Post by codesysdave on CoDeSys 3.5 SP20 "No Offline Help installed"
CODESYS Forge
talk
(Post)
What does this message mean, in the Errors/Messages box? "[ERROR] MyProjectName: No Offline Help installed" In CDS23, I used to be able to select a system function with the mouse, and press F1. Help and description would popup. How do I get so-called On-line Help installed?
Last updated: 2024-09-06
Post by csu-chris on Colors look different when logged in and running
CODESYS Forge
talk
(Post)
I am running CODESYS V3.5 SP19 Patch 2 (64-bit) I have buttons that are supposed to be either red or green depending on status. When I am logged out the colors look right. When I am logged in and running the colors are completely different and I can't understand why.
Last updated: 2024-12-06
Post by jcarter on Webvisu Combined Authentication
CODESYS Forge
talk
(Post)
Is there a way to have both a Public No Login Screens with Screens that do require login and File Transfer? My Idea is to have the default page be View Only with a Login Button in the Corner and then Once Logged In you can change settings and download files depending on your user group.
Last updated: 2025-08-28
Post by nz-dave on Bool turning on in case stament in wrong state?
CODESYS Forge
talk
(Post)
pretty sure its not. ive done a cross reference and only have one write that sets it to true. Only way i can stop it is to remove the function block call from the main pou that is running said case. its got me stumped:/
Last updated: 2023-12-16
Post by timvh on Sysfile inuts
CODESYS Forge
talk
(Post)
To prevent ambiguous use of this enumeration value. Let's say another ENUM is available in your project or in another library which has an enumeration value AM_WRITE, then it is not clear which AM_WRITE you want to assign. By this qualified access to the SysFile.AM_WRITE, it is completely clear for the compiler.
Last updated: 2024-01-14
Post by ferrim on IEC 61499
CODESYS Forge
talk
(Post)
Hello otdeveloper, I am very interested in this topic. I have been dedicated to IEC 61499 for some time and I would like to understand if the time has come to adopt it in the real world of automation or if it will continue to fill up research papers only.
Last updated: 2024-02-09
Post by gurkan on OPCUA array max length?
CODESYS Forge
talk
(Post)
We are using codesys 3.5.16.30 and we have a array with strings of length 5000. We are having issues subscribing to this variable from an OPCUA client. Is there any limit in the OPCUA Server in codesys for how long an array can be on the opcua server?
Last updated: 2024-02-16
Post by alexgooi on Init Array input on a method
CODESYS Forge
talk
(Post)
Dear Forum, I would like to initialize an array input on a method. When I do this, I get the following error: "The type of ARRAY [1..2] OF BOOL cannot have a default value in this context." I attached a picture for more clarity. Is this simply not possible or is there a different way of tackling this problem? Thank you in advance
Last updated: 2024-02-26
Post by jaspergain on SoftMotion Axes issue
CODESYS Forge
talk
(Post)
Dear, We have an issue with SoftMotion and it's licensing. We don't use SoftMotion in this project. But a SoftMotion license is required by it. The License metrics tell's us there is a -1 Axes. Is there a way to reset this? Delete this? There was a MotionControl device in the project, but we have deleted this. But it stayed at -1. Thanks for you help.
Last updated: 2024-02-29
Post by dhumphries on Attempting customizing menus fails in LADDER environment; due to free CODESYS version ?
CODESYS Forge
talk
(Post)
You get fewer tools when you create a new POU and choose ladder diagram instead of ladder logic diagram. Create a new POU and select ladder logic diagram and you should find the additional tools you are looking for in the toolbox.
Last updated: 2024-03-11
Post by andrea1989 on sm3raspi-stepper.package adapt this to use in combo with GPIO generic
CODESYS Forge
talk
(Post)
Hi, I would like to create a project with nema 17 and raspberry with codesys. I'm using the sm3raspi-stepper.package which is brilliant but I cannot use the generic GPIOs while using this package. Would anybody help me with modifiyng this package in order to adapt it to my app? Thank you.
