Search talk: i/o drivers

 
<< < 1 .. 134 135 136 137 138 .. 142 > >> (Page 136 of 142)

Post by pernockham on How to recognize licenses SMALL, MEDIUM, LARGE by CmpCodemeter CODESYS Forge talk (Post)
Im trying to read out active license by CmpCodeMeter but am not sure of the combination of ProductCode and FeatureMap that each of CONTROL, VISU and COM / SMALL, MEDIUM, LARGE equals. Started by trying CodeMGetContentByFirmcode (and productCode) expecting error 18 / Not Available if asking for a higher level of license compared to what I know is active, but function just returned the requested productcode and a featuremap Is this the way or is it better to use CodeMOpen? Which seems to also require a featureCode. Where can I find info on required featureCode? ProductCodes according to google: Control (PLC Runtime) Small (S) 16#00002FFF 12287 * Medium (M) 16#00003000 12288 Large (L) 16#00003001 12289 Visualization (WebVisu) Small (S) 16#00003002 12290 Medium (M) 16#00003010 12304 * Large (L) 16#00003003 12291 Communication (Com) * Small (S) 16#00003004 12292 Medium (M) 16#00003005 12293 Large (L) 16#00003006 12294 Thanks!
Last updated: 2026-10-06

Post by gseidel on Mismatch between coordinate monitor and actual motion using SMC_GroupJog2, MC_MoveLinearAbsolute (6DOF) CODESYS Forge talk (Post)
Hi darwin01, looking at the video and comparing the movement with the first figure in https://content.helpme-codesys.com/en/libs/SM3_Transformation/Current/SM3_Transformation/Function-Blocks/Standalone-Kinematics/Articulated-Robots/6AxisArticulated/Kin_ArticulatedRobot_6DOF.html, I think that the direction of rotation does not match between the RoboDK model and the CODESYS 6DOF kinematics. In the CODESYS kinematics, A1 and A2, when moved in positive direction, rotate into the opposite direction to what the RoboDK model does. This could explain the strange movements. For real axes, you could change the direction using the "Invert direction" flag of the scaling/mapping page. For your simulation, you could manually invert the position of the axes A1 and A2 before sending them to RoboDK. (A0 seems correct, please also check A3, A4, and A5. The figure I mentioned gives the order of positive rotation with arrows through the joints. You can use the right-hand-rule to see what the positive rotation is.) Best regards, Georg
Last updated: 2026-10-12

Post by animesh on SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP CODESYS Forge talk (Post)
Hello everyone, I am facing a persistent issue with the OPC UA Server on Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) and need help from the community. Device Information Name: Advantech Control x86 RTE V3 x64 Vendor: Advantech Co., Ltd. Categories: PLCs Version: 3.5.20.10 Description: Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) Problem Summary The OPC UA Server works perfectly when accessed via: opc.tcp://localhost:4842 opc.tcp://<hostname>:4842</hostname> But it does NOT work when using the LAN IP: opc.tcp://192.168.0.XX:4842 In UAExpert I get: Discovery FindServers on opc.tcp://192.168.0.XX:4842 failed (BadCommunicationError) Port is LISTENING in windows Firewall.. Tried with turning off the firewall completely. System Information Windows 10 x64 Advantech CODESYS RTE Soft-PLC (hard real-time) Network IP: 192.168.0.XX Hostname: WINDOWS-XXXXX Need your Support
Last updated: 2025-11-24

