Post by simotion on Inheritance of axis
CODESYS Forge
talk
(Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07
Post by apurv on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
I found a way to do it: You can use, for example, the text variable property of any visualization element and call a function in it. Example: Write a test POU as a function (FUN), like MyTestFun which need a boolean Variable as an input value. Now write into the text variable property: MyTestFun(bBooleanValue) Thats it. The function is called at each visu_task cycle.
Last updated: 2024-01-22
Post by micik on CAA File, how to check whether file exists or not
CODESYS Forge
talk
(Post)
Hello, what would be the most efficient way to check whether the file exists or not. I don't want to use file.Open function, it seems like rather inefficiet operaton. I considered GetAttribute function, but this function doesn't accept filename (with path) as an input. Basically I need to check first time when program is loaded to the runtime i.e. when application is started for the first time, whether a file exists on the specific location or not.
Last updated: 2024-05-16
Post by namwind on Wago 8210
CODESYS Forge
talk
(Post)
Hi guys, I ran into problem with the controller is not saving the project into the internal memory. I was able to download the project to the controller, but as soon as I try to recycle the power it power back up with no project. I have not ran into this problem before. Please help me out thank you.
Last updated: 2024-03-02
Post by i-campbell on Ping By Name
CODESYS Forge
talk
(Post)
https://content.helpme-codesys.com/en/libs/Net%20Base%20Services/3.5.19.20/NetBaseServices/Function-Blocks/IP/fld-IP.html resolve hostname and ping?
Last updated: 2023-08-24
Post by matthew on New Ladder Editor Issues
CODESYS Forge
talk
(Post)
Hi There, When using the new ladder editor there is no option for function blocks to Remove uncalled FB call parameters. I also see no update function block. When you double click the function block it no longer opens the function block. I also now get warnings if I insert FB call without a contact in front. Warning is: (Impl)): C0373: Expression or part of it has no effect I take it the new editor must work differently? The only reason for using new ladder editor is the ST execute/block editing is far better, If you have alot of text in the old ST execute the editor window is very small and when online it's even worse. The new ST block seems a lot better Thanks!
Last updated: 2023-10-10
Post by smartcoco on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
I think what you want is a declaration period function for the page, but unfortunately CODESYS does not have it.
Last updated: 2023-10-17
Post by jerry-sorrells on Find Function: Object reference not set to an instance of an object.
CODESYS Forge
talk
(Post)
Build: CODESYS 3.5 SP19 Patch 1 (64-bit) Host OS: Windows 10 Target: Linux SL I have a project with programs in Structured Text and Ladder Diagram. When I try to use the Find function, it works for the Active Editor; however, when I try to use Find for the Entire Project, I get the error "Object reference not set to the instance of an object." I know what this error means in the context of the program, but I have no idea why the find function is returning this error. The variable I am searching does not matter: it happens with all variables. Any help with this will be greatly appreciated. I generally use the Find function quite often as I am developing and not having it is really slowing me down.
Last updated: 2023-10-23
Post by pascaljt on Function block for Ethernet/IP
CODESYS Forge
talk
(Post)
Hello, I program a function for an Ethernet/IP controller. I made a structure with input and output corresponding with the map of my controller for the function block. My problem is that I don't know how to do the link between the controller and my PLC (CC 100 from Wago). The addresses declare in Codesys are illogic, The first addresses are 12 and 13 then 7 then 4. How to do corresponding the addresses of the controller and the input / output structure ? IP adress ? Does I must create the all variables of controller with the controller adresses to use with the function block ? Thanks for your help. (I hope I'm clear, I'm not english)
Last updated: 2023-10-26
Post by user3000 on Can't find an Extended Pulse Timer (TP and LTP)
CODESYS Forge
talk
(Post)
I came up with an FBD that seems to be working, although it may not be a true Retriggerable Pulse timer. There may be some delay associated with the two MOVE functions and ADD function I incorporated. I'd be interested if anyone is able to come up with something cleaner. I am surprised that this is not a built-in function block of the CodeSYS library. This is a common feature of multi-function timer relays. I also attached a page from the cut sheet of a Schneider relay that shows 10 timing functions. Looks like the CodeSYS library has built-in function blocks for only 3 of the 10.
