Post by jroddball79 on PM556-TP-ETH — How to change IP address without overwriting the PLC program? CODESYS Forge talk (Post)
We have checked open ports. SSH (22) and HTTP (80) are not reachable. The only open ports are: 502 (Modbus TCP — used for lighting control) 1200 (CODESYS runtime) 1201 (CODESYS runtime) We can connect via Automation Builder using the current IP, but we don't have the original project source — only an empty project. This is why we are afraid of doing a full download, as it would overwrite the running application. Is there any way to change the IP through the CODESYS runtime protocol on ports 1200/1201 without affecting the running program?"
Last updated: 2026-05-20

Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring CODESYS Forge talk (Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26

Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring CODESYS Forge talk (Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26

Post by alex-n on Problem with keeping up the distance between two axes CODESYS Forge talk (Post)
Hello. I have a task to synchronize the movement of two axes and maintain the distance between them. First axe makes equal steps by trigger using MC_MoveRelative function. The second one is standstill and after another signal should catch up the first one from its position to a specified distance and keep it. I've tried to use MC_Phasing and mostly it works. Second axis catches up the first and starts make step with it. But in one moment this axis can crash into the first and there is no clear connection as to why this is happening. It can work correct for a day or for a week.
Last updated: 2026-06-04

Post by cd-tt on cannot connect ot linux runtime: device does not answer the scanrequest CODESYS Forge talk (Post)
I have the following setup: Proxmox PC with a debian 13 VM running CODESYS Control Linux SL and Edge Gateway. Installation method was through the Deploy Control SL and went rather smoothly. In my Device Tab I find the gateway and when scanning my network I also find my runtime. I want to connect and get promted that I should add a user. After setting up the user I get an error saying, that the device is not responding my scanrequest. Deploy Control SL Operation saying everythings up and running. I can confirm that from the terminal on the VM with "systemctl status codesyscontrol" and "systemctl status codesysgateway". I am running out of ideas how to fix that issue. Can anybody help? Screenshots attached.
Last updated: 2026-06-11

Post by steven-schalm on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
Yes, it's very tedious, especially since Codesys 4 is a custom web development... At Rex Automatisierungstechnik GmbH, we've invested a lot of time in the Python interface to enable something like CI/CD, but also to export the code and re-import it after making clean modifications. Also, the fact that a class/function block is just a single file containing all the methods, props, etc. Yes, and right now I’m building my own VS Code extension with a clean LSP (Language Server Protocol) for ST, as well as an st-validator, st-formatter, st-linter, codesysPackage.json, and codesys_modules folder... Best regards, Steven Schalm / Sharok6130
Last updated: 2026-06-11

Post by domebruce on TCP communication and TCP Streams CODESYS Forge talk (Post)
Hello, I'm doing some tests with TCP communication using Reader, Writer and TCP_Process components from NBS 4.0. I'm having a really hard time finding documentation and examples on these components. I found a very simple and incomplete example here: https://forge.codesys.com/prj/codesys-example/nbs/home/Home/. The documentation is also insufficient: it only provides the names of the FBs, Methods and their parameters, but no descriptions about how to use them. Do you have any suggestions on where to find more support? More generally, why is the free online CoDeSys documentation so poor? What do you think? Thanks Domenico Canavero
Last updated: 2026-06-16

Post by ophelia on Phantom Test Slot Preventing Suite Completion CODESYS Forge talk (Post)
Hi all, I'm working with a CODESYS 3.5 unit test framework on an embedded Linux PLC and running into an issue where a phantom test slot appears in the results that never completes, preventing the full test suite from ever finishing. The symptom: A blank-named test entry appears in the results table with an ever-increasing action count. It stays as "Testing" or "Failing" indefinitely. Because it never closes, bAllFinished never goes TRUE and the final report is never generated. Question: Has anyone seen this kind of phantom slot issue in a CODESYS unit testing setup? Thanks
Last updated: 2026-07-09

Post by timvh on HTML5 visualization controls disabled on CODESYS Control for Linux SL - overlay not supported? CODESYS Forge talk (Post)
I was able to reproduce this by doing something wrong. I guess what you did is first create an application for the Control Win, or some other device and then switched this to the Linux SL. But then the Visualization Manager still has the "TargetVisu" component, besides the WebVisu component. The Linux SL doesn't support this TargetVisu as part of the runtime. You should run a separate process for this. So remove the TargetVisu from the Visualization Manager and then you will be able to load the application.
Last updated: 2026-08-06

