. I have tried the following: psAlarmText := itfAlarm.GetMessage(__SYSTEM.TYPE_CLASS.TYPE_STRING)^; sAlarmText := TO_STRING( itfAlarm.GetMessage(__SYSTEM.TYPE_CLASS.TYPE_STRING)^ ); So how do I get access to the alarm message as clear text? (In this case, "Larm 1")
Last updated: 2024-02-21
Post by hanoues on setting date and time on CPX-E
CODESYS Forge
talk
(Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21
Post by wollvieh on Display minutes as hours & minutes
CODESYS Forge
talk
(Post)
Here a code for an Operation Counter with : days,hours,minutes,seconds as an example, maybe it points you the right direction ? FUNCTION_BLOCK OperationDayHour VAR_INPUT IN : BOOL; // Betrieb Takt : BOOL; // 1Hz Systemtakt END_VAR VAR_OUTPUT BetrTag : UDINT; // Ausgabe Betriebstage Betrstd : UDINT; // Ausgabe Betriebsstunden Betrmin : UDINT; // Ausgabe Betriebsminuten Betrsec : UDINT; // Ausgabe Betriebsekunden BetrString : STRING; // Ausgabe als String END_VAR VAR ///Erkennung Taktflanke Flanke: R_TRIG; END_VAR VAR_IN_OUT BetrsecAbsolut: UDINT; //Ein/Ausgangsvariable Betriebssekunden RETAIN !!! END_VAR Flanke(CLK:= Takt, Q=> ); (*Erkennung Taktflanke*) IF (IN AND Flanke.Q) THEN (*Sekunden hochzählen*) BetrsecAbsolut := BetrsecAbsolut + 1; END_IF Betrsec := BetrsecAbsolut MOD 60; Betrmin := ( BetrsecAbsolut / 60) MOD 60; Betrstd := ( BetrsecAbsolut / 60 / 60 ) MOD 24; BetrTag := ( BetrsecAbsolut / 60 / 60 /24 ); BetrString := RIGHT ( UDINT_TO_STRING( BetrTag + 100000),5); BetrString := CONCAT (BetrString, 'd_'); BetrString := CONCAT (BetrString,RIGHT ( UDINT_TO_STRING( Betrstd + 100000),5)); BetrString := CONCAT (BetrString, 'h_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrmin + 100),2)); BetrString := CONCAT (BetrString, 'm_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrsec + 100),2)); BetrString := CONCAT (BetrString, 's');
Last updated: 2024-05-27
Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead
CODESYS Forge
talk
(Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17