Post by timvh on Alarm Configuration Notification Action
CODESYS Forge
talk
(Post)
If it is a BOOL, then use: ...Error_Active := ALARM BOOL: ALARM INT: STATE
Last updated: 2024-05-14
Post by eschwellinger on Problems with Raspberry Pi - IoDrvGPIO library
CODESYS Forge
talk
(Post)
this is only a precompile error, will be solved but you ignore it works without any problem
Last updated: 2024-05-14
Post by wiresplus on How to display the application name on a visualization (V3.5.16)
CODESYS Forge
talk
(Post)
Intetrested... I added the CmpApp library, but cannot find the AppGetApplicationInfo you mention.
Last updated: 2024-05-15
Post by totorovic on How to display the application name on a visualization (V3.5.16)
CODESYS Forge
talk
(Post)
https://forge.codesys.com/forge/talk/Engineering/thread/1203efe4d8/
Last updated: 2024-05-16
Post by andrax on Recipe Manager - Not Creating Recipe Files
CODESYS Forge
talk
(Post)
Hi, i had the same problem. have a look here: https://forge.codesys.com/forge/talk/Runtime/thread/6b9e48d29a/
Last updated: 2024-05-21
Post by eschwellinger on Licensing info not available.
CODESYS Forge
talk
(Post)
we recommend to do it with the official virtual plc version..will send a version.
Last updated: 2024-05-23
Post by ndzied2 on Rounding error in simple addition
CODESYS Forge
talk
(Post)
Ignore, was duplicate post. Can't find a way to delete it.
Last updated: 2024-05-24
Post by dhumphries on Rounding error in simple addition
CODESYS Forge
talk
(Post)
Thanks for the response, as I've thought about this problem over the last month I began to suspect this was a problem with not being able to exactly represent .1 as a 32 bit binary number. I think I've found a work around by making the number an integer, then dividing it by 10 and storing that value as a floating point number. There is still an issue with the value not being exact somewhere in the 8th or 9th decimal place, but because I'm incrementing an integer value then dividing it, the error doesn't compound.
Last updated: 2024-05-25
Post by ppix on MQTT PLC Chat:
CODESYS Forge
talk
(Post)
Did you ever find a solution to this? I am having the same issue but using TLS connection.
Last updated: 2024-05-26
Post by automa on How to write variable by name
CODESYS Forge
talk
(Post)
It has been a few years since this topic. Any solutions?
Last updated: 2024-06-04
Post by ragarcia on How to change login visualization for other visualization after user logged in
CODESYS Forge
talk
(Post)
Hello everyone, I have a web visualization on Codesys and to be able to use the web visualization first an user and a password is requested. After the user logged in, I want to automatically change the visualization to the 'Home' visualization but I am not sure how to do this. In the login visualization I basically have a button with the input configuration to execute the action 'Login' after a click. Once the user is logged in, the visualization is still stuck in the login page and I want to automatically change to Home visualization if the user was succesfully logged in. How can I know the number of web visualization clients connected to my PLC? Thanks in advance
Last updated: 2024-06-04
Post by codesysdave on Using globals without a prefix (bMyTag vs GVL.bMyTag)
CODESYS Forge
talk
(Post)
Over 5 years later, you helped me tremendously. Thanks. And great kitty picture.
Last updated: 2024-06-04
Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10
Post by martinlithlith on Raspberry Pi: List of available drivers / libraries
CODESYS Forge
talk
(Post)
hi! this sounds awsome! Sorry for a perhaps stupid question; how do i find you're collection?
Last updated: 2024-06-11
Post by paro on Which Lib to use, connect to a socket with URL instead of IP address
CODESYS Forge
talk
(Post)
hi, maybe Net Base Services https://forge.codesys.com/prj/codesys-example/nbs/home/Home/
Last updated: 2024-06-17
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
Hello, CODESYS Control is running on my RevPi, and my system communicates over a CANbus with a master using the ConnectCan module (Slave - CANopen Device). The communication works perfectly fine so far. However, as soon as I call a Python script with "SysProcessExecuteCommand2" that creates a CSV file and executes without errors, the master does not adopt any changes to the Transmission Process Data Objects (TPDOs). I don't quite understand what one has to do with the other, and perhaps someone can help me with this. Here is my script call: SysProcess.SysProcessExecuteCommand2(pszCommand:='python /home/pi/test.py', pszStdOut:=sCMDOutput, udiStdOutLen:= SIZEOF(sCMDOutput), pResult := ADR(eResult)); Thank you in advance! Best regards, Stefan
Last updated: 2024-06-20
Post by rohan on Child Application Alarm
CODESYS Forge
talk
(Post)
Hi All, I'm trying to develop a multi-application project that allows me to switch between applications. I currently have a parent application and several child applications, as this is the only way for them to share CAN/Ethernet communication. I've noticed that I am only able to create an Alarm Configuration for the parent application. But the children application do not seem to be displaying alarms on the Alarm Table in the visualisation for when an alarm is raised. Does anyone know of a fix, solution or a way around this? I am utilising Codesys v3.5 SP16 Patch 5 64Bit
Last updated: 2024-06-21
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
I am now executing the process in a separate task with lower priority, but unfortunately, the connection to the master is still interrupted.
Last updated: 2024-06-21
Post by rafael on Wbm/runtime and visualization login
CODESYS Forge
talk
(Post)
Solved, there is a configuration inside the WBM where I can disable this login option (config>ports config)
Last updated: 2024-06-25
Post by ranadheer on Control Win SL licensing
CODESYS Forge
talk
(Post)
Hi johnlee and jeffgamsby Is Control win SL is a SoftPLc Extension SL
Last updated: 2025-10-18
Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27
Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27
Post by msegon on OPC UA Client failed to connect
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I'm trying to read data from Tridium Niagara 4.15 OPC UA Server, but I get the error BadCertificateInvalid. As far as I understand, you need to add a CA certificate somewhere to establish a secure connection, but I don't know where. 2025-10-27T09:06:43.247Z, 0x0000008d, 4, 0, 0, * ERROR: OpcUa_Channel_BeginConnect: Cannot create secure channel without certificates! 2025-10-27T09:06:43.247Z, 0x00001090, 4, 0, 0, * ERROR: Datasource: Error Failed (268468242) in state Connecting I tried communicating without encryption, but it doesn't find the point. Has anyone managed to establish encrypted OPC UA communication?
Last updated: 2025-10-28
Post by reinier-geers on check if Programm pc is online
CODESYS Forge
talk
(Post)
I did but then it turns out, codesys hangs its self vor 30 sec after a ping
Last updated: 2025-11-06
Post by albertovalente on How extract JSONElement containing Array data
CODESYS Forge
talk
(Post)
Hi Creator: hazarath, Have you fix the problem? because I have the same issue Thanks a lot