Post by albertocamina on Login problem with FileTransfer on Raspberry Pi 5
CODESYS Forge
talk
(Post)
Thanks @eschwellinger! So my settings look like this on CODESYSControl_User.cfg: [CmpWebServerHandlerV3] AllowFileTransferServices=1 CallVisuServicesDirectly=0 Sadly, is still asking for user and password as soon webvisu is loaded... Any clue? Many thanks!
Last updated: 2024-06-03
Post by hjohnson123 on PLC Memory consumption?
CODESYS Forge
talk
(Post)
Hi, How can you access the <root> of the Linux system? I'm struggling with this as the code above results in an invalid handle, as it cannot access '/'.</root> I am using Control for Raspberry Pi for context. Thanks.
Last updated: 2024-06-05
Post by nano on Is it possible to profile builds?
CODESYS Forge
talk
(Post)
pls check whats gookg on with antimalware-service-executable during the build most of my problem are directly connected to that "great" microsoft feature
Last updated: 2024-06-06
Post by ignat on [SOLVED] Safety EL6900 - SELC0012 Invalid number of connections[
CODESYS Forge
talk
(Post)
Hi kurvanov, could you please share the video you mentioned. I am struggling with basic data intechange between safety module and basic plc logic
Last updated: 2024-06-17
Post by ignat on SafetyApp - Exchange 8 bits from EtherCAT Safety Module to PLC mapping issue
CODESYS Forge
talk
(Post)
Hi transmin01, I am struggling with the same issue. Have you found out the solution?
Last updated: 2024-06-17
Post by davidbo on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask()
CODESYS Forge
talk
(Post)
I have done: systemctl stop dhcpcd sudo ip addr flush dev eth0 sudo ip link set eth0 up but a call to SysSockSetIpAddressAndNetMask does not give the eth0 an IP address Why?
Last updated: 2025-11-04
Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct)
CODESYS Forge
talk
(Post)
I have installed: SM_Drive_PosControl 4.18.0.0 and SM_Drive_RaspiStepper_Direct 0.0.0.7 and SM_Drive_RaspiStepper_PulsDir 0.0.0.7 And when I "Generate Code" I immediately get 6 errors (see attached file) What can I do?????
Last updated: 2025-11-09
Post by nano on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask()
CODESYS Forge
talk
(Post)
have u turned on the Ip-Setter in codesyscontrol.cfg? [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1
Last updated: 2025-11-11
Post by davidbo on License problem with Raspberry Pi
CODESYS Forge
talk
(Post)
To simplify your problem you shall not select dongle and get dongle errors. Do as shown In some cases you need 2 different licenses depending on the metrics. And yes the system gives not always give proper error messages when you try to reinstall a license
Last updated: 2025-12-01
Post by aniket-b on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
I am using Scara3 kinematic with EtherCAT PLC. The robot stops at the same place randomly after few cycles. Check attached image. I am getting SMC_ERROR.SMC_DI_FIELDBUS_LOST_SYNCRONICITY in all 3 axes.
Last updated: 2025-12-19
Post by kledo5 on What is the CFC editor (page oriented) "Add page" keyboard shortcut?
CODESYS Forge
talk
(Post)
Thanks for sharing this helpful tip with the tech community; I've learned so much new stuff. Let's take a break and play drift hunters, everyone! This top-notch racing game helps relieve stress after a tiring workday.
Last updated: 2026-01-06
Post by mawaloc on KeyPad Function in Visualization to fill a table
CODESYS Forge
talk
(Post)
THANK you !!! I finally find ou... may be not with same thing " use template" , so will looks your way of doing, maybe it's more properly done anyhow thank you
Last updated: 2026-01-08
Post by clockben on Python script to add libraries to project
CODESYS Forge
talk
(Post)
Hello, I have the same issue β some libraries arenβt resolved. When I load the libraries manually and delete them, reloading with the script works fine afterward. Have you found a solution since then? Many thanks in advance
Last updated: 2025-11-11
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
I did some work around by adding IN switch on top of OUT bulb picture(SwitchImage) and setting IN switch button to invisible but this is not quite elegant. How to combine it to one visu element?