Post by kiranbsiddaiah on CodeSys OPC UA client Unable to Connect To OPC UA sever through Username and password CODESYS Forge talk (Post)
Hi, I'm using codesys v3.5 sp21 software. I have downloaded the sample opc ua client project from https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_uacapi_example.html and i tested connecting to "prosys opc ua simulation server". Through Anonymous connection it is connecting to server and can read data. Later tried to connect using username and password. First got a SECURITY_CHECKS_FAILED error, trusted the client certificate in the server and this issue resolved. Next got an INVALID_CERTIFICATE error, trusted the server certificate in the client and this issue resolved. After these two error it is not establishing the connection and not giving any error messages. UAAsyncProp: UA.AsyncProperty := (tnTaskName:='UAClientTask', usiTaskPrio:=20, udiTaskInterval:=10000); UAPolicy: UA.SecurityPolicy := (sPolicy:=UA.OpcUa_SecurityPolicy.OpcUa_SecurityPolicy_Aes128Sha256RsaOaep, eSecurity:=UA.SECURITY_MODE.SIGN_AND_ENCRYPT); //UAPolicy: UA.SecurityPolicy := (sPolicy:=UA.OpcUa_SecurityPolicy.OpcUa_SecurityPolicy_None, eSecurity:=UA.SECURITY_MODE.NONE); UAAuth: UA.UserNameAuth := (sUserName:=UAVars.sUser, sPassword:=UAVars.sPass); UAClient: UA.Client := ( itfAsyncProperty:= UAAsyncProp, //sClientName:= 'MyOPC UA client name', //default: ‘CODESYS OPC UA Client’ sURL:= UAVars.sURL, sSession:= UAVars.sSession, itfPolicy:= UAPolicy, itfAuth:=UAAuth, udiTimeout:= 100000 //,itfNamespaceArray:= UAVars.itfNamespaceArray //optional use ); ----------------------------------------------------------------------------------------------------------------------- Please let me know if any additional information required. Thank you...
Last updated: 2026-05-07

Post by charly29160 on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21 CODESYS Forge talk (Post)
Hi, after updating CODESYS Control for Raspberry Pi SL from patch level 18 to 21 (currently 4.21.0.0), the IoDrvGPIO driver ("GPIOs B+/Pi2") can no longer open any GPIO chip on a Raspberry Pi 5. Log output on login: Could not open GPIOChip0. Access to path /dev/gpiochip0 not allowed. Add /dev/gpiochip0 to permitted paths in configuration file if required Could not open GPIOChip4. Trying to open GPIOChip0 Access to path /dev/gpiochip4 not allowed. Add /dev/gpiochip4 to permitted paths in configuration file if required Could not open any GPIOChip. System details: Raspberry Pi 5, 32-bit Raspberry Pi OS (armv7l), kernel 6.12.47+rpt-rpi gpiodetect correctly shows gpiochip0 [pinctrl-rp1] (54 lines) as the RP1 GPIO controller Runtime: CODESYS Control for Raspberry Pi SL 4.21.0.0, Runtime Toolkit SP21+ This worked without issues before the update to SP21. I've tried adding the following to CODESYSControl_User.cfg without success: ini[CmpCharDevice] Linux.DevicePath.1=/dev/gpiochip0 Linux.DevicePath.2=/dev/gpiochip4 Could you tell me the correct section/key to whitelist /dev/gpiochip0 (and /dev/gpiochip4) for CmpCharDevice? I suspect this is part of the general security hardening introduced around SP21 (similar to ForceIecFilePath for SysFile, or the new Gateway "accept local clients only" default), but I couldn't find it documented anywhere. Thanks in advance!
Last updated: 2026-07-19

Post by imdatatas on CFC editor: enable inline value entry on unconnected input pins (as in Ladder Logic editor) CODESYS Forge talk (Post)
In the CODESYS Ladder Logic editor, there's a really practical feature available while logged in (online) to the PLC: for an existing function block (e.g. TON or MC_MoveAbsolute), double-clicking on an unconnected input pin directly opens a value entry window right in the editor — with no need to assign any variable — and you can type a value directly. Likewise, if the input pin is of an ENUM or STRUCT type, it lets you pick a value of that type straight from a dropdown list. It also doesn't require assigning a variable or adding it to a watch list, etc. Unfortunately, in the CFC editor you can't write values directly to those unconnected input pins the way you can in Ladder — CFC only supports monitoring/display there. I wish this existing Ladder editor feature were also available in CFC — it would make the CFC editor far more usable. I think this would be a relatively small addition to the CFC editor, but it would make a real difference in daily commissioning and debugging work. It would be great to hear the development team's thoughts on whether this could be considered for a future release. Thanks in advance for reading!
Last updated: 2026-09-10