Post by tcarlbom on Read tag values using external program CODESYS Forge talk (Post)
This is my first time posting in this forum and I am new to codesys. I am a fullstack developer and I am trying to figure out how the following. What would be the best approach to create a own/custom tag browser? Either directly in codesys ide or using a separate custom program (perhaps a winforms application). 1.a. Shall I parse the .project xml file to get a list of all tags in the project? 1b. Shall I use python scripting in codesys ide to get a list of tags? Once one have selected some tags. These tags shall be exposed to a python program which will be acting as a edge computer. It’s fine to be able to import a file. 2a. I found a library called codesys plchandler which (as I understand) acts a rest api server. Is this correct? If so, can I query the api from a custom python script, ie can query what tags exist in project and or read tag values? My research so far. From earlier projects I know that using opc ua would be perfect for this but from my opinion it’s bloating the plc since it’s resource intensive. So opc ua is not an option. Codesys automation server is neat. But I don’t want to rely on some cloud services and subscription based pricing. There seem to be several interesting codesys libraries like mqtt, tcp server and NVL sender which would help me expose plc tags. But all have a common problem. One have to manually write what tags which will be used in these function blocks. I want a similar experience like “selecting” tags in the opc ua or the codesys tracing, ie a tag browser.
Last updated: 2024-06-28

Post by yannickasselin on MQTT QoS 1 & 2 CODESYS Forge talk (Post)
Hello, After some more tests, here is what I found out. It seems we have to increase the uiKeepAlive and tPingInterval parameters. If I increase the uiKeepAlive value to 60s and the tPingInterval to 30s, then if I disconnect the ethernet cable from Codesys and publish some messages to which Codesys subscribes to and then reconnect within 30s, I will get the messages. If I don't reconnect the cable within 30s (ping interval), the client goes in error with "ACKNOWLEDGE_TIMEOUT". When this happens, it will not automatically reconnect after reconnecting the cable. I have to disable and re-enable the client but I will not get the published messages. I need to do more tests because there are a lot of weird things happening when playing with the ping interval and the keep alive. It is not clear to me what does what. I even ended up not receiving messages anymore, even if I disabled and re-enabled the mqtt client. The client did not give any error. The only way I was able to get messages again was by modifying my client ID. After that, if I try to re-use one of the old client IDs, nothing works (publish, subscribe) and I get a TCP_INIT_ERROR and sometimes a TCP_READ_ERROR. I need more explanation/documentation about these weird behaviors. Maybe it is the way I use it, maybe it is related to the broker (I am using Mosquitto with default parameters). When using a Node-Red client, everything works perfectly. I am trying to achieve the same behavior with Codesys but it seems impossible so far.
Last updated: 2024-10-30

Post by jami on Reading multiple lines from csv file CODESYS Forge talk (Post)
Hello, i am trying to read multiple lines from csv file with caa file library and oscat. I have wrote 7 lines in the csv with separation '$R$L'. In my "extracting values" part I check line feeds and chars. After that I convert my buffer to string with oscat but I'm only able to read the first line from the csv. No matter if I even change start position where I start converting the buffer, I only get the first line. Here's my code for the reading and extracting value parts: 4: (*Reading the file*) fileread.hFile := filehandle; fileread.pBuffer := ADR(buffer); filesize1:=SIZEOF (buffer); fileread.szbuffer:=filesize1; fileread.udiTimeOut := 100000; fileread(xExecute := TRUE); IF fileRead.xDone THEN iFilesize:=TO_INT(fileread.szSize); writestate:=3; fileRead.xExecute := FALSE; END_IF 5: (*Extracting values*) //here i check the number of line feeds and chars. It works WHILE i < ifilesize DO c:=buffer[i]; IF c= 10 THEN IF lineindex<=99 THEN lineIndex := lineIndex + 1; END_IF ELSIF c <> 13 THEN IF charIndex <= 1000 THEN charIndex := charIndex + 1; END_IF END_IF i := i + 1; END_WHILE // Here i convert the buffer to string and transfer it to filelines:ARRAY[0..99] of string[254]. trig(CLK:=BUTTON); IF trig.Q THEN fileLines[i2]:=oscat_basic.BUFFER_TO_STRING(PT:=ADR(buffer), Size:=TO_UINT(fileread.szBuffer), start:=TO_UINT(bufferStart), stop:=TO_UINT(filesize1)); i2:=i2+1; bufferstart:=bufferstart+80; END_IF If anyone has idea how to read multiple lines, it would be nice. Even if you have example codes that work, that would help a lot.
Last updated: 2025-07-18

