Search talk: WHERE TO FIND SHR BLOCK

 
<< < 1 .. 132 133 134 135 136 .. 236 > >> (Page 134 of 236)

Post by vsgn on Passing properties as VAR_IN_OUT variables. CODESYS Forge talk (Post)
Hi, in my experience, the best options for such a case could be: 1. Pass a FunctionBlock via VAR_IN_OUT, containing all variables, mehods and properties needed for the logic of this graphic element (be aware of implementing correcly both get and set accessor for properties) 2. Pass an Interface via VAR_INPUT, of which you can use obviously only Properties and Methods. This is much more elegant for me. Here, you can just pass directly the instance of a FunctionBlock implementing such Interface as input. Hope you'll find this suggestions useful.
Last updated: 2025-05-13

Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200 CODESYS Forge talk (Post)
Turns out I managed to get a connection to my PLC. It seems that a few weeks ago Wago released something with version 4.3.3(25). So I reset my PLC to Factory-Reset, set it to the 192.168.1.17 IP and changed the IP to the one I wanted with the Wago EthernetSettings tool. Then updated the latest firmware using the WAGOupload tool. Now the PLC came back up without a PLC runtime running, so in the Web-tool I wen't to the "Configuration"/"PLC Runtime" and selected the runtime version "CODESYS V3". I uninstalled all Codesys versions and installed the version from the download package of Wago together with all the packages the bundle provided. After creating a new project I didn't select the old PFC200 runtime, but one of the dozens of new device profiles, that it now listed. With these settings I was then able to connect to my PLC. Now I hope I'll get the existing project that I had ported to this new structure. Sorry for the noise. Chris
Last updated: 2023-08-26

Post by ofey on Codesys Soft PLC OPC UA server CODESYS Forge talk (Post)
Hi! I'm sorry if this has been asked before. I have tried looking up previous topics regaring this, but even though I'm following tutorials and other posts I cant seem to get this to work consistently. I actually got the connection established on a test project after some trial and error. I only got it to work with the "Anonymous login". But after i deleted the test project and tried to get the same thing to work on another project I cant get it to work anymore. What I'm trying to do: Set up and OPC UA Server using CODESYS with the free soft PLC. I then try to connect to the OPC UA Server with the program "UaExpert". What happens: I get the error Error "'BadUserAccessDenied' was returned during ActivateSession". What I have done in CODESYS: - Added the object "Symbol configuration" and checked some test variables - Checked "Support OPC UA features - In "Communication settings -> device -> Change runtime security policy" I have checked "Allow anonymous login" What I have done in UAExpert: - Found the OPC UA server under "local". (It is showing two servers though, I do not know why. It showed the same when it worked yesterday). Se attachment - Checked "Anonymous" under "Authentication settings in the OPC UA server. I'm new to CODESYS, so it could be something elementary wrong in my settings. Maybe something in the user settings in CODESYS regarding user rights or something?
Last updated: 2023-09-14

Post by karel-bas on Loosing connection to emulation running on Linux CODESYS Forge talk (Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19

Post by struccc on The future and proper use of CAA.BOLT, CAA.SEMA,.. CODESYS Forge talk (Post)
Dear All, Dear CODESYS, I'm curiously following CODESYS transitioning away from the CAA libraries, and I'm mostly in favor of these major changes. Naturally, I'd like to align my current (not end-user) developments accordingly. I'm tracking , reading release notes, ... And want to figure out the future :) Is it possible to hear / read more about the reasons, objectives and scope of these changes? One important element is CAA Types - CAA Types Extern. What is the plan with that? What's the future of CAA.SEMA, CAA.BOLT ? I have never used them (always relied on SysLib*), but they are tempting... Would be useful to have a platform independent "Macro" for this functionality... Is there something in existing or planned ? Are they suitable to be used in low level libraries... For Example IO-Drivers, Components, "to-become system libraries"? CAA.TaskLock, CAA.TaskUnlock ? Well, they don't claim platform independency, so I can't rely on those.... Any up-to-date advise, standard, pattern to follow in new libraries for task and resource locking? Practical set of conditional defines to be used? If this information is not publicly available, can you please send a private message about the proper way to achieve this? I have support agreement, just couldn't get trough with these questions... P.
Last updated: 2025-03-14

