Array of Bits
CODESYS Forge
talk
(Thread)
Array of Bits
Last updated: 2023-07-11
Out of persistent memory
CODESYS Forge
talk
(Thread)
Out of persistent memory
Last updated: 2021-03-22
Change Velcoity of MC_MoveAbsolute
CODESYS Forge
talk
(Thread)
Change Velcoity of MC_MoveAbsolute
Last updated: 2018-06-28
Array of FB initialization
CODESYS Forge
talk
(Thread)
Array of FB initialization
Last updated: 2018-02-15
Two version of codesys
CODESYS Forge
talk
(Thread)
Two version of codesys
Last updated: 2019-11-13
Testing of Codesys program
CODESYS Forge
talk
(Thread)
Testing of Codesys program
Last updated: 2023-12-08
Inheritance of axis
CODESYS Forge
talk
(Thread)
Inheritance of axis
Last updated: 2024-01-12
Losing focus of variable
CODESYS Forge
talk
(Thread)
Losing focus of variable
Last updated: 2024-03-26
History of Alarms
CODESYS Forge
talk
(Thread)
History of Alarms
Last updated: 2026-01-07
History of Alarms
CODESYS Forge
talk
(Thread)
History of Alarms
Last updated: 2026-01-05
Post by askjong on Update variables when OPC UA Client updates. Error ID: 268468277 BadAttributeIdInvalid
CODESYS Forge
talk
(Post)
Hi, I'm connecting to a OPC UA Server using the Data Soruce Manager OPC UA Client. This works well until the OPC UA Server updates and the OPC UA list doesn't match up when i did last clicked the "Update variables" to add variables. All the variables are still the exists and none are removed from the server, but more are added during the engineering process. The error message i get in CODESYS is "Error in OPC UA call BadAttributeIdInvalid, Error ID: 268468277". The issues is fixed when i press the "Update variables" button and just press ok without adding or removing any variables in the list. Is there a way to either automatically update the browsepath if it fails or on startup, or to trigger it by code?
Last updated: 2024-01-08
Post by eaglealex on Length of string and Array of bytes
CODESYS Forge
talk
(Post)
Hello! I have tried read a file to the string variable. But I faced a problem - there is about 2800 bytes of information in file, but string have a limit 2393 bytes. I made two variables with same address (for automatic convertion) - string[3000] and array of bytes[1..3000]. And I noticed that array of bytes contains all information from file, but string shows only first 2393 bytes. So I have lost information. Is there really such a limitation? Or I have an error in my program and Codesys 2.3 have no limit for such kind of conversation between string and array of bytes? Thank you very much!
Last updated: 2025-04-01
Post by talhaali on Persistent variables not working for Control Win
CODESYS Forge
talk
(Post)
Hi everyone, I am facing issues with persistent retain variables. It was working fine. I added a few new Persistent variables and it stopped working. If I do cold reset it holds persistent variable values. But when I close control win gracefully, and opens it again then it does not. Even, it is not saving ret file in application.
Last updated: 2024-09-10
Post by pietrobalint on Persistent variables are not read after initialization
CODESYS Forge
talk
(Post)
Hi, I realized that if I replug the power supply the persistent variables lost their value with the new software too. Cold reset do not affect the variables value but hardware reboot still reset the values. Application Composer can't be activated. What is the solution?
Last updated: 2024-10-11
Post by timvh on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS)
CODESYS Forge
talk
(Post)
It is a known issue. It only happens with CODESYS and Wago controllers and the Persistent Variables. It seems related to using 64 bit variables in the PV list (e.g. LREAL). Internally in the PLC everything works okay. It is just a monitoring issue.
Last updated: 2025-10-26
Post by osande on Trend/trace data
CODESYS Forge
talk
(Post)
Ok, the problem is that the trend/trace system can't read function block instance data. The variables has to be stored directly under the program calling the FBs. Thus, FB variables to be trended/traced must be connected to variables declared in the program. Seems like a bug to me!