Last updated: 2024-03-12
Post by xabier on See only variable
CODESYS Forge
talk
(Post)
I have declarated this variable...When i use the variable I see all...I wan see only the variable not all. For example I declarated in GVL_GLOBAL ==> Torque_Mode When I push enter insert in code all rute..GVL_GLOBAL.Torque_MOde...I want see only torque mode...How is possible resolved this problem?? Thanks XABI
Last updated: 2024-03-14
Post by mos89p on how to use UseDataExpanding() in datasource
CODESYS Forge
talk
(Post)
Hi I need to update by software some structures in my datasource, i found this example: https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_update_data_interface.html it seems that because i use complex variable structure i need to use UseDataExpanding() instead of use data, the question is how to get an instance of IDatasourcesMgr3 i have the global variable g_Datasources is instantiated automatically
Last updated: 2024-06-18
Post by trannhantxqt on Tripod rotary coordinate is not correct with right hand rule
CODESYS Forge
talk
(Post)
Hi all, I work with tripod rotary kinematics in codesys robotics lib and I got a problem with WCS coordinate. My robot WCS dont look like right hand rule, you can see in the image. (WCS Y axis is negative) Anyone here get the same problem? :D It make me so confuse.
Last updated: 2024-06-22
Post by nano on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
which ports in detail are configured. the search of the rts works via broadcast-messages, programming with tcp-port on p2p-connection woth port-hopping, handled by runtime after siccesfully handshake. look at this entry on forge https://forge.codesys.com/forge/talk/Runtime/thread/4078a2ed28/
Last updated: 2024-06-23
Post by alex-at-xana on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
Hi Everyone, For a fast monitoring system I am using Ethercat oversampling and timestamping inputs. As the customers has a lot of different configurations out in the field, we went for a dynamic Ethercat configuration. Already got the whole detection chain working but now I am stuck since two days in debugging the configuration. Here are my quesitons: I extended the dynamic config example for the EL3632 16#0E303052: //EL3632 pSlave^.SetDCSettings(TRUE,TRUE,80,80,TRUE,4000,0,0); pSlave^.AddSyncManager(16#1000,128,16#26,TRUE,3); pSlave^.AddSyncManager(16#1080,128,16#22,TRUE,2); pSlave^.AddSyncManager(16#1100,0,16#4,TRUE,1); pSlave^.AddSyncManager(16#1110,214,16#20,TRUE,0); pSlave^.AddFMMU(0,214,0,7,16#1110,0,1,1); pSlave^.AddFMMU(0,1,0,0,16#80D,0,1,1); xKnown := TRUE; This leads to a PLL Error for these devices. I double and triple checked the configuraton, but cannot find the issue. There seems to be one difference: the config dialog creates a startup parameter: 16#10F3:16#05, Name: Command_0, Value:0. Bitlen: 16, Stop on fault: false, jumpt at fault: false: next line: 0 a) I do not find information on how to set this in my code. Can you help me there? b) Without trying to set the value, I get a PLL error for these devices in the master log. Is the config wrong? c) Do I need to set the Master to Autoconfigure or Manual? I used autoconfigure for my tests. The stack creates input data addresses for the slaves input data range (pSlaves[i].InputData) which are different from those created when I use the Engineering tools dialogs to configure Ethercat. Specifically, the addresses seem to be aligned at 16 byte boundaries when they are created using the engineering tool, but may appear at uneven addresses when I use the script in dynamic config. I did not try to access ULINT at uneven addresses yet, but I am suspecting this may be a problem. Do I need to manually align the addresses ? Any help is appreciated...
Last updated: 2024-09-10
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by thewizard8 on Raspberry PI4 Serial Port
CODESYS Forge
talk
(Post)
Hi Dear All, I'm using my raspberry PI4 as a CoDeSyS PLC (Build from scratch with custom electronics). I was able to implement all fieldbuses with the exception of Modbus Serial. I'm using the internal Port (GPIO) and I configured it in /etc/Codesyscontrol_user.cfg the following away: [SysCom] Linux.Devicefile.1=/dev/ttyUSB0 Linux.Devicefile.2=/dev/ttyS0 I'm using COM2 on Master configuration. I'm using a interface board from TTL/RS485 (bidirectional board), and it's works perfectly with other devices but not in CoDeSyS. I'm able to send data with python script and read it on my pc using putty, but when I use a modbus slave simulator to interface with codesys I always get red icons on master and slave. (Please find image attached). I'm pretty shure that this might be a bad parameter on my CoDeSyS runtime configurstion file. Can someone help me? I'm stuck and this is for my master degree certification.
