Post by soped on How to generate EtherCat xml from command line
CODESYS Forge
talk
(Post)
Hi Under tools->customize I have added the command "Generate ethercat xml" to my project so that I can export the configuration as an xml file. I can't find a way how to run that command from CLI, is that even possible and if a script is needed I would appreciate an example ?
Last updated: 2024-06-27
Post by soped on How to generate EtherCat xml from command line
CODESYS Forge
talk
(Post)
Hi I'm using codesys 3.5 SP4 Under tools->customize I have added the command "Generate ethercat xml" to my project so that I can export the configuration as an xml file. I can't find a way how to run that command from CLI, is that even possible and if a script is needed I would appreciate an example ?
Last updated: 2024-06-27
Post by rschwager on GVL to SHMem
CODESYS Forge
talk
(Post)
Hallo! Have some any idea to transfer whole GVL to Shared Memory? I also shared REATIN memory to shraed meory for making a Retain Backup System without USP in Linux on a FRAM. For an other Application we want to shared the whole GVL off obne part (e.g. GVL_Test). How cvan I get easy the Size and the Address for meory copy?
Last updated: 2024-07-09
Post by elerensx on Uninstall Codesys2.3 got RUNDLL There was a Problem Starting error
CODESYS Forge
talk
(Post)
Try to repair Codesys2.3 and need to uninstall and reinstall it. Got this RUNDLL message when uninstall Codesys 2.3: There was a problem starting, the specificed module could not be found. Please refer to attached file. Followed suggestions from Microsoft website and didn't work out. I am using Codesys2.3.9.16. Any help is appreciated.
Last updated: 2024-07-15
Post by nltheves on Raspberry PI4 Serial Port
CODESYS Forge
talk
(Post)
Hi Ricardo. I was having the same problem with Codesys and a Raspberry Pi 2W while using the GPIO uart. Your post helped me a lot. Thanks! But could not understand why MODBUS parity bit makes Codesys MODBUS COM driver stopping to work after first request transmission. Did you see this @eschwellinger ? Regards, Nelson
Last updated: 2024-07-18
Post by timvh on Array to String
CODESYS Forge
talk
(Post)
The string_Util_Intern is not the library I referred to. With a CONCAT function (also with the string util library) a search is done for the NULL character. If you concatenate 20000 characters to one string, then the longer the string, the longer it takes to find this NULL character.
Last updated: 2024-07-24
Post by maldus512 on How to adapt Codesys Control SL to custom board
CODESYS Forge
talk
(Post)
Hello everyone, I have been given the task to develop I/O drivers for a custom made, Linux based board to allow for Codesys applications to run and control the hardware. I have successfully installed Codesys Control SL for ARM/Linux and tested it with a simple demo application. Now I should start interfacing the runtime to the actual hardware; I should be able to interact with 2 RS485 serial ports, a few GPIOs and an I2C port, all of which already have the corresponding /dev/ interface in the Linux system. I am having trouble understanding how it should be approached. I have found sporadic references that fail to lead to a really comprehensive documentation. For example: The store page (https://store.codesys.com/en/codesys-control-for-linux-arm-sl-1.html#options) mentions a "runtime package" that should allow "Integration of existing C code" and "Usage of local I/Os", which seems exactly what I need to interact with custom peripherals. I have found no further reference to Codesys-C interpop. The Codesys Help page for the runtime package has a page on the "Development of Drivers" (https://content.helpme-codesys.com/en/CODESYS%20Control/rtsllinuxrbpdriverdevelopment.html) that suggests to either "Implement a function block" or "Implement I/O drivers". Those in turn lead to this page (https://forge.codesys.com/drv/io-drivers/doc/Generic/) which describes briefly an XML schema to describe new devices; unfortunately, it doesn't mention what to do with such a description (i.e. how does the runtime know about it) or how it is in any way connected to the actual hardware. Could anyone give me some pointers? I should also mention I have no prior experience with Codesys, so maybe I'm missing an obvious answer.
Last updated: 2024-08-09
Post by daqe102 on HTTP CLIENT (MAX SIZE)
CODESYS Forge
talk
(Post)
Hi everybody I'm Paul and I need your knowledge, I am trying to send a huge Json (about 60,000 characters) through http client FB from codesys, however I saw that Maximum size of the http request in btyes are 16000, So, is there any way to resolve this situation? is it posible or there's a another opction to do it?
Last updated: 2024-08-21
Post by thedertom on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
Hi I try to get korean texts out of a textlist. For that I want to use DynamicTextGetTextW, but I am a little confused how it is supposed to work. The function returns POINTER TO STRING, but how do I get WSTRING? I succesfully used DynamicTextGetText with classical Strings. Thanks in advance!
Last updated: 2024-09-02
Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager
CODESYS Forge
talk
(Post)
Unfortunately , Data Source Manager from Codesys has any problem with OPC UA Server delivered with ifix SCADA. Someone can help me add manually any tag from UaExpert to codesys ? How should be was a structure for an example of one tag ? I try like in attachement, but question is , if it a good idea ?
Last updated: 2024-09-08
Post by nano on ERROR: CodeMAccess2: Used CmRuntime 2.61.2705.500 is too old
CODESYS Forge
talk
(Post)
the codemeter deb files are part of the runtime-sl-installatonfiles. so u can download the whole raspberry pi package from store-page, unzip it with a progam like 7zip, there you'll find a folder called dependencys i thing. here should the deb files placed
Last updated: 2024-09-18
Post by bjarne-pagaard on Unable to add alarm configuration object to project
CODESYS Forge
talk
(Post)
I believe it should be available. It may be the case, that your device does not support the alarm configuration. Some smaller PLCs sometimes do not support it. You can try changing to a different device, like a Codesys Control Win, in your project, and see if then allows you to add the alarm configuration.
