Post by bbmussatto on Connetion with Topcon Opus B3 ECO Full display CODESYS Forge talk (Post)
I have a Topcon Opus B3 ECO Full display and i wanna program it with codesys, but i cant connect it to the display. After creating a new project, i choose the device "Opus B3-B4-B6-3.5.19.50" that is already available in my version of codesys, but i think the problem is that my version of codesys or something else is not the same as the codesys runtime version running on my display. Can anyone tell me how i can see the codesys runtime version on my display? i tried looking in the settings (Daemon > CDS) on the display, but all i see is "N/A" for "Customer Number", "Customer Part Number" and "Customer Serial Number". Can anyone help me make this connection?
Last updated: 2025-10-07

Post by ouzago on ERROR C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
When I created a new project in CODESYS using the "Standard Project" template and then added a Visualization, I was receiving the C0138 error during compilation. This issue persisted even with a new, completely empty project. A Quick and Effective Solution (My Method): After many attempts, I solved the problem as follows: From the File -> New Project menu, I selected the "HMI Project" template directly, instead of the "Standard Project" template. After creating the project with this template, I added my POUs, Tasks, and programs (e.g., Ladder, ST). Using this method, the project compiled successfully without any errors. So, my question is: are there any other solutions besides this method?
Last updated: 2025-10-07

Post by vformanek on irq-set piority is not working in plc-shell CODESYS Forge talk (Post)
Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html But the irq-set is not changing the priority. See the image bellow....
Last updated: 2024-01-05

Post by toby on Ethercat Servo Setup CODESYS Forge talk (Post)
Hi everyone, so a little update to this, I've come back to this project in the new year, and got it working. Yeah!, However, now with the new licensing setup, I need a new SoftMotion license, but it doesn't seem to be compatible with the previous Raspberry Pi SL license. Has anyone had any luck with Raspberry Pi and SoftMotion_Lite? Specifically the licensing of such? My customers new installation needs to be rebooted every 30min which is causing headaches! Another option is to not use the SoftMotion function blocks, and control the EtherCat amplifier directly, but I'm not sure how to do so. Does anyone have a specific example project of how to control a servo without the use of the SoftMotion function blocks? Thanks everyone for any assistance rendered. It's very much appreciated! Toby
Last updated: 2024-01-10

Post by tokamk on Dynamic setting of the modbus tcp/ip slave ip address CODESYS Forge talk (Post)
Hello, I'm working on a project which includes Panel-PC which communicates with a PLC through Modbus TCP/IP. On the PLC I have a CODESYS code which has Modbus slave objects. The Modbus slave objects have to have manually set IP address in order for them to work properly and the Ip address has to be the PC-Panels's IP. This project is going to a customer and they're using their own IP address realm. So, my question is that is it possible to configure these slaves in some other way, so that the customer doesn't need to modify the CODESYS project? I was thinking that would it be possible to set the IP address of these slaves from external source?
Last updated: 2024-02-15

Post by phoward131 on Text List Fallback Value CODESYS Forge talk (Post)
I am relatively new to Codesys and I'm trying to develop an HMI that displays what mode a particular device is in based on an integer value. I am currently using dynamic texts with a text list which works fine but I am looking for a way to display a particular string (ie 'Unknown') when the index doesn't match any of of the indices in the text list. I can enter 'Unknown' in the text property of the text field element which works as expected but it displays the single quotes on the visualization. How can I escape these quotes to simply display the word Unknown? Thanks!
Last updated: 2024-03-22

Post by fajean on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
4.11 appears to solve the problem. Thanks for your help. I had first installed the 64-bit version of RPiOS, but looking at various posts and the product's page on the store which only lists 32-bit compatibility, I downgraded to the 32-bit version. I did this before trying 4.11, and it did not solve the problem. Thus my working system is 32-bit, and I am wondering if I can go back to 64-bit or not. An 64-bit OS is not listed as compatible on the store's web page, but when installing there actually is a 64-bit version listed (automatically chosen when installing on 64-bit, but otherwise greyed out). Is 64-bit supported and the website is out-of-date, or is that some kind of work-in-progress?
Last updated: 2024-06-13