Post by bbm1995 on Camera RTSP Feed CODESYS Forge talk (Post)
Hi dgrard, I had the same issue for a long time, but on a WAGO webvisu. Now I'm glad that I can share my solution. I don't know if you are trying to use the webvisu or the target visu, but this works on webvisu: Get "go2rtc" and set it up according to the documentation. I'm running the Windows binary. Here's my example of the go2rtc.yaml config file (contains working example streams): api: listen: ":1984" # default ":1984", HTTP API port ("" - disabled) origin: "*" # default "", allow CORS requests (only * supported) static_dir: "www" # default "", folder for static files (custom web interface) tls_listen: ":443" # default "", enable HTTPS server tls_cert: "./SSL/fullchain.pem" tls_key: "./SSL/privatekey.pem" streams: # Streams with multiple links will fall back on the next link. ABUS TVIP48511: - rtsp://<username>:<password>@<hostname>:<port>/ch1/main - rtsp://<username>:<password>@<hostname>:<port>/ch1/sub # Diagnostic connections Kirchhoff Institute for Physics - Germany: http://pendelcam.kip.uni-heidelberg.de/mjpg/video.mjpg Blanton Bottling, Kentucky - USA: http://camera.buffalotrace.com/mjpg/video.mjpg Tokyo - Japan: http://61.211.241.239/nphMotionJpeg?Resolution=320x240&Quality=Standard Tampere Hacklab - Finland: http://tamperehacklab.tunk.org:38001/nphMotionJpeg?Resolution=640x480&Quality=Clarity Soltorget Pajala - Sweden: http://195.196.36.242/mjpg/video.mjpg Kaiskuru Skistadion - Norway: http://77.222.181.11:8080/mjpg/video.mjpg webrtc: listen: ":8555" #ice_servers: # - urls: [ "stun:localhost:3478" ] # username: "" # credential: "" Access the webinterface of go2rtc and get the link of your stream. Use the link as for your browser frame in the visualization. Depending on your device, you need to be able to access the file /etc/lighttpd/lighttpd.conf or /etc/lighttpd/webvisu.conf and change the contents similar to this one, otherwise you'll get CORS and CSP errors in the browser and you won't be able to view the stream on the webvisu: # Webvisu specific settings $SERVER["socket"] =~ port_webvisu_used_any { url.redirect += ( "^/webvisu/?$" => "/webvisu/webvisu.htm" ) $HTTP["url"] =~ "^/webvisu/?" { var.response_header_policy_webvisu = ( # CSP for WebVisu, allowing inline sources. "Content-Security-Policy" => "default-src 'self' 'unsafe-inline'; media-src *; frame-src *", # CORS for WebVisu, allowing any origin to access. "Access-Control-Allow-Origin" => "*", # Tell older browsers that this page can only be displayed if all ancestor # frames are same origin to the page itself. "X-Frame-Options" => "SAMEORIGIN" ) # Response header policy for WebVisu setenv.set-response-header = var.response_header_policy_webvisu setenv.set-response-header += var.response_header_policy_common }
Last updated: 2023-11-14