Last updated: 2024-03-18
Post by timvh on gateway problem
CODESYS Forge
talk
(Post)
Maybe select the local gateway instead of the gateway on the remote device?
Last updated: 2023-08-31
Post by eschwellinger on Generic EtherCAT slave
CODESYS Forge
talk
(Post)
Sure, import the ESI file, scan the slave access the PDOs.
Last updated: 2024-05-14
Post by vformanek on How to access files correctly in Linux
CODESYS Forge
talk
(Post)
Hello, its still not quite clear to me how to deal with the PLCLogic directory in linux. I have the directory right here: I need to correctly access the files in this folder through CODESYSControl.cfg. Here is my CODESYSControl.cfg where on the first lines there are a few lines: [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 That means that if I am going to use relative paths its going to go to from the PLCLogic directory right ? For example here: Whitch paths should I use. I cant seem to successfully run any of these aproaches ...
Last updated: 2023-09-08
Post by wbj0t on Global variable access by Programms and Modbus Devices (attach device to bus)
CODESYS Forge
talk
(Post)
Hi everyone. I use Raspberry Pi 4, one core codesys SL. I have a question about global variable access via programm when I glued the same variable to MODBUS SERIAL/TCP DEVICE holding register. So, the question: what behavior of this modifying? When I set "Always update variables (in bus cycle)" and set some task as bus for the Device, then in another task I cant change this varible (can, but immediatly the old value setted again). But the same things works with MODBUS SLAVE: again "Always update..." and master attached to some task, then I change variable in another task and all works. I cant set up my variables from retains file at PrepareStart event because of this behavior with MODBUS SERIAL/TCP DEVICE. Thanks, wbj0t.
Last updated: 2024-07-18
Post by andrebrandt on FB string and naming
CODESYS Forge
talk
(Post)
Thank you so much. This worked. Waht im trying to do here is to automatically tag each sensors, valves and so on. There is a preatty nasty tag system i working on. "_320" is not alloved. I can have a tag "+4f=320.004-RT001V" In codesys I want to build the FB in folders. -4f | --320 | --001 This is the system structure. Inside here is all of the sensors and so on. But with Codesys, I cannot tag this like this. So what I'm trying to do now is to Make a folder for the building "4f" and one for the system "320", and a POU _001. Is there a way in init to get folder names?
Last updated: 2024-10-01
Post by ben1 on Help understanding analog in-/outputs
CODESYS Forge
talk
(Post)
Hi there mate Most PLC's have a very similar concept with AI/AO - have you used any other software before? I have not used a Wago before myself, but I assume the concept would very much be: 1. Add the analog in & out cards to your hardware config. 2. Setup the raw input scaling on the hardware (eg. 4 - 20mA = 4000 - 20000) 3. Use a built in or homemade scaling block to scale your input as needed (eg. 4000 - 20000 = -100 - 2000kPa. 4. Write code as required 5. Scale output as needed (eg. 0 - 100% = 0-10000 = 0 - 10V) Is this the information you require?
Last updated: 2024-12-15
Post by pernockham on *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv
CODESYS Forge
talk
(Post)
*** The system may be in an inconsistent state, please reboot *** *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv Every time at the instant that I Login to the system a message that the "system may be in an inconsistent state, please reboot" is written in the log. If I logout and repeat login a new entry is set. My system is a "Control for linux SL" running on a debian linux host. Im running it on my desk without any IO attached so message might be caused from that, but I doubt i have seen it before. Rebooting makes no difference. Anyone that have a clue of how I should interpret this error message?
Last updated: 2025-09-26