Post by nano on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
i know, this is the reason for us either. PLC-Handler is to big, and only available with additional Contracts/Costs. OPC-UA is to slow for us. As described, there is a solution available, but im not allowed to post them here. i would prefer you send a message at codesys store by "have a question" or similar called. Not sure. Or, if an Codesys-Official Member allows to share that informations, i can give you the right hints.
Last updated: 2024-06-15

Post by arcadium on TargetVisu element stacking on top of each other CODESYS Forge talk (Post)
Hello, I'm new here so if I do something wrong please bare with me. I am using raspberry pi touchscreen made by comfile (CPi-C070WR4C). I also have a window 11 pc where I would like to have a second visualisation, but when I run a TargetVisu with it, all elements of the visualisation end up in the top left corner stacked on top of each other. I have same results running targetVisu on my laptop. Maybe someone had same issues and know the solution? Simas
Last updated: 2024-06-17

Post by rabaggett on No Visu on RasPi CODESYS Forge talk (Post)
OK, I got this to work as shown above in mos89p's comment. What I did: Tools/Update Raspberry Pi. Reloading the runtime seems to have solved the web problem. I can view the visualization on the Pi and laptop using a browser as shown above. Thanks! But Isn't the visualization supposed to take over the screen of the Raspi? When I run visu projects on Windows or Wago, the visualization shows on that device's screen by default.. But this is not happening in this case
Last updated: 2024-06-20

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
Just to share, for those who as me are seeking for this and had found no information anywhere in this World: Every time I stop/start the PLC runtime ( turning into 'Stopped' or 'Running' state ) the 'CODESYSControlService' appears at the Taskmanager list, which could suggest a straight correlation. I was expecting a clever solution, but this one solves for while.
Last updated: 2024-07-02

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
It's already there, the service get started as default. I missed to say that sometimes it happens w/o even the system get restarted. Anyway, the main issue here is to know the state of the runtime. We collect a lot of informations about the whole system, and it would be nice to have a way to detect the runtime state.
Last updated: 2024-07-02

Post by nano on Issues with Modbus Slave with Raspberry Pi CODESYS Forge talk (Post)
in the codesyscontrol.cfg or codesyscontrol_user.cfg you have to declare whoch comport-ports from runtime are used. please tell us how the comport is called in linux an post the codesyscontrol.cfg files also write down here, which parameters are used in the python-script and what is parameteized in the modbus-master-comport of your codesys-application. mostly the errors occurs in ine of these areas
Last updated: 2024-07-11

Post by kislov on Change modbus server parameters from program CODESYS Forge talk (Post)
Use in IEC-code: Modbus_Serial_Device.UpdateComPortSettings(...) https://content.helpme-codesys.com/en/libs/IoDrvModbusSerialSlave/Current/pou-ModbusSerialDeviceDiag/UpdateComPortSettings.html Take note: "Only possible if server is disabled (see xEnable Input)" So: Modbus_Serial_Device.xEnable := FALSE; Modbus_Serial_Device.UpdateComPortSettings(...) Modbus_Serial_Device.xEnable := TRUE; Please note that after PLC reboot the values from the GUI (from your screenshot) will be applied again. So you need to save values from HMI in RETAIN and restore them after start of application.
Last updated: 2024-07-17

Post by mubeta on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Yes, this point is part of my misunderstanding. Why, after the execution ot the motion FBs is set to FALSE and exsecuted at lest one time, it must be continuosly called, even if the motion control it's take from another subsequent instruction. This is what I really don't undertand, but what in fact it's happening. For example, in case of stopping a MoveVelocity FB, then Halting the motion by the related FB, the axis at spot goes into error. If there was bad trigger management, the various instructions would NEVER work.
Last updated: 2024-07-18

Post by mikek10 on Error IoDrvEthernetIP: Connection Failure. (16#1) How to solve CODESYS Forge talk (Post)
Make sure the number of bytes matches the values in the Ethernet/IP>Assembly Information section of the Wagos web management page (expand by clicking on the +). The EDS file will probably have defaulted to assemblies 101 and 104. If you want a different assembly there is an article that tells you how to modify but seems to be unavailable at the moment. An alternative is to modify the .eds file to change the default assemblies.
Last updated: 2024-07-22

Post by mase on Python script: Launch Codesys, Execute Script, Exit Codesys CODESYS Forge talk (Post)
Hi, sorry I can´t help you with your issue, but I hope you can give me a hint on getting GUID for other objects than POUs. Your code states "Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08")". We can I find the GUID / ObjectIds`? I wasn´t able to get details about the GUID of DataTypes (STRUCT/ENUM,..)m, Functions (FUN), GLOBALS and TYPES. I want to create markdown of all available project elements. Thanks for your help
Last updated: 2024-08-06

