Post by giackanto on Eoe issues with Windows and Linux
CODESYS Forge
talk
(Post)
Hello, I've been trying to use EoE for communication between a Windows PC and an M753 drive from Control Technique. Despite following some online guides (https://content.helpme-codesys.com/en/libs/EtherCATStack/4.3.0.0/Ethernet_over_EtherCAT/fld-Ethernet_over_EtherCAT.html) I haven’t had any success. Both are connected to a Debian device where RTE is running: The PC is connected via the Ethernet port. The drive is connected via the EtherCAT port. I'm unable to ping the drive from my Windows PC. Here is my configuration: On Debian: (See attachments 1, 2, 3) enp1s0 = Ethernet port enp2s0 = EtherCAT port tap2 = TAP device IP forwarding and routes are both configured. On Windows: (See attachments 4, 5) On Codesys: (See attachments 6, 7) Version: Windows 11 Debian GNU/Linux 11 Codesys 3.5.17 Control for Linux SL 4.7.0 EtherCAT 4.4.0 With this configuration, I can ping the TAP device, but not the drive (See attachment 8). Could someone explain how to properly configure all these settings? Thank you, GA
Last updated: 2023-12-19
Post by wbj0t on System libs and I/O Drivers
CODESYS Forge
talk
(Post)
Hi everyone. My question about: where I can learn (read or watch) an info about codesys workflow through the system IO libs? I want to know how to implement I/O drivers by my self. In the system libs I see many interfaces, methods etc... But there is no explanation about them, just names of methods and fields of the FBs. I know about this page: https://forge.codesys.com/drv/io-drivers/doc/Generic/ There is so BIG the device description file and not so clear explaining of the attributes and elements, also some elements or attributes missed at it all. Yes, there are code examples on this page, but, so shortly and, for example, code about Modbus drivers is absent. And even if I try to add the IoDrvFB with lib, I get and error, something like: "failed to load IoDrvFB driver". And what about the book of codesys that written by Gary Pratt? Is there information about system libs and drivers in this book more clearly? Thank you :)
Last updated: 2024-02-02
Post by hanoues on setting date and time on CPX-E
CODESYS Forge
talk
(Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21
Post by ewi04 on Git with visu
CODESYS Forge
talk
(Post)
Hi, I have several problems with the git extension. Situation: I am working with Codesys v3.5 SP19 Patch 1 and Git V1.2.1.0. The remote repository is GitLab Community Edition v16.1.2. I am working on a project with one other person. Problems: 1: After each start of Codesys all of the visu pages are marked as modified. So we have to discard all changes first. Otherwise the history is not clean and the merge request becomes more complex. I tested it with a new project and only local. I made the observation, that a page is not marked as modified when it is committed a second time (after a restart of codesys). But this is necessary after every change of a page. However, since we are working in a team, it seems we are playing ping-pong and so all pages are marked as modified on each startup. 2: Each image pool causes a parent child conflict. Also in my local project. The only solution that I have found, is to ignore the issue. Does anyone have the same problems? I think it looks more like bugs. Thanks ewi04
Last updated: 2023-11-22
Post by timvh on ernesto881124
CODESYS Forge
talk
(Post)
You will need a USB to RS485 converter to connect the PC to the Modbus RTU Slave Device. In Windows this converter will be recognized as Serial COM poort (e.g. COM2, or COM3, see the windows device manager to find this out). Select this port in your CODESYS application. On the PC you need to use the CODESYS Control Win (SoftPLC) to run your application. It will not work in simulation mode, because then the Modbus Communication will not be activated.
Last updated: 2023-09-14
Post by timvh on SafetyApp - "Invalid ERR Ack input"
CODESYS Forge
talk
(Post)
I had a similar error "Invalid ERR Ack input". What you need to do is link an variable from the "non-safe" PLC to the Group IOs of the POU in the Safety app. * Add a POU to the SafetyApp (probably already done, otherwise you don't get this error) * Right click on this POU - select properties * Go to the Group IOs tab * Link a variable to the Err.Ackn. input I don't know about the Size of zero, I didn't get this error. Were you able to fix this?
Last updated: 2023-11-16
Post by paterad on Edge gateway
CODESYS Forge
talk
(Post)
Hello, I am struggling with Edge gateway to the automation server. It is not possible to establish the link. When I create the Edge in codesys and get it to Automation server, it is red, unable to connect. Scan fails. RPi 4B Runtime 4.13.0.0 Edge gateway 4.13.0.0 Codesys 3.5.2.40 Any idea what to chase? I have been using previous versions of edge gateway. Now I updated all to latest versions, failed. Frustrating.