Post by latassan on RaspberryPi 5 gateway problem CODESYS Forge talk (Post)
Hello, I'm trying to use a raspberryPi 5 as a PLC. I fixed its IP address, I can ping it. I've also installed the CODESYS Control for Raspberry Pi 64 SL runtime on it. So I've created a gateway (IP address of the Raspberry, TCP port 1217). I see the green dot next to this gateway. When I do a network scan, I can see my raspberry (see photo). When I try to connect to it, I have to define an administrator profile, which I do. On validation, I see a message: No device is responding to the scan request. I've checked that port 1217 is listening on the raspberry, I've uninstalled the runtime then installed it again, but I can't connect. Also, when I try to configure the user groups before connecting, I see that Offline mode is not supported by the device, even though I'm connected to it in the Deploy Control SL tab. When I try to refresh, I see: Gateway not configured properly. How can I connect to my Raspberry? Have I defined my gateway incorrectly?
Last updated: 2025-06-12

Post by duvanmoreno24 on Modbus writing on value change CODESYS Forge talk (Post)
Yes, I tried to do what you put in the first code. However, I have a problem with that and that is that the inputs must be declared with the type. I have many data types running in my code (real, int, uint, bool) and I can't put them in the same function, another thing is that I need to instantiate that function for everything I want to write to the slave. You put a for to 200 but it means that it has to be the same data type and inside the array, but I want to get them individually. I'm struggling to do it in a good and efficient way like wago's E-cockpit does. in the first screenshot you can see, you simply type in value, change the package of things you want to write in value change and it does everything by itself automatically, without comparing any old and new values and even less having the need to activate a bool. , it is perfect.
Last updated: 2024-04-03

Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27

Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27

Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27

Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27

Post by honorzen543 on Temu Coupon Code 30% Off [acu729640] For Existing Customers CODESYS Forge talk (Post)
We’re thrilled to introduce the Temu coupon code 30% off, a deal that’s bound to excite all online shoppers! With this amazing offer, you'll save significantly while still enjoying a wide range of products on the Temu platform. Our exclusive coupon code, [acu729640], brings maximum benefits to individuals residing in regions such as the USA, Canada, the Middle East, and several European nations. This code is specially designed to provide international users with unmatched savings and a seamless shopping experience. For those eagerly awaiting 2024, the Temu coupon code 2024 for existing customers is here, accompanied by the fantastic Temu 30% discount coupon. This promotion ensures that both new and existing users get the most out of their shopping journey on Temu. What Is The Temu Coupon Code 30% Off? The Temu coupon 30% off is your gateway to incredible savings on Temu’s app and website. Whether you're a new user or an existing customer, using our 30% off Temu coupon code gives you access to great deals and discounts. [acu729640]: This code grants new users a flat 30% off on their first purchase. [acu729640]: Existing users can enjoy a 30% extra discount when using this code. [acu729640]: New Temu customers can benefit from a flat $100 off. [acu729640]: Unlock a $100 coupon pack usable on multiple purchases. [acu729640]: Exclusive $100 flat discount specifically for new Temu users in the USA, Canada, and Europe. [acu729640]: Existing customers can receive an additional $100 off with a promo code. [acu729640]: Special $100 coupon available for users in the USA, Canada, and Europe. Temu Coupon Code 30% Off For New Users For those new to the Temu platform, the Temu coupon 30% off offers the highest savings potential. Experience a world of rewards and benefits with the Temu coupon code 30 off for existing users, now accessible to all first-time shoppers. [acu729640]: Secure a flat 30% discount as a new user. [acu729640]: Old users receive an additional 30% discount benefit. [acu729640]: Access a $100 coupon bundle for new customers. [acu729640]: Benefit from up to $100 in a coupon bundle for multiple uses. [acu729640]: Free shipping to an impressive list of 68 countries. [acu729640]: First-time users get an extra 50% off on any purchase. How To Redeem The Temu 30% Off Coupon Code For New Customers? Unlocking the Temu 30% off deal is a breeze with our Temu 30 off coupon code. Follow these simple steps for redemption: Visit the Temu app or website and create an account as a new user. Browse through the extensive catalog and add your desired items to the cart. At checkout, enter the coupon code [acu729640] in the designated field. Verify that the 30% discount has been applied to your total. Complete the purchase with your preferred payment method. Temu Coupon Code 30% Off For Existing Users Existing Temu users can continue to enjoy savings with the Temu 30 off coupon code. Our Temu coupon code for existing customers ensures you don’t miss out on top deals. [acu729640]: Existing Temu users receive an extra 30% discount. [acu729640]: Secure a $100 coupon bundle applicable for multiple purchases. [acu729640]: Enjoy a free gift with express shipping across the USA and Canada. [acu729640]: An extra 50% off layered onto existing discounts. [acu729640]: Free shipping across 68 countries globally. How To Use The Temu Coupon Code 30% Off For Existing Customers? To leverage the Temu coupon code 30 off as an existing customer, follow these easy steps with the Temu discount code for existing users: Log in to your Temu account on the app or website. Choose items from a diverse selection and add them to your cart. At checkout, input the code [acu729640] in the coupon code box. Confirm the additional 30% discount on your order. Proceed to pay and complete your purchase. How To Find The Temu Coupon Code 30% Off? Finding the best Temu coupon code 30% off first order and the latest Temu coupons 30% off is a straightforward process. We recommend signing up for the Temu newsletter to receive verified and tested coupon codes directly in your inbox. Additionally, visiting Temu’s social media pages will keep you updated on the latest promos and offers. Trustworthy coupon sites are also a reliable source for discovering the most current and valid Temu coupon codes. How Does Temu 30% Off Coupons Work? The Temu coupon code 30% off first-time user offers a substantial discount on your first purchase, making it an irresistible deal for new Temu shoppers. Simply apply the Temu coupon code 30 percent off at checkout, and watch the savings roll in. This initiative not only facilitates budget-friendly shopping but also introduces new users to the exceptional range of products available on Temu. The coupons work seamlessly, offering significant savings across a vast selection without any hidden conditions. How To Earn 30% Off Coupons In Temu As A New Customer? To earn the Temu coupon code 30% off, new customers need to sign up on the Temu platform and explore the introductory offers. Our Temu 30 off coupon code first order is designed to reward first-time users with an enviable discount. Besides the initial welcome deals, new customers can participate in Temu’s promotional events, referral programs, and social media campaigns to earn additional savings. These efforts ensure customers can consistently enjoy discounts on every purchase. What Are The Advantages Of Using Temu 30% Off Coupons? Temu 30% off coupon code legit: Verified discounts ensuring legitimate savings. Coupon code for Temu 30 off: 30% reduction on your first order. $100 coupon bundle applicable for multiple transactions. Up to 70% discount on popular items sitewide. Extra 30% off for returning Temu customers. Discounts of up to 90% on selected items. Free gift provided for new users. Free delivery to 68 countries worldwide. Temu Free Gift And Special Discount For New And Existing Users With the Temu 30% off coupon code, everyone can take advantage of multiple benefits. The 30% off Temu coupon code brings you closer to special offers and exclusive gifts. [acu729640]: Enjoy a 30% extra discount on your first order. [acu729640]: An additional 30% off any item in your cart. [acu729640]: Free gifts available for new Temu users. [acu729640]: Receive up to 70% off any item on the Temu app. [acu729640]: Free gift with complimentary shipping to 68 countries, including the USA and UK. Pros And Cons Of Using Temu Coupon Code 30% Off Pros: Temu coupon 30% off code: Provides significant savings across the platform. Wide range of applicable products. Available for use in multiple countries. Free shipping benefits enhance value. No expiration date adds flexibility. Cons: Temu free coupon code 30 off might not be combinable with other deals. Limited to certain product categories. Seasonal availability can vary. Terms And Conditions Of The Temu 30% Off Coupon Code In 2024 Temu coupon code 30% off free shipping: Available for all orders with no minimum purchase required. Temu coupon code 30% off reddit: Community-tested and endorsed. No expiration date; use whenever convenient. Valid for both new and existing users in 68 countries. All purchases qualify with no minimum spend required. Final Note With the Temu coupon code 30% off, your shopping experience is about to reach new heights. Whether you're a new or existing customer, the Temu 30% off coupon promises unbeatable value and convenience. FAQs Of Temu 30% Off Coupon How can I use the Temu 30% off coupon code? Visit the Temu website or app, add items to your cart, and enter the coupon code [acu729640] at checkout to enjoy your discount. Can existing customers get a discount with this coupon code? Yes, the coupon provides existing customers with an additional 30% off on their purchases. Is the Temu coupon code valid for international users? Absolutely! The coupon code is available to users in 68 countries, including the USA, Canada, and several European nations. Are there any restrictions on the Temu 30% off coupon code? No, there are no minimum purchase requirements, and the code can be used at any time. How often can I use the Temu coupon code? The Temu coupon code can be used multiple times, especially if you’re a new user benefiting from the first purchase offer.
Last updated: 2024-10-26

Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port CODESYS Forge talk (Post)
I have an IPC with 2 ethernet ports and 1 Wi-Fi. I'm using ModbusTCP with the ethernet port named "enp2s0" connected to my remote I/O. This works fine when testing with Python and also works with CODESYS, but CODESYS is only able to scan for the Linux SoftPLC when I turn off the "enp2s0" interface. In other words, I can't get online with the IDE if I want my ModbusTCP comms to run with CODESYS. I'm using a Linux SoftPLC that has the following entry in CODESYSControl.cfg, hoping that this will allow me to connect with "enp1s0" or "wlp3s0", and leave "enp2s0" for field comms, but this seems to only make the source IP of the ModbusTCP comms to be bound to "enp2s0". That last point is the case only if I don't restart the service, but if I do restart the service after changing the config file, the source IP for the ModbusTCP comms then becomes the one for "enp1s0", which is very confusing to me: [SysSocket] Adapter.0.Name="enp2s0" Adapter.0.EnableSetIpAndMask=1 On the device list, I only have "enp2s0" given as the ethernet device that has the ModbusTCP master & slave beneath it, shown in Screenshot 1. On the IPC, I can ping the ModbusTCP client (remote I/O) from "enp2s0", and I've attached a Wireshark capture of running ModbusTCP from the CODESYS runtime as Screenshot 2, 3 & 4 (again, I can't get online when this is running, I have to turn off "enp2s0" to connect even when it's idle and I don't have an active TCP session with my Python tests). Like I explained above, the source IP is "enp1s0", even though the ethernet device on the project is "enp2s0". I was lucky to catch the red message that showed the source IP that makes sense to me (the one for "enp2s0"), but for some reason that connection was reset and I never saw that packet again. I've also tried this with Auto-reconnect both enabled & disabled, for the ModbusTCP Master device. I also have to turn off "enp1s0" and then turn it on, just so that I can have the ModbusTCP comms running from "enp2s0" (which is not intuitive in any way to me, I'd love some help understanding that phenomenon as well) in the weird manner that I've described above. I would be very appreciative if someone can help me figure out this pickle. I'd love to just connect to CODESYS through my Wi-Fi interface and leave my ethernet ports for field comms.
Last updated: 2024-08-01