Last updated: 2025-11-20
Post by osande on Trend/trace data
CODESYS Forge
talk
(Post)
Anyone have problems with trend in lastest release - SP21 Patch5? Does not record data, stores only zeros to the sqlite database and flatliners at zero in trend/trace views. Worked in P4.
Last updated: 2026-03-12
Post by alexschooneveld on OPC UA PubSub SL 1.3 β UADP WriterGroup with assigned PSS.SecurityGroup still publishes plaintext
CODESYS Forge
talk
(Post)
Thank you for your answer. I did install certificates, especially for OPC UA Client/Server tests. This OPC UA PubSub test uses pre-shared keys, not certificates. By the way, I do you 3.5.22 patch 2.
Last updated: 2026-06-30
Post by amira on Visu 4.9.1 auto-logon/login
CODESYS Forge
talk
(Post)
Hello Julian, could you please check in Chrome Password Manager Settings if the option "Offer to save passwords" is set? With this option selected, a pop-up message will then show up asking whether or not to save the password. Choose OK. Hope this helps.
Last updated: 2026-01-14
Post by fleaplc on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Did you check the communication with a sniffer ? (ex. Wireshark) to check if the holding get to zero by a wrong writing (client initialization?) o something else?
Last updated: 2026-01-27
Post by ulvis on CAA 3.5.16 TLS configuration - certificate
CODESYS Forge
talk
(Post)
Hi, did yo have any luck with this? I am facing the same challenge. Using a WinCTRLx64 but I get AccessViolation error in my CmpTlsCreateContext() call.
Last updated: 2026-03-23
Post by nulltrace on How change Unity-ID in TCP Modbus Slave
CODESYS Forge
talk
(Post)
Hey Husarz, thanks for your Message, now i understand your Problem, also able to reproduce that. Pls. give me a Short Time to Check some stuff on this, i'll come back to this Topic with news ASAP. Greetings
Last updated: 2026-04-03
Post by husarz17 on How change Unity-ID in TCP Modbus Slave
CODESYS Forge
talk
(Post)
Good to know there's a solution to this problem. I hope you'll be able to share it with me. I can't wait to hear about it.
Last updated: 2026-04-20
Post by reinier-geers on Network variable stops sending
CODESYS Forge
talk
(Post)
What version. 20.5 ? ive got also problems wiyth that version. Online change, it hangs itself after one hour. Then one project can problems. Ive change display with 21.0 . At home i turned on the 20.5 display. After 1 hour i goes to stop.
Last updated: 2026-05-06
Post by alex-n on Problem with keeping up the distance between two axes
CODESYS Forge
talk
(Post)
We use Inovance AC802 as PLC, IS810N Drive, library 4.10, connection via Ethercat and no any suprise at work.
Last updated: 2026-06-02
Post by tvm on XY Chart causes extremely long cycle in Visu Task
CODESYS Forge
talk
(Post)
No solution, but we have also seen similar behaviour with the XY chart, using Schneider M262 PLCs. It was a contributing factor to our decision to switch to TwinCAT HMI.
Last updated: 2026-07-22
Post by wollvieh on Raspberry Pi Runtime 4.22.0.0 vs. 4.20.0.0 I2C Bus not running...
CODESYS Forge
talk
(Post)
... the stars needed? --> yes! [CmpCharDevice] PermittedPath.0=/dev/i2c* PermittedPath.1=/dev/spidev0.0 PermittedPath.2=/sys/class/gpio/* PermittedPath.3=/dev/gpiochip* For me it worked with this additional settings in the file /etc/codesyscontrol/CODESYSControl_User.cfg.
Last updated: 2026-10-16
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.