Last updated: 2024-12-03
Post by gatto on Read codesys version in the codesys application
CODESYS Forge
talk
(Post)
hi, i used another way declaration: pApp : POINTER TO APPLICATION; pAppInfo : POINTER TO APPLICATION_INFO; ProjectName : STRING (24) ; CodesysVersion : STRING (15) ; code: //library : // CmpApp // IoDrvEthernet // // Get Pointer to current application pApp := CmpApp.AppGetCurrent( pResult:= 0 ); // Get Pointer to Application information pAppInfo := CmpApp.AppGetApplicationInfo(pApp:= pApp, pResult:= 0 ); ProjectName := pAppInfo^.pstProjectName^ ; //convert codesys version to string CodesysVersion := IoDrvEthernet.UDINT_TO_IPSTRING ( udiIPAddress := pApp^.udiPSVersion ) ; so i think you need to convert your dwVersion in a UDINT and after convert UDINT_TO_IPSTRING
Last updated: 2025-01-17
Post by rmaas on STRING conversions to DWORD
CODESYS Forge
talk
(Post)
Hi, The '' characters in Codesys are there only to indicate it is a STRING type. They are not actually added to the string, maybe you are adding them unintentionally in the concat function? You can send your data from Codesys to Hercules to verify... Another option is to send the data as an array of bytes instead of a string, with every byte representing 1 ASCII character. https://www.ascii-code.com/ This way you are 100% sure Codesys is not adding any unwanted characters.
Last updated: 2025-01-31
Post by wehling-h on PI Input value
CODESYS Forge
talk
(Post)
Hi geoweil, have you tried to save changed values to remanent area or using a VAR RETAIN? After restart you have to initialize Counter with last remanent value. Depending on changes per cycle and the possibilitiy of your control unit to write remanent storage. Otherwise you need a buffering system to ensure save backup of last PI_Counter value. May you could read this Thread to get further help: https://forge.codesys.com/forge/talk/Engineering/thread/31e1c8349e/#bf48
Last updated: 2024-01-12
Post by bjarne-pagaard on WebVisu with Runtime Based User Management, Default user (no login) - is it possible?
CODESYS Forge
talk
(Post)
Hi, With the new Runtime Based User Management, is there any way for WebVisu clients to be logged in to a default user automatically - no login prompt? I would like for the default user to be able to perform normal operation of the machine, without logging in to the WebVisu. This is possible with the Legacy User Management. For the Runtime based user management, there seems to be a default user for the TargetVisu - but not for the WebVisu. -Bjarne
Last updated: 2024-03-14
Post by stuartjr on Webvisu IE Page Scroll Bars
CODESYS Forge
talk
(Post)
Is it possible to get scroll bars to show when displaying a web visualization in V2.3? I've got some big pages that I can scroll around when using the in-built visualization but when they are displayed in IE i can't seem to scroll around. All I can do it drag the window bigger onto my other display to get access to the extra area. I've also tried zooming the page out in IE but this doesn't seem to work at all.
Last updated: 2024-03-28
Post by alez on CANOpen SDO to write VISIBLE STRING
CODESYS Forge
talk
(Post)
Hello, I am experiencing difficulties in configuring a CANopen device by sending SDOs. In particular I am attempting to write an Object Dictionary that has VISIBLE STRING as the Data Type. When I try to configure the sending of an SDO from Codesys to configure this parameter I am not allowed to enter a string value. In my particular case I am trying to change the Manufacturer Device Name ( Index 0x1008 ). Could it be that Codesys doesn't manage these types of variables?