Post by gustavocsw on MQTT memory leak problem CODESYS Forge talk (Post)
Hello everyone, I'm using the IoT Library to implement the MQTT communication with my local broker server in order to publish and subscribe at specifics topics to share and consume information about my application. But, it seems that are occurring some memory leak problem in a "high" frequency (more than 10 Hz) subscribe process. I follow the same method as in IoT Lib exemples, and at first looks perfect but my PLC was rebooting frequently and when I check its memory usage that was increasing as fast as the subscribe massage was sent. I'm using a WEG PLC410 and a WEG PLC500, and this error occurred in both of them (including in CODESYS Control Win x64). The application sends to the system a message JSON with the float payload Ex. {"data" : 0.8500}, but this happens with a INT, or BOL as well. I use the follow code in my application to find the value: //FindFirstValueByKey VARs PROGRAM JSON_VELO VAR //------Setting the JSON Subscriber to Set the Relay Value jsonDataVelo : JSON.JSONData; jsonByteArrayReaderVelo : JSON.JSONByteArrayReader; xST1okVelo : BOOL; FindFirstValueByKeyVelo : JSON.FindFirstValueByKey; jsonElementVelo : JSON.JSONElement; xDoneReaderVelo : BOOL; xDoneFindVelo : BOOL; //STRING and WSTRING for Subscribe the massage sPayloadJsonVelo : STRING := 'opa'; psPayloadJsonVelo : POINTER TO BYTE := ADR(sPayloadJsonVelo); //wsPayloadJsonRelaySet : WSTRING := "opa"; wsPayloadJsonVelo : WSTRING := STRING_TO_WSTRING('opa'); pwsPayloadJsonVelo : POINTER TO WORD := ADR(wsPayloadJsonVelo); lrVelo : LREAL; xKeepAliveVelo : BOOL; xSetVelo : BOOL; RSSet : RS; LIMPAR : STRING; //Find the msg end sFindVelo : STRING := '}'; psFindVelo : POINTER TO STRING := ADR(sFindVelo); iLenVelo : INT; iSizeVelo : INT := 12; udiContMsg : UDINT; END_VAR // FindFirstValueByKey CODE // Relay Set configuration xSetVelo := MQTT_SUBSCRIBER.RSVelo.Q1; IF xSetVelo THEN xKeepAliveVelo := TRUE; END_IF IF xKeepAliveVelo THEN udiContMsg := udiContMsg + 1; iLenVelo := TO_INT(StrLenA(psPayloadJsonVelo)); iSizeVelo := iLenVelo - TO_INT(MQTT_SUBSCRIBER.udiPayloadSizeVelo); StrDeleteA(psPayloadJsonVelo,iSizeVelo,iLenVelo); wsPayloadJsonVelo := STRING_TO_WSTRING(sPayloadJsonVelo); pwsPayloadJsonVelo := ADR(wsPayloadJsonVelo); //MQTT.ConvertUTF8toUTF16(sourceStart:= ADR(sPayloadJsonVelo), targetStart:= ADR(wsPayloadJsonVelo), dwTargetBufferSize:= TAM, bStrictConversion:= 1); //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := TRUE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := xDoneReaderVelo, wsKey := "data", diStartIndex:= 0, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); IF xDoneFindVelo THEN lrVelo := jsonElementVelo.value.lrValue; //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := FALSE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := FALSE, wsKey := "data", diStartIndex:= 1, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); xKeepAliveVelo := FALSE; GVL.xSetVeloRead := TRUE; END_IF END_IF And this to subscribe at the topic: //SUBSCRIBE VAR: //----------------- Subscribe Velocity ----------------------- MQTTSubscribeVelo : MQTT.MQTTSubscribe;//Variable MQTTSubscriber block -X - function-X wsTopicSubscribeVelo : WSTRING(1024) := "CORE/odometry/GET/data/simp"; // Topic to publish a message sSubscribeMassageVelo : STRING; udiPayloadSizeVelo : UDINT; xSDoneVelo : BOOL; xSErrorVelo : BOOL; xReceiveVelo : BOOL; eSTypeVelo : MQTT.MQTT_ERROR; eSMQTTErrorVelo : MQTT.MQTT_ERROR; RSVelo : RS; udiCont : UDINT; //SUBSCRIBE CODE: MQTTSubscribeVelo( xEnable:= MQTT_CLIENT.xConnection_Broker AND NOT xSErrorVelo AND NOT JSON_VELO.xKeepAliveVelo, pbPayload:= JSON_VELO.psPayloadJsonVelo, udiMaxPayloadSize:= SIZEOF(JSON_VELO.sPayloadJsonVelo), udiPayloadSize => udiPayloadSizeVelo, mqttClient:= MQTT_CLIENT.ClientMQTT, wsTopicFilter:=wsTopicSubscribeVelo, xDone => xSDoneVelo, xError=> xSErrorVelo, xReceived => xReceiveVelo, eMQTTError=> eSMQTTErrorVelo ); RSVelo(SET := xReceiveVelo, RESET1 := JSON_VELO.xKeepAliveVelo);
Last updated: 2024-09-09

