Post by nz-dave on FAILURE TO OPEN PROJECT ON ANOTHER COMPUTER CODESYS Forge talk (Post)
Thanks Tim that worked well. saved the config from work pc, imported to home laptop. it downloaded packages and the program opened with no errors and started straight up! legend!
Last updated: 2025-01-23

Post by fless on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
to get the address just use ADR( ) variables defined in a VAR_IN_OUT block are references pointing to the passed variables. VAR_IN_OUT MyVar: bool; END_VAR VAR adrMyVar: __XWORD; END_VAR adrMyVar := ADR(MyVar);
Last updated: 2025-01-26

Post by bertcom on STRING conversions to DWORD CODESYS Forge talk (Post)
Good afternoon. I want to communicate with a Domino Industrial Printer using its Codenet protocol. The printer wants a series of Hexadecimal characters with no spaces or '00' characters. Because of that i chose the option to make the prefix and subfix for my code in a string. I have variable data in another string. With a complete program of a lot of CONCAT functions i eventually get the format of code that the printer accepts ( tested it with the hercules tool). Hercules String : 1B4F513030311B7532626C61636B04 The problem is : Codesys adds automatically 'code' to the code to show it is a string. Codesys string : '1B4F513030311B7532626C61636B04' The printer does not understand this. My idea is to convert the string datatype to an LWORD. I have no idea how to do this. I random types in STRING_TO_DWORD, as return i get 0. That didn't worked. Also on internet the explenations around string converting in codesys are very limited. If there in anyone who can explain me how to do it, i would appreciate it a lot ! Thank you!
Last updated: 2025-01-29

Post by timvh on VisuElems.cmpDynamictext.DynamicTextGetTextW returns pointer to empty string CODESYS Forge talk (Post)
Try this: VAR sTextList : STRING; END_VAR sTextList := 'NameOfTheTextList'; // call to the function with the address of the string variable which contains the name of the textlist : ... ADR(sTextList), ....
Last updated: 2025-02-07

Post by gediminas on Datasource OPC UA client system failure CODESYS Forge talk (Post)
I haven't actually found an answer yet. It happens quite rarely, so testing and diagnostics are complicated. I've updated the software with every SP and add-on updates released, but it's probably a Kernel driver issue.
Last updated: 2025-02-09

Post by fabiodasilveira on PLC Shell commands via ST Code CODESYS Forge talk (Post)
Thank you, Bingo. Your idea of adding the change to the start up process works. However, I am still intrigued with the fact that SysSockSetIPAddress(strEthernetPort:= '0', strIPAddress:= '192.168.2.12') is different from PLC Shell (setipaddr 0 192.168.2.12).:-(
Last updated: 2025-03-04

Post by ph0010421 on Axis EtherCAT address CODESYS Forge talk (Post)
Hello SDO will write to the drive, not the axis, so you need to pass in the ethercat slave: VAR_IN_OUT Axis: IoDrvEthercatLib.ETCSlave; END_VAR Then you can get the address with: Axis.PhysSlaveAddr (as UINT)
Last updated: 2025-03-07

Post by konstantinoskr on AXIS Rollover CODESYS Forge talk (Post)
Hello, I have an application with 2 axis. The master axis will be configured as Modulo. During motion i want to be able to change the rollover position if required. How is it possible to do this?
Last updated: 2025-03-11

Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue CODESYS Forge talk (Post)
Thanks for the replay. My RPI is a 3B+ model with bullseye OS. I don't understand why 0.0.0.4 is working ok and future versions not.
Last updated: 2025-03-22

Post by buczekj on Problem with MCP2515 and library CANbus CODESYS Forge talk (Post)
Hello, I encountered this same error. I was able to resolve it by allocating more messages when I open the network driver (ctMessages:= 100). By default it is set to 25.
Last updated: 2025-03-27

Post by andreag0 on Fieldbus has lost synchronicity CODESYS Forge talk (Post)
Hello, I have similar issues and if I remove AC_Persist than is fine. I can't figure out yet why the AC_Persist is caused such issue. I have i5 with 6 core and Debian 10 RT Kernel.
Last updated: 2025-04-04

Post by mariacugnier on Modbus TCP/IP having problems with global variables CODESYS Forge talk (Post)
Are these variables already declared in the IO list? It looks like it's trying to create new variables instead of mapping them to the existing ones.
Last updated: 2025-05-22