Last updated: 2024-04-29
Post by yofi on Raspberry PI change tag only responds after stopping PLC
CODESYS Forge
talk
(Post)
Using V19 Patch 7 and 4.11.0.0 for Pi 4 Model B, My problem is whenever I change a tag e.g bool from true to false it will change in software but the pin will only go high to low after pressing stop PLC in codesys and same if i want to bring it back to high, have to login start plc change it and stop plc in order to change. any insight ? thanks
Last updated: 2024-05-25
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Thread)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
Last updated: 2024-06-03
Post by dkugler on csv datei einlesen und verarbeiten
CODESYS Forge
talk
(Post)
in der https://store.codesys.com/de/codesys-iiot-libraries-sl.html ist u.a. die CSV Utility SL Bibliothek incl. Beispiel enthalten. Die kostet etwas. Generell Codesys Beispiele findest Du hier: https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_start_page.html Alternativ file read verwenden und Zeit investieren um von Hand zu Fuß den Dateiinhalt zu durchforsten: https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_cds_file_utilities.html In der OSCAT Library gab es mal noch etwas, da könnte google weiterhelfen
Last updated: 2024-10-28
Post by alex-at-xana on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
Hi Everyone, For a fast monitoring system I am using Ethercat oversampling and timestamping inputs. As the customers has a lot of different configurations out in the field, we went for a dynamic Ethercat configuration. Already got the whole detection chain working but now I am stuck since two days in debugging the configuration. Here are my quesitons: I extended the dynamic config example for the EL3632 16#0E303052: //EL3632 pSlave^.SetDCSettings(TRUE,TRUE,80,80,TRUE,4000,0,0); pSlave^.AddSyncManager(16#1000,128,16#26,TRUE,3); pSlave^.AddSyncManager(16#1080,128,16#22,TRUE,2); pSlave^.AddSyncManager(16#1100,0,16#4,TRUE,1); pSlave^.AddSyncManager(16#1110,214,16#20,TRUE,0); pSlave^.AddFMMU(0,214,0,7,16#1110,0,1,1); pSlave^.AddFMMU(0,1,0,0,16#80D,0,1,1); xKnown := TRUE; This leads to a PLL Error for these devices. I double and triple checked the configuraton, but cannot find the issue. There seems to be one difference: the config dialog creates a startup parameter: 16#10F3:16#05, Name: Command_0, Value:0. Bitlen: 16, Stop on fault: false, jumpt at fault: false: next line: 0 a) I do not find information on how to set this in my code. Can you help me there? b) Without trying to set the value, I get a PLL error for these devices in the master log. Is the config wrong? c) Do I need to set the Master to Autoconfigure or Manual? I used autoconfigure for my tests. The stack creates input data addresses for the slaves input data range (pSlaves[i].InputData) which are different from those created when I use the Engineering tools dialogs to configure Ethercat. Specifically, the addresses seem to be aligned at 16 byte boundaries when they are created using the engineering tool, but may appear at uneven addresses when I use the script in dynamic config. I did not try to access ULINT at uneven addresses yet, but I am suspecting this may be a problem. Do I need to manually align the addresses ? Any help is appreciated...
Last updated: 2024-09-10
Post by dandyk on Dynamic Images
CODESYS Forge
talk
(Post)
Hello, I have very similar problem, but it seems that your solution does not work for me. I am using TwinCAT XAE Shell v3.1.4024.55 and TwinCAT Runtime. Sorry for writing here on codesys forge, but since I found the only relevant topic here and since TwinCAT is almost the same with CODESYS in many applications, I chose to write here. I simply need to dynamically update image in visualization based on camera trigger (I am doing a machine vision application). Camera triggers an image, my program processes it (applies thresholding, draws contours etc...) and saves the processed image in the runtime location (the same one you were mentioning). This was done successfully. I need to make it work at runtime, while the program is executing and I need to refresh the image in the visualization each time camera triggers a new image and program processes it. When I create image element in the visualization and define the bitmap ID variable as STRING which contains the image ID defined in the image pool, then it displays the image in the image pool, but does not work at runtime, while the program is executing. I also used the Bitmap Version. I declared it in Global variable list as integer with initial value of 0 and wrote the variable in the bitmap version in the image element in visualization. Each time new image is saved to the runtime location, I wrote a program to increment Bitmap Version by 1. It increments and the image does not update in the visualization, unfortunately. I think that bitmap version is working correctly and deletes the cached image as it is supposed to, but the Image Pool does not update the image ID with the new image... the path to the image is always the same... only the actual image changes with the same file name. Image Pool is not dynamic and cannot refresh the image in the path to the actual one at runtime. How can I refresh the image ID in the image pool at runtime? Bitmap version only deletes cached image and reloads the image from the image ID, but the image ID has the same image, because image pool won't update at runtime. Do you know any solution to this problem?