Post by imdatatas on MC_CamIn did not work properly with SMC_FreeEncoder on SoftMotion 4.17.0.0 CODESYS Forge talk (Post)
Hello, I am facing a problem with the new Softmotion 4.17.0.0 version. Has anyone encountered a similar problem, what is the solution? I would be happy if you could share it. Problem description: -- "SMC_FreeEncoder" encoder axis is the master, -- The motor of the servo driver on the EtherCAT bus is the slave axis. -- When the MC_CamIn block executed, the InSync output is activated. However, although the master encoder axis position value changes, there is no movement in the slave servo axis! Test steps: 1-) EtherCAT servo axis installed, configured and motion test was performed with MC_Jog. No problem. 2-) Softmotion general axis pool > SMC_FreeEncoder was added and pulse amount configuration was performed. No problem. 3-) Incremental encoder actual count value was transferred to the "SMC_FreeEncoder.diEncoderPosition" variable as DINT under the ethercat task in every cycle and the encoder axis position value was observed. No problem. 4-) A simple CAM table with a 1:1 ratio was created under the project tree. (For example: Simply, when the encoder rotates 1 turn, the motor will rotate 1 turn.) 5-) The SMC_FreeEncoder axis enabled with MC_Power and brought to the StandStill state. 6-) The MC_CamTableSelect block was run with default input values ​​(all absolute) and only the Cam table name was specified. The Done output was seen successfully. No problem. 7-) The MC_CamIn block was activated with default input values ​​(absolute) and only the master encoder axis name, slave servo axis name, CamTableID input pins was specified and then "Execute" input set to TRUE. 8-) The InSync output information of the MC_CamIn block observed as TRUE. However, although the encoder axis value changed, the position value of the slave axis did not change at all, it did not move. It always remained at 0.0mm. 9-) When I repeated the same steps above, only changing the master axis to SM_Drive_Virtual instead of FreeEncoder and gave movement to the virtual axis, this time the slave axis moved successfully. However, when the same steps and operations are performed with the same IDE just downgrade SoftMotion version from 4.17.0.0 to 4.10.0.0, everything works normally and without problems as expected in MC_CamIn block with FreeEncoder master. (By the way, The used IDE version is Codesys V3.5 SP20patch3.) Best Regards Imdat
Last updated: 2024-11-11

Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
In reality, other vendors are already moving towards integration with VS Code. B&R, for example, is likely the only one that could truly challenge Codesys in the market: they’ve overhauled their once-archaic environment (previously lacking ST OOP) and are now catching up significantly with Automation Studio Code, offering modern programming capabilities and native support for tools like Git and GitHub Copilot. The other big names in the market, frankly, are still light years behind. For smaller projects, typically handled by “wire strippers” (with all due respect!), a classic environment might be just fine. But once you’re dealing with thousands or even millions of lines of code—possibly organized in an OOP paradigm, spanning large teams, integrating third-party libraries, requiring version control, and performing comprehensive tests—a lightweight, responsive editor supercharged with AI-based features becomes essential. The real strength of something like VS Code lies in its vast ecosystem of extensions and integrations: from advanced Git support to automated build/test pipelines, and even AI-assisted autocompletion that already makes software development much more agile and productive. I understand that a PLC project involves more than just ST code (task setup, fieldbus configuration, libraries, etc.). However, there’s no technical reason not to at least provide ST files in a pure text format, making version control and collaboration far easier. B&R has clearly adopted this approach; I hope Codesys will accelerate its own efforts to offer a native, text-based integration and modern development tooling. Once you go beyond a certain level of complexity—dozens of configurations, OOP hierarchies, and distributed teams—you really do need “engineer-level” software tools, not just solutions targeting “wire strippers.” For large-scale automation projects, a more open and flexible approach is the only way to avoid chronic frustration. Let me emphasize that I truly love Codesys and consider the work done so far to be brilliant—I’d be sorry to see it overshadowed by others moving faster in this direction.
Last updated: 2025-02-18