Post by narius on OPC-UA object instances preexisting in imported xml information model CODESYS Forge talk (Post)
Hi all, is it possible to use object instances that are not instantiated by codesys itself, e.g. have been defined in UA-Modeler ? When I browse the plc with UA-Expert I see those instances, but I have not seen information in codesys or the web if these are writable in codesys. So far, I am under the impression, that it is not possible, but would like to hear from others. Also, is it correct, that it is not possible to create references inside codesys ? Thanks in advance and kr
Last updated: 2024-08-08

Post by trusty-squire on How to adapt Codesys Control SL to custom board CODESYS Forge talk (Post)
For general usage, these links might help you out. If you are looking at using I2C interfaces, examples from the Raspberry Pi will probably be useful, even if your board isn't a Raspberry Pi. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_rts_serial_com.html https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_raspberry.html If you're developing your own drivers, I can't help you there, although the link you provided will help. If you drill in deeper, the I2C page for example shows function block and method usage, etc. Good luck!
Last updated: 2024-08-09

Post by micik on ERR_OK not recognized CODESYS Forge talk (Post)
Hello, if I try to use ERR_Ok in my code to check whether the file is open correctly or not, I get an error "Identifier ERR_OK not recognized", I can use plain 0 (zero) instead. But in general, is this a proper way to check for success of file operation since the 4th parameter is a poinmter to RTS_IEC_RESULT, and normally I would expect this to be used somehow. _hFile := SysFileOpen(_sFileName, am:=SysFile.ACCESS_MODE.AM_WRITE, ADR(_result)); IF _result <> 0 THEN udDiag := 100; RETURN;
Last updated: 2024-08-17

Post by carohe on %t SystemTime in Variable CODESYS Forge talk (Post)
Hello, if you enter %t as a "Text" on a rectangle and do not link a variable in "Text variable", it automatically displays the system time. My question is, where do if find a variable, that contains exactly this time? I tried numerous variants using GetLocalDateTime or GetSysTime but I always have to manage timezones myself (which I do not want to do). I only want a variable with the date an time from my windows system, where the visualization is running. Where can I find this variable?
Last updated: 2024-08-20

Post by richiemuia on Static Analysis, Loading Files via script. CODESYS Forge talk (Post)
I've seen that you can use cmds like below to run SA from scripts. system.commands["staticanalysis", "run"].execute() But I would like to run different SA configuration files to create separate logs and cant find anywhere in the scripting engine if this is supported. This stems from if I turn on everything, SA stops reporting issues in the message log when the list gets over 600ish issues. Once we have done an initial clean up of code this wont be an issue, but I'm trying to get a baseline to track improvement.
Last updated: 2024-08-21

Post by richiemuia on Static Analysis, Loading Files via script. CODESYS Forge talk (Post)
I've seen that you can use cmds like below to run SA from scripts. system.commands["staticanalysis", "run"].execute() But I would like to run different SA configuration files to create separate logs and cant find anywhere in the scripting engine if this is supported. This stems from if I turn on everything, SA stops reporting issues in the message log when the list gets over 600ish issues. Once we have done an initial clean up of code this wont be an issue, but I'm trying to get a baseline to track improvement.
Last updated: 2024-08-21

Post by szotyi on Array of Program CODESYS Forge talk (Post)
Hi! What is the proper and the easiest way to call programs through looping of array of programs, or pointer of program? instead of calling the programs one by one: prog1(inputX: 11); prog2(inputY: 12); prog3(inputZ: 13); similar like: VAR programsToCall : ARRAY [1..3] OF PROGRAM; END_VAR programsToCall[1] := prog1(inputX: 11); programsToCall[2] := prog2(inputY: 12); programsToCall[3] := prog3(inputZ: 13); FOR i := 1 TO 3 DO programsToCall[i] (); END_FOR Thanks.
Last updated: 2024-08-28

Post by pradeepradha on Update Raspberry Pi option is missing under Tools menu CODESYS Forge talk (Post)
Hello, the option to update Rasberry Pi from under the Tools menu is missing in my installation. Currently I have the build 3.15.19.50, along with the Pi package 4.11.0.0. But the same problem is observed even with the latest build and Pi packages. I have tried clean install with both the versions but cannot solve the issue. I never faced this on Windows 10, but now the new PCs are with Windows 11 - this is the only difference. How can I solve this problem?
Last updated: 2024-09-02