Last updated: 2024-04-06
Post by jami on Reading multiple lines from csv file
CODESYS Forge
talk
(Post)
Hello, i am trying to read multiple lines from csv file with caa file library and oscat. I have wrote 7 lines in the csv with separation '$R$L'. In my "extracting values" part I check line feeds and chars. After that I convert my buffer to string with oscat but I'm only able to read the first line from the csv. No matter if I even change start position where I start converting the buffer, I only get the first line. Here's my code for the reading and extracting value parts: 4: (*Reading the file*) fileread.hFile := filehandle; fileread.pBuffer := ADR(buffer); filesize1:=SIZEOF (buffer); fileread.szbuffer:=filesize1; fileread.udiTimeOut := 100000; fileread(xExecute := TRUE); IF fileRead.xDone THEN iFilesize:=TO_INT(fileread.szSize); writestate:=3; fileRead.xExecute := FALSE; END_IF 5: (*Extracting values*) //here i check the number of line feeds and chars. It works WHILE i < ifilesize DO c:=buffer[i]; IF c= 10 THEN IF lineindex<=99 THEN lineIndex := lineIndex + 1; END_IF ELSIF c <> 13 THEN IF charIndex <= 1000 THEN charIndex := charIndex + 1; END_IF END_IF i := i + 1; END_WHILE // Here i convert the buffer to string and transfer it to filelines:ARRAY[0..99] of string[254]. trig(CLK:=BUTTON); IF trig.Q THEN fileLines[i2]:=oscat_basic.BUFFER_TO_STRING(PT:=ADR(buffer), Size:=TO_UINT(fileread.szBuffer), start:=TO_UINT(bufferStart), stop:=TO_UINT(filesize1)); i2:=i2+1; bufferstart:=bufferstart+80; END_IF If anyone has idea how to read multiple lines, it would be nice. Even if you have example codes that work, that would help a lot.
Last updated: 2025-07-18
Post by adamrobotic on llcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008
CODESYS Forge
talk
(Post)
Hi All, Recently I have been experiencing a issue in CodeSys SP16 Patch 3, with a exception which comes up after I have made several online changes. callcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008, after I experience this fault then I receive a error message for any subsequent online change "online change failed, no task gap within 10000ms". To recover either the controller needs a orgin reset, which will allow online edits thereafter until falling back into the loop. I am using a TURCK TX707 product which is controlling robot trajectory, We have hard coded the coordinate data rather than using persistence variables so hence the need to do online changes consistently. I have read on the forum other people have experienced similar issue with the online task gap, but I have no task which have same priority and also monitored the CPU usage and have not seen it go above 13%. Anyones help would be much appreciated, thankyou.
Last updated: 2023-08-18
Post by trusty-squire on Confused by dwIpoTime input for SMC_Interpolator
CODESYS Forge
talk
(Post)
Hi, Learning Codesys CNC, and I am confused by the dwIpoTime parameter. I have a basic demo application, using SMC_Interpolator feeding into SMC_TRAFO_Gantry2Tool2, which then sets the position of the x/y SM_Drive_Virtual axis. I also have a C axis which revolves the tool, which is controlled using a simple tangential angle calculation SMC_CalcDirectionFromVector. The GCode I'm using has feed/accel set at 500. The axis configuration limits are well above that (2000). What's strange is that, when I run the simulation, the feed speed changes drastically when I update the variable dwIpoTime. The larger the number, the faster it moves. What's going on here? The documentation only says "This variable has to be set for each call. It represents the cycle time in ÎĽsec." Why does it change the feed speed I'm seeing the in simulation? What is a good number to use? The example I was looking at set it at 5000. Screenshot attached.
Last updated: 2024-07-18
Post by jbu0105 on Dynamic limits invaild
CODESYS Forge
talk
(Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04
Post by jbu0105 on Dynamic limits invaild
CODESYS Forge
talk
(Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04
Post by dogulas on OPC UA C# client connecting to OPC UA CODESYS server
CODESYS Forge
talk
(Post)
Noob alert! I’m just getting my feet wet with CODESYS. I have a “Hello World” project in the CODESYS IDE. I’m using the Win SoftPLC on the same computer. I’ve added a Communication Manager under the Application node. Under that is “OPC UA Server -> IEC Symbol Publishing 01”. I also added “OPC_UA_Symbols -> Information Model”. I’m not sure I need the second thing. I was grasping at straws. I also set up several dummy symbols in the IEC Symbol Publishing 01 node. In my C# application, I am trying to get an instance of EndpointDescription from CoreClientUtils.SelectEndpoint(“opc.tcp://localhost:1217/Gateway-1”, useSecurity: false, 15000). I wasn’t sure about the “Gateway-1”. I found that in the CODESYS IDE under the project -> Communication Settings. When I execute the previous method call in C#, I get: “BadSecureChannelClosed”. I have no idea what that means. Any pointers to documentation are welcome.