Post by serwis on Dynamic target position tracking CODESYS Forge talk (Post)
Hello, I am trying to control a servo drive and dynamically set its position. I control the drive via EtherCAT with a cycle time of 500us. I use the MC_MoveAbsolute block for this. The problem is that when using a PID controller, I generate the positions I want the drive to move to on an ongoing basis, and I would like the position to be set immediately. The MC_MoveAbsolute block must receive a rising edge to execute, and I would like the movement to be performed without waiting for this edge. I have created a function that generates a rising edge every 1 ms, but I am unable to change this time to 500 µs because the TON function does not support times shorter than 1 ms. Below is the code to call the rising edge: IF Exe = TRUE THEN delay1(IN:=TRUE, PT:=T#1MS); IF delay1.Q = TRUE THEN Exe := FALSE; delay1(IN:=FALSE); END_IF END_IF IF Exe = FALSE THEN delay(IN:=TRUE, PT:=T#1MS); IF delay.Q = TRUE THEN Exe := TRUE; delay(IN:=FALSE); END_IF END_IF END_IF Here is the code for calling the MC_MoveAbsolute function: MoveDegree( Axis:= Tilt, Execute:= Exe, Position:= position_target - (base_angle_real * feedforward_turn), Velocity:= vel, Acceleration:= acc, Deceleration:= dec, Jerk:= jerk, Direction:= MC_DIRECTION.shortest, BufferMode:= MC_BUFFER_MODE.Aborting, Done=> , Busy=> , Active=> , CommandAborted=> , Error=> , ErrorID=> ); I realize that there are probably better methods for performing this type of task. How can I implement motion with a dynamically changing setpoint? THANKS
Last updated: 2025-09-05

Post by matteodigani on Error using function block "Write alias address" CODESYS Forge talk (Post)
Hi, I've got a problem using the function block "Write alias address" (ETCStack library 4.9.0.0). this is the code: EtherCAT_1(); IF EtherCAT_1.ConfigRead AND enable THEN CASE seq OF 0: exec := FALSE; T.IN := TRUE; T.PT := T#10S; T(); IF T.Q THEN seq := 1; T.IN := FALSE; END_IF ; 1: T.IN := FALSE; T(); //THIS ONE WORK CORRECTLY! WrAliasAdd.xAbort := FALSE; WrAliasAdd.usiCom := DWORD_TO_USINT(EtherCAT_1.InstanceNumber); WrAliasAdd.wSlaveAddress := 1002; WrAliasAdd.xAutoIncAdr := FALSE; WrAliasAdd.uiAliasAddress := 19; WrAliasAdd.udiTimeOut := 3000; IF start THEN exec := TRUE; ELSE IF NOT error THEN start := TRUE; END_IF END_IF IF WrAliasAdd.xDone THEN start := FALSE; done := TRUE; error := FALSE; exec := FALSE; seq := 5; END_IF IF WrAliasAdd.xError THEN start := FALSE; done := FALSE; error := TRUE; exec := FALSE; END_IF ; 5: exec := FALSE; T.IN := TRUE; T.PT := T#1S; T(); IF T.Q THEN seq := 10; END_IF ; 10: T.IN := FALSE; T(); //THIS ONE GIVES ME AN ERROR! WrAliasAdd.xAbort := FALSE; WrAliasAdd.usiCom := DWORD_TO_USINT(EtherCAT_1.InstanceNumber); WrAliasAdd.wSlaveAddress := 1006; WrAliasAdd.xAutoIncAdr := FALSE; WrAliasAdd.uiAliasAddress := 25; WrAliasAdd.udiTimeOut := 1000; IF start THEN exec := TRUE; ELSE IF NOT error THEN start := TRUE; END_IF END_IF IF WrAliasAdd.xDone THEN start := FALSE; done := TRUE; error := FALSE; exec := FALSE; seq := 99; END_IF IF WrAliasAdd.xError THEN start := FALSE; done := FALSE; error := TRUE; exec := FALSE; END_IF ; ELSE ; END_CASE WrAliasAdd(xExecute := exec); END_IF The first one slave ethercat works correctly, but the other one gives me an error. Attached the ethercat configuration of the devices. All the devices are set "Optional". So my idea is to enable only the first one (1002) and the fifth one (1006).
Last updated: 2025-10-01