Post by hbuitrago on CmpIecTask-program loaded exception CODESYS Forge talk (Post)
I'm facing an error that show on the codesys and the PLC that dont let either the PLC run or access it using the remote software, Error: program loaded exception Log: exception position:IP=0x0xfffffffe (no IEC context could be retrieved) component: CmpIecTask exception [accessviolation] ocurred: APP=[application], Task=[Task] POU changed, that inhibits an online change, Plase let me know if there is a solution for this issue, Best regards,
Last updated: 2024-09-06

Post by docker on Webvisu client connection monitoring CODESYS Forge talk (Post)
Hi mate, With this snippet i was able to see the lastusage variable count, but it would not iterate between clients? i was only able to access the data of the target visu. it threw an error with the array of pointers stating it was not able to convert etc. also when i tried it with the while loop it created an endless loop and crashed the program. any ideas? Thankyou
Last updated: 2024-09-10

Post by trprsmn on "Scan Network" doesn't find CR1140 device (ifm) CODESYS Forge talk (Post)
Hi, I'm watching an ifm tutorial on how to setup an industrial controller in CODESYS. I'm using an 'ecomatDisplay43inch_64bit) controller. CODESYS Gateway and PLC are both runngin (systray). However if I click "Scan Network" I can't find my controller. The only thing it finds is a "desktop" it seems (I'm using a Windows 10 on a Mac Book using VMWare, so maybe it has something to do with that?). How can I fix this? Thanks in advance!
Last updated: 2024-09-11

Post by dkugler on TargetVisu Freezing CODESYS Forge talk (Post)
The only weird situation i remeber with particular or complete frozen target visu was after the rtc clock was fallen or set back to the past. It looked like after running a while the alarm history database crashed during writing entries at a date lot of years in the past. After setting the rtc clock to actual date/time and deleting the alarm db every thing worked fine. I don't know, if this is/was a problem of our PLC hardware/firmware? Maybe check date/time at your system?
Last updated: 2024-09-13

Post by jinlee on Camera RTSP Feed CODESYS Forge talk (Post)
Hi, I followed your guidance and used go2rtc. There is a link generated from go2rtc I can copy into the web browser element in the visualisation. It somehow only appear within the software when it is running, but not on the webvisu. I want to display the camera feed onto the webvisu. My camera is reolink 810a which supports IP protocol. My project is pretty simple, just a web browser element with assigned URL.
Last updated: 2024-09-17

Post by dkugler on EThercat Dynamic configuration CODESYS Forge talk (Post)
I can confirm that at my 4ms EtherCAT Master the frames per second is equal at round about 500 with Codesys SP19. The same program at SP16 it was at 380-430 f/sec. for me it will be interesting too, whats the reason is for this high frame count/sec? I havn't had the time to use a paket sniffer and analyse all the frames. I can't help with your other questions, sorry.
Last updated: 2024-09-19

Post by george32 on Readable IO names CODESYS Forge talk (Post)
Hello Folks, I have a quite basic understanding of how PLC programming works. However I keep getting stuck on 1 problem I could not get my head around. The problem is as follow: I have a PLC with 60 IO (20 inputs, 40 outputs). Each IO is defined as a function block. Furthermore I have an external IO card connected trough a CanBus connection. This IO card has 4 analog input channels (USINT), 4 digital inputs (Bool) and 4, digital outputs (Bool) Because I have 2 different components which both has data have I made 4 arrays to store the data off every component in one variable. PLC_Input: Array [1..20] of BOOL; PLC_Output: Array [1..40] of BOOL IOCard_Input: Array [1..8] of BOOL IOCard_Output: Array [1..4] of BOOL Because the control and reading of the different in and outputs is done by a TCP connection I want to use some kind of enumeration or struct to give each index a name so that my main would be a little bit more readable instead of all the magic numbers. Also this would make my program more dynamic for the furter in case I need to changes some in the IO nummers. For example: pump is placed on the fysical terminal strip number place 54, which is the 3th output of the IO card in the program: if I am sending a message with value 54 I would like to control IOCard_Output[3]. If there is a solution or methode to get this done, I can eventually do the following in my main program: IOCard_Output[Pump]. I have tried the following: IOCard_Output[Pump - 51] with an enumration but this keeps raising an error I hope some of you could help me further with this problem. In gross lines: I want to couple all the different IO to a more readable name and this readable name should control the right Array index Thanks in advance, George
Last updated: 2024-09-26