Search talk: set and reset

 
<< < 1 .. 114 115 116 117 118 .. 124 > >> (Page 116 of 124)

Post by rjwkerkhof on IIot Libraries SL --> Web Socket Client SL Pong issue CODESYS Forge talk (Post)
Dear all, I am developing a Web Socket Client in Codesys 3.5 using the Web Socket Client SL library to retrieve data from a third party. Connecting and reading works fine however after 40 seconds the connection gets interrupted by the server due to keepalive ping timeout. After discussion with third party it seems that the Web Socket Client SL library replys to the Ping request of the Web Socket server BUT does not add the "Application data" = 4 bytes in the body of the Pingframe to the Pongframe. Therefor the server does not recognize the Pongframe send by the Web Socket Client SL library and automatically disconnects. Is this a known issue with the libary or am I doing something wrong? Is there a workaround to add the 4 bytes manually to the Pongframe before replying it to the server? Thanks in advance, Roy
Last updated: 2024-04-09

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by timvh on License problem gateway CODESYS Forge talk (Post)
What we are trying to explain is that, yes CODESYS creates the software, but Epis decides how they implement it on their hardware, which runtime version they use and they decide which functionality they support. So it is always a combination of the two. What CODESYS provides is a runtime with options for e.g. visualization or softmotion. Epis could add this softmotion license as default to their controller, but if they don't then CODESYS provides another option with a single license in a "Wibu CodeMeter" container. Eventhough the feature exists, Epis has to add this "CodeMeter" software on their controller to be able to access the licenses in the container. We don't know if they did this. Then finally it depends on what type of runtime is on this controller and which license Epis is using. So if they have an OEM license (not an application based license), then most likely you will need the Softmotion license (not a number of axis). See https://store.codesys.com/en/codesys-softmotion-sl-bundle.html. But to be sure if this is supported by the Epis controller, you must ask Epis.
Last updated: 2024-04-30

Post by culius on JSON CODESYS Forge talk (Post)
Hey guys, I am trying to write a JSON. First time after login in PLC after download everthing works. But when I want to change values during runtime and try to recreate the JSON nothing happens. When forcing the xStart as an impulse i want to recreate it and see 2 as Key3 instead of 1 from the first run. Any Idea how to make this work? PROGRAM test VAR factory : JSON.JSONDataFactory; eDataFactoryError : JSON.FBF.ERROR; pJsonData : POINTER TO JSON.JSONData := factory.Create(eError => eDataFactoryError); fb_JBuilder : JSON.JSONBuilder; wsValue : WSTRING; diRootIndex, diObject1Index : DINT; iValue : INT; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; END_VAR IF xFirst THEN fb_JBuilder(pJsonData := pJsonData, diRootObj => diRootIndex); wsValue := "Value1"; fb_JBuilder.SetKeyWithValue("Key1", wsValue, diParentIndex := diRootIndex); diObject1Index := fb_JBuilder.SetKeyWithObject("Key2", diParentIndex := diRootIndex); iValue := iValue + 1 ; // -----------!!! secound run should increment key3!!!!------------ fb_JBuilder.SetKeyWithValue("Key3", iValue, diParentIndex := diObject1Index); xFirst := FALSE; END_IF jsonArrayWriter(xExecute := TRUE, pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE); Kind Regards
Last updated: 2024-04-30

Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
The hole setup is made by 3s. So its a comination of one not two. If Epis decide not to support extra licence whats then the funtion of providing an option with a single license ?? So the idee by 3s has a flod. Epis change the system to add the Stick. I send controller inc stick to Epis. On my software i can see the stick. An then you tel me i need a other license to use an license ?? Makes completly no sense. Codesys should be flexible but is not. I tried Delta. But has no HMI and has its own Codesys ?? Why ?? Then i tried Crist. The block there own system by a password. But dont know the password and cant switch it off. At the end the want me to pay for support to solve ther own made problem. So i send it al back. The extra license is adviced by 3s . Now a few month later still no working solution.
Last updated: 2024-05-01

Post by hanoues on setting date and time on CPX-E CODESYS Forge talk (Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21