Post by e13740e on Сalling the context menu from the keyboard CODESYS Forge talk (Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05

Post by e13740e on Сalling the context menu from the keyboard CODESYS Forge talk (Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05

Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys CODESYS Forge talk (Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I updated the docker container runtime to version 4.11.0.0. and build the container with this "Dockerfile" FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.11.0.0" ENV EDGE_VERSION "4.11.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package '*codemeter*.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package '*codesyscontrol*.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codemeter start && /etc/init.d/codemeter-webadmin start && /etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"] Now cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 8.00 of 2023-Nov-28 (Build 5967) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. But still CODESYS development system reports that it needs a dongle and when I click install that "value cannot be null. Parameter name: containerToLicenses" It seems that Codemeter is forced to look for a dongle instead of a CMsoftcontainer. Can you confirm that CODESYS licensing works also when CODESYS is installed in a Docker container?
Last updated: 2024-03-21

Post by duvanmoreno24 on Modbus writing on value change CODESYS Forge talk (Post)
Hi all, I want to know if someone has an idea of how I can write on value change in Modbus Codesys. I have a Wago PLC and I was used to work with E-cockpit which it was quite easy to do that without the necessity to trigger any value when there was a change in the variable ( I will put how easy is ). how you can see just changing the trigger in "On value Change" will do that channel writing automatically when It detects a change in those arrays. On the other hand, in Codesys if I enable the rising edge in Codesys It ask me to put a bool variable and if triggers is going to write that value. That is making me that I have to create a function or a logic to detect the change, the problem I have is that doing that is very tedious. I first approach I got it was to create a Function who returns a bool when the value change, but I tried to keep the old value but what is happening is that in Functions all the data is erased every cycle so I can not keep any Old value. so in the Main program the trigger is going to be TRUE all the time due, the old value is cero every cycle. The second approach I got it was using a function Block (POU_1) and it works but I dont want to instance that function for every Channel or value that I want to check if the value change, Basically if I have 200 values to write trhough modbus I have to create 200 instances of that function which I think it is not practicall at all. It should be a better way to implement this as e-Cockpit from Wago Does. However, I haven't been able to know how.
Last updated: 2024-03-26

Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins CODESYS Forge talk (Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15

Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins CODESYS Forge talk (Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15

Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins CODESYS Forge talk (Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15

Post by leandroct on Error reading files after runtime update from 4.0.0.0 to 4.8.0.0 CODESYS Forge talk (Post)
Since version 19 they changed how file access is handle. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 The CodesysControl.cfg is at C:\ProgramData\CODESYS\CODESYSControlWinV3x64\xxPROJECT_NUMBERxx\ Here the email they sent me: "with the 3.5.19 Version we changed how files are handled. See following issue: CDS-81506 - CODESYS Control SysFile system file access vulnerability. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 Here is the official release-note: [[COMPATIBILITY_INFORMATION]] With the activation of ForceIecFilePath the file access from IEC is now restricted to the configured paths only (file sandbox)! [SysFile] ForceIecFilePath=1 (new default) The standard path is the current directory, the PlcLogic subfolder or a configured path. Every file access outside of this path is configured via PlaceholderFilePath, for example access to temporary files or removable media: [SysFile] PlaceholderFilePath.1=/tmp, $TMP$ PlaceholderFilePath.2=/media/usb, $USB$ PlaceholderFilePath.2.Volatile=1 For more information see our tutorial FilePath & Placeholders. To restore the old behavior ForceIecFilePath may be configured as follows: [SysFile] ForceIecFilePath=0 BUT WE HIGHLY RECOMMEND TO LEAVE THIS SETTING AT ITS NEW DEFAULT VALUE! "
Last updated: 2024-05-07