Last updated: 2026-03-13
Post by r-niedermayer on C0564 Warning Message
CODESYS Forge
talk
(Post)
Please see or Online Help on how to initialize variable before using them: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_global_init_slot.html Regarding the Attribute global_init_slot: You can use this pragma to influence the order in which signatures are processed during global initialization. It can only be applied to signatures. By default, the initialization sequence for variables from global variable lists is undefined! However, if, for example, variables from one list depend on variables from another list, it is necessary to initialize one before the other. (Aee OLH and Syntax) The placeholder <slot> must be replaced by an integer value that defines the position in the initialization sequence.</slot> The default value is 50000. A lower value causes an earlier initialization! If several signatures have the same value for the 'global_init_slot' attribute, the order of their initialization remains undefined! Cautious application should therefore be considered! Example: The project contains f.e. two global variable lists GVL_1 and GVL_2. The global variable "A" is part of the global variable list GVL_1: {attribute 'global_init_slot' := '300'} VAR_GLOBAL A : INT:=1000; END_VAR The initialization values of the variables "B" and "C" of GVL_2 are dependent on the variable "A". {attribute 'global_init_slot' := '350'} VAR_GLOBAL B : INT:=A+1; C : INT:=A-1; END_VAR So if you set the 'global_init_slot' attribute of the global variable list GVL_1 to 300, i.e. to the lowest initialization value in the example, then it is ensured that the expression "A+1" is well-defined at the time of initialization of "B".
Last updated: 2024-01-30
Post by hambergg on Retain Variables on fRAM
CODESYS Forge
talk
(Post)
Hi regarding NVRAM with SPI or I2C I expected reference too!
Last updated: 2024-09-03
Post by danieldiaz on Problem with FB execution
CODESYS Forge
talk
(Post)
Problem Solved, I was overwriting the variables somewhere else
Last updated: 2024-04-05
Post by dominggus on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
I still have the same problem even when updating to CODESYS Recipes 4.3.0.0. My scenario: I'm trying to save/load an array of structs using the Visu: - Execute Command > "SaveRecipeAs" works properly - Execute Command > "LoadWriteRecipe" works not entirely: the structs of array[6] and array[7] should have been empty but were duplicates of array[4] and array[5]... the struct contains 26 variables and the array's length is 30.. Maybe there is a upper limit on recipe variable count?
Last updated: 2024-03-02
Post by nathant on Saving variable values on power cycle (RevPi Connect)
CODESYS Forge
talk
(Post)
Hello, this seems to be a known issue, but persistent/retain variables don't seem to work properly on RevPi devices. Is there a workaround to this? All I need is for a few configuration variables to be remembered through power cycle.
Last updated: 2023-12-03
Post by fless on Help with __SYSTEM.VAR_INFO
CODESYS Forge
talk
(Post)
to get the address just use ADR( ) variables defined in a VAR_IN_OUT block are references pointing to the passed variables. VAR_IN_OUT MyVar: bool; END_VAR VAR adrMyVar: __XWORD; END_VAR adrMyVar := ADR(MyVar);
Last updated: 2025-01-26
[Bug report] Issue with Importing XML Files Containing "POINTER TO" Variables in Codesys Platform Plugins Versions 2.7 and 2.8
CODESYS Forge
talk
(Thread)
[Bug report] Issue with Importing XML Files Containing "POINTER TO" Variables in Codesys Platform Plugins Versions 2.7 and 2.8
Last updated: 2025-03-26
Can a table be used as an input to date and time variables on a function block diagram?
CODESYS Forge
talk
(Thread)
Can a table be used as an input to date and time variables on a function block diagram?
Last updated: 2022-09-15
Can a table be used as an input to date and time variables on a function block diagram?
CODESYS Forge
talk
(Thread)
Can a table be used as an input to date and time variables on a function block diagram?
Last updated: 2022-09-15
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.