Post by jantje on Setting up the "Visual Studio Code" debugging environment (using .NET debugging) for use with the ScriptEngine API in Python.
CODESYS Forge
talk
(Post)
Hi Till, Sadly I did not get any feedback on this and was not able to get it to work using Visual Studio Code. I believe I have used a Codesys environment to get something up, but I cant remember any specifics, its too long ago. Good luck with it! Kind regards, Jan
Last updated: 2023-10-02
Post by ofey on Device parameter - ‘ModbusTCP Configuration’
CODESYS Forge
talk
(Post)
Hi! Do anybody know how I can add and enable the parameter 'Default Modbus TCP slave' on a device? I am currently writing a program where the PLC shall be set up as a Modbus TCP client, but I dont know how to add parameters to devices in codesys. I'm pretty new to the codesys environment. The picture in the attachment is on a similar PLC project where I have not written the code. my goal is to add this parameter in another project.
Last updated: 2023-10-04
Post by sukrit on What licenses are required for runtime on raspberry pi cm4
CODESYS Forge
talk
(Post)
We have developed a project for 2 servo motors using raspberry pi computemodule 4 on ethercat master. we are using web visualization for display different screens. project is running well in demo. we want to implement it in production envoirment. being new still wondering which licences i need. Can We get this information in codesys devlopment software. code size is approx 5 mb, 1 instance of etharcat master and aproox 100 variables in visaualization.
Last updated: 2023-10-17
Post by eschwellinger on Persistence Manager Backup
CODESYS Forge
talk
(Post)
you need at them moment a download once (for the configuration files generated including addresses) then stop the plc - exchange the persistence file ( without the config file) This will be improved to 3.5.18.6 and 3.5.20.0. (possible then to generate offline bootproject including full persistenmanager files) - this is if you have not 100% the same bootapplication on the devices. In case you copy the whole Application (PLCLogic) directory it should work out of the box - but only with 100% same bootprojects as mentioned above. By the CODESYS Automation Server would help solve this too.
Last updated: 2023-10-19
Post by nathant on Can't open online view of FB instance from code editor, only from Device/POU windows
CODESYS Forge
talk
(Post)
Hello, The title pretty much says it all. When trying to open a FB from the CFC/Ladder/SFC editors while online, the FB does not open in an online view of that specific instance. Instead, it opens an offline view with '???' shown for the value of any variable. This makes debugging extremely cumbersome, as I have to find each FB in the POU window and select the specific instance I am trying to view. Anyone know the cause/solution for this? Thanks.
Last updated: 2023-11-08
Post by song on How to convert a standard robot program into an excutive list when a robot runs?
CODESYS Forge
talk
(Post)
Dear Sir, I'd like to learn and try to make robot based on Codesys, is there a FB block or other ways to convert a standard robot program into an excutive list? how codesys explain the robot command instructions on HMI, just like the SMC_NCDecoder used to convert CNC program into a list of SMC_GEOINFO object. Thanks very much! Peter Yan
Last updated: 2023-11-25
Post by alink on Visu - changing auto-logout time
CODESYS Forge
talk
(Post)
Hello is there a chance to set with a visu input the auto-logout time? At the moment, it is a fix value set in visu-manager. But for individual configurating of passwort policies I create a visu-dialog to set policies and there for an option to set auto-logout-time. But till now, I haven't found a solution. Maybe someone has an idea? Thanks
Last updated: 2023-11-30
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01
Post by snhatton on Running webvisu with Codesys Control Win V3 in Simulation Mode
CODESYS Forge
talk
(Post)
Yes, you can use the CODESYS ControlWin V3 Soft PLC. However, if simulation is enabled on the device this will disable all communication, so you need to turn off simulation to view the visualization in a web browser. In simulation mode, all IO and communication is disabled for standalone testing. In addition, make sure to set the start visualization in the WebVisu object in the application tree. I hope this helps!