Last updated: 2024-09-27
Post by timvh on Configuring a 2's compliment
CODESYS Forge
talk
(Post)
You could create a DUT of the Type Union and add an array of 2 bytes + an Int. Then write the byte values in the array of the Union and read the Int. Or VAR iInt : INT; byHigh : BYTE := 2#1111_1111; byLow : BYTE := 2#1111_1111; END_VAR iInt := TO_INT(byHigh*16#100 + byLow);
Last updated: 2024-09-28
Post by timvh on FB string and naming
CODESYS Forge
talk
(Post)
Really not clear what you are trying to do, but isn't a Struct enough? So add an object of the type DUT to the Application. Then create a structure TYPE ST_Sensor : STRUCT sName : STRING; uiNumber : UINT; END_STRUCT END_TYPE Then in you application add an instance of this Structure stSensor1 : ST_Sensor := (sName := 'my sensor', uiNumber := 1); or use it like this stSensor1.sName := 'my sensor';
Last updated: 2024-09-28
Post by tdaf on Codesys KNX Demo limitations
CODESYS Forge
talk
(Post)
Hello to all. I am testing the Codesys KNX package using a raspberry pi to determine if it fits my needs. Does anyone know the limitations of the package when you use it without a license? I searched for it myself but couldn't find any information on the matter. Thank you all for your help.
Last updated: 2024-10-05
Post by davidmic on What is this ST syntax?
CODESYS Forge
talk
(Post)
I found some structured text code which contained this statement: bHidden:= TRUE(*NOT _somevariable*) I haven't seen TRUE() used like a function before, and I also haven't seen the enclosing asterisks * * before. What do they do? (sorry if this is a duplicate question, I don't know what words to use to search for this syntax)
Last updated: 2024-10-11
Post by davidbo on Modbus: Is there a way to get the channel index from the channel name?
CODESYS Forge
talk
(Post)
When I use the FUNCTION_BLOCK ModbusChannel I have to sepcify the integer iChannelIndex It can easily go wrong if one has many channels. It would be better if one could use the name. Is that possible? Attached a snippet of the channel name and the channel index to the left.
Last updated: 2024-10-21
Post by dekelec on TrueType font problem
CODESYS Forge
talk
(Post)
Initially I had the same problem in CoDeSys when selecting a newly installed TTF font, while CoDeSys was running. I solved it by closing Codesys and running it again to restart the initialization process. After that, using the new font did not pop up errors. I also had cases with files that had a ttf extension, but were actually not TrueType.
Last updated: 2024-10-22
Post by pixsys on loading delay with the option "check client animations and overlay of native elements"
CODESYS Forge
talk
(Post)
Hi, the option "Support client animations and overlay of native elements" needs a very powerful graphics accelerator in the system. I'm using the Pixsys srl "TC series" HMI with the code "P3" (so a 4+4 cores CPU) that runs very well also with this option active.
Last updated: 2024-11-06
Post by timvh on Converting each character to a string into ASCII
CODESYS Forge
talk
(Post)
Nice puzzle for a Saturday afternoon :-). Here my suggestion: VAR sInput : STRING := 'R123'; byChar : BYTE; sOutput : STRING; i: INT; END_VAR sOutput := ''; IF LEN(sInput) = 0 THEN RETURN; END_IF FOR i := 0 TO LEN(sInput) - 1 DO byChar := sInput[i]; sOutput := Concat(sOutput, TO_STRING(byChar)); END_FOR
Last updated: 2024-11-09
Post by bertcom on Converting each character to a string into ASCII
CODESYS Forge
talk
(Post)
@TimvH, Thank you, i think this way i can seperate the complete string to characters. Next part of the topic is converting the characters to an ASCII code. Is there an standerd function in Codesys for this? I alredy searched a few hours for it on the internet. no succes.
Last updated: 2024-11-11
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
I don't have a multiplexer so it very weird that it connects with that multiplexer. If i do a I2C scan on the PI terminal, i only get the device addresses 0x48 and 0x51. One for the ADC and one for RTC. I will try again with your libraries
Last updated: 2024-11-12
Post by nz-dave on Ethernet/IP Scanner Exception
CODESYS Forge
talk
(Post)
HI I have had a project running for a few weeks and twice it has shut the program down due to this exception. exception[ProcessorLoadWatchdog] occurred in: App=[all], Task[all] I have to reboot (power cycle) the system to clear the exception. or remotely restart the application. Any ideas? Cheers
Last updated: 2024-11-16
Post by hyys12 on Energie price
CODESYS Forge
talk
(Post)
I am definetly not an expert in this field, but it does seem like you need a propper API key in the URL. Right now you are using the token 'ANWB' in your URL, which the website returns an error, since this is not valid. Somehow you first need a propper API key. I hope that makes sense.
Last updated: 2024-12-06
Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3
CODESYS Forge
talk
(Post)
The problem is that newer PeakCAN cards are with CAN FD support and SJA1000 compatibility isnt mentioned anymore on website. anyway, is it possibile to add a seperate entry for it in: [CmpSJACanDrv] ? Edwin, can you give us a hint how to format it?
Last updated: 2024-12-16
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.