Post by nikgind on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi I am trying to import a custom information model that I created using UA Modeler. I have only added two new methods and two new object types. It is possible to add the information model to the Communication Manager and the two new object types are shown in the Information Model tab. After compiling i get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://yourorganisation.org/Bsp_3.1/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. The error message does not make sense to me. Should it not be “Probably the information model from 15/12/2023 is missing in the information model repository”? Anyway I have installed the information model from 15/12/2023 but not from 15/09/2021. Which makes the error message even stranger.
Last updated: 2024-06-09

Post by rmaas on Strange Behavior on Raspberry Pi CODESYS Forge talk (Post)
Hello, what you are seeing is not strange behavior. The problem is that everyting is happening in the same program cycle. After the variable Stepnumber is changed from 10 to 20 for example then you want the program to wait with the next EQ until the next program cycle. Else every EQ will be be true because in every line the variable Stepnumber is increased. When the program arrives (still in the same cycle) at the line with the timer, the Stepnumber has been increased to 30 in the meantime and the timer will allway be ON because even though the variable is written to 10 in this line in the next cycle it starts with 10 and will be 30 again before reaching the timer in line 8. Not very good at explaining stuff but i hope you get the problem. See screenshot below for an example of one way you could solve this...
Last updated: 2024-06-18

Post by dekelec on Codesys 2.3 & Peak PCAN CODESYS Forge talk (Post)
I use Peak USB adapter daily to download from CoDeSys 2.3 and 3.5 to IFM, EPEC and other controllers. The process: - First you need to install the appropriate driver. Link: https://www.peak-system.com/Drivers.523.0.html?&L=1 - Restart the computer - Start the CoDeSys application - Change the name of the adapter in Communication parameters, as mentioned in previous comment. Write the name exactly as written "Peak_USB", as it could also be case sensitive (defines which .dll file to use). If this doesn't work I would contact the vendor of the controller to find out the procedure. In the attachment I've added a FAQ document from IFM regarding using PCAN USB. P.S. I've noticed in your picture of communication parameters a channel via TCP/IP is mentioned. In this case a USB to CAN connection is not being used. First you should change the channel/gateway to connect via CANbus or connect using an Ethernet cable.
Last updated: 2024-07-09

Post by tyronnosaurus on ReceiveWatchdog FB not working on J1939 P2P PGNs CODESYS Forge talk (Post)
Hi guys. I've got a device that sends a status message over J1939 and a PLC running Codesys to receive it. This message uses a P2P PGN (as opposed to a broadcast PGN). Codesys can only read it if I mark the J1939_ECU as "Local" (see screenshot 1). The message is received correctly, that is not the problem. The problem is detecting if the message stops being received. Local ECUs have no Watchdog checkbox to detect if the message has been received in the last X seconds. In order to implement a watchdog, I've used a ReceiveWatchdog FB. The same code works well for any non-P2P message, but doesn't work for this particular P2P message I'm trying to monitor. Even if I physically disconnect the device, ReceiveWatchdog.xBusy stays True, and ReceiveWatchdog.xError never triggers due to a timeout error. Is there any caveat in the ReceiveWatchdog FB that makes it unable to monitor P2P PGNs in Local J1939_ECUs?
Last updated: 2024-07-11

Post by berto on Opening PDF in Web Browser in Target Visu HMI CODESYS Forge talk (Post)
Hi everybody, I've been facing problems with the PDF visualization in Web Browser. I am trying to open a pdf file called 'sample.pdf' which I manually saved inside PlcLogic/visu folder. I am setting the web browser URL as: 'http://127.0.0.1:8080/sample.pdf' but I get 'refused connection'. I got a similar error trying to open https sites and I discovered that I can only open http websites. Opening 'http://de.wikipedia.org' everything works fine. I also tried to check using code whether the sample.pdf is present in the directory. Unfortunately, when I try to read directories of 'PlcLogic' I get file FILE_OPERATION_DENIED (I am using File.DirList). I would like to be able to open PDF files in web browser. Possibly to move new PDF files in the folder as my customer wants to display different pdf manuals on the hmi. Here you find some screenshots and my .project. I am using Codesys 3.5.19.70. Best regards, Berto
Last updated: 2024-07-11