Post by etalp on Eaton XC303 firmware update via USB CODESYS Forge talk (Post)
Hi, I'm struggling with updating my xc303 to firmware 3.5.17. It is possible only via USB port. I've installed proper update files on the USB then plug it into the PLC's USB port and restarted the device. Shortly after LED's on the PLC started to blink, so updating process has started. But after 10 minutes the PLC LED turned off and after all I could't serach for this PLC in Codesys, but could ping it. Could someone eplain to me proper procedure of updating the fimrware in XC303 via USB? Is it neccesary to STOP the PLC switch after pluging the USB?
Last updated: 2025-10-15

Post by pernockham on Images not shown in webvisu CODESYS Forge talk (Post)
Two issues. Ive been struggling to get the user management the way I want it. I want to protect the device from unauthorized upload/download, but I do not want login requirement on webvisu. The combination that seems to work is to use "runtime device user management" while keeping the visu user management in "legacy mode"? Initially this seemed to work, but now images are not loaded when using direct access, while they are still shown if I access the webpage via Automation server. Im guessing its connected to the authorization changes? Anyone able to help out? Thanks Also, I read that legacy mode should be avoided, is it possible to use "runtime based visu user management" while keeping direct access to the webpage without login. System is a "Control for linux SL, version 4.20.0.0" Per
Last updated: 2026-04-10

Post by jroddball79 on PM556-TP-ETH β€” How to change IP address without overwriting the PLC program? CODESYS Forge talk (Post)
We have checked open ports. SSH (22) and HTTP (80) are not reachable. The only open ports are: 502 (Modbus TCP β€” used for lighting control) 1200 (CODESYS runtime) 1201 (CODESYS runtime) We can connect via Automation Builder using the current IP, but we don't have the original project source β€” only an empty project. This is why we are afraid of doing a full download, as it would overwrite the running application. Is there any way to change the IP through the CODESYS runtime protocol on ports 1200/1201 without affecting the running program?"
Last updated: 2026-05-20

Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
This explanation aligns with the issues we’re experiencing with our machines. The scenario I described is happening with one of them (let’s call it Machine A). This machine is identical to another one (Machine B), except for some custom code that facilitates communication with an external Beckhoff PLC for MES integration in the production line. Machine B has been powered on and off daily for at least three months and has never had this problem. Given that, I highly doubt the MES custom code is the cause of the code corruption. This being said, your explanation does seem plausible. However, if faulty EtherCAT cables were the issue, why wouldn't the error occur during normal operation? Why would bad cables only cause problems during a hard shutdown? One last question: When you encountered this behavior, did you see a similar error in your logs? i.e, an "AccessViolation" exception in the EtherCAT Task?
Last updated: 2024-10-03

Post by hyys12 on Help understanding analog in-/outputs CODESYS Forge talk (Post)
Hello. I am currently working on a WAGO PLC, where I am trying to wrap my head around how the analog inputs and outputs work in codesys. I have looked far and wide on the internet, for a general introduction to the whole concept, but I have not had any luck with finding anything that helped me understand it better. The whole goal is for me to be able to read an analog input from a temperature sensor, as well as using an analog output, to control a frequency inverter. I know these have nothing to do with each other, but that is all I have on hand right now. I am trying to program this using Ladder Diagram. The only thing is, that every video/guide I have seen/read using LD, just adds a whole lot of function blocks, to do all kinds of stuff they don't explain. My general question is, how would one go ahead and read the analog input, as well as transmit an analog output? Is there some kind of specific function block I would have to use for this, or some great video I can watch, to understand the inner workings. Is it somehow possible to see the values the PLC recieved/sends? Regards.
Last updated: 2024-12-11