Last updated: 2023-12-04
Post by zatalian on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05
CODESYS Forge
talk
(Post)
There seem to be problems with the latest version of raspberry pi os 64bit (I used the lite version). The codesys control runtime crashes after a few seconds. The same runtime works on the raspberry pi image from 2023-10-10 When starting the runtime from the commandline, i get the following error: ooops... this runtime was build for RASPBERRYPI. Hardware version or firmware version not supported! (and yes, I'm running this on a raspberry pi :-)
Last updated: 2023-12-11
Post by mputaggio on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
Hello, We encountered the same issues on both recipe library versions 4.2.0.0 and the newest 4.3.0.0. The Arrays of structs get saved correctly but loading them restores only some indexes, while others get lost or completely wrong. We have been using the same recipes for the last two years on recipe manager vers. 3.5.17 withoud issues. There also seems to be a different behaviour in vers. 4.3.0.0 but it's still incorrectly loading the recipes. Did you find any workaround or solution? Codesys version used: 3.5.19.50
Last updated: 2023-12-15
Post by nathant on Some visualization objects disappear when user is logged in?
CODESYS Forge
talk
(Post)
I am deploying a webvisu on Codesys 3.5 SP 19.2 with legacy user management. I noticed that when a user logs in, some text and a rectangle I have (for aesthetics) both disappear. I made sure that none of the objects in question are linked to a state variable. Anyone know the cause/solution to this? Nothing crucial to the machine's function is lost, but it is a little annoying.
Last updated: 2023-12-15
Post by simover on TCP/IP client
CODESYS Forge
talk
(Post)
I want to send a string to a tics TCP/IP server. I got i working with the Net Base lib. for communication good with this tcis i need to by array of byte I want to include a string in the third position of the array TCIS_Send[1] :=254; //this valus is fix for evry communication TCIS_Send[2] :=80; //this valus is fix for evry communication TCIS_Send[3] := ; here I put my and my string is lik this 5806509-DRAP10#AB#3452302073 TCIS_Send[4] :=252; //this valus is fix for evry communication
Last updated: 2023-12-18
Post by svn123 on Can V3.5.19 and V2.3.9 be installed on same Windows10 PC without affecting each other?
CODESYS Forge
talk
(Post)
Hi All, Seasons Greetings! I have Codesys V3.5.19 patch 5 installed on a Windows 10 PC. I have received a program which is for Codesys V2.3.9. First I tried to convert it but had many conversion errors. I am wondering if it is possible to install Codesys V2.3.9 on same PC without affecting the V2.5.19 installations. Is this possible? SVN123
Last updated: 2023-12-28
Post by andrax on Mux I2C
CODESYS Forge
talk
(Post)
the TCA9548a does not work in Codesys. In Pyton this is only queried once and in Codesys cyclically. Of course you can also insert a terminating resistor in each port, then you should have no problems. I use this one: https://botland.de/8-bit-multiplexer/12723-qwiic-mux-breakout-8-kanal-modul-mit-i2c-multiplexer-tca9548a-sparkfun-bob-16784-5904422341428.html You can simply set the library to the latest version. You do not need Oscat. Do you need an example project for the BMP280?
Last updated: 2024-01-02
Post by andrax on Mux I2C
CODESYS Forge
talk
(Post)
the TCA9548a does not work in Codesys. In Pyton this is only queried once and in Codesys cyclically. Of course you can also insert a terminating resistor in each port, then you should have no problems. I use this one: https://botland.de/8-bit-multiplexer/12723-qwiic-mux-breakout-8-kanal-modul-mit-i2c-multiplexer-tca9548a-sparkfun-bob-16784-5904422341428.html You can simply set the library to the latest version. You do not need Oscat. Do you need an example project for the BMP280?
Last updated: 2024-01-02
Post by usacodesysuser on How to connect serial devices ?
CODESYS Forge
talk
(Post)
@eschwellinger do you have any examples of using a USB barcode scanner? I have read through the forums here and I am unable to find how to get the barcode data to populate in a text field without having to first click into the text field to activate it. Is there a library that allows you to access the barcode data? I am really new to this in general any help is greatly appreciated, hopefully you have a pretty clear example
Last updated: 2024-01-06
Post by eschwellinger on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
we need some logfiles from the edge gateway /etc/Gateway.cfg [CmpLog] CmpEdgeGateway.Filter=0xFFFFFFFF Logger.0.Name=/tmp/codesysedge.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=100000 Logger.0.MaxFileSize=5000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC and does the scan via Automation Server show the plc?