Post by denkihitsuji on Content update through Data URI on Web Brower on Visualization Toolbox CODESYS Forge talk (Post)
Objective: I want to dynamically update the content with strings and JPEG images received from a TCP/IP socket. For this purpose, I am exploring the possibility of utilizing the Web Browser feature of the Visualization toolbox. Example: In a standard web browser, entering data:text/plain;charset=utf-8;base64,SGVsbG8gc3RyYW5nZXI= in the URL window will display "Hello stranger" on the webpage. Issue: When attempting to use this method in the Web Browser of the Visualization toolbox, the content does not display as expected. Instead, it shows the error:'Navigation to the webpage was canceled.'. Request: I seek guidance on how to resolve this issue so that the Web Browser in the Visualization toolbox correctly interprets and displays the data URI content. Alternative Solution Welcomed: Or, if it is possible to directly use Codesys Structured Text (ST) variables within an HTML page, this approach would also meet my requirements. Thank you for your attention.
Last updated: 2024-07-30

Post by jmfernandes on OpenDir always in error CODESYS Forge talk (Post)
Hello I'm trying to use DirOpen to access a directory where then I can read/list the files inside. But I can't list any files because DirOpen.xError is always true. In eError the message is this: " ERROR_UNKNOWN Local library error ID (0: no error; 5101: time out)**** " I have in the file explorer the path 'C:\CodesysTest\Aluminium' and to make sure I also created in the plc a folder to 'prj/Recipes/Aluminium'. I tried using the different paths, but in both it happens the same thing.Inside the folder Aluminium there is two csv files, that I want to list. I added in the library manager CAA Files and CAA Types. I am using the example of https://content.helpme-codesys.com/en/libs/CAA%20File/Current/Examples.html#directory but not matter what I do, I can't get the list the names of the files. What am I missing?
Last updated: 2024-07-31

Post by sturmghost on Mimic behavior of the visualization button element with a custom button CODESYS Forge talk (Post)
Im wondering how Codesys is doing the mouse event capturing with their visualization button element? If you add such a button without configuring any input configuration event (like OnMouseDown) or button state variable and then click on the button, the button changes to the visual pressed state and back if you release the button (so they must react to an OnMouseDown event). But how? If I try to mimic this behavior with my custom button visualization element (like a basic rectangle) I need to use an input configuration event to change the color of the button (to make it look like the button was pressed on OnMouseDown event). When I try to add this button via a Frame-Element to my main visualization page I'm unable to use an input configuration event on the Frame-Element because the input configuration event on the button element won't be evaluated anymore (it seems like you can't stack input fields, e.g. invisible input elements, onto each other). Hence the button is not shown pressed anymore. How they do it?
Last updated: 2024-08-04

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by rossanoparis on Clarifications regarding the appropriate runtime system to use CODESYS Forge talk (Post)
Hallo all I would appreciate some clarifications regarding the appropriate runtime system to use. I've been using 'KUNBUS CPUs' and 'CODESYS Control for Raspberry Pi MC SL' for the last 4 years. Recently, there have been some changes in the CODESYS licensing policy. [ https://store.codesys.com/en/howto_applicationbasedlicenses ] My questions are mainly two: 1) If I need to start a new project using 'KUNBUS CPUs', which is the correct runtime system to use. 2) Old projects built using 'CODESYS Control for Raspberry Pi MC SL' should be updated to another RT system? Current RT systems ... a)CODESYS Control for Raspberry Pi MC SL b)CODESYS Control for Linux ARM SL c)CODESYS Virtual Control SL May I count on receiving an explanation to understand the differences among the runtime systems listed above? A detailed and well-organized answer would be greatly appreciated. Kind regards Rossano
Last updated: 2024-09-23

Post by lbartik on J1939 TX/RX PDU1 CODESYS Forge talk (Post)
Is it possible to transmit a PDU1 PGN using the J1939 manager and local device? What if I need to transmit a PGN RQST via 0xEA00 (PGN 59904)? How would I do this P2P (Destination < 0xFF) or broadcast (Destination 0xFF)? I don't think this is possible for any destination type. I don't think it's possible to receive broadcast PDU1 messages either. For example, an address claim PGN 60928 (0x18EEFF80) is addressed to all nodes (0xFF) and not any specific local device so it will be filtered out. These are major oversights in the IoDrvJ1939 library to not support every PDU1 RX/TX scenario. IoDrvJ1939 supported scenario: 1. Receive (RX) PDU1 (P2P) destination-specific (PDU-specific < 255) to local device with matching address IoDrvJ1939 unsupported scenarios: 1. Receive (RX) PDU1 (P2P) global (PDU-specific = 255) 2. Transmit (TX) PDU1 (P2P) global (PDU-specific = 255) 3. Transmit (TX) PDU1 (P2P) destination-specific (PDU-specific < 255)
Last updated: 2024-09-23

Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
Hi, We have a machine running Codesys on a Windows IPC (CODESYS Control Win v3 - x64). When we hard shutdown the machine, the code on the PLC sometimes becomes "corrupted" after a power on (When trying to login to the PLC, we get the message "The application 'Application' does not exist on device."). I've noticed these errors in the logs, but I'm not sure what to make of them. We are not using any RETAIN variables in our code, although I'm not sure about referenced librairies. (we are using the persistence manager). I'm pretty sure that not doing a graceful shutdown is the root cause of this. This being said, what is the proper way of doing a graceful shutdown? Is putting the Codesys application in "stop" sufficient? I know how to implement this, so if it works then it would be a quick fix. However, I think we need to add a UPS, which would detect power loss and inform the PLC that it needs to initiate its shutdown, and then the PLC would shutdown gracefully. Any help with this will be greatly appreciated :)
Last updated: 2024-10-03

Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
This explanation aligns with the issues we’re experiencing with our machines. The scenario I described is happening with one of them (let’s call it Machine A). This machine is identical to another one (Machine B), except for some custom code that facilitates communication with an external Beckhoff PLC for MES integration in the production line. Machine B has been powered on and off daily for at least three months and has never had this problem. Given that, I highly doubt the MES custom code is the cause of the code corruption. This being said, your explanation does seem plausible. However, if faulty EtherCAT cables were the issue, why wouldn't the error occur during normal operation? Why would bad cables only cause problems during a hard shutdown? One last question: When you encountered this behavior, did you see a similar error in your logs? i.e, an "AccessViolation" exception in the EtherCAT Task?
Last updated: 2024-10-03