Post by zoronoa on J1939.ReceiveWatchdog & J1939.ReceiveParameterGroup CODESYS Forge talk (Post)
Hi, I'm trying to monitor a specific PGN which I have it sending a pulse every 500mS Problem: Using the Watchdog for the ECU does not really help me as I have multiple instances with separate PGNs, if a PGN goes ghost, the ECU watchdog won't be flagged as the others will be running. I found the J1939.ReceiveWatchdog & J1939.ReceiveParameterGroup function blocks and they seem like a good solution for my problem, I just can't get them to work from my understanding you just build the J1939.ReceiveParameterGroup once and then connect it's output to the J1939.ReceiveWatchdog, here's my CODE for the setup HEARTBEAT_TIMER(IN:= TRUE, PT:= T#1000MS); //turn-on delay because of initialization race IF HEARTBEAT_TIMER.Q= TRUE THEN Glob_Var.DisplayReceive.xExecute:= TRUE; Glob_Var.DisplayReceive.itfECU:= Valve_X; Glob_Var.DisplayReceive.dwPGN:= 65511; Glob_Var.DisplayWatchdog.xEnable:= TRUE; Glob_Var.DisplayWatchdog.itfParameterGroup:= Glob_Var.DisplayReceive.itfParameterGroup; Glob_Var.DisplayWatchdog.tTimeout:= T#1500MS; END_IF Notes: Glob_Var.DisplayReceive is of type J1939.ReceiveParameterGroup Glob_Var.DisplayWatchdog is of type J1939.ReceiveWatchdog The above code is done once and not cyclically I'm monitoring Glob_Var.DisplayWatchdog.xError cyclically
Last updated: 2024-03-13

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Hi CoDeSys support forum, hope that this is the correct place to ask this. Might be double as i am new to Codesys and dont know all terminology. I am trying to test Codesys with a virtual plc on a raspberry pi 5. Already figured that i need Tools -> Deploy Control SL, enter Communication parameters. Codesys says "Connected". Then tab "Deployment", there i select "CODESYS Control for Raspberri Pi SL" and "4.16.0.0 (all)". Click "Install" and the gui turns grey and unresponsive. The titlebar says "Untitled1.project - CODESYS (Not Responding)" as well. Restarting Codesys and checking shows no package was installed. How to deploy the runtime? Thank you in advance for your time. Edit: After some patience, an error showed up: "Error when sending ssh heartbeat: Session operation has timed out" "Error installing codesyscontrol" Any pointers to what remote command might have failed, or log of some sort, would be welcome. Software versions: Codesys version 3.5.21.10 Raspberry pi 5 (deployment machine): $ uname -a Linux raspberrypi 6.1.21-v8+ #1642 SMP PREEMPT Mon Apr 3 17:24:16 BST 2023 aarch64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 11 (bullseye) Release: 11 Codename: bullseye $ apt list --installed | grep openssh-server openssh-server/oldstable,now 1:8.4p1-5+deb11u3 arm64 Development machine: $ uname -a Linux 2B 6.1.0-35-amd64 #1 SMP PREEMPT_DYNAMIC Debian 6.1.137-1 (2025-05-07) x86_64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm VirtualBox Version 7.0.26 r168464 (Qt5.15.8) Virtual OS: Windows 10 Pro 64-bit (10.0, Build 19045) .NET version 4.0.30319.42000
Last updated: 2025-06-22

Post by bagusd on gateway problem CODESYS Forge talk (Post)
hello, I have a problem with the gateway not being able to connect to the plc, does anyone know why the gateway is difficult to connect to the plc? even though the lan cable has been connected to the plc and codesys gateway V3 has been restarted, thank you
Last updated: 2023-08-25

Post by gurke258 on Codesys Safety EtherCAT with Beckhoff CODESYS Forge talk (Post)
Okay, the solution was so simple... In my case, you first have to add the EL1918 and then the EL2904... then the connection is made automatically. I probably had something else before and then added the EL1918... then it doesn't catch the connection :/
Last updated: 2023-11-08