Last updated: 2024-01-09
Post by rodberna on Library for arrays
CODESYS Forge
talk
(Post)
Hi, I'm creating a program where I need to handle arrays, like: - Declare lenght variable arrays - [array(1..var) of "sometype"]. This is not possible in pure codesys, right? - Know array lenght, min, max, avg values in runtime - append/delete itens in an array - and so on Is there a library know for this in codesys. Is it possible to build our own libraries using some high level language like python or java script?
Last updated: 2024-01-10
Post by wehling-h on PI Input value
CODESYS Forge
talk
(Post)
Hi geoweil, have you tried to save changed values to remanent area or using a VAR RETAIN? After restart you have to initialize Counter with last remanent value. Depending on changes per cycle and the possibilitiy of your control unit to write remanent storage. Otherwise you need a buffering system to ensure save backup of last PI_Counter value. May you could read this Thread to get further help: https://forge.codesys.com/forge/talk/Engineering/thread/31e1c8349e/#bf48
Last updated: 2024-01-12
Post by timvh on Minimum system requirements for codesys control standard S
CODESYS Forge
talk
(Post)
It depends on your application which CPU speed and RAM size you need. If you think the Control Standard S license is sufficient then my guess is that your selected PC has no problem running your application. There are no more "hardware" based single licenses available anymore, only application based licenses. So this "Raspberry Pi" restriction for home automation is not applicable anymore. For more information see: https://store.codesys.com/en/howto_applicationbasedlicenses
Last updated: 2024-01-14
Post by jaspergain on Access to the path *** is denied
CODESYS Forge
talk
(Post)
Hello, Recently I upgraded to 3.5.19.50 and have been having errors/issues when doing a download/online change. The message as seen in the attachment pops up. The file in the path is different every time. However when I login again afterwards all works fine. This issue does not happen on older versions. Any clue what the issue could be? I did an reinstall/repair but the issue reappeared again... Thanks in advance!
Last updated: 2024-01-25
Post by rpostwvu on Shared Memory Access Issues
CODESYS Forge
talk
(Post)
I got the shared memory example. I'm pretty sure I'm successfully created a memory space, CreateResult returns 18. szName:='CodesysDataShare'; hShm := SysSharedMemoryCreate(szName, 0, ADR(uxiSize), ADR(CreateResult)); I'm trying to access this memory with a C# application, but I get "Unable to Find Specified File". I suspect that Codesys and/or Visual Studio code alters the name I choose? Being in Windows, I cant find a way to see the mapped memory list. ~~~ using (var mmfRead = MemoryMappedFile.OpenExisting("CodesysDataShare",MemoryMappedFileRights.ReadWrite)) ~~~
Last updated: 2024-01-29
Post by matt-s on HMI Pushbutton/Move Instruction
CODESYS Forge
talk
(Post)
I have not gotten to the bottom of this yet no. I have double check that the variables are correct linked. When online with the program I can see the button and rung going true for the move instruction, yet it does not change. Forcing the bit in the program does change the value in Groov View. I am kind of at a loss here, especially since the other POU(For the pumps) does the same thing fine.
Last updated: 2024-02-02
Post by jshirazi on Restore license on Raspberry Pi
CODESYS Forge
talk
(Post)
Hi, I recently got a license for Raspberry Pi, after license activation I made a backup copy of "CMLicenseNew.WibuCmRaU" file to a safe place. Things got complicated and I tried to downgrade OS for some reason after that I tried several times/ways to restore my license with no luck. the specifications are as follows: Raspberry Pi 4 Model B Rev 1.1 codesyscontrol 4.10.0.0 SDK 3.5.19.30 Logs: **** ERROR: CodeMWriteLicenseFile: 'CMLicenseNew.WibuCmRaU' failed: Container not found or Server dose not support .... So if someone know a solution for this please kindly help me. Regards
Last updated: 2024-02-03