Post by kiranbsiddaiah on CodeSys OPC UA client Unable to Connect To OPC UA sever through Username and password CODESYS Forge talk (Post)
Hi, I'm using codesys v3.5 sp21 software. I have downloaded the sample opc ua client project from https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_uacapi_example.html and i tested connecting to "prosys opc ua simulation server". Through Anonymous connection it is connecting to server and can read data. Later tried to connect using username and password. First got a SECURITY_CHECKS_FAILED error, trusted the client certificate in the server and this issue resolved. Next got an INVALID_CERTIFICATE error, trusted the server certificate in the client and this issue resolved. After these two error it is not establishing the connection and not giving any error messages. UAAsyncProp: UA.AsyncProperty := (tnTaskName:='UAClientTask', usiTaskPrio:=20, udiTaskInterval:=10000); UAPolicy: UA.SecurityPolicy := (sPolicy:=UA.OpcUa_SecurityPolicy.OpcUa_SecurityPolicy_Aes128Sha256RsaOaep, eSecurity:=UA.SECURITY_MODE.SIGN_AND_ENCRYPT); //UAPolicy: UA.SecurityPolicy := (sPolicy:=UA.OpcUa_SecurityPolicy.OpcUa_SecurityPolicy_None, eSecurity:=UA.SECURITY_MODE.NONE); UAAuth: UA.UserNameAuth := (sUserName:=UAVars.sUser, sPassword:=UAVars.sPass); UAClient: UA.Client := ( itfAsyncProperty:= UAAsyncProp, //sClientName:= 'MyOPC UA client name', //default: ‘CODESYS OPC UA Client’ sURL:= UAVars.sURL, sSession:= UAVars.sSession, itfPolicy:= UAPolicy, itfAuth:=UAAuth, udiTimeout:= 100000 //,itfNamespaceArray:= UAVars.itfNamespaceArray //optional use ); ----------------------------------------------------------------------------------------------------------------------- Please let me know if any additional information required. Thank you...
Last updated: 2026-05-07

Post by malte on OPC UA multiple Endpoints CODESYS Forge talk (Post)
My CODESYS OPC UA server provides endpoints using both the hostname and the IP address. Connecting via the IP address works fine, but connecting via the hostname does not. The endpoint list shows both opc.tcp://<hostname>:4840 and opc.tcp://<ip>:4840. When using the hostname, the OPC UA client (UA Expert) fails to connect. Using the IP address connects without issues. Main goal is to conect via Python but opcua-asyncio seems to prefer the hostname. How can I configure CODESYS or my system so that the OPC UA connection via hostname also works properly or disable it completly? Running Codesys for PFC200 sl 4.18.0.0
Last updated: 2025-10-28

Post by ulvis on IDE chrashes when importing OPC UA ECM model CODESYS Forge talk (Post)
I can import some OPC UA information models, allright. Like the UA (core), Scheduler and PNEM models, etc. However, when I try to import the ECM model (Energy Consumption Managment), the Codesys IDE goes down after a while. Any clues?
Last updated: 2025-08-13

Is OPC communication possible with server certificate but no client certificate CODESYS Forge talk (Thread)
Is OPC communication possible with server certificate but no client certificate
Last updated: 2023-10-06

Data Sources Manager causing exception due to float or double type in OPC server CODESYS Forge talk (Thread)
Data Sources Manager causing exception due to float or double type in OPC server
Last updated: 2024-07-01

Post by romrot on Trying to connect Codesys OPC server to Ignition CODESYS Forge talk (Post)
Trying to connect Codesys OPC server to Ignition, but I get this fault "java.lang.Exception: no anonymous token policy found"
Last updated: 2025-01-21

How to get the Raspberry Pi PLC to control a Siemens PLC with OPC server CODESYS Forge talk (Thread)
How to get the Raspberry Pi PLC to control a Siemens PLC with OPC server
Last updated: 2018-11-09

CoDeSys OPC DA SL won't install on Windows Server 2012 R2 CODESYS Forge talk (Thread)
CoDeSys OPC DA SL won't install on Windows Server 2012 R2
Last updated: 2020-11-03