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23

Post by jinlee on Symbol Configuration CODESYS Forge talk (Post)
Hi guys, I am working on an old project which using Codesys v2.3 talks to Beijer's screen TA150 (IX-Developer 2.20). Codesys v2.3 is different with 3.5 and Ecockpit. I know how to import the symbols from PLC to HMI for Codesys 3.5 and Ecockpit. However, I do not know how to do it on Codesys v2.3. I know that I can make excel sheet to import and export from the HMI and add whatever I want based on PLC. However, is there any quicker way of doing this? So that I can directly import the symbols (tags) from PLC (Codesys 2.3 to HMI).
Last updated: 2023-08-29

Post by ofey on Modbus TCP communication CODESYS Forge talk (Post)
Hi! I tried setting up the PLC I'm working with (Beijer GN-9373) to connect to a modbus master running on a laptop. I have an ethernet connection (via USB-C to ethernet) between the laptop and the controller. I have tried following tutorial on how to set this up. I have added an ethernet device with the IP-address of the PLC. Further I added a ModbusTCP_Slave_Device with default settings. I get the error "Failed to open TCP Port: 1" when I try to go online with the PLC. Earlier I tested the exact same set up with the soft PLC from codesys. I can then read/write values correctly with the Modbus master i have running on the laptop. Hope anybody can help me with this, thanks in advance!
Last updated: 2023-10-06

Post by bahrt on Mapping GPIO and adding GPIO configurations CODESYS Forge talk (Post)
Hi I am about to configure ALL GPIOs on a Raspberry Pi 3 model B V1.2. It seems that I have limited understanding of why not all the IO’s become available with the corresponding mapped IO’s – the 'dwInUse' contains mapping of the inputs from GPIO0 to GPIO27. But 'dwInputs' are only showing GPIO0 to GPIO8 and GPIO15 as available inputs. These mentioned inputs work fine You will be able to watch the limited mapped IO activity here: https://drive.google.com/file/d/1zz4PBNBfRZBF2YkiJ2VQxw6L9MBVji7R/view?usp=sharing Can you please bring your best idea on why GPIO09 to GPIO14 and GPIO16 to GPIO27 state are zero in the dwInputs register? Thanks in advance. Best regards Andreas Bahrt
Last updated: 2023-11-16

Post by bahrt on Raspberry Pi GPIO mapping CODESYS Forge talk (Post)
Hi I am about to configure ALL GPIOs on a Raspberry Pi 3 model B V1.2. It seems that I have limited understanding of why not all the IO’s become available with the corresponding mapped IO’s – the 'dwInUse' contains mapping of the inputs from GPIO0 to GPIO27. But 'dwInputs' are only showing GPIO0 to GPIO8 and GPIO15 as available inputs. These mentioned inputs work fine You will be able to watch the limited mapped IO activity here: https://drive.google.com/file/d/1zz4PBNBfRZBF2YkiJ2VQxw6L9MBVji7R/view?usp=sharing Can you please bring your best idea on why GPIO09 to GPIO14 and GPIO16 to GPIO27 state are not active (at a fixed zero state) in the dwInputs register? Thanks in advance. Best regards Andreas Bahrt
Last updated: 2023-11-21

Post by dkugler on Management of a PLC network from a remote station CODESYS Forge talk (Post)
I would figure out, how to create a simple html webpage with 2 frames. One frame with buttons to select the plc. A second frame with hyperlink to the webvisu of the plc ("XXX.XXX.XXX.XXX:8080/webvisu.htm"). Selecting other PLC Button has to change the hyperlink in 2. frame. Costs only some time to figure out :-) Or setup a raspberry Pi with small visualization. Set up a button for each plc and add one browser element. Each button writes the URL of the depending plc to the URL setting of the browserelement. Costs 55€ for runtime licence and a Raspberry Pi.
Last updated: 2023-12-04