Post by fleaplc on Symbol Configuration to be Build every time! CODESYS Forge talk (Post)
I'm using Symbol configuration to share PLC variables with SCADA via 3S protocol (Symbol File). All is working fine except every time I open the project.. then I need to rebuild Symbol Configuration! Why?
Last updated: 2025-05-23

Post by andrax on Variable Length Array - Cannot mix variable and fixed length dimensions? CODESYS Forge talk (Post)
Arrays with variable lengths are a bad idea. This makes your system unstable and can lead to crashes. Declare your array large enough to reserve enough memory
Last updated: 2025-05-24

Post by tk096 on How to get the motor scaling value from code CODESYS Forge talk (Post)
Hi, unfortunately, in Softmotion you have only access to the combined fraction - the scaling factor from user units to motor increments. It can be accessed using MC_ReadParameter with parameter number 1054. increments = user_unit_position * fScaleFactor
Last updated: 2025-06-13

Post by nxbp on Cam Editor And Cam Problem CODESYS Forge talk (Post)
I Created cam with 361 cam points ( 0,1,2.....360 ). The values in the Cam_A array do not match the Cam points entered in the Cam editor.
Last updated: 2025-06-22

Post by rckalex on Adjusting Ethernet Settings from Visualization CODESYS Forge talk (Post)
Could someone please share reference documentation for interacting with a device's IP settings from a visualization/webvisu? Is what is outlined here still valid? https://forge.codesys.com/forge/talk/Engineering/thread/ad11c199a2/
Last updated: 2025-06-26

Post by nano on Creating, using an external Function. CODESYS Forge talk (Post)
hi Andrej, thx for your feedback. i'm very familiar with creating such components. if you need some further help, just clock on me. greetings Nano
Last updated: 2025-07-23

Post by pouyavakili on Execute Codesys Tests with python CODESYS Forge talk (Post)
Thank you for your input! What I'm ultimately trying to achieve is automated test execution as part of a CI/CD pipeline (e.g. in GitLab or Azure DevOps). For this, I need to: Open a CODESYS project via script Build the project Run the Test Manager tests from a .TestRepository.xml Collect test results (e.g., pass/fail + a report) Exit with a proper return code (for pipeline success/failure) To integrate this into automation, I’m using the CODESYS scripting engine via Python (headless), but the issue is that the get_testmanager() function isn't available on the project object β€” even though Test Manager is installed, licensed, and works interactively in the IDE. Are you suggesting that I should: Use the Test Manager GUI to script the logic with its internal scripting language? Or is there a way to launch the Test Manager in headless/scripted mode, while still being able to control things via Python? If there's a supported way to automate tests with the Test Manager using scripting, especially from pipelines or headless environments, I’d really appreciate any pointers or example workflows. Thanks again!
Last updated: 2025-07-24

Post by ph0010421 on Dynamically enabling/disabling Modbus slave devices in runtime (performance issue with timeouts) CODESYS Forge talk (Post)
Hello If you uncheck 'Auto restart Communication', it will try once and never again. You can manually reset the slave if needed : Slave.xReset (or something similar) Or I have a ModbusRTU library if you want to try it.
Last updated: 2025-08-12

Post by davidbo on SQLite with AC_Datalog and Raspberry Pi CODESYS Forge talk (Post)
I am using V3.5 SP20 and version for AC_Datalog is 4.3.0.0 But in the log I get "DataLogStorage_SQLite: Not able to open table." Why and how to fix that?
Last updated: 2025-08-14

Post by davidbo on SQLite with AC_Datalog and Raspberry Pi CODESYS Forge talk (Post)
Does anybody have a schema.sql so I can create the table myselves? Does anybody know to generate more logging information so I can see the tables names? Do we have a level option or something like that?
Last updated: 2025-08-15

Post by imdatatas on The default ramp type selection in SoftMotion V4.18.0.0 is Quadratic CODESYS Forge talk (Post)
Unfortunately, The same behaviour still exist with SoftMotion V4.19.0.0 too. (default ramp type is quadratic instead trapezoid for new created axis object) For your information.
Last updated: 2025-09-04

Post by gseidel on High-resolution drive with SoftMotion CODESYS Forge talk (Post)
Hi kporter, what value do you use for the modulo period? Can you please provide the complete axis configuration, including all scaling values? Thanks, Georg