Plc's gets disconnected from OPC server when any one plc shutsdown CODESYS Forge talk (Thread)
Plc's gets disconnected from OPC server when any one plc shutsdown
Last updated: 2018-02-22

Codesys OPC DA server requires more then 2 GB of ram CODESYS Forge talk (Thread)
Codesys OPC DA server requires more then 2 GB of ram
Last updated: 2024-01-25

Post by mainak on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
Hello all, I am using the OPC UA server with my custom information model. I have used the communication manager to add my information model under my application and created instances from OPC UA types. I see that the created instances in the OPC UA server has some opaque nodeid (attached screenshot) and I want to change that. Therefore I have the following questions: 1. Is there a way to configure the NodeIds of instances in the OPC UA server? I tried to edit it using the UaExpert client but got error "BadNotWriteable". is it possible to configure it somewhere so that the nodeids can be changed using an external client? 2. Is there a way to define the rule for creating instance nodeids within the codesys IDE? 3. Is it possible to create the instances before e.g. using a modelling tool like UaModeler and import them as part of the information model and use them later? Using the communication manager, I can only create instances from types. I couldn't find a way to map my existing instances to plc tags from my application. It would be nice if someone could help me with these issues. Thanks in advance. :)
Last updated: 2024-10-19

Post by tjacks on Opc UA Data Source Client Browse Error in Codesys HMI CODESYS Forge talk (Post)
Codesys V3.5 SP21 Patch 3 Codesys HMI 3.5.21.30 I'm trying to connect to an OPC UA server on a Kuka robot controller using Codesys HMI's data source manager. I get through the login phase and the client browses most of the data structure on the server but errors out toward the end with a generic: Error while browsing the client, Failed with service result: BadUnexpectedError. If I complete the data source setup and try to update variables, I get the attached stack trace for the error. I've tried several different endpoint and security options. Most get me through the login but all error out while browsing. UA Expert happily connects and browses with the same configuration. I've connected this same version of Codesys to TwinCAT OPC UA servers and Siemens PLC OPC UA servers. Any ideas on what may be causing the generic BadUnexpectedError during OPC UA server browse?
Last updated: 2025-11-17

Post by dsa28 on OPC UA subscriber not operational CODESYS Forge talk (Post)
Hello All, Hopefully I can get some help configuring an OPC UA subscriber in a CODESYS runtime in a Raspberry Pi 5 that tries to retrieve data from an OPC UA publisher (in this case running in a TwinCAT system). I tried to follow the steps described in the page to implement the OPC UA subscriber: https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_opcua_pubsub.html Seems that the example provided was created with version 3.5.16.0. Now with version 3.5.20.20 is not possible to open the complete project neither convert it. Anyway, after configuring all IPs and ports used in the OPC UA connection function block but the connection state always shows DISABLED. Can someone help me to do the proper configuration of the OPC UA subscriber? Many thanks in advance.
Last updated: 2024-10-22

Post by dat422 on OPC UA Codesys 3.5 Symbolkonfiguration VS Kommunikationsverwalter und Python/UA-Expert CODESYS Forge talk (Post)
Hallo zusammen, kann mich leider mattplc nur anschließen
Last updated: 2025-04-03

Post by dat422 on OPC UA Codesys 3.5 Symbolkonfiguration VS Kommunikationsverwalter und Python/UA-Expert CODESYS Forge talk (Post)
Hallo zusammen, kann mich leider mattplc nur anschließen
Last updated: 2025-04-03

Post by ioannis-a on OPC UA: How to change NodeId ?! CODESYS Forge talk (Post)
Same question
Last updated: 2023-11-29

Post by anuj9326 on OPC-UA Client connection, Linux SL /Raspberry Pi CODESYS Forge talk (Post)
here is the snapshot
Last updated: 2024-08-21

Post by ricola on Change default node Id name on PFC200 OPC UA CODESYS Forge talk (Post)
so great !! thanks for this
Last updated: 2024-10-10

Post by timvh on OPC-UA ApplicationUri / ProductUri CODESYS Forge talk (Post)
Do you mean this: https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html
Last updated: 2024-05-10

Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06

Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06

Post by peterned on Programatically restart Codesys OPC UA server? CODESYS Forge talk (Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19