Post by orbis-tertius on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
Is there anybody can help me with the same problem? I have to migrate created project in ver.3.5.17.0 32BIT with runtime 4.7.0 to ver.3.5.20.0 64BIT with runtime 4.7.11.0 due to the new license. All the libraries and dependencies are updaded and there are no any errors. The first compilation and loading to the controller is being compleated well. After this being done and if I am forced to change any values or change any code in the current project, another compilation will be freezed. This problem can be solved if pressed Build/cleen or cleen all. There is another method to solve this; if project is loaded with excluded object (Alarm Configuration), repeated compilations will be done well.
Last updated: 2024-06-27

Post by rcanfield on Code Coverage and Test Manager CODESYS Forge talk (Post)
I am exploring the possibility of measuring test coverage using the Test Manager and Profiler tools. It appears there are some significant limitations. Has anyone been successful trying to use these tools? Here are my observed limitations. Am I misunderstanding anything? * Profiler only works for one "run cycle". Even warm resets will clear the coverage calculations. Thus, all tests would have to manually reset values when complete to prevent contamination to other tests. * It is not possible to see which statements were/weren't executed. One would have to use the flow control tool which cannot be used in conjunction with the Profiler, and must be viewed in realtime. * The profiler control cannot be automated and therefore must be executed through a manual procedure. Thank you!
Last updated: 2024-07-11

Post by rcanfield on Code Coverage and Test Manager CODESYS Forge talk (Post)
I am exploring the possibility of measuring test coverage using the Test Manager and Profiler tools. It appears there are some significant limitations. Has anyone been successful trying to use these tools? Here are my observed limitations. Am I misunderstanding anything? * Profiler only works for one "run cycle". Even warm resets will clear the coverage calculations. Thus, all tests would have to manually reset values when complete to prevent contamination to other tests. * It is not possible to see which statements were/weren't executed. One would have to use the flow control tool which cannot be used in conjunction with the Profiler, and must be viewed in realtime. * The profiler control cannot be automated and therefore must be executed through a manual procedure. Thank you!
Last updated: 2024-07-11

Post by alez on CANopen safety , SRDO error behavior CODESYS Forge talk (Post)
I have a project in which there is a Safety device in CANopen, and the PLC interfaces with it as Master. I would like to understand if it is possible to set the behavior in case one of the SRDOs that I receive from the slave is no longer received. From what I have seen, if the SRDOs are not received, the CANopen safety status becomes "Not in progress" and the mapped variables freeze at the last value detected. I want to understand if it was possible to set the variables connected to the SRDOs to take a default value (e.g. zero) in the event of a CANOpen error during reception.
Last updated: 2024-07-15

Post by drml on How to implement an interface (IElement)? CODESYS Forge talk (Post)
I'm struggling with the implementation of the IElement interface (in the ElementCollections library), which I will use to create a SortedList. I created a class (FB) "Device" that implements this interface and that has a "Priority" property that I want to use in order to compare the devices in my implementation of the ElementCompareTo method. Unfortunately, the IElement.ElementCompareTo method needs an IElement as an input, which doesn't know about the "Priority" property of "Device". I tried to define the input itfElement as a Device, but then it doesn't want to compile, because the type in the implementation doesn't match the interface.
Last updated: 2024-07-19

Post by peterned on Array to String CODESYS Forge talk (Post)
max. string length in Codesys is 255 chars. It's not possible to cram 20,000 things in a string. If you need to send the data to another device, send the whole data[] array (as byte array, without doing anything to it) and extract the information on the other end. As each struct member has a fixed size (81 bytes, as per you declaration), this will be easy. To save some resources, consider declaring string lengths - e.g. if the max possible length for key is 10 chars, declare it key: STRING(10); and it will occupy 11 bytes instead of 81
Last updated: 2024-07-20

<< < 1 .. 132 133 134 135 136 .. 236 > >> (Page 134 of 236)

Showing results of 5888

Sort by relevance or date