Post by timvh on FAILURE TO OPEN PROJECT ON ANOTHER COMPUTER CODESYS Forge talk (Post)
Is it really the same CODESYS version with the same add-ons? Maybe open the CODESYS installer on your home laptop, and export the configuration. On your work PC open the CODESYS installer and import the configuration.
Last updated: 2025-01-22

Post by eschwellinger on Licensing info not available. CODESYS Forge talk (Post)
the procedure is usually 1. install the Licenserver (on the host) with the deploy tool in CODESYS) 2. if you go to the CODESYS WBM you should see an empty Softcontainer 130-xxxxxx 3. activate the license with SoftContainer number and ticketnumber that was it!
Last updated: 2025-10-01

Post by yueqiqi on How to get the instance of a CANopen Master in the Device Tree? CODESYS Forge talk (Post)
I have been wondering of how to get the instance of a Canopen Master in the device tree, please see the picture in the attachment . Could anyone help me?
Last updated: 7 days ago

The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. CODESYS Forge talk (Thread)
The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
Last updated: 2026-01-27

Post by installwhat on IDialogOpenedListener CODESYS Forge talk (Post)
Why do you develop things like this? The workflow should be highly dependent on autocomplete, then if that's not super obvious browse to definition and everything is made clear possibly with the checking of a few types. The nature of how things are done makes me think these libraries aren't developed for general use and are actually internal or for partners. The example projects include objects that don't appear in autocomplete and then lead nowhere obvious when browsing. Do you consider developer workflow when creating these libraries? Are some libraries really for public use such as Visu Utils and others not? If so which? It's really hard to tell.
Last updated: 2024-08-06

Post by ph0010421 on How to create a stopwatch? CODESYS Forge talk (Post)
Do you need an 'hours-run' counter? And 1 second resolution is ok? I think you're over-thinking it. (The task time needs to be < 1second) Have a look at the LAD... Then, the time in seconds can be made into hh:mm:ss with this FUNction Declarations: FUNCTION funSecondsToStringTime: string VAR_INPUT InSeconds: UDINT; END_VAR VAR AsString: STRING; Minutes: UDINT; Hours: UDINT; Seconds: UDINT; MinutesAsString: STRING(2); HoursAsString: STRING(2); SecondsAsString: STRING(2); END_VAR and the code: Hours := InSeconds / 60 / 60; //Derive hours Minutes := (InSeconds - (Hours * 60 * 60)) / 60; //Derive minutes Seconds := InSeconds - ((Hours * 60 * 60) + (Minutes * 60));//Derive seconds HoursAsString := UDINT_TO_STRING(Hours); MinutesAsString := UDINT_TO_STRING(Minutes); SecondsAsString := UDINT_TO_STRING(Seconds); IF LEN(HoursAsString) = 1 THEN HoursAsString := CONCAT('0',HoursAsString); END_IF; IF LEN(MinutesAsString) = 1 THEN MinutesAsString := CONCAT('0',MinutesAsString); END_IF; IF LEN(SecondsAsString) = 1 THEN SecondsAsString := CONCAT('0',SecondsAsString); END_IF; AsString := CONCAT(HoursAsString, ':'); //assemble string AsString := CONCAT(AsString,MinutesAsString); AsString := CONCAT(AsString,':'); AsString := CONCAT(AsString, SecondsAsString); funSecondsToStringTime := AsString;
Last updated: 2023-12-08

Post by imdatatas on MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl [ERROR] CODESYS Forge talk (Post)
Dear @gseidel, Thank you for your reply. The exact version of Codesys and its compiler was 3.5.21.20. The compiler version was fixed and could not be changed in project settings. Since I couldn't continue due to this compilation error, I temporarily overcame this issue as follows. -- I completely uninstalled Codesys 3.5.21.20 and completely deleted the Codesys folder in the C:\ProgramData folder. -- I restarted my computer and installed Codesys 3.5.19.70. -- I updated the Codesys Installer and all its add-ons to the latest versions. -- The project that was giving me the compilation error I mentioned before is now open with Codesys 3.5.19.70, compiled it, and successfully downloaded it on the device. -- I haven't encountered the same problem anymore. I think this issue is related to SP21 and its compiler. Frankly, I'd expect a project created with an older version to compile without errors after opening it with the latest Codesys version and updating all libraries. Regards, imdatatas
Last updated: 2025-09-26