Post by alimans on OPC-UA Server, Symbol Set: Raise an error: Object reference not set to an instance of an object. CODESYS Forge talk (Post)
Hi everyone, I just created a very simple library without any code and, added it to my very simple project. after adding this library, I get an error when I try to open "Symbol Set" in "OPC UA Server" in "Communication Manager". Here is the code of my POU in the library: FUNCTION_BLOCK POU VAR eCommand : (CMD_NONE:=0, CMD_RESET:=-1) INT := CMD_NONE; END_VAR Attached is the error that I get. I also noticed that by removing the enumeration variable above (eCommand), I can open the "Symbol Set" again. Anybody has any idea why this error is raised and how could I use enumeration variables without error in "OPC UA Symbol Set"?
Last updated: 2024-08-08

Post by wiekon on OPC UA Probleme CODESYS Forge talk (Post)
Hallo zusammen, ich hoffe, ihr könnt mir helfen. Eigentlich möchte ich etwas ganz einfaches erreichen: CODESYS Runtime auf Raspberry Pi (OPC UA Client über Datasources Manager) <--> Cognex Designer (OPC UA Server) auf Windows PC Es will einfach nicht klappen. Wenn ich die Datenquelle hinzufüge, Adresse opc.tcp://192.168.150.10:4840 kommt immer BadRequestTimeout. Es ist keine Security und keine Authentication auf dem Server eingerichtet. Auf dem gleichen Raspberry klappt es aber wunderbar mit dem Tool opcua-client! Das heißt für micht, es ist kein Raspberry oder Firewall Thema. Was auch geht: Diese CODESYS Runtime auf dem Raspberry ist OPC UA Server (einfach über die Symbolkonfiguration) und eine andere CODESYS Runtime (ControlWin auf meinem Rechner) ist Client und verbindet sich über den DatasourceManager. Allerdings: Die Daten kommen im Client nur im 1s Takt an, obwohl die Aktualisierungsrate auf 10 ms eingstellt ist und sowohl Server, als auch die DatasourcesTask im Client auf 10 ms laufen. Ich kann einstellen, was ich will, es bleibt bei exakt 1 Sekunde Aktualisierungszeit im Client. Warum ist das so? Wenn ich auf dem gleichen Windows PC, auf dem die ControlWin läuft den UaExpert verwende und mich zum Raspberry verbinde, kriege ich die Daten im 10 ms Raster! Am Server liegts also nicht! Zurück zu meiner eigentlichen Aufgabe: Ich konnte mir vorübergehend so behelfen, dass ich auf dem gleichen Raspberry einen IO-Broker laufen lasse, der zwei Instanzen des OPC UA Clients hat. Er verbindet sich mit dem OPC UA Server des Raspberry und des Cognex Designers (also die zweite Instanz auf dem Raspberry, die es schafft, sich mit dem zu verbinden, nur Codesys schafft es nicht). Der IO Broker ist also das Bindeglied zwischen beiden OPC UA Servern. Über Javascript kopiere ich bei Wertänderung die Daten vom einen Server auf den anderen. Das ganze Funktioniert tadellos, nur die Performance ist nicht so toll, wobei ich mir nach der Erfahrung mit den zwei Codesys Instanzen nicht sicher bin, ob es nicht an Codesys liegt und der IO Broker nichts dafür kann. Ich komme mit dem Thema einfach nicht weiter. Könnt ihr mir Tipps geben? Am liebsten wäre mir natürlich der direkte Weg: Cognex Designer als Server --> Codesys als Client Aber zur Not wäre auch der IO Broker ein gangbarer Weg, allerdings muss die Performance stimmen. Gibt es noch weitere Wege? Ich danke euch für eure kreativen Ideen und Lösungsvorschläge!
Last updated: 2024-11-29

Post by vformanek on Datasource OPC UA Client error ID:7012 CODESYS Forge talk (Post)
Hey, I am facing the same problem. Basically UA Expert and other programs work fine with the login credentials. But codesys can not use them properly. I can see the server login to it manually but when I download the program and run the datasource never runs... Currently I am facing the same Error ID: 7012 and cant get it running properly.
Last updated: 2023-11-21