Post by caspershes on Checking the device tree, not just the code: what else is worth a static check? CODESYS Forge talk (Post)
I spend most of my time reviewing other people's CODESYS projects before commissioning, and two kinds of defects keep showing up. Both compile clean. Both read fine. One is in the code. A pause timer whose own input gets cleared inside the branch the timer is supposed to gate: rampDelay(IN := run_2); IF NOT run_2 OR rampDelay.Q THEN run_1 := TRUE; run_2 := FALSE; // the timer's own input, cleared right here ELSE run_1 := FALSE; run_2 := FALSE; END_IF Next scan IN is FALSE, the timer resets, the condition is true again, and the second pump starts immediately. A 30-second ramp delay that actually lasts one task cycle. The setpoint is on the HMI, the operator turns it, and nothing changes. The other is not in the code at all. On one site the outdoor temperature read 0.0 °C in mild weather. The ST was correct, the variable was bound to the channel — but the channel's sensor type was left at "disabled", so nothing was ever digitised. Same class: a module with Disable_module = TRUE, or an analog output bound to a variable while its mode is off. Nothing in the project reports any of this, and the code review never looks there, because the configuration lives in the device tree and not in the POUs. That second class is what pushed me to parse the .export format rather than PLCopenXML alone — the export carries the device tree and the visualization, so "nothing ever writes this alarm variable" stops being a guess and becomes a fact you can check against the screen bindings. Three things about the format that cost me time, in case they save you some: the same device parameter can appear three times (template, internal copy, actual configuration) — the last occurrence is the one in effect; the enum value of a parameter is not in the parameter itself, it is one level down in BaseType/Value; a channel counts as used when a variable is bound to SensorValueN.SensorValue — InputStatus is a bad indicator, people deliberately bind it on spare inputs. So the question. What else would you check automatically, given both the code and the device tree? I am collecting rules from sites, not from style guides, and the configuration side feels largely unexplored. For what it is worth, the checker I use for this is free and runs offline (single exe, no install, nothing uploaded anywhere): https://github.com/caspershes/plc-lint — 43 rules at the moment, reads .export and PLCopenXML. Happy to add rules people here suggest.
Last updated: 2026-10-27

Post by jickisticki on Witch library? CODESYS Forge talk (Post)
Crafting my Fellowship Personal Statement was like weaving the threads of my aspirations into a tapestry of words. Each sentence became a brushstroke, painting a vivid portrait of my journey and ambitions. Beyond being just a document, it became a mirror reflecting the depth of my experiences. Like a conductor guiding an orchestra, my personal statement was composed to resonate with my unique voice. In the realm of specialized opportunities, this statement serves as a compass, guiding me toward the next chapter of my professional growth. With each word, I felt the guidance of mentors shaping my story into an eloquent narrative.
Last updated: 2023-08-17

Post by ellcap on Did a library update and now can't open project CODESYS Forge talk (Post)
EDIT: Title was a mistake. Should say now I can't compile / download project. Codesys V3.5SP19 Patch 2. Updated the libraries/packages using the Codesys Installer. I'm hit with this error ------ Build started: Application: ------- Typify code... [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0086: No definition found for interface 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0077: Unknown type: 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): Initialize [IecVarAccess]: C0032: Cannot convert type 'IECVARACCESS(iecvaraccess, 4.4.0.0 (system))' to type 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0231: Expression of type 'BOOL' expected in this place [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0077: Unknown type: 'ITFID_IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0046: Identifier 'ITFID_IIecVarAccess17' not defined Compile complete -- 6 errors, 101 warnings Build complete -- 6 errors, 101 warnings : No download possible
Last updated: 2023-09-25

Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
I'm getting closer to the error. The combination of STRUCT and ARRAY probably causes the strange behavior. As soon as the ARRAY is followed by a variable, the problem arises. Examples: X: ARRAY[1..2] OF INT; // okay Y: ARRAY[1..2] OF STRUCT; // problem Z: STRUCT; Z.ArrayOfInt[1]; // okay Z.ArrayOfStruct[1].Variable // problem // *update - array of array also causes the error A: ARRAY[1..2] OF ARRAY[1..4] OF BOOL; // problem I can't be the only one who has this problem. Or? Maybe there is a solution. Anyone? Or is it a bug after all?
Last updated: 2023-11-17

Post by dkugler on Management of a PLC network from a remote station CODESYS Forge talk (Post)
I would figure out, how to create a simple html webpage with 2 frames. One frame with buttons to select the plc. A second frame with hyperlink to the webvisu of the plc ("XXX.XXX.XXX.XXX:8080/webvisu.htm"). Selecting other PLC Button has to change the hyperlink in 2. frame. Costs only some time to figure out :-) Or setup a raspberry Pi with small visualization. Set up a button for each plc and add one browser element. Each button writes the URL of the depending plc to the URL setting of the browserelement. Costs 55€ for runtime licence and a Raspberry Pi.
Last updated: 2023-12-04

Post by peterned on Programatically restart Codesys OPC UA server? CODESYS Forge talk (Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19

Post by eguerra on Error in ScriptingEngine Docs - create_pou() CODESYS Forge talk (Post)
In the ScriptingEngine documentation there seems to be an error (or missing information) in the ScriptIecLanguageObjectContainer part ( https://content.helpme-codesys.com/en/ScriptingEngine/ScriptIecLanguageObjectContainer.html#ScriptIecLanguageObjectContainer.ScriptIecLanguageObjectContainer ). The description of the function create_pou() doesn't specify the correct arguments requested, it only says create_pou(type: SpecialPouType) and a script using the documentation definition of the function will raise an error. I tried passing the function arguments similar to the ones specified for the create_dut() function and it seems to work fine: create_pou(name, PouType) , name : str UPDATE: The offline help has the correct definition IExtendedObject<IScriptObject> create_pou( string name, PouType type = PouType.FunctionBlock, Nullable<Guid> language = null, string return_type = null, string base_type = null, string interfaces = null )
Last updated: 2024-08-05

Post by dkugler on Webvisu client connection monitoring CODESYS Forge talk (Post)
you can give this code snippet a try. It's extracted and simplyfied from my code: Install VisuElemBase lib if not installed yet. Execute in visu task: VAR pClientData : ARRAY [-1..100] OF POINTER TO VisuElemBase.VisuStructClientData; END_VAR VisuElemBase.g_ClientManager.BeginIteration(); pClientData := VisuElemBase.g_ClientManager.GetNextClient(); WHILE pClientData <> 0 DO pClientData[pClientData^.GlobalData.GlobalClientID] := pClientData; END_WHILE You have to make shure every no longer updated pointers in the array have to be deleted and no longer used by your code! Usage of this pointer access at your own risk :-) Works with SP16. From SP17 and newer there will be warnigs etc. using this solution as I remember. It will be great, if Codesys publishes a example or give a hint how to accesse this client values with the VisuUtil lib or other future-proof way!
Last updated: 2024-09-09

Post by timvh on Visuutils FbOpenDialog(Extended) not open Dialog from POUs CODESYS Forge talk (Post)
I had a similar situation recently where this didn't work, but read to the end to see the solution. The reason is that CODESYS only downloads visualisations (dialogs) if they are part of the project or linked to the project. In your case the dialog is not loaded onto the controller. But the solution is pretty simple: Double click on the Visualization Manager in your application. Select the Tab "Visualizations". Here you can see that your dialog is not "checked". Do this manually and load your project on the controller. Then your code should be able to open the dialog, because now it exists on the controller.
Last updated: 2024-09-28

Post by timvh on FB string and naming CODESYS Forge talk (Post)
I see, you want to initialize the FB. To be able to initialise it like you described, you need to add the FB_Init method to your FB. (right click on the FB, select add object --> method). Then press the arrow down, to select the FB_Init (overwrite default implementation). In the VAR_INPUT section of this method, add the variable --> Tag : STRING; Then in the code section of this method add: THIS^.Tag := Tag; // copy initial value to local variable in FB Search Google if you want to know more about FB_Init. PS, reflection + instance path, is also an option if you want to get the full name of the instance (path) of the Function Block. See: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_instance_path.html
Last updated: 2024-09-30