Post by trusty-squire on SysProcessCreate2 on Linux runtime CODESYS Forge talk (Post)
Hi, I'm trying to launch a continuously running python script from Codesys and monitor the script status inside the Codesys runtime (running on a Linux enviroment). For now I'm testing with the below to emulate a continuously running Python script: #test.py i = 0 while True: i += 1 I'm able to successfully run the script using SysProcessExecuteCommand2 (I can see the Python process running in the task manager). However, this "freezes" the Codesys execution of the task - it sits on that command and will not continue until the Python script ends. I've proven this works by using the task monitor to kill the process, then Codesys continues on happily through the task. What I want to do is use SysProcessCreate2 to set up the Python script as a background task and monitor the process using SysProcessGetState. This always results in the error "ERR_OPERATION_DENIED". I know that I'm able to execute commands (as above), so my config should be correct. Is SysProcessCreate2 functional on a Linux environment? Is there something in the config file I'm missing? Here's my "working" code that uses SysProcessExecuteCommand2: VAR bTest : BOOL; sCommand : STRING := '/usr/bin/python3 /var/opt/codesys/PlcLogic/Application/test.py'; refCommand : REFERENCE TO STRING REF= sCommand; sOutput : STRING; refOutput : REFERENCE TO STRING REF= sOutput; result : RTS_IEC_RESULT; END_VAR IF bTest THEN SysProcessExecuteCommand2( pszCommand:= refCommand, pszStdOut:= refOutput, udiStdOutLen:= SIZEOF(sOutput), pResult:= ADR(result) ); bTest:= FALSE; END_IF And here's the code that always results in the ERR_OPERATION_DENIED error: VAR bTest : BOOL; sApp : STRING := '/usr/bin/python3'; sCommand : STRING := '/var/opt/codesys/PlcLogic/Application/test.py'; refApp : REFERENCE TO STRING REF= sApp; refCommand : REFERENCE TO STRING REF= sCommand; hResult : SysProcess.RTS_IEC_RESULT; hHandle : SysProcess.RTS_IEC_HANDLE; END_VAR IF bTest THEN hHandle := SysProcessCreate2( pszApplication:= refApp, pszCommandLine:= refCommand, ulFlags:=SYSPROCESS_CREATEFLAG_HIDDEN, pResult:= ADR(hResult) ); bTest:= FALSE; END_IF Here's the relevant section from the config file at /etc/codesyscontrol/CODESYSControl.cfg: [SysProcess] Command=AllowAll Appreciate any support or ideas. Thanks!
Last updated: 2025-03-16

Post by mikek10 on Ethernet/IP 4.6.0 causing exceptions? CODESYS Forge talk (Post)
Hi, I have a project currently in development, it has a number of Ethernet/IP devices (18 adapter devices with Codesys as scanner, another scanner device with codesys as adapter). This has been stable whilst on factory floor for several months (though prior to that I did have some Ethernet/IP issues which were resolved by adjusting RPI rates). Today I tried updating to Ethernet /IP 4.6.0 from 4.5.1, subsequent to this I had 2 exceptions in a 2 hour period, I reverted to 4.5.1 and have had no further exceptions. Note I do have a device (Zebra printer) that frequently times out and reconnects, this does not seem to cause any issues in operation and does not cause any exceptions with 4.5.1. I believe the root cause of this is on the Zebra side, however there does not seem to be any adjustment I can make to prevent the time outs. Information from device log is in screenshot attached.
Last updated: 2024-06-27