Post by raghusingh77 on Get $100 EVERY TIME USE THIS COUPON CODE OF ACU934948 TEMU CODESYS Forge talk (Post)
Temu has quickly established itself as a leading online shopping platform, offering customers a wide array of products at unbeatable prices. As we move through 2024, shoppers can take advantage of exciting promotions, including the $100 off coupon code [ACU934948]. This article will guide you through how to maximize your savings with this code and other fantastic offers available on Temu. Exclusive Discounts for New Users For those who are new to Temu, the platform offers an enticing 30% discount on orders over $39. By using the coupon code [ACU934948], first-time users can enjoy this immediate savings opportunity. Additionally, new users can benefit from a special promotion that provides up to 75% off their first purchase. This makes it an ideal time for newcomers to explore Temu's extensive inventory while enjoying significant discounts. Massive October Promotions October 2024 is shaping up to be a month filled with incredible deals on Temu. Shoppers can access discounts of up to 90% off select items when using the coupon code [ACU934948]. This promotion is part of Temu's strategy to attract both new and returning customers during the busy shopping season. Flat Discounts and Bundle Offers The $100 off coupon code [ACU934948] stands out as a valuable offer, providing a flat discount that enhances the overall value of your purchases. This coupon is applicable not only for new users but also for existing customers, ensuring that everyone can benefit from substantial savings. Furthermore, Temu has introduced bundle offers that combine this $100 discount with additional promotions, allowing customers to save up to 70% on select products. Temu Rewards Program for Loyal Customers Temu values its loyal customers through its comprehensive Rewards Program, which offers exclusive deals and discounts. By using the coupon code [ACU934948], existing customers can enjoy additional benefits, including potential cash-back offers. For example, eligible purchases may yield up to 25% cash back, making it even more rewarding to shop at Temu. How to Redeem Your Coupons Using Temu's coupon codes is straightforward: Browse Products: Start by exploring Temu’s extensive range of items. Add to Cart: Once you find what you like, add it to your shopping cart. Apply the Coupon Code: At checkout, enter the coupon code [ACU934948] in the designated field and click "Apply." Complete Your Purchase: Review your discounted total before finalizing your order. Tips for Maximizing Savings Redeem Temu Coupon Code [ACU934948]. TEMU COUPON $100 OFF [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS [ACU934948] TEMU COUPON $100 OFF FIRST ORDER [ACU934948] TEMU COUPON $100 OFF REDDIT [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS REDDIT [ACU934948] TEMU COUPON $100 OFF NEW USER [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS 2024 [ACU934948] TEMU COUPON $100 OFF CODE [ACU934948] TEMU COUPON $100 OFF FIRST ORDER FREE SHIPPING [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FREE SHIPPING USA [ACU934948] TEMU COUPON $100 OFF HOW DOES IT WORK [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS CANADA [ACU934948] TEMU COUPON $100 OFF 2024 [ACU934948] TEMU COUPON $100 OFF FOR NEW CUSTOMERS [ACU934948] TEMU COUPON $100 OFF CANADA [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FIRST ORDER [ACU934948] TEMU 100 OFF COUPON BUNDLE [ACU934948] 100 COUPON CODES [ACU934948] 1 BUCKS TO PHP [ACU934948] IS THERE A COUPON IN THE PHILIPPINES [ACU934948] 100 BUCKS TO PHP [ACU934948] TEMU $100 OFF COUPON [ACU934948] TEMU $100 OFF CODE [ACU934948] TEMU 100 VALUE COUPON BUNDLE [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FREE SHIPPING [ACU934948] TEMU 100 OFF COUPON CODE LEGIT [ACU934948] TEMU 100 OFF COUPON CODE REDDIT [ACU934948] TEMU 100 OFF COUPON CODE FOR EXISTING USERS [ACU934948] TEMU 100 OFF COUPON CODE UK [ACU934948] TEMU COUPON CODE $100 OFF FREE SHIPPING [ACU934948] TEMU COUPON CODES 100 PERCENT OFF [ACU934948] WHAT IS A HIGH COUPON RATE [ACU934948] HOW TO CALCULATE COUPON RATE WITHOUT COUPON PAYMENT [ACU934948] WHAT IS THE COUPON RATE [ACU934948] HOW TO CALCULATE COUPON VALUE [ACU934948] USING COUPONS AND REBATES TO LOWER THE PRICE OF AN ITEM IS AN EXAMPLE OF [ACU934948] TEMU 100 DOLLAR OFF COUPON [ACU934948] DOMINOS COUPON CODE 100 OFF [ACU934948] DOMINO'S 100 RS OFF COUPON CODE [ACU934948] TEMU COUPON $100 OFF EXISTING CUSTOMERS [ACU934948] WHAT IS 10 OFF 100 DOLLARS [ACU934948] 100 OFF PROMO CODE [ACU934948] 1 CASHBACK ON 100 DOLLARS [ACU934948] IS TEMU 100 OFF COUPON LEGIT [ACU934948] TEMU COUPON $100 OFF [ACU934948] TEMU COUPON $100 OFF LEGIT [ACU934948] Temu Coupon Code $100 OFF [ACU934948] Stacking Discounts: While you cannot apply multiple coupon codes in one transaction, ensure you're using the most beneficial code available. Lightning Deals: Keep an eye out for limited-time "Lightning Deals," which often feature discounts of up to 80%. Free Shipping Offers: Temu provides free standard shipping on all orders, enhancing the value of your purchases. Conclusion With its competitive pricing and generous promotional offers like the $100 off coupon code [ACU934948], Temu is an excellent choice for savvy shoppers looking for great deals. Whether you are a new user eager to explore or an existing customer ready to reap rewards, Temu provides ample opportunities to save significantly on your purchases. Don't miss out—redeem your coupons today and enjoy an exceptional shopping experience filled with incredible value
Last updated: 2024-10-26

Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3 CODESYS Forge talk (Post)
Some findings on this issue: PEAK CAN Driver is the same as in every PCI card from PEAK. I updated the inf file. Here are my steps: 1. Include right VendorID into the *.inf file 2. Disable Windows driver check (Disable WHQL check). This you need because 3S driver is not certified. You will find steps via google or ask chatgpt :) 3. Select: Select driver from a list and navigate to the folder. Say yes to install an uncertified driver. 4. Driver installed and device without errors I did the same with CAN Card from ESD, but here you dont need to include the vendor ID. In ANY CASE it was not successful. The RTIOwdmgeneric is not available in Codesys or anyhow accassable :( I wonder that it fails in two cases, two suppliers, two driver in the same way. How can RTIOwdmgeneric implemented into the project?
Last updated: 6 days ago

<< < 1 .. 114 115 116 117 118 .. 124 > >> (Page 116 of 124)