Post by struccc on HTML5 Controls - string(>80) values CODESYS Forge talk (Post)
Dear all, does anyone have experience with HTML5 controls recently? CODESYS 3.5.20.30 / Visualization 4.6.0.0 I'd like to create a simple lightweight text editor, with proper multiline handling, cut & paste, scrolling, etc. And it seems to work fine, just have problems with strings longer than 80 bytes.... Declaring a variable sText1 : STRING(8000) and referencing it in the HTML5 Controls corresponding value property works perfectly one way: the code receive the data as a string (See log1)... (Note TypeID 1000...) Also sending back the data (seems to work (See log2) except it doesn't change the value of the bound variable. Probably the issue is with using SendSimpleValue method... Naturally, I could do a workaround, but maybe there is a more standard way to implement this... Please let me know if you have any suggestions.
Last updated: 2024-10-23

Post by shafiq-dsc on Beckhoff EK series cannot detect but BK1120 detect CODESYS Forge talk (Post)
Dear Support, I have i950 wants to connect with Beckhoff EtherCAT coupler BK1120. There are 2 GSD files for BK1120. 1. BK1120 without MDP.(EtherCAT ESI Device Description (XML)) 2. BK1120 with MDP. (EtherCAT BKxxx (MDP) configuration files) When connecting the BK1120 with i950, scanned devices detects BK1120 without MDP from ESI No1 above. But the KL1408 & KL2408 not detect because they have ELxxxx IO type. When manually insert BK1120 with MDP, the KL1xx8 is able to add manually also but the error shows and Install Missing Descriptions appears. The questions; 1. Why the error occurs? 2. Can the i950 connect with KLxxxx IO type or not? Regards, Shafiq
Last updated: 2024-10-25

Post by struccc on Request a dark mode for CODESYS CODESYS Forge talk (Post)
😁 Yes, exactly... I have a clue about the why not... But really, it was many years, releases ago... Agree, this is not a functionality customers would pay for, but it's one rendering the product cool and contemporary. Like many other "simple" features like: Opening multiple projects within the same IDE Not just attaching, but editing diverse files inside the IDE (like XML, TXT, SVG?) Use 3rd, CODESYS independent plugins, editors inside the IDE... Isn't it possible to integrate CODESYS Engineering under VS? Or just use the core functionality from VS? Or the LINUX guys have a better idea?
Last updated: 2024-11-13

Post by simone on Collapse all CODESYS Forge talk (Post)
Hi, I'm wondering if it exist a button or a keyboard shortcut (much much better) for "collapse all" the open folder on a codesys project. It would really be nice to have. Also: Are there some options or configuration for set a default zoom for the different editor (or even one global), for example I would like to have 100% on ST, LD editor and have 80% on Visualization Editor; and also have a button to set all the zooms to default, now it seems that every file mantain the one previously set. I'm working with the 3.5.20.10 right now Thanks!
Last updated: 2024-11-21

Post by kevinrn on Github Actions CI/CD tasks - development topic CODESYS Forge talk (Post)
Hi @steven-schalm, Thank you for your inquiry, and I apologize for the delayed response! We use GitHub Actions cloud runners for this purpose, as it eliminates the need to maintain our own build runners. You can get started by creating a free GitHub account, which includes complimentary minutes for running actions on Windows runners. You can find an example implementation in our repository: https://github.com/powerIO-GmbH/action-codesys-setup I'm currently working on making additional features public, including: Git checkout functionality, Code signing, Custom script execution However, these additions require some preparation before release. Feel free to contribute to the project! BTW: You can also execute this locally, even the yml files with nektos/act on your windows dev machine.
Last updated: 2024-11-27

<< < 1 .. 134 135 136 137 138 .. 142 > >> (Page 136 of 142)