Last updated: 2023-12-21
Post by totorovic on How to display the application name on a visualization (V3.5.16)
CODESYS Forge
talk
(Post)
You could use the function AppGetApplicationInfo from CmpApp library. https://content.helpme-codesys.com/en/libs/CmpApp/Current/AppGetApplicationInfo.html
Last updated: 2024-05-14
Post by timvh on Display minutes as hours & minutes
CODESYS Forge
talk
(Post)
You could use the Modulo function to get the minute part from the total minutes: Minutes := TotalMinutes MOD 60;
Last updated: 2024-05-27
Post by timvh on Sensor not set
CODESYS Forge
talk
(Post)
Your function block instance is not called, so the code is not executed to set the light on when the button is pressed.
Last updated: 2024-05-27
Post by eguerra on Error in ScriptingEngine Docs - create_pou()
CODESYS Forge
talk
(Post)
In the ScriptingEngine documentation there seems to be an error (or missing information) in the ScriptIecLanguageObjectContainer part ( https://content.helpme-codesys.com/en/ScriptingEngine/ScriptIecLanguageObjectContainer.html#ScriptIecLanguageObjectContainer.ScriptIecLanguageObjectContainer ). The description of the function create_pou() doesn't specify the correct arguments requested, it only says create_pou(type: SpecialPouType) and a script using the documentation definition of the function will raise an error. I tried passing the function arguments similar to the ones specified for the create_dut() function and it seems to work fine: create_pou(name, PouType) , name : str UPDATE: The offline help has the correct definition IExtendedObject<IScriptObject> create_pou( string name, PouType type = PouType.FunctionBlock, Nullable<Guid> language = null, string return_type = null, string base_type = null, string interfaces = null )
Last updated: 2024-08-05
Post by tk096 on SMC_NCDecoder very slow to decode lines
CODESYS Forge
talk
(Post)
Hi, you can call the decoder function block in a loop and/or decrease the task cycle interval of Task_PATH.
Last updated: 2024-08-23
Post by opineiro on Stack overflow with really simple function
CODESYS Forge
talk
(Post)
Thanks, I'm going to rework everything with this in mind.
Last updated: 2024-09-23
Post by gatto on library ModbusTCP Slave 4.1.0.0 - function block ModbusServer
CODESYS Forge
talk
(Post)
I've always liked codesys, but sometimes it drives me crazy
Last updated: 2024-11-28
Post by struccc on library ModbusTCP Slave 4.1.0.0 - function block ModbusServer
CODESYS Forge
talk
(Post)
:) Yeah... Definitely not a "boring" platform, they are nice to give us work for the upcoming years... :)
Last updated: 2024-12-02
Post by tvm on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
maybe this would be a better approach, then you don't have to pass the constant at all. FUNCTION fun : INT VAR_IN_OUT arr: ARRAY[*] OF INT; END_VAR VAR lower: DINT; upper: DINT; END_VAR lower:= LOWER_BOUND(arr, 1); upper:= UPPER_BOUND(arr, 1); see here as well https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_datatype_array/
Last updated: 2024-01-08
Post by tvm on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
It will be a reference, because it's a VAR_IN_OUT. it's a little weird debugging the array online. It just shows as a POINTER TO INT, and you can't actually see the array from the function side. But you can still work with it as a normal array, not a pointer.
Last updated: 2024-01-09
Post by scarter on Bit / Bool data types in function parameters
CODESYS Forge
talk
(Post)
Any reason BIT and BOOL data types are not interchangeable? Trying to make a function which takes a BOOL IN/OUT parameter (Not allowed to use BIT) In the main logic if I make a DINT variable, and want to use each bit on different functions CODESYS will not allow it.
Last updated: 2024-01-17
Post by timvh on Limiting Memory Access of an Array to Within its Bounds
CODESYS Forge
talk
(Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06
Post by siscu on Raspberry Pi: List of available example applications
CODESYS Forge
talk
(Post)
Could this be turned into a library? I'd love for a way to have the main program call a function block method using the program's I2C_master device. I assume I should be passing the master as a variable for the function block, but I don't see how that could be achieved
Last updated: 2024-05-15
Post by kumareasu on Persistent variable storage
CODESYS Forge
talk
(Post)
Is there any function function block which can store the persistent variable in HDD/SSD immediatley. My observation is that the persistent variable is getting stored when we shut down or restart the system (Windows+ CoDeSys RTE SL ). the persistent variables are not stored in HDD/SSD, if I power off the system without proper shutdown. Seeking your feedback.
Last updated: 2024-06-12
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.