Last updated: 2024-08-16
Post by sushela on Temu Coupon Code 90% Off [acq615756] for First-Time Users
CODESYS Forge
talk
(Post)
Temu Coupon Code 90% Off [acq615756]: A Comprehensive Guide Temu has emerged as a top choice for shoppers looking for quality products at affordable prices. Whether you're shopping for electronics, clothing, beauty products, or home essentials, Temu has it all. And to make your shopping experience even better, Temu offers various coupon codes that give users access to significant discounts. One of the most sought-after deals is the Temu coupon code 90% off [acq615756] for first-time users. In this article, we’ll explore everything you need to know about this offer and other popular Temu coupon codes, including those for existing customers. Temu Coupon Code 90% Off [acq615756] for First-Time Users If you’re new to Temu, you’re in for a treat! The Temu coupon code 90% off [acq615756] is a fantastic offer for first-time users, providing a massive discount on your initial purchase. This deal allows you to get your first order at almost one-tenth of the price, which is an amazing opportunity to test out Temu’s products without breaking the bank. To use the 90% off coupon: Sign up for a Temu account. Add eligible items to your cart. Apply the [acq615756] code at checkout. Enjoy your steep discount and complete your purchase. This offer is usually limited to first-time users, so if you’re already a registered user, keep reading for other exciting discount options. Temu Coupon Code $100 Off [acq615756] The Temu coupon code $100 off [acq615756] is another high-value offer, perfect for customers making larger purchases. This coupon gives users a $100 discount on their order, which is especially helpful when buying high-priced items or bulk purchases. While some restrictions may apply (like minimum order values), the $100 off coupon is a powerful way to slash your total cost significantly. Temu Coupon Code $40 Off [acq615756] Looking for a smaller yet substantial discount? The Temu coupon code $40 off [acq615756] is ideal for mid-range purchases. Whether you're picking up household essentials or indulging in fashion items, this $40 discount can make your shopping much more affordable. Keep an eye on the terms, as there may be minimum purchase requirements or product restrictions tied to this code. Temu Coupon Code 2024 [acq615756] for Existing Customers Many coupon offers tend to focus on new users, but the Temu coupon code 2024 [acq615756] is specifically designed for existing customers. If you’ve already shopped on Temu before, this code allows you to continue enjoying discounts without creating a new account. While the exact discount may vary, the 2024 [acq615756] code typically offers a percentage off or a flat discount on eligible items, helping loyal customers save on their next purchase. Temu Coupon Code for Existing Customers [acq615756] If you’re an existing customer, don’t worry—you can still benefit from attractive deals. The Temu coupon code for existing customers [acq615756] offers various levels of savings. Although many top discounts target new users, Temu ensures that returning shoppers also get the chance to save. The [acq615756] code for existing users can provide anywhere from 10% to 50% off on selected items or offer a flat discount depending on the promotion at the time. Always check the latest terms before applying this coupon. Temu Coupon Code $300 Off [acq615756] For those making big purchases or shopping for expensive items, the Temu coupon code $300 off [acq615756] can be a game-changer. This discount allows users to save up to $300 on their total order, making it one of the highest-value coupons available on the platform. This offer is generally tied to larger order values and specific products, so make sure your cart meets the minimum spend before attempting to redeem it. Temu Coupon Code $120 Off [acq615756] The Temu coupon code $120 off [acq615756] strikes a balance between mid- and high-tier purchases. With this code, you can get a $120 discount on qualifying orders, providing excellent savings for those looking to buy electronics, furniture, or other pricier items. This code is perfect for users who want a substantial discount but aren’t making purchases large enough to qualify for the $300 off coupon. Temu Coupon Code 50% Off [acq615756] The Temu coupon code 50% off [acq615756] is a versatile discount that works across a broad range of products. Whether you're shopping for home goods, fashion, or tech accessories, this code can halve your total cost, making it one of the most popular offers among shoppers. The 50% off coupon can be applied to eligible items in your cart, though it might come with certain conditions such as a minimum spend or item restrictions. Be sure to review the specific terms before using the code. How to Use Temu Coupon Code [acq615756] Using any of the Temu coupon codes, including [acq615756], is simple and straightforward. Here’s a step-by-step guide: Create or Log in to Your Temu Account: If you’re a first-time user, sign up for a new account. If you’re an existing user, simply log in. Add Items to Your Cart: Browse through Temu’s vast selection of products and add eligible items to your cart. Apply the Coupon Code: Enter [acq615756] or the relevant code in the promo code section at checkout. Complete the Purchase: Review the final price, and if everything looks good, proceed with your payment and enjoy your savings. Conclusion Temu offers a variety of coupon codes that can help both new and existing customers save significantly on their purchases. Whether you’re looking for a 90% off coupon for your first order or a $300 off coupon for large purchases, there’s a code that fits your needs. The Temu coupon code [acq615756] is particularly valuable, offering a range of discounts that can be applied to multiple orders. Make sure to check the specific terms and conditions of each offer to maximize your savings. Happy shopping!
Last updated: 2024-10-26
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.